Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Illinois Express Quantum Network (IEQNET): metropolitan-scale experimental quantum networking over deployed optical fiber

The Illinois Express Quantum Network (IEQNET) is a program to realize metro-scale quantum networking over deployed optical fiber using currently available technology. IEQNET consists of multiple sites that are geographically dispersed in the Chicago metropolitan area. Each site has one or more quantum nodes (Qnodes) representing the communication parties in a quantum network. Q-nodes generate or measure quantum signals such as entangled photons and communicate the results via standard, classical, means. The entangled photons in IEQNET nodes are generated at multiple wavelengths, and are selectively distributed to the desired users via optical switches. Here we describe the network architecture of IEQNET, including the Internet-inspired layered hierarchy that leverages software-defined-networking (SDN) technology to perform traditional wavelength routing and assignment between the Q-nodes. Specifically, SDN decouples the control and data planes, with the control plane being entirely classical. Issues associated with synchronization, calibration, network monitoring, and scheduling will be discussed. An important goal of IEQNET is demonstrating the extent to which the control plane can coexist with the data plane using the same fiber lines. This goal is furthered by the use of tunable narrow-band optical filtering at the receivers and, at least in some cases, a wide wavelength separation between the quantum and classical channels. We envision IEQNET to aid in developing robust and practical quantum networks by demonstrating metro-scale quantum communication tasks such as entanglement distribution and quantum-state teleportation.

Chung, Joaquin↗

Retina-inspired narrowband perovskite sensor array for panchromatic imaging

The retina is the essential part of the human visual system that receives light, converts it to neural signal, and transmits to brain for visual recognition. The red, green, and blue (R/G/B) cone retina cells are natural narrowband photodetectors (PDs) sensitive to R/G/B lights. Connecting with these cone cells, a multilayer neuro-network in the retina provides neuromorphic preprocessing before transmitting to brain. Inspired by this sophistication, we develop the narrowband (NB) imaging sensor combining R/G/B perovskite NB sensor array (mimicking the R/G/B photoreceptors) with a neuromorphic algorithm (mimicking the intermediate neural network) for high-fidelity panchromatic imaging. Compared to commercial sensors, we use perovskite “intrinsic” NB PD to exempt the complex optical filter array. In addition, we use an asymmetric device configuration to collect photocurrent without external bias, enabling a power-free photodetection feature. These results display a promising design for efficient and intelligent panchromatic imaging.

42 ENGINEERING↗

CMOS-fabricated ultraviolet light modulator using low-loss alumina piezo-optomechanical photonics

Ultra-violet (UV) and near-UV wavelengths are necessary for many important optical transitions for quantum technologies and various sensing mechanisms for biological and chemical detection. However, all well-known photonic platforms have excessively high losses in the UV, which has prevented photonic integrated circuits (PICs) being used to address these and other important application spaces. Photonic waveguides using low-loss alumina cores and silicon dioxide cladding have emerged as a promising solution because of alumina’s large optical bandgap and the high quality of films enabled by atomic layer deposition. These properties allow passive, low-loss waveguide operation down to at least 266 nm using multimode widths. However, to the best of our knowledge, active alumina PICs have only been realized using thermo-optic tuning, which precludes switching speeds shorter than approximately 100 microseconds, high circuit densities, and cryogenically compatible operation. Here, we introduce a CMOS-fabricated, piezo-optomechanical PIC platform using alumina waveguides and piezoelectric aluminum nitride strain actuators. The platform allows for sub-microsecond switching times, high circuit densities, and cryogenic operation which is desired in many UV PIC applications. We demonstrate a high-performance, reconfigurable optical filter operating at wavelengths as low as 320 nm. The filter has a 6-nanosecond switching time, a loaded linewidth of 3.3 GHz, tuning rate of 28 V/linewidth, and a hold power of less than 20 nW at one linewidth detuning. This work establishes the foundations for a new class of CMOS-fabricated, rapidly reconfigurable, and low-power UV photonic circuits compatible with wavelengths as low as 225 nm.

Castillo, Zachary A. [Sandia National Laboratories↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CRADA Number NFE-19-07847 with MantaPoole Technologies (CRADA Final Report)

As the world becomes more automated, smart and autonomous systems that utilize advanced 3D machine vision are becoming ever more prevalent. To function autonomously, these smart machines need to be able to identify the “what” and “where” of their application by capturing color and depth information. The color information provides the needed contrast information to identify the “what” of a scene while the depth information allows the smart machine to identify “where” an object in a 3D environment is. To capture both the color and depth information using only a single sensor, MantaPoole Technologies (MPT) is developing a new type of 3D light field camera. The approach leverages MPT’s active micro-optics technology which when aligned and placed over an imaging detector are designed to act as an advanced optical filter that controls the direction of light that reaches the underlying pixels.

47 OTHER INSTRUMENTATION↗

System and method for remote detection and location of gas leaks

A system for monitoring for a gas leak from a gas containing structure is disclosed. The system includes a lens that directs an image of a scene of interest through an optical filter onto a detector. The filter is associated with the lens and the filter has one or more passbands that passes wavelengths which match one or more emission or reflectively wavelengths of the gas being monitored. A detector receives the image after the image passes through the lens and the filter. The detector generates image data representing the scene including the gas containing structure. A processor is configured to process the image data by executing machine executable code stored on a memory. The machine executable code processes the image data to identify turbulence flows in the image data such that turbulence flow indicates a gas leak, and generate and send an alert in response to the identification of a turbulence flow.

O'Neill, Mary D.↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

TAP Absorption Coefficients

The data set of aerosol light absorption coefficients were collected by two tricolor absorption photometers (TAP; Brechtel Model 2901) in July and August, 2022 during the TRACER field campaign at the AMF1 site in La Porte, Texas. One of the TAPs at the La Porte site was an RGB model measuring aerosol light absorption at 652, 528, 467 nm, and the other was an UV model measuring absorption at the same red and green wavelengths but at an additional UV wavelength at 365 nm. Since TAP is a filter-based optical instrument using 47-mm glass fiber filters, the output absorption coefficients are corrected for filter loading and scattering effects based on a correction scheme developed in "Comment on ‘Calibration and Intercomparison of Filter-Based Measurements of Visible Light Absorption by Aerosols’" by John A. Ogren 2010. This uploaded dataset contains both the Ogren corrected absorption coefficients (column header with “ Ogren”) and the raw absorption coefficients without the correction scheme (column header with “_ Raw”). During the field campaign, the two TAPs operated side by side with a shared inlet at a flow rate of 2 lpm. In July, no inlet impactors/cyclones were installed; however, beginning in August, a PM2.5 cyclone inlet was installed.

54 ENVIRONMENTAL SCIENCES↗

Details of the neutral energy distribution and ionization source using spectrally resolved Balmer-alpha measurements on DIII-D

Spectrally resolved passive Balmer- α (D- α, H- α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals (“thermal” neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, in this study, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescence based fiber optic probe for the detection of rare earth elements

The disclosure relates to an apparatus, method and process for detecting rare earth elements. The system includes an LED powered by a first power source and a focusing lens in optical communication with the LED. A shortpass filter is in optical communication with the focusing lens; and a fiber bifurcated cable in optical communication with the shortpass filter. The system includes a probe tip in optical communication with the fiber bifurcated cable and a sample; a first aspheric lens in optical communication with the fiber bifurcated cable. A longpass filter is in optical communication with the first aspheric lens and a second aspheric lens in optical communication with the longpass filter. The system includes a spectrometer connected to a power source, where the spectrometer is in optical communication with the second aspheric lens.

Ahern, John C.↗

Photonic ring resonator notch filters for astronomical OH line suppression

Photonic ring resonator arrays used as notch filters are a promising novel solution to improve the signal-to-noise ratio of ground-based astronomical observations by suppressing OH emission lines in the near-infrared (NIR) wavelength range (0.9-2.5 μm). We aim to fabricate a series of ring resonators connected by a waveguide, each with its resonance wavelength and full-width-half-maximum (FWHM) matched with one of the OH emission lines. The fundamental structure of ring resonator-based notch filters is a ring resonator evanescently coupled to a waveguide. Due to the optical loss of the ring resonator, the transmission of light through the waveguide will be suppressed at the resonance wavelength of the ring resonator. The degree of suppression can be controlled by varying the coupling strength between the waveguide and the ring resonator, while the resonance wavelength can be controlled by the geometry and size of the ring. However, since a single ring resonator has multiple modes each with a different wavelength separated by its free spectral range (FSR), the additional suppression at other wavelengths may undermine the signal. Therefore, the ideal FSR off the ring resonators needs to be larger than the measurement window. For this application, we aim the FSR to be 1 larger than 30 nm . Our initial measurement results revealed two major challenges for this application. First, the FSR of the ring resonators is limited by the bending loss of ring resonators. In a standard 220 nm silicon-on-insulator material platform, the FSR of ring resonators cannot exceed 30 nm; Second, due to the wafer thickness variation and fabrication inaccuracy, the achievable accuracy in the resonance wavelength of a fabricated single ring resonator is only ~1.5 nm. In this work, we report our novel solutions to the above two challenges. For the first one, we have developed a novel structure based on the Vernier effect to greatly raise the FSR of ring resonators. Serially coupled Vernier ring structures is a typical approach to increase the FSR without encountering bending loss, but it requires restrictive matching of the coupling and optical loss of the rings and any imperfect matching can result in even noisier signals. On the contrary, our structure, as shown in shown in Fig. 1, does not require the restrictive matching. The signals of two output ports in our structure marked in Fig. 1 will be added together to form the final output signal, and Fig. 2 shows the finite-difference time-domain (FDTD) simulation results of the final output signal. As can be seen, the FSR of the entire structure is well-beyond 60 nm with little noise at other wavelengths. For the second one, we have developed an easy-to-implement method to permanently tune the resonance wavelengths of ring resonators within 0.1 nm accuracy. The tuning mechanism is based on the property of hydrogen silsesquioxane (HSQ) resist. As a negative tone electron beam resist, HSQ upon exposure will cross-link and eventually form SiO2. The refractive 2 index of HSQ resist and formed SiO2 are slightly different , enabling the tuning. By having a thin layer of HSQ resist on top of ring resonator structures followed by SiO2 cladding, the resonance wavelengths of ring resonators can be post-tuned Advances in Optical Astronomical Instrumentation 2019, edited by Simon Ellis, Céline d'Orgeville, Downloaded From: https://www.spiedigitallibrary.org/conference-proceedings-of-spie on 23 Sep 2020 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use through electron beam exposure. We have found that, within 5 nm tuning range, the resonance wavelength shift and dosage applied obeys a linear relationship. So a simple calibration beforehand can result in resonance wavelength tuning within 0.1 nm accuracy. The transmission spectra of a 3-ring device before and after tuning is shown in Fig. 3.

Astronomical optics↗

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN↗

Atom femtosecond optical trap based on spectrally filtered laser radiation

We have examined the use of alkali metal (rubidium) vapour for spectral filtering of broadband pulsed laser light that is used to produce a femtosecond pulsed optical dipole trap. It has been shown that, even at large detuning of the centre emission frequency from the frequency of atomic transitions, spectral components present in the wings of the laser emission line are capable of heating localised atoms, thus reducing their lifetime in the atomic trap. Using atomic vapour for filtering the laser emission spectrum, we have suppressed its spectral components resulting in heating. This has made it possible to increase the lifetime of atoms in the pulsed optical dipole trap to a value comparable to their lifetime in an optical trap formed by narrow-band cw laser light. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applying Information Theory to Design Optimal Filters for Photometric Redshifts

In this paper we apply ideas from information theory to create a method for the design of optimal filters for photometric redshift estimation. We show the method applied to a series of simple example filters in order to motivate an intuition for how photometric redshift estimators respond to the properties of photometric passbands. We then design a realistic set of six filters covering optical wavelengths that optimize photometric redshifts for z <= 2.3 and i < 25.3. We create a simulated catalog for these optimal filters and use our filters with a photometric redshift estimation code to show that we can improve the standard deviation of the photometric redshift error by 7.1% overall and improve outliers 9.9% over the standard filters proposed for the Large Synoptic Survey Telescope (LSST). We compare features of our optimal filters to the LSST and find that the LSST filters incorporate key features for optimal photometric redshift estimation. Finally, we describe how information theory can be applied to a range of optimization problems in astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-dimensional image edge enhancement using two orders of Bragg diffraction

The process of two-dimensional image edge enhancement with an acousto-optical spatial filter using two orders of light diffraction is studied. It is theoretically shown that the diffraction that occurs in a paratellurite crystal on a ‘slow’ acoustic wave propagating orthogonally to the optical axis of the crystal allows enhancing a two-dimensional edge of an image, transferred by optical radiation with a wavelength of 0.63 μm in a wide band of acoustic frequencies 25 – 50 MHz. Enhancement of a two-dimensional image edge at an acoustic frequency of 29 MHz is experimentally demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗