Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neck initiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Intensity-Modulated Radiotherapy is Associated With Improved Global Quality of Life Among Long-term Survivors of Head-and-Neck Cancer

Purpose: To compare the long-term quality of life among patients treated with and without intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: University of Washington Quality of Life instrument scores were reviewed for 155 patients previously treated with radiation therapy for locally advanced head-and-neck cancer. All patients were disease free and had at least 2 years of follow-up. Eighty-four patients (54%) were treated with IMRT. The remaining 71 patients (46%) were treated with three-dimensional conformal radiotherapy (3D CRT) by use of initial opposed lateral fields matched to a low anterior neck field. Results: The mean global quality of life scores were 67.5 and 80.1 for the IMRT patients at 1 and 2 years, respectively, compared with 55.4 and 57.0 for the 3D CRT patients, respectively (p < 0.001). At 1 year after the completion of radiation therapy, the proportion of patients who rated their global quality of life as 'very good' or 'outstanding' was 51% and 41% among patients treated by IMRT and 3DCRT, respectively (p = 0.11). At 2 years, the corresponding percentages increased to 73% and 49%, respectively (p < 0.001). On multivariate analysis accounting for sex, age, radiation intent (definitive vs. postoperative), radiation dose, T stage, primary site, use of concurrent chemotherapy, and neck dissection, the use of IMRT was the only variable independently associated with improved quality of life (p = 0.01). Conclusion: The early quality of life improvements associated with IMRT not only are maintained but apparently become more magnified over time. These data provide powerful evidence attesting to the long-term benefits of IMRT for head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-74: Dosimetric Advantages of Adaptive Radiotherapy for Head and Neck Cancer Are Confirmed with Weekly CBCT Images

Purpose: Our previous study showed that weekly dose monitoring using cone-beam CT (CBCT) images can guide the timing and need for adaptive re-planning during the treatment of head and neck (HN) cancer. Here we aim to confirm the dosimetric improvement of adaptive radiotherapy (ART) using weekly CBCTs. Methods: We randomly selected seven HN patients treated with ART due to noticeable anatomic changes. Twenty weekly images acquired during the second treatment course were included. These CBCTs were aligned with both the initial and re-planning simulation CTs according to the clinical shifts. Daily doses were re-calculated for both the initial and adaptive plans. Contours of the tumor and organs-at-risk (OARs) were manually delineated by a physician on the re-planning CT and then were transferred to the CBCTs for plan evaluation. Contour modifications were made based on the daily anatomic changes observed on CBCTs. All patients were treated with 70Gy to the primary tumor and 56Gy to the elective lymph nodes. Results: Volumetric changes of the tumor (range — 43.9%∼+15.9%) were observed. The average D99 to the primary tumor was (70.1±2.0)Gy (range 62.2∼72.5Gy) for the adaptive plan and (66.0±5.5)Gy (range 50.9∼70.7Gy) for the initial plan(p<<0.01). The average D99 to the elective neck was (56.3±1.3)Gy (range 52.8∼59.2Gy) for the adaptive plan and (52.4±7.0)Gy (range 37.7∼58.6Gy) for the initial plan(p=0.01). The parotid decreased in volume during the treatment course (range 7.3%∼42.2%). The average D-mean to the spared parotid decreased by 15.3% (p=0.002) for the adaptive plan when compared to the original. With ART, 4 out of 7 patients experienced better sparing of the spinal cord (D-max reduced by 2.5%∼10.2%) and the oral cavity (D-mean reduced by 3.5%∼20.1%). Conclusion: Weekly CBCT dosimetry confirms that ART is an effective method to accommodate on-treatment anatomic changes. In select patients, tumor coverage and OAR sparing may be improved with ART. Research is funded by Siemens.

60 APPLIED LIFE SCIENCES↗

Characterizing Fit Factor of a One Size Fits-Most Emergency Mask using Subjects with Smaller Neck Circumferences

The Emergency Mask (EM) is an integral part of fire response on ISS, Orion and Gateway. The EM is a hood type protection respirator sealing around the subject’s neck, with an additional nose cup covering the subject’s oral nasal region. When integrated with a pair of Fire Cartridges (FCs), this system can be used to provide safe breathing air in a post-fire environment. The initial EM was certified as a ‘one size fits most’, however a recent requirements scrub discovered that the neck circumferences of the smallest possible crew population were not included in the initial requirement set. The test described in this paper uses the same slightly modified industry standard respirator test called a ‘Fit Factor’ used to certify the existing EM for larger subjects. Tests were performed on eight test subjects with neck circumference smaller than the initial EM requirement to determine if the current EM provided adequate protection during post-fire scenarios. The test included subjects donning an EM and then performing a number of head movements in a tent filled with approximately 50,000 particles/cm3 of smoke particulate. During these motions, particulate measurements were obtained from within the EM and compared with particulate measurements in the surrounding environment to determine the protection the EM provided in a simulated post-fire environment. This paper provides descriptions of the test hardware, methodology and results, which have provided rationale to design and build an EM to accommodate subjects with smaller necks.

Respirator↗

DNA Double-Strand Break Analysis by {gamma}-H2AX Foci: A Useful Method for Determining the Overreactors to Radiation-Induced Acute Reactions Among Head-and-Neck Cancer Patients

Purpose: Interindividual variability in normal tissue toxicity during radiation therapy is a limiting factor for successful treatment. Predicting the risk of developing acute reactions before initiation of radiation therapy may have the benefit of opting for altered radiation therapy regimens to achieve minimal adverse effects with improved tumor cure. Methods and Materials: DNA double-strand break (DSB) induction and its repair kinetics in lymphocytes of head-and-neck cancer patients undergoing chemoradiation therapy was analyzed by counting {gamma}-H2AX foci, neutral comet assay, and a modified version of neutral filter elution assay. Acute normal tissue reactions were assessed by Radiation Therapy Oncology Group criteria. Results: The correlation between residual DSBs and the severity of acute reactions demonstrated that residual {gamma}-H2AX foci in head-and-neck cancer patients increased with the severity of oral mucositis and skin reaction. Conclusions: Our results suggest that {gamma}-H2AX analysis may have predictive implications for identifying the overreactors to mucositis and skin reactions among head-and-neck cancer patients prior to initiation of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of brittle deformation under extension on Venus

The development of fractures at regular length scales is a widespread feature of Venusian tectonics. Models of lithospheric deformation under extension based on non-Newtonian viscous flow and brittle-plastic flow develop localized failure at preferred wavelengths that depend on lithospheric thickness and stratification. The characteristic wavelengths seen in rift zones and tessera can therefore provide constraints on crustal and thermal structure. Analytic solutions were obtained for growth rates in infinitesimal perturbations imposed on a one-dimensional, layered rheology. Brittle layers were approximated by perfectly-plastic, uniform strength, overlying ductile layers exhibiting thermally-activated power-law creep. This study investigates the formation of faults under finite amounts of extension, employing a finite-element approach. Our model incorporates non-linear viscous rheology and a Coulomb failure envelope. An initial perturbation in crustal thickness gives rise to necking instabilities. A small amount of velocity weakening serves to localize deformation into planar regions of high strain rate. Such planes are analogous to normal faults seen in terrestrial rift zones. These 'faults' evolve to low angle under finite extension. Fault spacing, orientation and location, and the depth to the brittle-ductile transition, depend in a complex way on lateral variations in crustal thickness. In general, we find that multiple wavelengths of deformation can arise from the interaction of crustal and mantle lithosphere.

Neumann, G. A.↗

Effects of weightlessness on human baroreflex function

Impaired cardiovascular function, characterized by orthostatic intolerance and reduced exercise capacity, is a result of space travel. We hypothesized that postflight baroreflex dysfunction may contribute. We studied the vagally mediated carotid baroreceptor-cardiac reflex response of 6 astronauts before, during, and after the ten day SLS-l mission. A series of R-waves triggered pressure and suction steps (from 40 to minus 65 mmHg) were delivered to a neck chamber during held expirtation. Resulting R-R interval changes were plotted against carotid distending pressure (systolic - neck pressure), and curve parameters calculated. After an initial rise, the operational point declined consistently during the flight and reached a nadir on landing day, but had recovered to preflight levels by L + 4. Slope and range of the response declined throughout the flight, were slightly recovered by the time measurements were made on landing day, but still were reduced on L + 4. These data indicate that space flight results in a significant impairment of the carotid baroreceptor cardiac reflex response.

Fritsch, Janice M.↗

A Computational Model for Simulating Spaceflight Induced Bone Remodeling

An overview of an initial development of a model of bone loss due to skeletal unloading in weight bearing sites is presented. The skeletal site chosen for the initial application of the model is the femoral neck region because hip fractures can be debilitating to the overall performance health of astronauts. The paper begins with the motivation for developing such a model of the time course of change in bone in order to understand the mechanism of bone demineralization experienced by astronauts in microgravity, to quantify the health risk, and to establish countermeasures. Following this, a general description of a mathematical formulation of the process of bone remodeling is discussed. Equations governing the rate of change of mineralized bone volume fraction and active osteoclast and osteoblast are illustrated. Some of the physiology of bone remodeling, the theory of how imbalance in remodeling can cause bone loss, and how the model attempts to capture this is discussed. The results of a preliminary validation analysis that was carried out are presented. The analysis compares a set of simulation results against bone loss data from control subjects who participated in two different bed rest studies. Finally, the paper concludes with outlining the current limitations and caveats of the model, and planned future work to enhance the state of the model.

Pennline, James A.↗

Temporal Nodal Regression and Regional Control After Primary Radiation Therapy for N2-N3 Head-and-Neck Cancer Stratified by HPV Status

Purpose: To compare the temporal lymph node (LN) regression and regional control (RC) after primary chemoradiation therapy/radiation therapy in human papillomavirus-related [HPV(+)] versus human papillomavirus-unrelated [HPV(−)] head-and-neck cancer (HNC). Methods and Materials: All cases of N2-N3 HNC treated with radiation therapy/chemoradiation therapy between 2003 and 2009 were reviewed. Human papillomavirus status was ascertained by p16 staining on all available oropharyngeal cancers. Larynx/hypopharynx cancers were considered HPV(−). Initial radiologic complete nodal response (CR) (≤1.0 cm 8-12 weeks after treatment), ultimate LN resolution, and RC were compared between HPV(+) and HPV(−) HNC. Multivariate analysis identified outcome predictors. Results: A total of 257 HPV(+) and 236 HPV(−) HNCs were identified. The initial LN size was larger (mean, 2.9 cm vs 2.5 cm; P<.01) with a higher proportion of cystic LNs (38% vs 6%, P<.01) in HPV(+) versus HPV(−) HNC. CR was achieved is 125 HPV(+) HNCs (49%) and 129 HPV(−) HNCs (55%) (P=.18). The mean post treatment largest LN was 36% of the original size in the HPV(+) group and 41% in the HPV(−) group (P<.01). The actuarial LN resolution was similar in the HPV(+) and HPV(−) groups at 12 weeks (42% and 43%, respectively), but it was higher in the HPV(+) group than in the HPV(−) group at 36 weeks (90% vs 77%, P<.01). The median follow-up period was 3.6 years. The 3-year RC rate was higher in the HPV(−) CR cases versus non-CR cases (92% vs 63%, P<.01) but was not different in the HPV(+) CR cases versus non-CR cases (98% vs 92%, P=.14). On multivariate analysis, HPV(+) status predicted ultimate LN resolution (odds ratio, 1.4 [95% confidence interval, 1.1-1.7]; P<.01) and RC (hazard ratio, 0.3 [95% confidence interval 0.2-0.6]; P<.01). Conclusions: HPV(+) LNs involute more quickly than HPV(−) LNs but undergo a more prolonged process to eventual CR beyond the time of initial assessment at 8 to 12 weeks after treatment. Post radiation neck dissection is advisable for all non-CR HPV(−)/non-CR N3 HPV(+) cases, but it may be avoided for selected non-CR N2 HPV(+) cases with a significant LN involution if they can undergo continued imaging surveillance. The role of positron emission tomography for response assessment should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation of the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value of p16 Status on the Development of a Complete Response in Involved Oropharynx Cancer Neck Nodes After Cisplatin-Based Chemoradiation: A Secondary Analysis of NRG Oncology RTOG 0129

Purpose: To determine the relationship between p16 status and the regional response of patients with node-positive oropharynx cancer treated on NRG Oncology RTOG 0129. Methods and Materials: Patients with N1-N3 oropharynx cancer and known p16 status who underwent treatment on RTOG 0129 were analyzed. Pathologic complete response (pCR) rates in patients treated with a postchemoradiation neck dissection (with p16-positive or p16-negative cancer) were compared by Fisher exact test. Patients managed expectantly were compared with those treated with a neck dissection. Results: Ninety-nine (34%) of 292 patients with node-positive oropharynx cancer and known p16 status underwent a posttreatment neck dissection (p16-positive: n=69; p16-negative: n=30). The remaining 193 patients with malignant lymphadenopathy at diagnosis were observed. Neck dissection was performed a median of 70 (range, 17-169) days after completion of chemoradiation. Neither the pretreatment nodal stage (P=.71) nor the postradiation, pre-neck dissection clinical/radiographic neck assessment (P=.42) differed by p16 status. A pCR was more common among p16-positive patients (78%) than p16-negative patients (53%, P=.02) and was associated with a reduced incidence of local–regional failure (hazard ratio 0.33, P=.003). On multivariate analysis of local–regional failure, a test for interaction between pCR and p16 status was not significant (P=.37). One-hundred ninety-three (66%) of 292 of initially node-positive patients were managed without a posttreatment neck dissection. Development of a clinical (cCR) was not significantly influenced by p16-status (P=.42). Observed patients with a clinical nodal CR had disease control outcomes similar to those in patients with a pCR neck dissection. Conclusions: Patients with p16-positive tumors had significantly higher pCR and locoregional control rates than those with p16-negative tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Board Imaging Validation of Optically Guided Stereotactic Radiosurgery Positioning System for Conventionally Fractionated Radiotherapy for Paranasal Sinus and Skull Base Cancer

Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positional error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zero-G fluid mechanics in animal and man

Significant cardiovascular change occurs with spaceflight. Loss of normal hydrostatic pressure gradients (head-to-foot), present while upright on earth, results in significant headward fluid shift of vascular and interstitial fluids. The resultant fluid change also shifts the hydrostatic indifference point for the circulation. The persistent distention of neck veins and change in upper body tissue compliance initiates steps to adapt to and compensate for the sensed excess fluid. These result in a loss of intravascular volume through neuro-humoral mechanisms and the presence of a smaller heart size, leading to a state where the subject has a reduced adaptive capacity to stress, particularly to fluid shifts to the lower body as occurs when once again returning to earth. This article reviews what is known about the weightlessness-induced headward fluid shift and its effects on cardiovascular function.

Sandler, H.↗

Initial Results of a Phase I Dose-Escalation Trial of Concurrent and Maintenance Erlotinib and Reirradiation for Recurrent and New Primary Head-and-Neck Cancer

Purpose: To present the first report of a Phase I trial evaluating concurrent and maintenance erlotinib and reirradiation in patients with recurrent or secondary primary head-and-neck cancer (HNC). Methods and Materials: Patients with recurrent or new primary HNC with an interval of at least 6 months since prior radiation were eligible. Patients were treated in 3 sequential cohorts: Cohort I, 100 mg of erlotinib daily with reirradiation at 61.6 Gy in 28 fractions; Cohort II, 150 mg of erlotinib with 61.6 Gy in 28 fractions; and Cohort III, 150 mg of erlotinib with 66 Gy in 30 fractions. Maintenance erlotinib started immediately after reirradiation at 150 mg daily and was continued for 2 years or until disease progression or dose-limiting toxicity. Dose-limiting toxicities were defined as any Grade 4 or 5 toxicity or a toxicity-related delay in radiation therapy of greater than 7 days. Results: Fourteen patients were accrued, 3 to Cohort I, 4 to Cohort II, and 7 to Cohort III. Thirteen patients were evaluable for toxicity. Median follow-up was 8.4 months overall and 15.1 months for surviving patients. One patient had a dose-limiting toxicity in Cohort III. This patient declined initial percutaneous endoscopic gastrostomy tube placement, was hospitalized with Grade 3 dysphagia and aspiration, and required a delay in radiation therapy of greater than 7 days. No Grade 4 acute toxicity was observed. Acute Grade 3 toxicity occurred in 9 of 13 patients. No erlotinib-related toxicity of Grade 3 or greater was observed during maintenance therapy. One patient had Grade 5 carotid hemorrhage 6 months after reirradiation, and another patient had Grade 3 osteoradionecrosis. Conclusions: Reirradiation (66 Gy in 2.2 Gy fractions) with concurrent and maintenance erlotinib (150 mg daily) for recurrent or new primary HNC is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose dependence of mechanical properties in tantalum and tantalum alloys after low temperature irradiation

The dose dependence of mechanical properties was investigated for tantalum and tantalum alloys after low temperature irradiation. Miniature tensile specimens of three pure tantalum metals, ISIS Ta, Aesar Ta1, Aesar Ta2, and one tantalum alloy, Ta-1W, were irradiated by neutrons in the High Flux Isotope Reactor (HFIR) at ORNL to doses ranging from 0.00004 to 0.14 displacements per atom (dpa) in the temperature range 60 C 100 oC. Also, two tantalum-tungsten alloys, Ta-1W and Ta-10W, were irradiated by protons and spallation neutrons in the LANSCE facility at LANL to doses ranging from 0.7 to 7.5 dpa and from 0.7 to 25.2 dpa, respectively, in the temperature range 50 C 160 oC. Tensile tests were performed at room temperature and at 250oC at nominal strain rates of about 10-3 s-1. All neutron-irradiated materials underwent progressive irradiation hardening and loss of ductility with increasing dose. The ISIS Ta experienced embrittlement at 0.14 dpa, while the other metals retained significant necking ductility. Such a premature embrittlement in ISIS Ta is believed to be because of high initial oxygen concentrations picked up during a pre-irradiation anneal. The Ta-1W and Ta-10W specimens irradiated in spallation condition experienced prompt necking at yield since irradiation doses for those specimens were high ( 0.7 dpa). At the highest dose, 25.2 dpa, the Ta-10W alloy specimen broke with little necking strain. Among the test materials, the Ta-1W alloy displayed the best combination of strength and ductility. The plastic instability stress and true fracture stress were nearly independent of dose. Increasing test temperature decreased strength and delayed the onset of necking at yield.

36 MATERIALS SCIENCE↗

Changes of the transverse diameter and volume and dosimetry before the 25th fraction during the course of intensity-modulated radiation therapy (IMRT) for patients with nasopharyngeal carcinoma

To quantify changes of the transverse diameter and volume and dosimetry, and to illustrate the inferiority of non-replanning during intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) patients. Fifty-three NPC patients who received IMRT in 33 fractions were enrolled in this prospective trial. Before the 25th fraction, a new simulation computed tomography (CT) scan was acquired for all patients. The dose-volume histograms of the phantom plan were compared with the initial plan. Significant reduction of the transverse diameter of the nasopharyngeal, the neck, and 2 parotid glands volume was observed on second CT compared with the first CT (mean reduction 7.48 {+-} 4.45 mm, 6.80 {+-} 15.14 mm, 5.70 {+-} 6.26 mL, and 5.04 {+-} 5.85 mL, respectively; p < 0.01). The maximum dose and V-40 of the spinal cord, mean dose, and V30 of the left and right parotid, and V-50 of the brain stem were increased significantly in the phantom plan compared with the initial plan (mean increase 4.75 {+-} 5.55 Gy, 7.18 {+-} 10.07%, 4.51 {+-} 8.55 Gy, 6.59 {+-} 17.82%, 5.33 {+-} 8.55 Gy, 11.68 {+-} 17.11% and 1.48 {+-} 3.67%, respectively; p < 0.01). On the basis of dose constraint criterion in the RTOG0225 protocol, the dose of the normal critical structures for 52.83% (28/53) of the phantom plans were out of limit compared with 1.89% (1/53) of the initial plans (p < 0.0001). Because of the significant change in anatomy and dose before the 25th fraction during IMRT, replanning should be necessary during IMRT with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of pre-annealing on the uni- and bi-axial stretching behavior of poly(ethylene naphthalate) films

Effect of pre-annealing on stress and birefringence behavior of poly(ethylene naphthalate) (PEN) films during stretching and relaxation processes was investigated. Amorphous and non-oriented PEN films were pre-annealed under the conditions of different temperatures and periods. The pre-annealed films were stretched uniaxially or equi-biaxially and then relaxed at fixed length. It was found that pre-annealing did not cause any notable change for the initial behavior of refractive indices variation, whereas the behaviors after necking were significantly affected. Through the comparison between in-plane and out-of-plane birefringence and the analysis of wide-angle x-ray diffraction patterns of drawn films of both stretching modes, it was confirmed that the orientation of naphthalene ring in the film plane was enhanced by pre-annealing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ductile failure and damage localization in Al6061-T6 characterized by in situ X-ray computed tomography and neural network segmentation

Damage initiation and localization in uniaxial tension tests of an Al6061-T6 alloy are evaluated and quantified using in situ X-ray computed tomography and a neural network segmentation strategy. This segmentation strategy offers significant advantages over traditional thresholding in quantifying microstructural and damage evolution metrics. Void nucleation was observed to occur throughout the deformation process, whereas void volume did not grow significantly until later stages of deformation. Localized analysis determined that void nucleation begins in and around the necked region during the early stages of deformation, whereas limited damage nucleation occurs outside of the neck until late stages of deformation. Lastly, inhomogeneities in void and particle spacing in the initial undeformed state of the material are observed to correlate well with the location of damage localization and necking during deformation. These results provide new insights into the ductile failure of Al alloys and how preexisting defects influence damage and rupture.

36 MATERIALS SCIENCE↗