Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nitrogen saturation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

Liquid Transfer Cryogenic Test Facility: Initial hydrogen and nitrogen no-vent fill data

The Liquid Transfer Cryogenic Test Facility is a versatile testbed for ground-based cryogenic fluid storage, handling, and transfer experimentation. The test rig contains two well instrumented tanks, and a third interchangeable tank, designed to accommodate liquid nitrogen or liquid hydrogen testing. The internal tank volumes are approx. 18, 5, and 1.2 cu. ft. Tank pressures can be varied from 2 to 30 psia. Preliminary no vent fill tests with nitrogen and hydrogen were successfully completed with the test rig. Initial results indicate that no vent fills of nitrogen above 90 percent full are achievable using this test configuration, in a 1-g environment, and with inlet liquid temperatures as high as 143 R, and an average tank wall temperature of nearly 300 R. This inlet temperature corresponds to a saturation pressure of 19 psia for nitrogen. Hydrogen proved considerably more difficult to transfer between tanks without venting. The highest temperature conditions resulting in a fill level greater than 90 percent were with an inlet liquid temperature of 34 R, and an estimated tank wall temperature of slightly more than 100 R. Saturation pressure for hydrogen at this inlet temperature is 10 psia. All preliminary no vent fill tests were performed with a top mounted full cone nozzle for liquid injection. The nozzle produces a 120 degree conical droplet spray at a differential pressure of 10 psi. Pressure in the receiving tank was held to less than 30 psia for all tests.

Moran, Matthew E.↗

Density measurement in air with a saturable absorbing seed gas

Resonantly enhanced scattering from the iodine molecule is studied experimentally for the purpose of developing a scheme for the measurement of density in a gas dynamic flow. A study of the spectrum of iodine, the collection of saturation data in iodine, and the development of a mathematical model for correlating saturation effects were pursued for a mixture of 0.3 torr iodine in nitrogen and for mixture pressures up to one atmosphere. For the desired pressure range, saturation effects in iodine were found to be too small to be useful in allowing density measurements to be made. The effects of quenching can be reduced by detuning the exciting laser wavelength from the absorption line center of the iodine line used (resonant Raman scattering). The signal was found to be nearly independent of pressure, for pressures up to one atmosphere, when the excitation beam was detuned 6 GHz from line center for an isolated line in iodine. The signal amplitude was found to be nearly equal to the amplitude for fluorescence at atmospheric pressure, which indicates a density measurement scheme is possible.

Baganoff, D.↗

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity↗

Pool film boiling from rotating and stationary spheres in liquid nitrogen

Results are presented for a preliminary experiment involving a saturated pool boiling at 1 atm from rotating 2 and 3 inch diameter spheres which were immersed in LN2. Additional results are presented for a stationary 2 inch diameter sphere quenched in LN2, which were obtained with a more versatile and complete experimental apparatus. The speed of the rotational tests varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere.

Cuan, Winston M.↗

Laboratory studies of irradiated nitrogen-methane mixtures - Applications to Triton

The characteristics of the near-IR spectrum of Triton is addressed in view of 0.8-2.5 micron laboratory transmission spectra obtained for methane dissolved in liquid nitrogen. It is found that, for methane concentrations greater than 3 percent of the saturation value, the collision-induced, 2.152-micron first-overtone band of molecular nitrogen is overshadowed by the methane band centered at 2.3 microns. While gamma-radiolysis of nitrogen-methane mixtures generates an unstable precipitate whose yellowish color is qualitatively similar to the yellow color of Triton, no specific absorption band in the precipitate can be unambiguously identified on Triton.

Piscitelli, J. R.↗

Active synthetic soil

A synthetic soil/fertilizer for horticultural application having all the agronutrients essential for plant growth is disclosed. The soil comprises a synthetic apatite fertilizer having sulfur, magnesium, and micronutrients dispersed in a calcium phosphate matrix, a zeolite cation exchange medium saturated with a charge of potassium and nitrogen cations, and an optional pH buffer. Moisture dissolves the apatite and mobilizes the nutrient elements from the apatite matrix and the zeolite charge sites.

Ming, Douglas W.↗

Active synthetic soil

A synthetic soil/fertilizer for horticultural application having all the agronutrients essential for plant growth is disclosed. The soil comprises a synthetic apatite fertilizer having sulfur, magnesium and micronutrients dispersed in a calcium phosphate matrix, a zeolite cation exchange medium saturated with a charge of potassium and nitrogen cations, and an optional pH buffer. Moisture dissolves the apatite and mobilizes the nutrient elements from the apatite matrix and the zeolite charge sites.

Ming, Douglas W.↗

In-Line Capacitance Sensor for Real-Time Water Absorption Measurements

A capacitance/dielectric sensor was designed, constructed, and used to measure in real time the in-situ water concentration in a desiccant water bed. Measurements were carried out with two experimental setups: (1) passing nitrogen through a humidity generator and allowing the gas stream to become saturated at a measured temperature and pressure, and (2) injecting water via a syringe pump into a nitrogen stream. Both water vapor generating devices were attached to a downstream vertically-mounted water capture bed filled with 19.5 g of Moisture Gone desiccant. The sensor consisted of two electrodes: (1) a 1/8" dia stainless steel rod placed in the middle of the bed and (2) the outer shell of the stainless steel bed concentric with the rod. All phases of the water capture process (background, heating, absorption, desorption, and cooling) were monitored with capacitance. The measured capacitance was found to vary linearly with the water content in the bed at frequencies above 100 kHz indicating dipolar motion dominated the signal; below this frequency, ionic motion caused nonlinearities in the water concentration/capacitance relationship. The desiccant exhibited a dielectric relaxation whose activation energy was lowered upon addition of water indicating either a less hindered rotational motion or crystal reorientation.

Nurge, Mark A.↗

Depressurization and two-phase flow of water containing high levels of dissolved nitrogen gas

Depressurization of water containing various concentrations of dissolved nitrogen gas was studied. In a nonflow depressurization experiment, water with very high nitrogen content was depressurized at rates from 0.09 to 0.50 MPa per second and a metastable behavior which was a strong function of the depressurization rate was observed. Flow experiments were performed in an axisymmetric, converging diverging nozzle, a two dimensional, converging nozzle with glass sidewalls, and a sharp edge orifice. The converging diverging nozzle exhibited choked flow behavior even at nitrogen concentration levels as low as 4 percent of the saturation level. The flow rates were independent of concentration level. Flow in the two dimensional, converging, visual nozzle appeared to have a sufficient pressure drop at the throat to cause nitrogen to come out of solution, but choking occurred further downstream. The orifice flow motion pictures showed considerable oscillation downstream of the orifice and parallel to the flow. Nitrogen bubbles appeared in the flow at back pressures as high as 3.28 MPa, and the level at which bubbles were no longer visible was a function of nitrogen concentration.

Simoneau, R. J.↗

Helium Saturation of Liquid Propellants

The research is in three areas which are: (1) techniques were devised for achieving the required levels of helium (He) saturation in liquid propellants (limited to monomethylhydrazine (MMH) and nitrogen tetroxide (NTO)); (2) the values were evaluated for equilibrium solubilities of He in liquid propellants as currently used in the industry; and (3) the He dissolved in liquid propellants were accurately measured. Conclusions drawn from these studies include: (1) Techniques for dissolving He in liquid propellants depending upon the capabilities of the testing facility (Verification of the quantity of gas dissolved is essential); (2) Until greater accuracy is obtained, the equilibrium solubility values of He in MMH and NTO as cited in the Air Force Propellant Handbooks should be accepted as standard (There are still enough uncertainties in the He saturation values to warrant further basic experimental studies); and (3) The manometric measurement of gas volume from a frozen sample of propellant should be the accepted method for gas analysis.

Yavrouian, A. H.↗

Real gas effects 2: Influence of condensation on minimum operating temperatures of cryogenic wind tunnels

Condensation effects are responsible for the minimum operating temperatures of cryogenic wind tunnels at total pressures up to about 9 atmospheres. The two primary modes of condensation homogeneous nucleation and heterogeneous nucleation and the conditions with which either may limit minimum operating temperatures are reveiwed. Previous hypersonic and supersonic condensation data are reviewed as are data taken in the nitrogen gas, Langley 0.3 Meter Transonic Cryogenic Tunnel. Analysis of data in the 0.3 m tunnel suggests that the onset of homogenous nucleation may be approximated by an analysis by sivier and that the onset of heterogeneous nucleation is only apparent just below free stream saturation. Extension of the results from the 0.3 m tunnel to other nitrogen gas cryogenic tunnels is discussed and is shown to depend on length scales, purity of the liquid nitrogen injected for cooling, number of particulates in the flow, and the extent to which the injected liquid nitrogen is evaporated.

Hall, R. M.↗

New Technique for Cryogenically Cooling Small Test Articles

Convective heat removal techniques to rapidly cool small test articles to Earth-Moon L2 temperatures of 77 K were accomplished through the use of liquid nitrogen (LN2). By maintaining a selected pressure range on the saturation curve, test articles were cooled below the LN2 boiling point at ambient pressure in less than 30 min. Difficulties in achieving test pressures while maintaining the temperature tolerance necessitated a modification to the original system to include a closed loop conductive cold plate and cryogenic shroud

Rodriquez, Karen M.↗

Europa Propulsion Valve Seat Material Testing

The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

Addona, Brad M.↗

A few ways of calculating the similarity parameter kappa* for real gases

In connection with the question on the applicability of test results obtained from cryogenic wind tunnels to the large-scale model the similarity parameter is referred to. A simple method is given for calculating the similarity parameter. From the numerical values obtained it can be deduced that nitrogen behaves practically like an ideal gas when it is close to the saturation point and in a pressure range up to 4 bar. The influence of this parameter on the pressure distribution of a supercritical profile confirms this finding.

Lorenz-Meyer, W.↗

Nitrous oxide measurements in the eastern tropical Pacific Ocean

The paper considers nitrous oxide measurements in the eastern tropical Pacific Ocean. The concentration of N2O in the marine air showed a direct relationship to the N2O in the surface sea water, with the highest N2O mixing ratios over highly supersaturated regions; water samples were also collected down to depths of 300 m at seven hydrocast stations. The stations showed two distribution patterns for N2O concentration vs depth for the region between the surface and 300 m; two stations in the oxygen deficient region off the coast of Peru showed considerable N2O super-saturation at all depths, and results indicate that the role of N2O in the nitrogen cycle of the ocean may be more complex than previously suggested.

Pierotti, D.↗

Improved materials characterization for spacecraft applications

A material outgassing test consists of an effusion cell, mass spectrometer, and thermally controlled quartz crystal microbalance (TQCM). The material sample is placed in the effusion cell at a predetermined temperature, and the sample is outgassed in a vacuum of 0.000001 torr range. The total outgassing mass as a function of time is determined with the TQCM which is cooled to LN2 temperatures. Based on the view factor of the TQCM, the total outgassed mass can be determined. The technique can be verified by comparing the results to the actual mass loss of the sample which is determined by hanging the diffusion cell from the Cohn microbalance. The mass spectrometer can be used to determine if there are any low molecular weight components outgassing, such a nitrogen which does not condense on the TQCM. After the material outgasses to a point of saturation, the effusion cell is closed off, and the TQCM is slowly heated to allow the condensed film to be broken down into its components. As the temperature is increased, the components evaporate from the surface at a different rate and can be detected with the mass spectrometer. The relative amount of each component is found by the change in frequency of the TQCM as the component evaporates. Hence, from this test, not only is isothermal kinetic data obtained, but the primary components can also be identified in terms of their molecular weight.

Cull, R.↗