Uncertainty analysis of Response Functions and y-Backgrounds on Tion and t0 Measurements from Cherenkov Neutron Detectors at the National Ignition Facility (NIF) a)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Solid-state thermal neutron detectors are desired to replace {sup 3}He tube based technology for the detection of special nuclear materials. {sup 3}He tubes have some issues with stability, sensitivity to microphonics and very recently, a shortage of {sup 3}He. There are numerous solid-state approaches being investigated that utilize various architectures and material combinations. By using the combination of high-aspect-ratio silicon PIN pillars, which are 2 {micro}m wide with a 2 {micro}m separation, arranged in a square matrix, and surrounded by {sup 10}B, the neutron converter material, a high efficiency thermal neutron detector is possible. Besides intrinsic neutron detection efficiency, neutron to gamma discrimination is an important figure of merit for unambiguous signal identification. In this work, theoretical calculations and experimental measurements are conducted to determine the effect of structure design of pillar structured thermal neutron detectors including: intrinsic layer thickness, pillar height, substrate doping and incident gamma energy on neutron to gamma discrimination.
A tube-style neutron detector, a panel-style neutron detector incorporating a plurality of tube-style neutron detectors, and a panel-style neutron detector including a plurality of anode wires are provided. A plurality of channels is provided in a neutron detector such that each channel has an inner surface of a coating layer including a neutron-absorbing material. A wire anode is provided at end of each channel so that electrons generated by a charged daughter particle generated by a neutron are collected to detect a neutron-matter interaction. Moderator units can be incorporated into a neutron detector to provide improved detection efficiencies and/or to determine neutron energy spectrum. Gas-based proportional response from the neutron detectors can be employed for special nuclear material (SNM) detection. This neutron detector can provide similar performance to .sup.3He-based detectors without requiring .sup.3He and without containing toxic, flammable, or high-pressure materials.
Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.
A directional neutron detector has an ion chamber formed in a dielectric material; a signal electrode and a ground electrode formed in the ion chamber; a neutron absorbing material filling the ion chamber; readout circuitry which is electrically coupled to the signal and ground electrodes; and a signal processor electrically coupled to the readout circuitry. The ion chamber has a pair of substantially planar electrode surfaces. The chamber pressure of the neutron absorbing material is selected such that the reaction particle ion trail length for neutrons absorbed by the neutron absorbing material is equal to or less than the distance between the electrode surfaces. The signal processor is adapted to determine a path angle for each absorbed neutron based on the rise time of the corresponding pulse in a time-varying detector signal.
The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.
The detection of fast neutrons is regarded technically challenging because the interaction probability of fast neutron with matter is extremely low. Based on our recent development of hexagonal boron nitride (BN) semiconductor thermal neutron detectors with a record high efficiency of 59%, we report here the feasibility studies of BN detectors for detecting fast neutrons. A BN detector with a detection area of 2.1 cm 2 was fabricated from a 90 $μ$m thick BN epilayer. In the presence of a bare Cf-252 source emitting fast neutrons ranging from 1 to 9 MeV, the detection efficiency was estimated to be about 0.1%. Furthermore, the measured mean free path of fast neutron in BN is about 7.6 cm. Together with the capability of BN for thermal neutron detection, the present results indicate that by incorporating BN with a large thickness, BN neutron detectors are expected to possess the unique capability of directly detecting thermal to fast neutrons as well as outstanding features resulting from the ultrawide bandgap of BN. The identification of a single material that is sensitive to both thermal and fast neutrons is valuable for the development of novel neutron detection technologies.
In this study, a new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with multi-neutron (denoted Xn) Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interaction position within the active volume. A design study has been conducted based on simulations and experimental tests leading to the construction of prototype units. First results from measurements using a 252 Cf neutron source and accelerator-produced monoenergetic neutrons are presented.
Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)
This report describes different methodologies to calculate the effective neutron multiplication factor of subcritical assemblies by processing the neutron detector signals using MATLAB scripts. The subcritical assembly can be driven either by a spontaneous fission neutron source (e.g. californium) or by a neutron source generated from the interactions of accelerated particles with target materials. In the latter case, when the particle accelerator operates in a pulsed mode, the signals are typically stored into two files. One file contains the time when neutron reactions occur and the other contains the times when the neutron pulses start. In both files, the time is given by an integer representing the number of time bins since the start of the counting. These signal files are used to construct the neutron count distribution from a single neutron pulse. The built-in functions of MATLAB are used to calculate the effective neutron multiplication factor through the application of the prompt decay fitting or the area method to the neutron count distribution. If the subcritical assembly is driven by a spontaneous fission neutron source, then the effective multiplication factor can be evaluated either using the prompt neutron decay constant obtained from Rossi or Feynman distributions or the Modified Source Multiplication (MSM) method.
We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10{sup 6} and 10{sup 12} per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.
– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.
Here, neutron detectors fabricated from 10B enriched hexagonal boron nitride (h- 10 BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors to date at about 53%. In this work, photoconductive-like vertical detectors with a detection area of 1 × 1 mm 2 were fabricated from 50 μm thick free-standing h-BN epilayers using Ni/Au and Ti/Al bilayers as ohmic contacts. Leakage currents, mobility-lifetime (μτ) products under UV photoexcitation, and neutron detection efficiencies have been measured for a total of 16 different device configurations. The results have unambiguously identified that detectors incorporating the Ni/Au bilayer on both surfaces as ohmic contacts and using the negatively biased top surface for neutron irradiation are the most desired device configurations. It was noted that high growth temperatures of h- 10 BN epilayers on sapphire substrates tend to yield a higher concentration of oxygen impurities near the bottom surface, leading to a better device performance by the chosen top surface for irradiation than by the bottom. Preferential scattering of oxygen donors tends to reduce the mobility of holes more than that of electrons, making the biasing scheme with the ability of rapidly extracting holes at the irradiated surface while leaving the electrons to travel a large average distance inside the detector at a preferred choice. When measured against a calibrated 6 LiF filled micro-structured semiconductor neutron detector, it was shown that the optimized configuration has pushed the detection efficiency of h-BN neutron detectors to 58%. These detailed studies also provided a better understanding of growth-mediated impurities in h-BN epilayers and their effects on the charge collection and neutron detection efficiencies.
The goal of this project is to build upon the work performed under the Texas Tech IDEAS project (DE-AR0000964 monitored by Dr. Isik Kizilyalli) to bring the developed B-10 enriched hexagonal boron nitride (h- 10 BN or 10 BN or BN) semiconductor neutron detector technology to the next level of maturity. In comparison to He-3 ( 3 He) gas detectors, BN neutron detectors possess all the intrinsic advantages of semiconductor devices: light weight, compact size, fast response speed, high spatial resolution, high temperature and low voltage operation capability, ease of mass production via existing semiconductor infrastructures, low cost of operation and maintenance, flexible form factors, and durability. The project will develop a prototype h- 10 BN neutron detector as a potential replacement for the 3 He gas neutron detectors (LND 25185 or equivalent) used in various neutron survey meters currently produced and commercialized by Ludlum Measurements, Inc. (LMI). To increase the overall detection efficiency, it is essential to maximize the collection efficiency of charge carriers (electrons and holes) generated by the nuclear reaction, which demands a further push to achieve 10 BN epilayers with improved material quality. The material growth processes will be guided by characterization of structural, optical, and electrical properties of h-BN. Selective devices will be calibrated at LMI. During ARPA-E supporting period, the key material parameters of h-BN produced by metal organic chemical vapor deposition (MOCVD), including the layer thickness, mobility-lifetime product, surface recombination field and detector size for maintaining a high charge collection efficiency all have been improved by several orders of magnitude. These improvements have enabled the realization of high-performance h 10BN semiconductor thermal neutron detectors. Presently, h- 10 BN thermal neutron detectors developed under ARPA-E’s support hold the record high detection efficiency among all solid-state detectors at 59%. With further development in manufacturing, there is no question that h-BN detectors will replace the traditional He-3 gas detectors in certain application areas by offering obvious advantages of semiconductor technologies over gas detectors and opportunities for users to dedicate the scarce and expensive supply of He-3 gas to other application areas where substitutes of He-3 gas are not possible.
The development of new neutron detectors to replace helium-3 (3He) detectors is imperative due to a worldwide shortage of 3He following the draw down in nuclear weapons production since the end of the Cold War. The United States Department of Homeland Security would like to deploy monitors for the detection of neutron emissions from shipping containers housing illicit nuclear material; however, this effort has been put on hold until new replacements for 3He detectors can be developed. Scintillation Hydro-Gel for isotopic Neutron Emitters (SHINE) is a unique, first of its kind, 6Li-loaded quantum dot gel scintillator developed at INL. By incorporating 6Li with quantum dots in a gel matrix, SHINE displays the best properties of liquid and solid scintillators without their disadvantages such as continuous filtering to keep liquids free of contaminates, slow throughput of containers, higher base component costs, ‘dead’ voids in solid scintillators, and a high loading of 6Li without compromising on light transparency. Additionally, SHINE is completely eco-friendly, a breakthrough in high-efficiency detection systems. SHINE is a unique combination of 6LiCl, a highly water-soluble compound, and InP/ZnS core/shell quantum dots, which are poured into a gel-form using cross-linking polymers. In this presentation, SHINE has been successfully tested for neutron detection and shows promise as both a replacement for current 3He neutron detectors as well as potential use in handheld, compact neutron detection units and antineutrino detection.
The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory is being restored to support the mission of advanced reactor and fuel development in the United States. A key part of this restoration is the fast neutron hodoscope which images the fuel under test during extreme transient conditions. Traditionally, this has been comprised of ZnS (Ag)-based proton recoil scintillators (PRS) coupled to photomultiplier tubes (PMTs), but silicon photomultipliers (SiPMs) have emerged as a promising candidate to replace PMTs in this application. This work develops, tests, and evaluates a SiPM-based PRS detector for incorporation into the updated Fuel Motion Monitoring System (FMMS) at TREAT. The primary characteristic to be optimized is the gamma rejection efficiency of the detector which will be done using pulse shape discrimination (PSD). To do so multiple types of SiPMs will be tested with multiple PRS buttons and compared using standard PSD figures of merit. Consideration to count rates will also be given and consequently to the detector’s electrical time constants. Once the ideal SiPM has been selected for the PRS detectors, its gamma rejection efficiency will be characterized, and benchmarked to the traditional PMT-PRS detectors. PSD performance for this detector will also be characterized as a function of temperature.
Purpose: A rhodium self-powered neutron detector (Rh SPND) has been specifically developed by the Comision Nacional de Energia Atomica (CNEA) of Argentina to measure locally and in real time thermal neutron fluxes in patients treated with boron neutron capture therapy (BNCT). In this work, the thermal and epithermal neutron response of the Rh SPND was evaluated by studying the detector response to two different reactor spectra. In addition, during clinical trials of the BNCT Project of the CNEA, on-line neutron flux measurements using the specially designed detector were assessed. Methods: The first calibration of the detector was done with the well-thermalized neutron spectrum of the CNEA RA-3 reactor thermal column. For this purpose, the reactor spectrum was approximated by a Maxwell-Boltzmann distribution in the thermal energy range. The second calibration was done at different positions along the central axis of a water-filled cylindrical phantom, placed in the mixed thermal-epithermal neutron beam of CNEA RA-6 reactor. In this latter case, the RA-6 neutron spectrum had been well characterized by both calculation and measurement, and it presented some marked differences with the ideal spectrum considered for SPND calibrations at RA-3. In addition, the RA-6 neutron spectrum varied with depth in the water phantom and thus the percentage of the epithermal contribution to the total neutron flux changed at each measurement location. Local (one point-position) and global (several points-positions) and thermal and mixed-field thermal neutron sensitivities were determined from these measurements. Thermal neutron flux was also measured during BNCT clinical trials within the irradiation fields incident on the patients. In order to achieve this, the detector was placed on patient's skin at dosimetric reference points for each one of the fields. System stability was adequate for this kind of measurement. Results: Local mixed-field thermal neutron sensitivities and global thermal and mixed-field thermal neutron sensitivities derived from measurements performed at the RA-6 were compared and no significant differences were found. Global RA-6-based thermal neutron sensitivity showed agreement with pure thermal neutron sensitivity measurements performed in the RA-3 spectrum. Additionally, the detector response proved nearly unchanged by differences in neutron spectra from real (RA-6 BNCT beam) and ideal (considered for calibration calculations at RA-3) neutron source descriptions. The results confirm that the special design of the Rh SPND can be considered as having a pure thermal response for neutron spectra with epithermal-to-thermal flux ratios up to 12%. In addition, the linear response of the detector to thermal flux allows the use of a mixed-field thermal neutron sensitivity of 1.95 {+-} 0.05 x 10{sup -21} A n{sup -1}{center_dot}cm{sup 2}{center_dot}s. This sensitivity can be used in spectra with up to 21% epithermal-to-thermal flux ratio without significant error due to epithermal neutron and gamma induced effects. The values of the measured fluxes in clinical applications had discrepancies with calculated results that were in the range of -25% to +30%, which shows the importance of a local on-line independent measurement as part of a treatment planning quality control system. Conclusions: The usefulness of the CNEA Rh SPND for the on-line local measurement of thermal neutron flux on BNCT patients has been demonstrated based on an appropriate neutron spectra calibration and clinical applications.
Abstract Not Provided