Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Time Correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MPACT FY2011 Advanced Time-Correlated Measurement Research at INL

Simulations and experiments have been carried out to investigate advanced time-correlated measurement methods for characterizing and assaying nuclear material for safeguarding the nuclear fuel cycle. These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control Technologies (MPACT) program. For fiscal year 2011 work focused on examining the practical experimental aspects of using a time-tagged, associated-particle electronic neutron generator for interrogating low-enrichment uranium in combination with steady-state interrogation using a moderated 241Am-Li neutron source. Simulation work for the project involved the use of the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and the time-of-flight energy spectra of different sample materials under irradiation. Work also took place to develop a post-processor parser code to extract comparable data from the MCNP5&6 codes. Experiments took place using a commercial deuterium-tritium associated-particle electronic neutron generator to irradiate a number of uranium-bearing material samples. Time-correlated measurements of neutron and photon signatures of these measurements were made using five liquid scintillator detectors in a novel array, using high-speed waveform digitizers for data collection. This report summarizes the experiments that took place in FY2011, presents preliminary analyses that have been carried out to date for a subpart of these experiments, and describes future activities planned in this area. The report also describes support Idaho National Laboratory gave to Oak Ridge National Laboratory in 2011 to facilitate 2-dimensional imagery of mixed-oxide fuel pins for safeguards applications as a part of the MPACT program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Correlation Measurements of 252Cf Source Driven Fission Chains in Bare HEU Metal Assemblies

Passive multiplicity measurements of fissile metal assemblies are well established for measuring the multiplication, fissile content, and detection efficiency. In plutonium metal assemblies, most of the neutrons are unambiguously observed from fission chains because of the high spontaneous fission rate. However, uranium metal assemblies have low spontaneous fission rate such that the observed neutrons are a mixture of fission chain neutrons and cosmic-ray spallation neutrons. As a result, the multiplication, fissile content, and detection efficiency are difficult to measure without accurate quantification of the single neutron events unrelated to the fission chains. However, studying fission chains is simplified by knowing when each chain starts, which can be accomplished using a time-tagged active source such as a 252 Cf ionization chamber or a deuterium-tritium (D-T) neutron generator with an alpha detector. This paper presents time correlation measurements that have been performed with up to five 18 kg highly enriched uranium (HEU) storage castings and a 252 Cf ionization chamber placed near the center of each assembly. The measurements included liquid scintillators with pulse shape discrimination operating on the timescale of fission chains and 3 He proportional counters whose traditional use in multiplicity counting is well understood within a point-kinetics framework. Neutron time correlation distributions have been measured to characterize each assembly and are compared with the equivalent distributions collected passively.

252-Cf Ionization Chamber↗

Measurement of neutron and gamma-ray cross-correlation functions with 4 He detectors

For the first time, the neutron and gamma-ray time-dependent cross-correlation distributions from spontaneous fission and (α, n) neutron sources are measured with the 4 He fast neutron detectors. The pulse shape discrimination technique based on charge comparison is utilized to discriminate between neutrons and gamma-rays in the identification of the four possible correlated pairs: (γ, γ), (n, n), (γ, n), and (n, n). Both total and individual cross-correlation functions are obtained, and their shapes can be easily distinguished among different neutron sources. The (n, n) and (γ, n) correlations are selectively analyzed and the peak position of the (n, n) and (γ, n) pairs shows a linear correlation with source-detector distance. Here, the measurements illustrate the feasibility of using 4 He detectors to identify nuclear materials and their geometrical configurations, as well as other applications in nuclear nonproliferation and safeguards. In particular, the (n, n) correlated data can be very clearly assayed even in the presence of significant gamma fields without the use of shielding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method to measure the U-235 content in fresh LWR fuel assemblies via fast-neutron passive self-interrogation

The purpose of this paper is to provide a solution to a decades old safeguards problem in the verification of the fissile concentration in fresh light water reactor (LWR) fuel assemblies. The problem is that the burnable poison (e.g. Gd 2 O 3 ) addition to the fuel rods decreases the active neutron assay for the fuel assemblies. This paper presents a new innovative method for the verification of the 235 U linear mass density in fresh LEU fuel assemblies that is insensitive to the burnable poison content. The technique makes use of the 238 U atoms in the fuel rods to self-interrogate the 235 U mass. The innovation for the new approach is that the 238 U spontaneous fission (SF) neutrons from the rods induces fission reactions (IF) in the 235 U that are time correlated with the SF source neutrons. Thus, the coincidence gate counting rate benefits from both the nu-bar of the 238 U SF (2.07) and the 235 U IF (2.44) for a fraction of the IF reactions. Whereas, the 238 U SF background has no time-correlation boost. The higher the detection efficiency, the higher the correlated boost because background neutron counts from the SF are being converted to signal doubles. This time-correlation in the IF signal increases signal/background ratio that provides a good precision for the net signal from the 235 U mass. The hard neutron energy spectrum makes the technique insensitive to the burnable poison loading where a Cd or Gd liner on the detector walls is used to prevent thermal-neutron reflection back into the fuel assembly from the detector. Here, we have named the system the fast-neutron passive collar (FNPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gadolinium-doped water cerenkov-based neutron and high energy gamma-ray detector and radiation portal monitoring system

A water Cerenkov-based neutron and high energy gamma ray detector and radiation portal monitoring system using water doped with a Gadolinium (Gd)-based compound as the Cerenkov radiator. An optically opaque enclosure is provided surrounding a detection chamber filled with the Cerenkov radiator, and photomultipliers are optically connected to the detect Cerenkov radiation generated by the Cerenkov radiator from incident high energy gamma rays or gamma rays induced by neutron capture on the Gd of incident neutrons from a fission source. The PMT signals are then used to determine time correlations indicative of neutron multiplicity events characteristic of a fission source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the equivalence of the RTI and SVM approaches to time correlated analysis

Recently two papers on how to perform passive neutron auto-correlation analysis on time gated histograms formed from pulse train data, generically called time correlation analysis (TCA), have appeared in this journal [1,2]. For those of us working in international nuclear safeguards these treatments are of particular interest because passive neutron multiplicity counting is a widely deployed technique for the quantification of plutonium. The purpose of this letter is to show that the skewness-variance-mean (SVM) approach developed in [1] is equivalent in terms of assay capability to the random trigger interval (RTI) analysis laid out in [2]. Mathematically we could also use other numerical ways to extract the time correlated information from the histogram data including for example what we might call the mean, mean square, and mean cube approach. The important feature however, from the perspective of real world applications, is that the correlated information extracted is the same, and subsequently gets interpreted in the same way based on the same underlying physics model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Point model equations for neutron correlation counting: Extension of Böhnel's equations to any order

Various methods of autocorrelation neutron analysis may be used to extract information about a measurement item containing spontaneously fissioning material. The two predominant approaches being the time correlation analysis (that make use of a coincidence gate) methods of multiplicity shift register logic and Feynman sampling. The common feature is that the correlated nature of the pulse train can be described by a vector of reduced factorial multiplet rates. We call these singlets, doublets, triplets etc. Within the point reactor model the multiplet rates may be related to the properties of the item, the parameters of the detector, and basic nuclear data constants by a series of coupled algebraic equations – the so called point model equations. Solving, or inverting, the point model equations using experimental calibration model parameters is how assays of unknown items is performed. Currently only the first three multiplets are routinely used. In this work we develop the point model equations to higher order multiplets using the probability generating functions approach combined with the general derivative chain rule, the so called Faà di Bruno Formula. Explicit expression up to 5th order are provided, as well the general iterative formula to calculate any order. This study represents the first necessary step towards determining if higher order multiplets can add value to nondestructive measurement practice for nuclear materials control and accountancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron angular distribution in plutonium-240 spontaneous fission

Nuclear safeguards applications require accurate fission models that exhibit prompt neutron anisotropy. We observed an anisotropic neutron angular distribution, in the laboratory reference frame, because prompt fission neutrons carry momentum from fully accelerated fission fragments. Furthermore, a liquid organic scintillation detector array was used with pulse shape discrimination techniques to produce neutron-neutron cross-correlation time distributions and angular distributions from spontaneous fission in a 252 Cf, a 0.84 g 240 Pu eff metal, and a 1.63 g 240 Pu eff metal sample. The effect of cross-talk, estimated with MCNPX-PoliMi simulations, is removed from neutron-neutron coincidences as a function of the angle between detector pairs. Fewer coincidences were observed at detector angles near 90°, relative to higher and lower detector angles. As light output threshold increases, the observed anisotropy increases due to spectral effects arising from fission fragment momentum transfer to emitted neutrons. Stronger anisotropy was observed in Cf-252 spontaneous fission prompt neutrons than in Pu-240 neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Statistical Uncertainties in Subcritical Benchmark Measurements: Part I - Theory and Simulations

Subcritical neutron noise measurements are often used to determine multiplication of a system with Special Nuclear Material. This work presents an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism. This is a moments-based approach which utilizes time correlations between prompt neutrons in order to assess the system multiplication. After the method is described, a validation is presented which utilizes simulated data generated using a 0-D point-kinetics Monte Carlo code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advances in Neutron Spectroscopy and High Magnetic Field Instrumentation for studies of Correlated Electron Systems

Neutron Spectroscopy has provided critical information on the magnetism in correlated electron systems. Specifically quantum magnets, superconductors, and multi-ferroics are areas of productive research. A discussion of recent measurements on the SEQUOIA spectrometer will provide examples of how novel instrumentation concepts are used on the latest generation of spectrometers to extend our knowledge in such systems. The now ubiquitous function of sample rotation allows for full mapping of volumes of $Q$ and $\omega$ space. An instrument focused on low angles could extend these maps to cover more of the first Brillioun zone. Innovative chopper cascades allow two unique modes of operation. Multiplexed measurements allow the simultaneous measurement of high and low energy features in an excitation spectrum. Alternatively by limiting the neutron bandwidth incident on the Fermi Chopper, background from subsequent time frames is removed, enabling the observation of weak, large energy transfer features. Finally the implementation of event-based detection for neutron experiments is time correlated experiments. Diffraction studies of the high field spin states in MnWO$_4$ using magnetic fields up to 30 T, provided by a pulsed magnet, illustrate this method. Expanding the high field studies to spectroscopy will require a novel instrument, focused around a world class DC magnet, like Zeemans proposed for the SNS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A priori precision estimation for neutron triples counting

The nondestructive assay of Plutonium bearing items for criticality, safety, security, safeguards, inventory balance, process control, waste management and compliance is often undertaken using correlated neutron counting. In particular Multiplicity Shift Register analysis allows one to extract autocorrelation parameters from the pulse train which can, within the framework of a simple interpretational model, be related to the effective {sup 240}Pu spontaneous fission mass present. The effective {sup 240}Pu mass is a weighted sum of the {sup 238}Pu, {sup 240}Pu and {sup 242}Pu masses so if the relative isotopic composition of the Pu can be established from the measured {sup 240}Pu effective mass one can estimate the total Pu mass and also the masses of the individual isotopes, example the fissile species {sup 239}Pu and {sup 241}Pu. In multiplicity counting three counting rates are obtained. These are the Singles, Doubles and Triples rates. The Singles rate is just the gross, totals or trigger rate. The Doubles and Triples rates are calculated from factorial moments of the observed signal triggered neutron multiplicity distributions following spontaneous fission in the item and can be thought of as the rate of observed coincident pairs and coincident triplets on the pulse train. Coincident events come about because the spontaneous fission and induced fission chains taking place in the item result in bursts of neutrons. These remain time correlated during the detection process and so retain information, through the burst size distribution, about the Pu content. In designing and assessing the performance of a detector system to meet a given goal it is necessary to make a priori estimates of the counting precision for all three kinds of rates. This is non-trivial because the counting does not obey the familiar rules of a Poissonian counting experiment because the pulse train has time correlated events on it and the train is sampled by event triggered gates that may overlap. For Singles and Doubles simple approximate analytical empirical rules for how to estimate the variance have been developed guided by theory and refined by experiment. However, for Triples no equivalent rules have been put forward and tested until now. In this work we propose an analytical expression, the CSH relation, for the variance on the Triples count and exercise it against experimental data gathered for Pu items measured in the Los Alamos National Laboratory's Epithermal Neutron Multiplicity Counter (ENMC). Preliminary results are encouraging and reasonable agreement with observation, considered fit for scoping studies, is obtained. We have also looked at the behavior using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of statistical uncertainties in subcritical benchmark measurements: Part II – Measured data

Part I of this work presented an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism of the Feynman Variance-to-Mean method. This moments-based approach utilizes time correlations between prompt neutrons detections to assess the system multiplication. Additionally, it presented a validation which utilized simulated data generated using a 0-D point-kinetics Monte Carlo code. In Part II, this same method and validation approach is applied to measured data of a subcritical benchmark experiment. These measurements were performed with a 4.5 kg sphere of alpha-phase weapons grade plutonium reflected by copper and/or polyethylene. Finally, the results of 17 configurations are shown including detailed validation for four of the configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron emission generated during wire array Z-pinch implosion onto deuterated fiber

The implosion of both cylindrical and conical wire arrays onto a deuterated polyethylene fiber was studied on the S-300 pulsed power generator [A. S. Chernenko et al., Proceedings of the 11th International Conference on High Power Particle Beams (Academy of Science of Czech Republic, Prague, 1996), p. 154]. Neutron measurements were used to obtain information about acceleration of fast deuterons. An average neutron yield approached 10{sup 9} on the current level of 2 MA. In the case of conical wire arrays, side-on neutron energy spectra peaked at 2.48{+-}0.05 MeV with 450{+-}100 keV full width at half-maximum. In the downstream direction, the peak neutron energy and the width of a neutron spectrum were 2.65{+-}0.10 MeV and 350{+-}100 keV, respectively. The total number of fast deuterons was 10{sup 15} and their average kinetic energy was about 150 keV. Most of the deuterons were directed toward the cathode. The broad width of neutron spectra in the side-on direction implied a high radial component of deuteron velocity. With regard to the emission time, neutron pulses temporally correlated with hard x rays and also with measured voltage. The neutron emission lasted on average 30{+-}5 ns and it was observed during the stagnation and at the beginning of the expansion of a plasma column. At this moment, the plasma impedance reached 0.2-0.4 {omega}. In the post-stagnation phase, this value was formed significantly by enhanced plasma resistance. Similar experimental results were observed also with cylindrical wire arrays imploding onto a deuterated fiber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗