Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE↗

On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.

47 OTHER INSTRUMENTATION↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Advanced Materials and Manufacturing Technologies Nondestructive Examination Efforts at Idaho National Laboratory: Report of FY-24 Efforts

This report details FY-24 nondestructive examination (NDE) efforts at Idaho National Laboratory (INL) in support of the Advanced Materials and Manufacturing Technologies (AMMT) program. While the goal of this endeavor is to develop a multi-modal, multi-length scale workflow for nondestructive characterization of advanced manufactured (AM) nuclear reactor components, substantial development remains until this is a reality. In support of this effort X-ray computed tomography (XCT), X-ray diffraction (XRD), neutron computed tomography (nCT), neutron diffraction, lock-in thermography (LIT), multi-point lock-in thermography (MLIT), and positron annihilation spectroscopy (PAS) were all used on AM specimens to examine defects such as voids, porosity, and residual stress. In addition to summarizing the results of these NDE applications, recommendations for integrating these into a more comprehensive undertaking to promote NDE of engineering-scale components are also included.

36 MATERIALS SCIENCE↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

Correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition using neutron diffraction and imaging techniques

In a directed energy deposition (DED) process, the energy density deposited into the materials drives the structure and properties. The energy density is influenced by several printing parameters, such as laser power, hatch spacing, scanning speed, etc. In this study, 316L stainless steels samples were fabricated with varying hatch spacing aiming to induce variations in sample microstructure and properties. A combination of techniques including engineering neutron diffraction, neutron computed tomography, and tensile testing, were employed to correlate the structure and macroscopic properties. Porosity was predominantly observed at the bottom of the deposited materials and was effectively reduced by decreased hatch spacing. Correlatively, compressive residual stress was observed at the bottom of the specimens, while internal stress is largely determined by the hatch spacing. The residual stress in general decreases as the hatch spacing decreases. The maximum ultimate tensile strength (UTS) was found to increase from 517.4 to 528.6 MPa with a strain increased from 0.847 to 0.897 as the hatch spacing decreased from 0.45 to 0.42 mm. However, further increase in energy density by reducing the hatch spacing resulted in a significant decrease in UTS (as low as 452 MPa). This work provides new insights from bulk non-destructive techniques into correlating energy density induced residual stress, porosity, and mechanical property variations in directed energy deposition.

316L stainless steel↗

Simultaneous neutron and X-ray tomography for visualization of graphite electrode degradation in fast-charged lithium-ion batteries

Advanced battery characterization using neutron and X-ray-based imaging modalities is crucial to reveal fundamental degradation modes of lithium-ion batteries (LIBs). Taking advantage of the sensitivity of neutrons to some low-Z (Li) and X-rays to high-Z materials (Cu), here we demonstrate the viability of simultaneous neutron and X-ray tomography (NeXT) as a non-destructive imaging platform for ex-situ 3D visualization of graphite electrode degradation following extreme fast charging (XFC). In addition, we underscore the benefits of the simultaneous of NeXT by combining the neutron and X-ray tomography data from the same sample location for material identification and segmentation of one pristine and two XFC-cycled graphite electrodes (9C charge for 450 cycles). Our ex-situ results and methodology development pave the way for the design of NeXT-friendly LIB geometries that will allow operando and/or in-situ 3D visualization of electrode degradation during XFC.

25 ENERGY STORAGE↗

4D imaging of lithium-batteries using correlative neutron and X-ray tomography with a virtual unrolling technique

The temporally and spatially resolved tracking of lithium intercalation and electrode degradation processes are crucial for detecting and understanding performance losses during the operation of lithium-batteries. Here, high-throughput X-ray computed tomography has enabled the identification of mechanical degradation processes in a commercial Li/MnO 2 primary battery and the indirect tracking of lithium diffusion; furthermore, complementary neutron computed tomography has identified the direct lithium diffusion process and the electrode wetting by the electrolyte. Virtual electrode unrolling techniques provide a deeper view inside the electrode layers and are used to detect minor fluctuations which are difficult to observe using conventional three dimensional rendering tools. Moreover, the 'unrolling' provides a platform for correlating multi-modal image data which is expected to find wider application in battery science and engineering to study diverse effects e.g. electrode degradation or lithium diffusion blocking during battery cycling.

25 ENERGY STORAGE↗

Synchrotron micro-computed tomography analysis of neutron-irradiated U-Mo fuel

The three-dimensional (3D) microstructure of neutron-irradiated uranium-10 wt.% molybdenum (U-10Mo) fuel with a burn-up of 9.8 × 10 21 fissions/cm 3 was characterized using a novel, multi-modal synchrotron micro-computed tomography approach combining propagation-based phase-contrast enhanced and absorption contrast techniques. The porosity development, porosity interconnectedness, swelling, composition, local thickness of the zirconium (Zr) diffusion barrier, and the influence of the fuel–cladding interaction on the local composition and pore morphology, were uniquely determined in 3D. Two cuboids were produced using a focused ion beam-scanning electron microscope at the Zr diffusion barrier–fuel interface and in the bulk fuel. The bulk fuel sample swelled by 53.3 [+9.7/−3.1]%, while the fuel near the Zr–fuel interface swelled by 63.3 [+14.7/−7.2]%. The average local thickness of the Zr diffusion barrier decreased by 53 %, compared to the expected pre-irradiated thickness. Four pore morphology regions were identified initiating parallel to the fuel–Zr interaction region: (1) an interaction layer of suppressed porosity, (2) a layer of elongated and interconnected porosity, (3) a transition zone of low porosity, and (4) a layer of unoriented porosity representative of the bulk fuel behavior. The increase in porosity near the diffusion barrier corresponded to a higher U concentration compared to that in the bulk fuel. The interconnected porosity in the fuel near the diffusion barrier was extensive and oriented parallel to the diffusion barrier, while the bulk fuel had more compact and isolated pore networks. The interaction layer, despite having suppressed porosity, was nearly 100 wt.% U. Porosity suppression at the diffusion barrier corresponds to the expected reduction in radiation-driven diffusion of Xe at the interface despite the anticipated increase in fission product nucleation originating from a higher U concentration. In conclusion, the novel 3D insights of the porosity, swelling, and compositional variations characterized herein can improve the fidelity of fuel performance codes for proliferation-resistant fuels for research and test reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography

Diffusion models have emerged as powerful priors for solving inverse problems in computed tomography (CT). In certain applications, such as neutron CT, it can be expensive to collect large amounts of measurements even for a single scan leading to sparse data sets from which it is challenging to obtain high quality reconstructions even with diffusion models. One strategy to mitigate this challenge is to leverage a complementary, easily available imaging modality; however, such approaches typically require retraining the diffusion model with large datasets. In this work, we propose incorporating an additional modality without retraining the diffusion prior, enabling accelerated imaging of costly modalities. We further examine the impact of imperfect side modalities on cross-modal guidance. Our method is evaluated on sparse-view neutron computed tomography, where reconstruction quality is substantially improved by incorporating X-ray computed tomography of the same samples.

Efimov, Timofey [ORNL] (ORCID:000900090098471X)↗

Three-dimensional neutron far-field tomography of a bulk skyrmion lattice

Abstract Magnetic skyrmions are localized non-collinear spin textures, characterized by an integer topological charge. Commonly observed in thin systems as two-dimensional sheets, in three dimensions skyrmions form tubes that are thought to nucleate and annihilate along their depth on points of vanishing magnetization. However, a lack of techniques that can probe the bulk of the material has made it difficult to perform experimental visualizations of skyrmion lattices and their stabilization through defects. Here we present three-dimensional visualizations of a bulk Co 8 Zn 8 Mn 4 skyrmion lattice through a tomographic algorithm applied to multiprojection small-angle neutron scattering measurements. Reconstructions of the sample show a disordered skyrmion lattice exhibiting three-dimensional topological transitions through emergent (anti)monopole branching and segmentation defect pathways. Our technique provides insights into skyrmion stabilization and topological transition pathways in a bulk skyrmion lattice, guiding the future development and manipulation of skyrmion materials for spintronic applications.

Physics↗

TomoPyUI : a user-friendly tool for rapid tomography alignment and reconstruction

The management and processing of synchrotron and neutron computed tomography data can be a complex, labor-intensive and unstructured process. Users devote substantial time to both manually processing their data ( i.e. organizing data/metadata, applying image filters etc. ) and waiting for the computation of iterative alignment and reconstruction algorithms to finish. In this work, we present a solution to these problems: TomoPyUI , a user interface for the well known tomography data processing package TomoPy . This highly visual Python software package guides the user through the tomography processing pipeline from data import, preprocessing, alignment and finally to 3D volume reconstruction. The TomoPyUI systematic intermediate data and metadata storage system improves organization, and the inspection and manipulation tools (built within the application) help to avoid interrupted workflows. Notably, TomoPyUI operates entirely within a Jupyter environment. Herein, we provide a summary of these key features of TomoPyUI , along with an overview of the tomography processing pipeline, a discussion of the landscape of existing tomography processing software and the purpose of TomoPyUI , and a demonstration of its capabilities for real tomography data collected at SSRL beamline 6-2c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscale spatiotemporal patterns of water, soil organic carbon, and enzymes in plant litter detritusphere

Understanding biophysical and biochemical processes in detritusphere is critical to quantifying and modeling plant residue decomposition dynamics and subsequent soil organic carbon (C) accrual. The objectives of the study were to explore (i) micro-environmental conditions within the detritusphere formed around decomposing corn and soybean leaves, and (ii) the relationships between moisture distribution, enzyme activity, and C dynamics during decomposition. We assessed spatial and temporal dynamics of moisture distribution using X-ray and neutron computed tomography, and activities of β-glucosidase and chitinase, two enzymes involved in soil C and N processing, using zymography. We used 13 C labeled residue to track residue contribution to atmospheric CO 2 and soil organic C. Moisture redistribution pattern varied depending on the residue type. While the water was immediately absorbed by the corn leaves and maintained afterward, switchgrass leaves absorbed water more slowly and created water-deficient zones within ~1mm from the residue. This initial moisture depletion led to lower chitinase activity and residue-derived CO 2 emissions in switchgrass. In contrast to chitinase, β-glucosidase activity was influenced by a combination of vegetation history and residue type, and it was higher when the origin of the residue matched the vegetation history of the soil. Pore size had an opposite impact on the studied enzymes, supporting the notion that contrasting soil pore architecture can stimulate activities of different enzymes through a selection of dominant enzyme producers. We concluded that the decomposition dynamics of plant residues is not only a simple function of residue chemistry, but rather a combined effect of the vegetation history, in part through its effect on microbial community composition, the plant residue chemical and likely physical characteristics, and the soil pore structure in the detritusphere. Together, they create temporally dynamic micro-environmental conditions influencing decomposition. Specifically, our study demonstrated that the initial micro-environment formulated in detritusphere can play an important role in enzyme activities and consequent C dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Atom probe tomography characterization of ion and neutron irradiated Alloy 800H

Alloy 800H is a high temperature and creep resistant alloy, and is considered as a candidate alloy for use in Generation IV nuclear reactor systems. To clarify the alloy's behavior under irradiation, samples were subjected to single ion irradiations up to 20 dpa at 440°C, a dual ion/He irradiation to 17 dpa at 460°C, and a neutron irradiation to 17 dpa at 385°C. The irradiated microstructures were characterized using atom probe tomography to complement previously published transmission electron microscopy studies. Additionally, after single ion irradiation, sparse fine Al and Ti clusters were observed after 1dpa, while high number densities of nanoscale Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops developed after 10 and 20 dpa. The microstructure formed during single ion irradiation exhibited a strong depth dependence. No significant differences were observed between the single and dual ion irradiations. While Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops were also observed after neutron irradiation, the neutron-irradiated microstructure differed from those found in the ion-irradiated samples.

36 MATERIALS SCIENCE↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE (FY23 Version, Rev. 1)

This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nondestructive neutron imaging diagnosis of acidic gas reduction catalyst after 400-Hour operation in natural gas furnace

Residential natural gas furnaces are the primary space-heating devices in US homes, leading to substantial environmental impact caused by the acidic components in the furnace combustion gases. Here, to experimentally demonstrate acidic gas reduction in a furnace, a monolithic catalyst was fabricated and was called the AGR. A commercially-available condensing furnace was retrofitted with the AGR, and a 400-hour reliability and durability test was conducted. The results showed that the AGR significantly reduced acidic gases in the flue gas and produced condensate with neutral pH. Challenges were also revealed: inappropriate condensate drainage caused incomplete combustion and amorphous carbon deposits. To nondestructively survey the internal state of the AGR, neutron computed tomography (NCT) was employed to produce spatially resolved 2D and 3D representations of the 2-L, aged AGR component. The NCT results confirm the integrity of the AGR component, which consists of two blocks, without deformation or damage to AGR channels. The distribution of the particle accumulation in the middle of the top block was visibly heavier than the entrance and exit of the top block. The representative cross-section views revealed significant aggregation in the central region but not at the rim. The spatially resolved details provide in-depth diagnosis, evaluation, and understanding of the AGR. The insights can enable new AGR designs that realize a uniform and self-cleaning flow pattern, alleviate significant particle aggregation, and thus enhance AGR-enabled furnace performance. The neutron imaging method demonstrates the good potential that can diagnose faults and improve the design, optimization, and production processes of novel catalysts and other components or systems with heavy metal shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗