Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ndi

The Nuclear Data Interface (NDI) is an application programming interface (API) that allows access to standard nuclear data parameters while hiding the underlying details of the data libraries and their storage. It allows access to multigroup transport data (neutron and gamma), thermonuclear burn data, dosimetry data, production/depletion chain data, radiochemistry data, and secondary neutron multiplicity data. The name NDI refers to both the code and data formats supported by the code.

Saller, Thomas↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Final Report DE-SC0020773

The DOE/NNSA sought development of innovative portable neutron/x-ray cameras for imaging and, when coupled with a portable source, also for radiography. This project focused on developing such a device that promises to have excellent resolution, while also providing neutron/gamma separation. We developed an Application Specific Integrated Circuit (ASIC) to be employed in conjunction with existing sensor technologies and modern assembly techniques. The concepts developed were a combination of new novel techniques and an innovative implementation of existing methods boosted by technological advances in ASIC performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative assessment of neutron flux sensor technologies for advanced reactors

This report documents the comparative assessment of the rhodium-based self-powered neutron detectors (Rh-SPND), micro-pocket fission detectors (MPFD), and dosimetry wires in heated irradiations at the Neutron Radiography reactor facility at Idaho National Laboratory. The sensors performances are evaluated high-temperature environments (upwards of 850°C) during maximum reactor power to simulate use in advanced reactor applications. The performance of the Rh-SPNDs indicates the experiment cartridge heater power supply interferes with the SPND signals. This interference become increasingly significant at temperatures above 500°C with minimal interference observed for temperatures below 500°C. This work also demonstrated the fabrication process for the updated design of the MPFD, but issues related to the seal welds were identified and usable data was limited. Finally, the dosimetry measurements were within the expected range correlated with reactor power; thus, the dosimetry results were used to provide preliminary SPND calibration factors. The results from this experiment serves as a reference for developing and testing of flux sensors that are designed for high-temperature irradiations and advanced reactor deployments. This includes upcoming FY22 irradiations at the Massachusetts Institute of Technology Reactor and the Neutron Radiography (NRAD) reactor utilizing additional fission chambers from Photonis Technologies and fission chambers and SPNDs from The French Alternative Energies and Atomic Energy Commission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation report on the Thermo Scientific TruDose (neutron,gamma) EPD3

This report summarizes an evaluation study on the Thermo Scientific TruDose n/γ EPD3 by LANL’s RP-SVS group. Two EPD3s were received for assessment (SNs 7500100 and 7500108) along with an EPD3 desktop reader. The evaluation included intercomparisons with Thermo’s N2 EPD which is in wide circulation at LANL but is no longer commercially available. A favourable assessment of the TruDose EPD3 would help support it as a viable option to replace the N2 EPD. The data and observations included in this report could also serve as the basis of a Technical Basis Document for the use of the EPD3 at LANL.

61 RADIATION PROTECTION AND DOSIMETRY↗

IRDFF-II: A New Neutron Metrology Library

High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60 MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new IRDFF-II library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. Additional six reference fields were assessed (four from plutonium critical assemblies, two measured fields for thermal-neutron induced fission on 233U and 239Pu targets) but not used for validation due to systematic discrepancies in C/E reaction rate values or lack of reaction-rate experimental data. Another ten analytical functions are included that can be useful for calculating average cross sections, average energy, thermal spectrum average cross sections and resonance integrals. The IRDFF-II library and comprehensive documentation is available online at www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.

IAEA IRDFF↗

Nuclear Criticality Safety Fundamentals [Slides]

Objectives of this presentation are: 1. Explain the difference between radiation safety vs. criticality safety, 2. Define criticality, 3. Explain the three types of chain reactions, 4. Define two terms scientists use to characterize criticality, 5. Explain what occurs during a criticality accident, 6. Identify prevention measures for avoiding a criticality accident, and 7. Identify the parameters that effect criticality of a system.

61 RADIATION PROTECTION AND DOSIMETRY↗

GaAs Neutron Response Functions and Radiation Damage Metrics

The radiation effects community needs clear, well-documented, neutron energy-dependent responses that can be used in assessing radiation-induced material damage to GaAs semiconductors and for correlating observed radiation-induced changes in the GaAs electronic properties with computed damage metrics. In support of the objective, this document provides: a) a clearly defined set of relevant neutron response functions for use in dosimetry applications; b) clear mathematical expressions for the defined response functions; and c) updated quantitative values for the energy- dependent response functions that reflect the best current nuclear data and modelling. This document recaps the legacy response functions. It then surveys the latest nuclear data and updates the recommended response function to support current GaAs damage studies. A detailed tabulation for six of the energy-dependent response functions is provided in an Appendix.

36 MATERIALS SCIENCE↗

A Review of the Lawrence Livermore Nuclear Accident Dosimeter 1980s-present

A Nuclear Accident Dosimetry program is a federal requirement for all facilities that have the potential to have a criticality accident. Personnel Nuclear Accident Dosimeter (PNAD) theory and analytical procedures are driven by various scientific needs and interacting regulations. A brief history of the status of USA Department of Energy (DOE) nuclear accident dosimetry regulations, recommendations, and performance testing criteria are given. Then, the history of the Lawrence Livermore National Laboratory (LLNL) PNAD is explored, including changes in the physical dosimeter and adjustments of the analysis method through the last four decades. Finally, the performance of LLNL’s PNAD at criticality accident intercomparison training exercises since 2009 is explored. In general, reported neutron doses have been within or close to DOE-STD-1098 performance criteria while reported gamma doses have been outside of DOE-STD-1098 performance criteria. Reported total absorbed doses have varied in meeting ANSI/HPS N13.3 and ANSI/HPS N13.3 (R2019) performance criteria. Dosimetry staff retirement and turnover have left historical knowledge gaps, yet provided opportunities within the NAD program at LLNL. This review paper serves as an overview of the history and status of the NAD program. Brief technical, procedural and programmatic recommendations to improve LLNL’s NAD program are given. Technical recommendations include investigating orientation factors through modeling or empirical experimentation, investigating gamma dosimetry methods for high-dose scenarios, and exploring other dosimetric methods for simpler, quicker NAD analysis. Procedural recommendations include better documentation of conversion factor (activity-to-fluence and fluence-to-dose) derivations and spectrum uses, and updated analysis spreadsheets or simple Graphic User Interfaces for dose calculations. In conclusion, programmatic recommendations include formalized training for NAD analysts, and having multiple SMEs trained on the NAD program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 252 Cf ⁢(sf) prompt fission neutron spectrum utilizing 12 C ⁡(𝑛, 𝑛) and 9 Be ⁢(𝑛, 𝑛) neutron scattering reference measurements

The 252 Cf spontaneous fission (sf), prompt fission neutron spectrum (PFNS) is a fundamental quantity for nuclear physics measurements of neutron-emitting reactions. This energy distribution of neutrons emitted from fission has been considered a neutron data standard for decades and has been utilized as a reference for neutron detection efficiency, validation of Monte Carlo simulations, benchmarking of dosimetry standards, and more. A significant portion of the global collection of nuclear data on neutron-induced reactions is correlated with the 252 Cf ⁢(sf) PFNS. Despite the reliance on this quantity by the nuclear physics community, the historical collection of 252 Cf PFNS measurements display systematic disagreements that are not understood or easily explained. These experimental discrepancies could potentially bias the 252 Cf PFNS Standard evaluation. On top of this, these past experiments frequently employed correlated experimental measurement or analysis methods. The artificial intelligence (AI)/machine learning (ML)-informed californium chi-nuclear data experiment (AIACHNE) project was formed to (a) investigate these discrepancies utilizing AI/ML methods to identify outlying regions of literature data, assign these regions to features of the experiment itself, and perform an improved evaluation of the 252 Cf PFNS and (b) perform a new experimental measurement of this quantity designed to improve upon the existing literature database. Here, in this work, we report on the AIACHNE 252 Cf PFNS experiment utilizing a new analysis method uncorrelated with all previous measurements: neutron efficiency determinations based on elastic neutron scattering on 12 C and 9 Be . This new method provides an independent test of the existing literature data and evaluation of the 252 Cf ⁢(sf) PFNS. The method is described with detailed covariance quantification procedures, as well as a direct discussion of the sources of uncertainty described as requirements in the “Templates” series of papers. The 252 Cf ⁢(sf) PFNS reported in this work agrees well with the overall shape of the existing standard PFNS evaluation as well as many literature measurements, thus verifying the current evaluation utilizing new techniques. However, the results suggest that there are deficiencies in the angle-differential 12 C and 9 Be ⁢(𝑛, 𝑛) evaluated nuclear data, which produce unphysical structures in the reported result. While these structures are relatively minor, they become obvious because of the high statistical precision of the data and the expected smooth continuity of the 252 Cf ⁢(sf) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fading study of Harshaw LiF:Mg,Ti thermoluminescence dosimeters exposed to neutron doses

Sensitivity and signal fading were tested in Harshaw LiF:Mg,Ti thermoluminescence dosimeters (TLDs) exposed to neutron and beta/photons doses. A significant difference in the signal fading rate was observed for TLDs exposed to neutrons compared with TLDs exposed to betas. This difference may have been related to differences in glow curves for dosimeters exposed to different beams and to differences in glow curve evolution after exposure. A fading-correction algorithm was developed to correct the cumulative sensitivity + signal fading of TL doses for the fading time t using the formulae: y = 0.147∗exp(-t/4.36) + 0.308∗exp(-t/34.1) + 0.73 for neutrons, and: y = 0.132∗exp(-t/10.72) + 0.174∗exp(-t/31.5) + 0.8 for betas/photons. The formula was validated using the dose recovery test, where the average deviation of fading-corrected doses from delivery doses was within 1%. In conclusion, the proposed fading-correction approaches may significantly improve the accuracy of Harshaw TL dosimetry with LiF:Mg,Ti cards for both neutron and beta/gamma irradiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of research reactor environments for validation of the IRDFF-II dosimetry cross section library

Activation data from seven different reactor-based reference neutron fields are examined to provide enhanced validation evidence for the newly released IRDFF-II library. A least-squares based spectrum adjustment methodology is used and rigorous statistical metrics demonstrate the consistency of the set of IRDFF-II dosimetry cross sections. The use of these reactor-based neutron fields provides validation evidence for nine more reactions than have been addressed in the 252 Cf(sf) and 235 U(th) benchmark validation testing. The use of covers to shift their energy response increases the power of the response validation but makes it challenging to properly capture response correlations.

Griffin, Patrick↗

High Flux Isotope Reactor Neutron Spectrum Shape Estimation From Activation Experiment Data

Here, this article provides a comprehensive review of historical irradiation dosimetry available for different locations within the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This article includes a summary of the available measured activation target data covering a span of over 15 years and 39 experimental campaigns, including 200 individual sample locations evaluated. Using this broad set of data, we reconstruct historic average neutron spectra shapes for HFIR at various locations, including within the flux trap region, beryllium reflectors, and hydraulic tube (HT) regions, at both the 100- and 85-MW operational power. Our findings indicate that the general axial flux distribution shows a relatively small change in transition from 100- to 85-MW operating power, with differences of -6% to +15% for the thermal energy range and around -16% to +8% for the fast range, indicating a sharper drop-off of the thermal neutron flux away from the axial center. Compared with historical dosimetry estimates of the HFIR flux shape, we generally find a moderately broader axial profile shape for thermal neutrons in the interior target regions for the 100-MW samples evaluated but relatively close agreement for the present 85-MW flux shape for both thermal and fast fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experiments for SINBAD: Evaluation of Oak Ridge Health Physics Research Reactor Operation Data for CAAS Benchmark Creation [Slides]

This report was a real information preservation and dissemination work with a lot of legacy content that was found and used. There was an abundance of uncertainty, discrepancy, and contradictory information. Yet, a detailed, functional SCALE model was built, and the benchmark created is useful for shielding and CAAs validation work. Sulfur fluence C/E ratios are large (2 to 5), so different benchmark metrics were studied. Neutron fluence, element 57 dose, and other dosimetry responses at 3 meters C/E ratios are below 1.5 for bare and steel configurations. Additional promising metrics as dose per unit fluence and steel shield attenuation were computed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗