Search NASA⌕ Search

SEARCH · Search NASA

Results for “NTF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analysis of Flow Angularity Repeatability Tests in the NTF

An extensive data base of flow angularity repeatability measurements from four NTF check standard model tests is analyzed for statistical consistency and to characterize the results for prediction of angle-of-attack uncertainty for customer tests. A procedure for quality assurance for flow angularity measurements during customer tests is also presented. The efficacy of the procedure is tested using results from a customer test.

Hemsch, Michael J.↗

Cold Flow Plume Entrainment Test Final Report NTF Test Number 2456

As part of the Space Shuttle Return to Flight (RTF) program, Marshall Space Flight Center (MSFC) performed computational fluid dynamics (CFD) analysis to define the velocity flowfields around the Shuttle stack at liftoff. These CFD predicted velocity flowfields were used in debris transport analysis (DTA). High speed flows such as plumes induce or 'entrain' mass from the surrounding environment. Previous work had shown that CFD analysis over-predicts plume induced flows. Therefore, the DTA would tend to 1) predict more debris impacts, and 2) the debris velocity (and kinetic energy) of those impacts would be too high. At a November, 2004 peer-review it was recommended that the Liftoff DTA team quantify the uncertainty in the DTA caused by the CFD's over prediction of plume induced flow. To do so, the Liftoff DTA team needed benchmark quality data for plume induced flow to quantify the CFD accuracy and its effect on the DTA. MSFC's Nozzle Test Facility (NTF) conducted the "Nozzle Induced Flows test, P#2456" to obtain experimental data for plume induced flows for nozzle flow exhausting into q quiescent freestream. Planning for the test began in December, 2004 and the experimental data was obtained in February and March of 2005. The funding for this test was provided by MSFC's Space Shuttle Propulsion Systems Integration and Engineering office.

Ruf, Joseph H.↗

The NTF Inlet Guide Vanes Thermal Gradient Problem and Its Mitigation

The National Transonic Facility (NTF) utilizes Inlet Guide Vanes (IGV) to provide precise, quick response Mach number control for the tunnel. During cryogenic operations, the massive IGV structure can experience large thermal gradients, measured as "Delta T or (Delta)T", between the IGV ring and its support structure called the transfer case. If these temperature gradients are too large, the IGV structure can be stressed beyond its safety limit and cease operation. In recent years, (Delta)T readings exceeding the prescribed safety limits were observed frequently during cryogenic operations, particularly during model access. The tactical operation methods of the tunnel to minimize (Delta)T did not always succeed. One obvious option to remedy this condition is to warm up the IGV structure by disabling the main drive operation, but this "natural" warm up method can takes days in some cases, resulting in productivity loss. This paper documents the thermal gradient problem associated with the IGV structure during cryogenic operation and how the facility has recently achieved an acceptable mitigation which has resulted in improved efficiency of operations.

Venkat, Venki S.↗

NASA Common Research Model Test Envelope Extension With Active Sting Damping at NTF

The NASA Common Research Model (CRM) high Reynolds number transonic wind tunnel testing program was established to generate an experimental database for applied Computational Fluid Dynamics (CFD) validation studies. During transonic wind tunnel tests, the CRM encounters large sting vibrations when the angle of attack approaches the second pitching moment break, which can sometimes become divergent. CRM transonic test data analysis suggests that sting divergent oscillations are related to negative net sting damping episodes associated with flow separation instability. The National Transonic Facility (NTF) has been addressing remedies to extend polar testing up to and beyond the second pitching moment break point of the test articles using an active piezoceramic damper system for both ambient and cryogenic temperatures. This paper reviews CRM test results to gain understanding of sting dynamics with a simple model describing the mechanics of a sting-model system and presents the performance of the damper under cryogenic conditions.

Rivers, Melissa B.↗

How alkyl branching shapes structure in imidazolium and pyrrolidinium NTf 2 ionic liquids

High-energy X-ray scattering experiments and molecular dynamics (MD) simulations were carried out on ionic liquids (ILs) consisting of 1-alkyl-3-methylimidazolium and 1-alkyl-1-methylpyrrolidinium cations. These cations were paired with bis(trifluoromethylsulfonyl)amide anions and identical alkyl tails were used for both cationic species. The goal of this work is to investigate how the nanoscale structure of the ionic liquid changes with the length and with the degree of branching of the alkyl tail, for ILs having a common anion. We investigate spatial correlations in the intermolecular region, focusing on the intrinsic charge-charge interactions that characterize all ionic liquids, as well as the nanoscale domain segregation that is present in IL species with significant nonpolar components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NTF as a national facility

Activities which led to the definition of the National Transonic Facility and the general agreements reached regarding its use and operations are reviewed. Topics discussed include: redefinition of test requirements, development of low cost options, consideration of a single transonic facility using existing hardware if feasible, facility concept recommendations, and acquisition schedule proposals.

Nicks, O. W.↗

X-29A for NTF wind-tunnel/flight correlations

Considerations and recommendations for correlation are given. Basic tunnel calibration prior to research and development tests is suggested. Areas of concentration include: wing cruise drag and drag rise, wing separation and stall, afterbody and base drag, propulsion effects, vortex flows, cavity flows, and excrescences.

Daforno, G.↗

Some NTF laser velocimeter installation and operation considerations

Two velocimeter techniques were considered as potential candidates for achieving the flow field angularity measurements. The first was the fringe laser Doppler velocimeter, (LDV). A great deal of experience was obtained with this approach at Langley and the literature is rich with papers describing many experimental applications and system performance details. That is, many velocity flow field measurements were conducted with the LDV but not with high resolution precise angularity measurements. The second candidate considered was the two-spot laser transit anemometer, (LTA). This approach was not as extensively used as the LDV technique, but literature does contain experimental applications and system performance details. Again, a lack of high resolution, high precision angularity measurements is noted for the LTA. The results of the study suggested that the LDV and LTA tests and other efforts did not reveal any fundamental problems that would suggest that laser velocimetry is not a viable diagnostic technique for the National Transonic Facility. However, there are a number of engineering problems that need to be solved.

Hunter, W. W., Jr.↗

Aspects of fracture mechanics in cryogenic model design. Part 2: NTF materials

Results of fatigue crack growth and fracture toughness tests conducted on three candidate materials are presented. Fatigue crack growth and fracture toughness tests were conducted on NITRONIC 40 at room temperature and -275 F. Fracture toughness tests were also conducted on Vascomax 200 and 250 maraging steel from room temperature to -320 F. NITRONIC 40 was used to make the Pathfinder 1 model. The fatigue crack growth rate tests were conducted at room temperature and -275 F on three-point notch bend specimens. The fracture toughness tests on the as received and stress relieved materials at -275 F were conducted on the center crack tension specimens. Toughness tests were also conducted on Vascomax CVM-200 and CVM-250 maraging steel from room temperature to -320 F using round and rectangular compact specimens.

Newman, J. C., Jr.↗

Status of NTF models

Eight wind tunnel models to be tested in the National Transonic Facility are discussed.

Bradshaw, J. F.↗

NTF model concept for the X-29A. Part 1: Requirements, guidelines, and design loads

A few Charpy samples containing a transverse EB weld at the V-notch location were produced. Three tensile specimens containing a transverse weld were also produced. These samples were tested at cryogenic temperatures. The welded Charpy samples resulted in average impact values of 20 ft-lb. This average value is as good as the NASA test samples with the base metal. The tensile specimens broke at slightly higher loads than had been calculated. The Charpy specimens did not come up to the prescribed level of 25 ft-lb. The results of the specimen tests are presented.

Daforno, G.↗

NTF model concept for the X-29A. Part 2: Design and fabrication concept

The first concept was done to determine if a small model to fit the NASA Langley sizing criteria could accommodate aerodynamic and mechanical requirements. For a model wing span of 1.7 ft (and a length of 3 ft), the model is 6.25 percent (1/16 scale). The results were encouraging enough for Grumman to request, in early December 1981, that the design concept be refined at NASA Langley, where up-to-date cryogenic model design information was available. This working session was completed by a Grumman designer by mid-December. In its present form, the concept will be the basis for any continued effort.

Toscano, G.↗

NTF model pressure measurements

Pressure measurements on the National Transonic Facility models will be made using electronically scanned pressure instrumentation. The system consists of pressure modules, a pressure calibration standard, and a system controller. The pressure modules, which must be operated above -18 C, will be housed in model-integrated designed thermally controlled containers. The Pathfinder 1 192-channel pressure package is described. Recent and planned developments to reduce the pressure module's volume per channel ratio are discussed, including the 48-channel module and a proposed 32-channel module that would be 2.54 by 2.54 by 8.13 cm. Pressure transducers capable of operating at cryogenic temperatures for dynamic and static pressure measurements are discussed.

Kern, F. A.↗

Design of high-Reynolds-number flat-plate experiments in the NTF

The design of an experiment to measure skin friction and turbulent boundary-layer characteristics at Reynolds numbers exceeding one billion is described. The experiment will be conducted in a zero-pressure-gradient flow on a flat plate in the National Transonic Facility. The development of computational codes to analyze the aerodynamic loads and the blockage is documented. Novel instrumentationn techniques and models, designed to operate in cryogenic environments, are presented. Special problems associated with aerodynamic loads, surface finish, and hot-wire anemometers are discussed.

Saric, W. S.↗

Improved Seal for NTF Fan Shaft

New seal more effective and lasts longer. Seal consists of five felt rings interspersed with four polytetrafluoroethylene rings having inner diameter slightly larger than shaft. Spaces between polytetrafluoroethylene rings and shaft produce labyrinth effect, which increases degree of sealing.

Crossley, E. A., Jr.↗

Navier-Stokes calculation of transonic flow past the NTF 65 deg delta wing

Models of four delta wings were built and tested in the 8 x 8 ft Transonic Wind Tunnel at LaRC. The wings are identical in planform shape with a swept-back angle of 65 degrees, but bear different leading edge profiles. The models were tested under pressurized and cryogenic conditions to simulate true flight Reynolds numbers. Data on the aerodynamic forces and pressure distributions at various locations on the wings were taken at various flight Mach numbers and angles of attack. Effects of high Reynolds number and leading edge radius on the aerodynamic characteristics of the wings are being accessed. To thoroughly understand the turbulent, vortical flow around the wings, an effort to perform computational aerodynamic analysis is being made. The objective of the analysis is to supplement and validate the experimental data and explain the high Reynolds number and leading edge effects. GRIDGEN, a software developed by General Dynamics, is being used to generate the grid topology for the flow field around the wings. The flow solver to be used is CFL3D, a computation fluid dynamics code developed at LaRC. Based on the geometric description of the wings, a FORTRAN program called WINGSURF was written to generate the databases defining the surface geometry of the wings. To match the true geometry of the models in the wind tunnel for realistic comparison with experimental results, databases defining the sting support for the wing models were also created by two other FORTRAN programs, STINJOIN and STINREAR. Listing of the programs are attached and the geometry of a typical wing model with the sting support is shown. Other aspects of the investigation are discussed.

Wu, Chivey C.↗

NTF Modeling Program

The National Transonic Facility presents a design for and assessment of a transonic wind tunnel. Among the topics covered in viewgraph format are: aerodynamic validation models, scale models of wind tunnel components, performance evaluations of various wind tunnel parameters, and drive systems.

McKinney, L. Wayne↗