Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Coincidence Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

β − decay of exotic P and S isotopes with neutron number near 28

β - decay of very neutron-rich isotopes of P and S, studied at the National Superconducting Cyclotron Laboratory (NSCL) using the Beta Counting Station (BCS) consisting of a Double Sided Strip Detector surrounded by clovers detectors for observing delayed γ transitions is reported here. β-decay half-lifes and delayed neutron emission probabilities were extracted for 42,43,44 P and 44,46 S by analyzing spatial and temporal correlations between implants and decay events in the Si detector with further coincidence with γ transitions. Detection of delayed γ rays allowed for the identification of negative parity 1p1h states in 42 S for the first time, also constraining the parent ( 42 P) spin/parity to 2 - or 3 - . For the most exotic isotope studied, 46 S, no strong γ transition was observed unlike lighter even-even S isotopes, thus implying the shift of Gamow Teller (GT) strength distribution to higher energies. In conclusion, comparison of experimental observations to detailed shell-model calculations using the SDPFSDG-MU interaction allowed us to infer the importance and role of First Forbidden (FF) β transitions as the neutron number approaches and then exceeds N = 28.

39 ≤ A ≤ 58↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

New Experiments for Detecting Emissions from Fission

Ensuring that nuclear science and technology is used solely for peaceful purposes is one of the most pressing challenges facing our society. The Consortium for Monitoring, Technology, and Verification (MTV) mission is to help meet this challenge by providing advanced technology and trained talent for careers in nuclear security and nonproliferation. The study of nuclear fission is one area of interest in the MTV. We are performing new experiments for the characterization of neutron and gamma ray emissions from fission fragments. These emissions are signatures for the detection and characterization of nuclear materials. To perform these experiments, we have developed Fission Sphere (FS-3), an array of forty organic stilbene detectors operated in time-coincidence. The FS-3 is used to measure the prompt emissions of neutrons and gamma rays from Cf-252 spontaneous fission. These new data will be used to validate physics-based prediction codes, including CGMF and FREYA, and will be useful in future ENDF and ENSDF evaluations. This paper will present results from the first experiments using FS-3 and a Cf-252 spontaneous fission source. It will compare the experimental results with predictions from theory and Monte Carlo simulation. Specifically, we will describe the correlations among energy, multiplicity, and angles of emitted particles. We will also discuss the application of these correlations in multiplicity counting techniques, which are widely used in nuclear safeguards.

Pozzi, S. A.↗

Quick Look Report of Godiva U233 shot March 2022 Data Collection Activities

This report discussing the March 2022 irradiation of U233 on the Godiva critical assembly using burst mode and subsequent analysis of the fission products starting at 65 minutes post irradiation, and ending 12 days later. The Short-Lived Fission Product Yield (SLFPY) project is one of many efforts under the Nuclear Physics Multi-Lab and related Venture Project. The objective of the SLFPY project is to provide improved measurements of fission product yields for select nuclides. The SLFPY project consists of measurement and analysis campaigns. To produce fission data, samples of actinide material are irradiated in a high-flux neutron environment. These samples are quickly placed in front of a detection system where both gamma singles and coincidence spectra are collected as a function of time. Gamma spectroscopy is performed on the irradiated material on site near the irradiation facility, starting as soon as feasible after the irradiation and continuing for 7 days or longer. Following the data collection, time-dependent fission yield analyses are performed using gamma-ray spectroscopy. This document summarizes the measurement campaign performed March 21 - April 4, 2022 where sub-gram quantities of 233 U nitrate (UO 2 (NO 3 ) 2 ) were irradiated in the Godiva reactor. The Godiva burst #2076 conducted under experiment IER 504 had a temperature change of +156 degrees Celsius, lasted 13.32 microseconds, and had a reactivity of $\$$1.089. The targets consisted of uranium oxide solution deposited in a quartz tube and packed with quartz wool. The flame-sealed quartz ampoules were used to contain the uranium samples for the irradiation and count activities. On March 22, 2022, at 10:27:00 a.m. the three uranium ampoules, along with a witness foil pack, were irradiated in the Godiva critical assembly using burst mode operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗