Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Effect of rhenium addition on deuterium retention in neutron-irradiated tungsten

In this work, the effects of rhenium (Re) addition on deuterium (D) retention in neutron-irradiated tungsten (W) were investigated. Pure W and W-5Re (5 at.%) alloy samples were irradiated with neutrons at High Flux Isotope Reactor using MFE-RB-19 J capsule. The sample temperature and the damage level were 864 K and 0.35 dpa for pure W and 792 K and 0.26 dpa for W-5Re alloy. A portion of the samples was exposed to D plasma at Tritium Plasma Experiment at Idaho National Laboratory at 823 K to a fluence of 5 × 1025 m -2 . Vacancy-type defects in neutron-irradiated samples were examined using positron annihilation spectroscopy (PAS); D retention after plasma exposure was evaluated by thermal desorption spectrometry (TDS). TDS measurements revealed that D retention in the neutron-irradiated W-5Re alloy was similar to that in the unirradiated W sample, whereas a significant increase in D retention was observed in neutron-irradiated W. Thus, Re addition significantly suppressed the increase in D retention after neutron irradiation. This effect was attributed to the suppression of vacancy-type defect formation, as confirmed by PAS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiological Characterization of Hard to Measure Nuclides Using Accelerator Mass Spectrometry (AMS) - 20140

In this project irradiated heavy concrete was characterized regarding hard to measure nuclides like Ca-41 using Accelerator Mass Spectrometry (AMS). Concrete samples were irradiated with a known neutron flux and the Ca-41 content was investigated via AMS measurements. The comparison of the results with calculations shows a very good agreement in the Ca-41 content. The project revealed that AMS can be used to characterize irradiated concrete and contributes to improve the methodological basis of the radiological characterization and to extending the validation of nuclide vectors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fission gas trapped in Chornobyl fuel microparticles reveals details of reactor operations

The isotopic ratios of fission gas would provide important source information of a nuclear fuel sample found in the environment. However, it is believed that during a reactor accident like Chornobyl all fission gas is lost and that the radioactive particles found in the Chornobyl Exclusion Zone today are depleted in gases by the initial explosion and subsequent fire. We disprove this hypothesis by detection and analysis of trapped krypton and xenon in these particles. Our analysis of krypton and xenon isotopes by noble gas mass spectroscopy in combination with resonance ionization mass spectrometry establishes that important information about reactor operations like age, neutron flux and plutonium fission fraction can still be reconstructed from individual micrometer-sized particles even after decades of weathering in the environment.

Chornobyl↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the In Vivo Deuteration of Native Phospholipids by Mass Spectrometry Yields Guidelines for Their Regiospecific Customization

Customization of deuterated biomolecules is vital for many advanced biological experiments including neutron scattering. However, because it is challenging to control the proportion and regiospecificity of deuterium incorporation in live systems, often only two or three synthetic lipids are mixed together to form simplistic model membranes. This limits the applicability and biological accuracy of the results generated with these synthetic membranes. Despite some limited prior examination of deuterating Escherichia coli lipids in vivo, this approach has not been widely implemented. In this report an extensive mass spectrometry-based profiling of E. coli phospholipid deuteration states with several different growth media was performed, and a computational method to describe deuterium distributions with a one-number summary is introduced. The deuteration states of 36 lipid species were quantitatively profiled in 15 different growth conditions, and tandem mass spectrometry was used to reveal deuterium localization. Regressions were employed to enable the prediction of lipid deuteration for untested conditions. Small-angle neutron scattering was performed on select deuterated lipid samples, which validated the deuteration states calculated from the mass spectral data. Based on these experiments, guidelines for the design of specifically deuterated phospholipids are described. This unlocks even greater capabilities from neutron-based techniques, enabling experiments that were formerly impossible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Domain crossover in the reductase subunit of NADPH-dependent assimilatory sulfite reductase

NADPH-dependent assimilatory sulfite reductase (SiR) from Escherichia coli performs a six-electron reduction of sulfite to the bioavailable sulfide. SiR is composed of a flavoprotein (SiRFP) reductase subunit and a hemoprotein (SiRHP) oxidase subunit. There is no known high-resolution structure of SiR or SiRFP, thus we do not yet fully understand how the subunits interact to perform their chemistry. Here, we used small-angle neutron scattering to understand the impact of conformationally restricting the highly mobile SiRFP octamer into an electron accepting (closed) or electron donating (open) conformation, showing that SiR remains active, flexible, and asymmetric even with these conformational restrictions. From these scattering data, we then model the first solution structure of SiRFP. Further, computational modeling of the N-terminal 52 amino acids that are responsible for SiRFP oligomerization suggests an eight-helical bundle tethers together the SiRFP subunits to form the SiR core. Finally, mass spectrometry analysis of the closed SiRFP variant show that SiRFP is capable of inter-molecular domain crossover, in which the electron donating domain from one polypeptide is able to interact directly with the electron accepting domain of another polypeptide. This structural characterization suggests that SiR performs its high-volume electron transfer through both inter- and intramolecular pathways between SiRFP domains and, thus, cis or trans transfer from reductase to oxidase subunits. Such highly redundant potential for electron transfer makes this system a potential target for designing synthetic enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Actinide Separation Inspired by Self-Assembled Metal–Polyphenolic Nanocages

The separation of actinides has a vital place in nuclear fuel reprocessing, recovery of radionuclides, and remediation of environmental contamination. Here we propose a new paradigm of nanocluster-based actinide separation, namely, nanoextraction, that can achieve efficient sequestration of uranium in an unprecedented form of giant coordination nanocages using a cone-shaped macrocyclic pyrogallol[4]arene as the extractant. The U 24 -based hexameric pyrogallol[4]arene nanocages with distinctive [U 2 (PG) 2 ] binuclear units (PG = pyrogallol) that rapidly assembled in situ in monophasic solvent were identified by single-crystal X-ray diffraction, MALDI-TOF mass spectrometry, NMR spectroscopy, and small-angle X-ray and neutron scattering. Furthermore, comprehensive biphasic extraction studies showed that this novel separation strategy has enticing advantages such as fast kinetics, high efficiency, and good selectivity over lanthanides, thereby demonstrating its potential for efficient separation of actinide ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-yield magnetic recoil neutron spectrometer on the National Ignition Facility for operation up to 60 MJ

We report that recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 x 10 17 , places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (T ion ), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 x 10 17 , and yield and T ion up to 2 x 10 18 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 x 10 19 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10x but also improve signal-to-background by 5x.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Design, calibration, and performance of a uniaxial pressure cell for neutron scattering studies of quantum magnetism

Here we provide an overview of a pressure cell designed to apply uniaxial pressure to single crystals for the study, by neutron scattering techniques, of strongly correlated magnetic systems and, in particular, quantum magnets. A detailed overview of the pressure cell components, their requirements, and links to the scientific and technical specifications are presented. The pressure cell is able to accommodate a 200 mm 3 single crystal that can be pressurized up to 2 GPa at cryogenic temperatures. The pressure cell is consistent with the requirements of inelastic neutron scattering and, importantly, neutron polarization analysis. A particular strength of the uniaxial pressure cell is the highly uniform and low background for a wide scattering angle of 360° horizontally and ±20° vertically. We show the performance of the uniaxial pressure cell using a relevant neutron scattering instrument, the polarized diffuse scattering instrument, D7. The experiments confirm that the cell complies with the scientific and technical requirements. This uniaxial pressure cell will provide a useful additional tool in the sample environment suite available for the study of quantum magnetism.

47 OTHER INSTRUMENTATION↗

The Kinetics of Aragonite Formation from Solution via Amorphous Calcium Carbonate

Magnesium doped Amorphous Calcium Carbonate was synthesised from precursor solutions containing varying amounts of calcium, magnesium, H2O and D2O. The Mg/Ca ratio in the resultant Amorphous Calcium Carbonate was found to vary linearly with the Mg/Ca ratio in the precursor solution. All samples crystallised as aragonite. No Mg was found in the final aragonite crystals. Changes in the Mg to Ca ratio were found to only marginally effect nucleation rates but strongly effect crystal growth rates. These results are consistent with a dissolution-reprecipitation model for aragonite formation via an Amorphous Calcium Carbonate intermediate.

36 MATERIALS SCIENCE↗

Nuclear mass measurements map the structure of atomic nuclei and accreting neutron stars

We introduce here mass excesses (ME) of neutron-rich isotopes of Ar through Fe, obtained via time of flight B ρ mass spectrometry at the National Superconducting Cyclotron Laboratory. Our new results have significantly reduced systematic uncertainties relative to a prior analysis, enabling the first determination of ME for Ti 58 , 59 , V 62 , Cr 65 , Mn 67 , 68 , and Fe 69 , 70 . Our results show the N = 34 subshell weaken at Sc and vanish at Ti, along with the absence of an N = 40 subshell at Mn. This further leads to a cooler accreted neutron star crust, highlighting the connection between the structure of nuclei and neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

β- and γ-Counting for Pre-detonation Nuclear Forensics on Eu-155

Post-detonation nuclear forensics was performed at Los Alamos National Laboratory (LANL) on 155Eu, a fission product on the wing of the fission product production curve whose yield is sensitive to fission fuel and neutron energy. With a half-life of 4.753 years, 155Eu provides a longer-lived option for these measurements than other fission products with similar mass numbers. The Chemistry Division Group - Nuclear and Radiochemistry, at LANL routinely measures a suite of fission products from 235U fissions in thermal neutron flux experiments known as thermal calibration exercises, using a mixture of gas proportional β-decay counting and γ-spectrometry on HPGe detectors. The fission products of interest are reported relative to a high-yield reference fission product from the same sample to create a running average ratio specific to neutron energy and fuel type; Equation 1 below shows the ratio-of-ratios R-value measured fission products are reported in: R i x = [A( i X)/A( 99 Mo)] unknown [A( i X)/A( 99 Mo)] 235 U n,th where A denotes activity, i X is the nuclide of interest, and 235 U n,th denotes irradiations of 235 U with thermal neutrons. Measurements of unknown fission spectra are ratioed to a running-average of thermal calibration results, and the resulting R-value can be referred to as against a library of irradiation conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First experimental determination of the ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar reaction cross section and ³⁹Ar production in Earth’s atmosphere

The cosmogenic ³⁹Ar(t1∕2 = 268 years) isotope of argon is used for geophysical dating and tracing of underground and ocean water, as well as ice owing to its appropriate half-life and chemical inertness as a noble gas; ³⁹Ar serves also in nuclear weapon test monitoring. We measured for the first time the total cross section of the main ³⁹Ar cosmogenic production reaction in the atmosphere, namely ⁴⁰Ar(𝑛, 2𝑛)39 Ar, using 14.8 ± 0.3 MeV neutrons. The neutrons, produced by a deuterium-tritium generator, impinged on a stainless steel sphere filled with Ar gas highly enriched in the ⁴⁰Ar isotope and were monitored by a stack of fast-neutron activation foils. The reaction yield was measured by atom counting of long-lived ³⁹Ar with noble gas accelerator mass spectrometry and, independently, by decay counting relative to atmospheric argon (³⁹Ar/Ar= 8.12 × 10−16 ). A total ⁴⁰Ar(𝑛, 2𝑛)39 Ar cross section of 610 ± 100 mb was determined at 14.8 ± 0.3 MeV incident neutron energy. This result serves as a benchmark for recent theoretical calculations and evaluations, found to reproduce well the experimental total cross section. We use these energy-dependent theoretical cross sections together with experimental spectra of cosmogenic neutrons at different altitudes to calculate the global average rate of neutron-induced ³⁹Ar atmospheric production, resulting in 770 ± 240 39 Ar atoms/cm²/day. The secular equilibrium between the ³⁹Ar calculated production rate and radioactive decay rate leads to a partial isotopic abundance ³⁹Ar/Ar = (5.9 ± 1.8) × 10−16 , showing that ≈73% of atmospheric ³⁹Ar is produced by cosmogenic neutrons, the remaining part believed to be induced by muons and high-energy 𝛾 rays. The ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar cross section at 14 MeV is also a key parameter for quantifying the anthropogenic contribution to atmospheric 39 Ar produced during the thermonuclear tests of the 1960s. We estimate that anthropogenic ³⁹Ar accounts for roughly 20% of the present atmospheric inventory.

39 Ar atmospheric production↗

Gamma-ray spectrometry as a tool for exploring archaeological nuclear facilities: a case study from the Nevada Test Site Nuclear Rocket Development Station

Since its first demonstration in the early 2000s, the exploration of gamma-ray spectrometry (GRS) applications as a geophysical tool in archaeology remains nascent. While intentional neutron activation, which requires a gamma-ray analysis, has seen increasing use as a geoforensics technique in archaeology, little or no research has been published concerning the possibility of GRS as an industrial archaeological tool for use in exploring nuclear sites or facilities where neutron activation and surface contamination may have already occurred. Consequently, the use of GRS as a geophysical tool for the archaeological investigation of abandoned or decommissioned nuclear facilities is proposed, demonstrated, and discussed using a case study from the Nevada Test Site Nuclear Rocket Development Station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗