Viking orbiter 1975 articulation control actuators
The articulation subsystem actuators were rigorously tested in severe environments. They were operated through temperature ranges from -73 C to +121 C. In each case the temperature rate of change was at maximum. The actuator under test at room temperature was put into a pre-chilled or preheated chamber. Satisfactory performance was obtained throughout this full temperature range and under the temperature shock conditions above. However, at temperatures below -78 C some leakage was experienced through the O-ring seal around the shaft. The actuators were subjected to severe vibration and 500 g shock test with a time duration of 0.0007 seconds. The scan actuator was life tested by operating it from stop to stop through 2,000 cycles with 20,000 start-stop procedures randomly distributed through the 2,000 cycles.