Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

The Influence of Mesoscale Particle Structure on the Electrode Degradation and Resultant Electrochemistry of Lithium Ion Cells With Nickel Rich Lithium Nickel Manganese Cobalt Oxide Positive Electrodes

Nickel-rich lithium nickel manganese cobalt oxide, NMC (LiNi x Mn y Co z O 2 ), materials are desirable positive electrodes in lithium ion batteries, providing high capacity and energy density. The mesoscale structure of NMC materials is commonly a polycrystalline aggregate, providing opportunity for short lithium ion transport distance of the small primary particles, yet facile material handling due to the larger secondary particles. On (de)lithiation the NMC unit cell changes volume, where the anisotropic strain can result in secondary particle fracture. This secondary particle fracture process during cycling has been associated with several degradation modes of NMC materials in LIBs. In this work, a milling process was determined whereby the secondary particles could be pre-fractured with retention of the parent primary particle crystallographic structure, crystallite size, and morphology, providing the ability to unambiguously determine the influence of NMC secondary particle size and mesostructure on resultant functional behavior. The bulk and interfacial properties and electrochemistry of as-received commercially obtained polycrystal NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 , PC NMC) and its milled MPC NMC counterpart were compared. The smaller secondary particle size, higher surface area MPC NMC was found to result in 1) greater cathode tortuosity, 2) reduced surface Ni on the cycled MPC cathodes consistent with surface reconstruction, and 3) increased Ni deposition on the anodes from cathode-anode crosstalk. These factors manifested in unfavorable electrochemical behavior of MPC with lower functional capacity at both 1C and C/10 rates and higher impedance over extended moderate voltage (dis)charge cycling.

36 MATERIALS SCIENCE↗

Reaction Mechanism of Electrodeposited ε-MnO 2 : A Proton-Centered Pathway in Aqueous Zn-Ion Systems

Aqueous Zn/MnO 2 batteries have garnered significant interests owing to their abundance, high theoretical specific capacity, safety, and low cost. However, large-scale application of these systems is limited by the incomplete understanding of the MnO 2 reaction chemistry. The different crystal lattice structures among MnO 2 polymorphs contribute to the variations in reported reaction mechanisms. Among them, ε-MnO 2 polymorph, the dominant phase in electrolytic manganese dioxide (EMD), is notably observed during the charge cycles of aqueous Zn/MnO 2 batteries. Here, in this work, we investigate the electrochemical behavior of an ε-MnO 2 cathode synthesized via electrodeposition from a ZnSO 4 and MnSO 4 electrolyte, onto a 3-dimensional carbon cloth substrate. Proton intercalation emerges as the dominant charge storage mechanism, critically enabling the reversibility of ε-MnO 2 during cycling, as revealed by operando synchrotron X-ray diffraction and X-ray absorption spectroscopy. Additionally, a proton-coupled dissolution/redeposition pathway operates alongside minor Zn 2+ intercalation, as quantified by Rietveld refinement. Morphological and chemical heterogeneities are studied by transmission X-ray microscopy further validates this reaction mechanism. These mechanistic insights provide the foundation for rationally designing Zn/MnO 2 batteries with optimized proton dynamics and charge transfer, advancing these systems as a viable solution for safe, cost-effective grid-scale energy storage.

36 MATERIALS SCIENCE↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

Magnetic Field Optimization of an In-Vacuum Undulator at NSLS-II Transactions on Applied Superconductivity

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1 st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. Furthermore, the device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. We describe here the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

43 PARTICLE ACCELERATORS↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-pole wigglers at NSLS-II

The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.

36 MATERIALS SCIENCE↗

Discovery of a new phase transition and high-valent redox mechanism in Fe-substituted Na 2 Mn 3 O 7

Sodium-ion batteries are a promising lower-cost alternative to lithium-ion batteries, but further improvements in electrochemical performance are required. One strategy to increase capacity is to enable reversible high-valent cationic and anionic redox in layered cathode materials; however, this is typically accompanied by structural degradation. Here, in this study, we elucidate the mechanism by which Fe-doped Na 2 Mn 3 O 7 , featuring ordered transition metal-vacancies, achieves reversible high-valent redox. Using Mössbauer spectroscopy, soft X-ray absorption spectroscopy (XAS), and in-situ hard XAS, we demonstrate reversible high-valent cationic redox involving both Fe and Mn while in-situ Raman confirms the absence of local structural degradation associated with oxygen redox. Combining in-situ X-ray diffraction with theoretical calculations, we further identify a previously unreported global phase transition from the $\bar{P1}$ to the $P2_1/c$ space group during electrochemical cycling and develop a physical model describing this structural evolution. These results provide insights for structurally stable layered sodium transition metal oxide cathodes with reversible high-valent redox.

36 MATERIALS SCIENCE↗

Quantum correlation imaging via X-ray parametric down-conversion

Quantum imaging leverages correlations between pairs of photons and has the potential to obtain image information beyond what classical sources provide. Extending this approach to the X-ray regime has been limited by low photon-pair generation rates and the lack of suitable detectors. Here, we demonstrate X-ray coincidence imaging using spontaneous parametric down-conversion (SPDC) and a pixelated area detector with time- and energy-resolved capabilities. This configuration enables simultaneous detection of correlated X-ray photon pairs and coincidence-based imaging of test objects, including a biological specimen. The increased coincidence rate and spatially resolved detection establish a basis for future quantum-enhanced and low-dose X-ray imaging.

Goodrich, Justin C. [Brookhaven National Laborator↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Milestone 1.2.15: Feasibility of In Situ Accelerated Aluminum Coupon Radiolysis by Synchrotron X-Rays

Extended dry storage of aluminum-clad spent nuclear fuel (ASNF) requires an assessment of the radiolytic generation of molecular hydrogen gas (H2) from the ASNF’s corrosion layers. H2 accumulation can potentially lead to storage canister embrittlement/rupture and the accumulation of flammable gas mixtures in accident scenarios. To date, computational models have been developed for the prediction of radiolytic H2 generation from samples exposed to lower absorbed dose regimes (up to ~3 MGy). However, greater accuracy is needed for higher absorbed doses (> 25 MGy) where the concentration of H2 ultimately reaches a steady-state. Data in this area is limited due to the amount of time taken (months) to accumulate such high gamma doses. Furthermore, a recent study observed radiation-induced damage to the surface of pre-corroded aluminum alloy coupons at high absorbed gamma doses. Despite this observation and its implications, there is currently no computational connection between the radiolytic formation of H2 and changes in the composition and morphology of the cladding’s corrosion layers with absorbed dose. To develop a better understanding of the processes and effects described above, the present study aimed to evaluate the feasibility of leveraging synchrotron x-ray capabilities for coupled accelerated irradiation and in situ surface characterization of ASNF alloys. To that end, National Synchrotron Light Source II (NSLS-II) beamtime was secured and a series of aluminum alloy 1100 (AA1100) wires, prepared under a variety of conditions, were interrogated using ex situ x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques at Idaho National Laboratory (INL) and ex situ and in situ XRD capabilities at the NSLS-II x-ray powder diffraction (XPD) beamline. Results indicated that performing synchrotron XRD using the available XPD beamline configuration can provide sufficient radiation dose but cannot discern changes in the composition and morphology of sample corrosion layers. Additionally, ex situ XRD and SEM data from Idaho National Laboratory (INL) indicated that the pre-corrosion of AA1100 wires did not generate an appreciably thick corrosion layer, as compared with previous aluminum coupon studies. These thinner surface corrosion layers were not sufficient for detection by both ex situ and in situ synchrotron XRD, specifically under consideration of the NSLS-II XPD beamline’s configuration primarily capturing information from the sample’s bulk material, i.e., aluminum metal. In summary, the use of the NSLS-II XPD beamline for promoting accelerated radiolysis and in situ surface characterization is not appropriate for this program’s goals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterizing Hidden Structures at NSLS-II: Strongly Correlated Electron Systems, Functional Ceramics, Batteries, and Beyond

Brookhaven National Laboratory (New York) launched its highenergy X-ray science program at the inception of the National Synchrotron Light Source (NSLS), a U.S. Department of Energy (DOE) Office of Science User Facility. Built in the 1980s, the NSLS X17 beamline was the world’s first super-conducting wiggler facility and remained in service for more than 30 years. The NSLS facility was decommissioned in October 2014 and a third-generation synchrotron machine, DOE’s National Synchrotron Light Source II (NSLS-II), took over. Six years after completing construction, NSLS-II has a portfolio of 29 beamlines that includes two operating high-energy powder diffraction beamlines (XPD and PDF) and one high-energy imaging and diffraction beamline under construction (HEX).

36 MATERIALS SCIENCE↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

SwinCell: a 3D transformer and flow-based framework for improved cell segmentation

Segmentation of three-dimensional (3D) cellular images is fundamental for studying and understanding cell structure and function. However, 3D cellular segmentation is challenging, particularly for dense cells and tissues. This challenge arises mainly from the complex contextual information within 3D images, anisotropic properties, and the sensitivity to internal cellular structures, which often lead to incorrect segmentation. In this work, we introduce SwinCell, a 3D transformer-based framework that leverages Swin-transformer to predict flow and differentiate individual cell instances. We demonstrate SwinCell’s utility in the segmentation of nuclei, colon tissue cells, and densely cultured cells. SwinCell strikes a balance between maintaining detailed local feature recognition and understanding broader contextual information. Through extensive testing with both public and in-house 3D cell imaging datasets, SwinCell shows utility in segmenting dense cells, making it a valuable tool for 3D segmentation in cellular analysis that could expedite research in cell biology and tissue engineering.

59 BASIC BIOLOGICAL SCIENCES↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Solute diffusion behavior during heat treatment and its impact in Sc-microalloyed Al-Cu system

Scandium (Sc) is a promising microalloying element that enhances the strength and thermal stability of aluminum (Al) alloys. However, these benefits are not fully realized in aluminum-copper (Al-Cu) systems, and corrosion resistance often declines due to the complex phase evolution and diffusion behavior of Cu and Sc. Here, to clarify this, solute diffusion behavior and Cu-Sc interaction during heat treatment (HT) were investigated using in situ synchrotron-based transmission x-ray microscopy (TXM), wide-angle x-ray scattering (WAXS), and x-ray absorption near-edge structure (XANES) spectroscopy. The results, supported by electron microscopy, reveal strong Cu-Sc bonding that significantly impedes solute diffusion, leading to inhomogeneous solute distribution and non-uniform precipitation. Moreover, the Al-Cu-Sc eutectic phase exhibits high thermal stability, resisting dissolution even near the matrix liquidus. These findings quantitatively elucidate the sluggish diffusion kinetics of Cu and Sc, which can help redesign HT schedules to improve both mechanical properties and corrosion resistance in Sc-microalloyed Al-Cu alloys.