At least 55 records · Page 3

Power-to-Gas Systems for Active Load Management at EV Charging Sites with High DER Penetration

Intermittent renewable systems and increasing electric vehicle (EV) penetrations increase load intermittency—and will require expensive distribution system infrastructure upgrades. Power-to-gas (P2G) systems are highly controllable loads that can be modulated to regulate the net load behind the meter. In this work, we present an active load management approach using P2G systems to regulate the net load for an EV charging station with high penetrations of renewable generation. The system also validates the feasibility of the proposed approach using a 750-kW electrolyzer operated with the distribution system in a real-time power-hardware-in-the-loop test. Finally, we evaluate the impact of the size of the P2G system on its ability to regulate the net load.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

8760-Based Method for Representing Variable Generation Capacity Value in Capacity Expansion Models: Preprint

Capacity expansion models (CEMs) are widely used to evaluate the least-cost portfolio of electricity generators, transmission, and storage needed to reliably serve demand over the evolution of many years or decades. Various CEM formulations are used to evaluate systems ranging in scale from states or utility service territories to national or multi-national systems. CEMs can be computationally complex, and to achieve acceptable solve times, key parameters are often estimated using simplified methods. In this paper, we focus on two of these key parameters associated with the integration of variable generation (VG) resources: capacity value and curtailment. We first discuss common modeling simplifications used in CEMs to estimate capacity value and curtailment, many of which are based on a representative subset of hours that can miss important tail events or which require assumptions about the load and resource distributions that may not match actual distributions. We then present an alternate approach that captures key elements of chronological operation over all hours of the year without the computationally intensive economic dispatch optimization typically employed within more detailed operational models. The updated methodology characterizes the (1) contribution of VG to system capacity during high load and net load hours, (2) the curtailment level of VG, and (3) the potential reductions in curtailments enabled through deployment of storage and more flexible operation of select thermal generators. We apply this alternate methodology to an existing CEM, the Regional Energy Deployment System (ReEDS). Results demonstrate that this alternate approach provides more accurate estimates of capacity value and curtailments by explicitly capturing system interactions across all hours of the year. This approach could be applied more broadly to CEMs at many different scales where hourly resource and load data is available, greatly improving the representation of challenges associate with integration of variable generation resources.

14 SOLAR ENERGY↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

A Methodology to Analyze the Impact of 30-Minute Wind Scheduling on Load-Following Requirements

This paper proposes a new and systematic approach to investigating the impact of wind transfer between balancing authorities (BAs) with half-hour scheduling on load following requirements, which was traditionally scheduled on an hourly basis. The analysis is conducted for a few BAs in the Pacific Northwest of the U.S. that are described as source BAs (sending renewables) and sink BAs (receiving renewables). The main hypothesis is that if the source BA could schedule interchange for wind on a half-hourly basis, it would make the schedule follow its net load more closely. The scheduling change in the source BA is matched by adding the corresponding component to the net load in the sink BA. The load-following requirements are calculated as: (a) by the difference between the net load and modified schedule in the source BA, and (b) the difference between modified net load and unchanged hourly schedule in the sink BA. Results are presented as hourly upward and downward load following requirements in the source and sink BA, and compared with the results obtained with all generators scheduled on an hourly basis. Thus, the proposed method can effectively help utilities better understand the impact of 30-minute scheduling and make better business decisions.

Diao, Ruisheng↗

Investigation of Relevant Distribution System Representation With DG for Voltage Stability Margin Assessment

This paper emphasizes the importance of including unbalanced distribution systems for voltage stability studies in power systems. The paper aims to: discuss the various simulation methods for power system analysis; highlight the need for modeling unbalanced distribution system for accurate load margin assessment; demonstrate the influence of net-load unbalance (NLU) on voltage stability margin (VSM). We also share a T&D co-simulation interface with commercial power system solvers. The distribution system is evolving rapidly with high proliferation of distributed energy resources (DERs); these are not guaranteed to proliferate in a balanced manner and uncertainty resulting due to these DERs is well acknowledged. These uncertainties cannot be captured or visualized without representing the distribution system in detail along with the transmission system. We show the impact of proliferation of DERs in various 3-phase proportions on voltage stability margin through T&D co-simulation. We also study the impact of volt/VAR control on voltage stability margin. This analysis is only possible by representing the distribution system in detail through T&D co-simulation. In conclusion, higher percentage of net-load unbalance (NLU) in distribution system aggravates the voltage stability margin of the distribution system, which can further negatively influence the overall voltage stability margin of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of Behind-the-Meter Solar Generation by Integrating Physical with Statistical Models

Accurate estimation of solar photovoltaic (PV) generation is crucial for distribution grid control and optimization. Unfortunately, most of the residential solar PV installations are behind-the-meter. Thus, utilities only have access to the net load readings. This paper presents an unsupervised framework for estimating solar PV generation by disaggregating the net load readings. The proposed framework synergistically combines a physical PV system performance model with a statistical model for load estimation. Specifically, our algorithm iteratively estimates solar PV generation with a physical model and electric load with the Hidden Markov model regression. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is validated against net load and solar PV generation data gathered from residential customers located in Austin, Texas. The validation results show that our method reduces mean squared error by 44% compared to the state-of-the-art disaggregation algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Optimal Energy Storage Schedules for Load Leveling and Ramp Rate Control in Distribution Systems

Continued integration of distributed energy resources (DERs) into the grid, such as solar PVs, at a large-scale, contributes into the famous Duck Curve. New DER management algorithms are therefore deemed necessary to alleviate rapid variations within net load profiles of distribution systems. Herein this paper proposes a process to determine the optimal energy storage schedules for leveling the distribution circuit feederhead net load. A series of sensitivity analyses shows how the proposed method can be used to determine the optimal energy storage schedules with different capacities, state of charge requirements, and net load ramp rate limitations.

25 ENERGY STORAGE↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Methodology for Contextual Unit Commitment Using Regression Residuals

Day after day, system operators are faced with the challenge of taking unit commitment (UC) decisions under uncertain net load conditions. The standard operating procedure for taking UC decisions begins by leveraging auxiliary data on covariates (such as the day of the week or latest weather information) to generate a point prediction for net load, which is used in solving a deterministic UC problem. Such an approach, however, is known to deliver a notoriously poor out-of-sample (OOS) performance, as it completely disregards the stochastic nature of net load. While stochastic programming models explicitly represent uncertainty, they mostly do so using a generic set of scenarios that neglect covariate observations, squandering useful auxiliary data that could be harnessed to glean insights into uncertainty. In this article, we discuss a contextual stochastic optimization approach to UC, which effectively exploits covariate observations while explicitly assessing uncertainty so as to boost the OOS performance of UC decisions. The key thrust of our approach is to leverage regression models, along with their empirical residuals, to set up and solve sample average approximation problems. Not only do we prove that our approach satisfies the requisite conditions for asymptotic optimality and consistency laid out in (Kannan et al., 2022), but we also assess its performance on several case studies conducted using real-world data collected in California ISO and New York ISO grids. In conclusion, results show that the proposed approach can significantly improve OOS performance compared to alternative methods proposed in the literature under varying dataset sizes.

Yurdakul, Ogun↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings: Preprint

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Optimal Control of Constrained DERs

In this paper, a coordinated optimal control is designed to simultaneously satisfy multiple power system objectives at the distribution network level. With high penetration of renewables, traditional generation and control may not be enough to compensate for intermittent changes in net load. Dynamic coordination of battery storage devices and demand response at aggregated distributed energy resource (DER) sites becomes necessary to maintain power system operation, however, each dynamic power component operates at different time scales. Frequency stabilization can be achieved by designing optimal controls for traditional generation, storage devices and demand response. The proposed optimal controls naturally render frequency separation of these load balancing mechanisms. Given a 24-hour net load forecast, optimal tracking control inputs are designed subject to constraints of selected system elements to ensure optimal performance of the power system. Simulation results are presented and discussed.

Harvey, Roland↗

Operation-adversarial scenario generation

This paper proposes a modified conditional generative adversarial network (cGAN) model to generate net load scenarios for power systems that are statistically credible, conditioned by given labels (e.g., seasons), and, at the same time, “stressful” to the system operations and dispatch decisions. The measure of stress used in this paper is based on the operating cost increases due to net load changes. The proposed operation-adversarial cGAN (OA-cGAN) internalizes a DC optimal power flow model and seeks to maximize the operating cost and achieve a worst-case data generation. The training and testing stages employed in the proposed OA-cGAN use historical day-ahead net load forecast errors and has been implemented for the realistic NYISO 11-zone system. In conclusion, our numerical experiments demonstrate that the generated operation-adversarial forecast errors lead to more cost-effective and reliable dispatch decisions.

42 ENGINEERING↗

Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) - Beta Version [Slides]

Due to high fossil fuel imports, high electricity rates, an unreliable electricity grid, and 100% renewable electricity goals, demand response can play a crucial role for the Puerto Rico electricity grid. The Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) is a spreadsheet-based tool in which users can estimate the potential impacts of demand response, energy efficiency, and VRE and storage adoption in Puerto Rico from 2021 through 2040. The tool includes projections for solar, wind, and battery adoption based on released RFPs and energy targets (including Act-17 2019) to generate a projected net load profile for each hour through 2040. Based on user inputs and default assumptions, the tool also projects load profile impacts of demand response and energy efficiency, and is specifically focused on highlighting projected demand response technical potential. This demand response technical potential can be used by local utilities, regulators, program administrators, or researchers to help design demand response programs for larger impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Service Restoration Incorporating Unmonitored Automatic Voltage Controllers and Net Metered Loads

Islanded microgrids may experience voltage and frequency instability due to uncontrolled state changes of voltage regulation devices and inaccurate demand forecasts. Uncontrolled state changes can occur if optimal microgrid restoration and dispatch algorithms, used for generating control commands for distributed energy resources, do not incorporate the behavior of automatic controllers of voltage regulation devices. Inaccurate demand forecasts may be encountered since post-outage demand of behind-the-meter net metered (NM) loads can vary significantly from their historical NM profiles. Here, this paper proposes an optimization formulation which allows optimal control of voltage regulators and capacitor banks without remote control and communication capabilities. A generalized demand model for NM loads is proposed which incorporates the cold load pickup phenomenon and their time varying post-outage demand in accordance with the IEEE 1547 standard. The time dependent optimal control formulation and the NM demand model are integrated in a sequential microgrid restoration algorithm by linearization of the involved logic propositions. A detailed case study on the unbalanced IEEE 123-node test system in OpenDSS validates the effectiveness of the proposed approach.

30 DIRECT ENERGY CONVERSION↗

Variability in large-scale wind power generation: Variability in large-scale wind power generation

The paper demonstrates the characteristics of wind power variability and net load variability in multiple power systems based on real data from multiple years. Demonstrated characteristics include probability distribution for different ramp durations, seasonal and diurnal variability and low net load events. The comparison shows regions with low variability (Sweden, Spain and Germany), medium variability (Portugal, Ireland, Finland and Denmark) and regions with higher variability (Quebec, Bonneville Power Administration and Electric Reliability Council of Texas in North America; Gansu, Jilin and Liaoning in China; and Norway and offshore wind power in Denmark). For regions with low variability, the maximum 1 h wind ramps are below 10% of nominal capacity, and for regions with high variability, they may be close to 30%. Wind power variability is mainly explained by the extent of geographical spread, but also higher capacity factor causes higher variability. It was also shown how wind power ramps are autocorrelated and dependent on the operating output level. When wind power was concentrated in smaller area, there were outliers with high changes in wind output, which were not present in large areas with well-dispersed wind power.

17 WIND ENERGY↗