Search NASA⌕ Search

SEARCH · Search NASA

Results for “OSB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Materials Data on Th(BOs)2 by Materials Project

Th(OsB)2 crystallizes in the orthorhombic Fddd space group. The structure is three-dimensional. Th4+ is bonded in a 4-coordinate geometry to four equivalent Os2- atoms. All Th–Os bond lengths are 3.04 Å. Os2- is bonded in a 4-coordinate geometry to two equivalent Th4+ and four equivalent B atoms. There are two shorter (2.10 Å) and two longer (2.18 Å) Os–B bond lengths. B is bonded to four equivalent Os2- atoms to form a mixture of distorted edge and corner-sharing BOs4 trigonal pyramids.

36 MATERIALS SCIENCE↗

Materials Data on U(BOs)4 by Materials Project

U(OsB)4 crystallizes in the tetragonal I4_1/acd space group. The structure is three-dimensional. U6+ is bonded in a 12-coordinate geometry to twelve equivalent Os+1.50- atoms. There are a spread of U–Os bond distances ranging from 2.93–3.27 Å. Os+1.50- is bonded in a 5-coordinate geometry to three equivalent U6+ and five equivalent B atoms. There are a spread of Os–B bond distances ranging from 2.16–2.28 Å. B is bonded in a 6-coordinate geometry to five equivalent Os+1.50- and one B atom. The B–B bond length is 1.77 Å.

36 MATERIALS SCIENCE↗

Materials Data on La2Al(BOs)2 by Materials Project

La2Al(OsB)2 crystallizes in the monoclinic C2/c space group. The structure is three-dimensional. there are two inequivalent La3+ sites. In the first La3+ site, La3+ is bonded in a 6-coordinate geometry to one Os+1.50- and five B3- atoms. The La–Os bond length is 3.20 Å. There are a spread of La–B bond distances ranging from 2.77–3.03 Å. In the second La3+ site, La3+ is bonded in a 4-coordinate geometry to four B3- atoms. There are a spread of La–B bond distances ranging from 2.88–3.11 Å. There are two inequivalent Os+1.50- sites. In the first Os+1.50- site, Os+1.50- is bonded in a 5-coordinate geometry to three equivalent Al3+ and two B3- atoms. There are a spread of Os–Al bond distances ranging from 2.65–2.77 Å. There are one shorter (2.02 Å) and one longer (2.13 Å) Os–B bond lengths. In the second Os+1.50- site, Os+1.50- is bonded in a 4-coordinate geometry to one La3+, one Al3+, and three B3- atoms. The Os–Al bond length is 2.58 Å. There are one shorter (2.01 Å) and two longer (2.13 Å) Os–B bond lengths. Al3+ is bonded in a 4-coordinate geometry to four Os+1.50- atoms. There are two inequivalent B3- sites. In the first B3- site, B3- is bonded to five La3+ and two Os+1.50- atoms to form a mixture of distorted edge and corner-sharing BLa5Os2 pentagonal bipyramids. In the second B3- site, B3- is bonded in a 7-coordinate geometry to four La3+ and three Os+1.50- atoms.

36 MATERIALS SCIENCE↗

Materials Data on Pr(BOs)4 by Materials Project

Pr(OsB)4 crystallizes in the tetragonal P4_2/n space group. The structure is three-dimensional. Pr3+ is bonded in a 8-coordinate geometry to eight equivalent Os+0.75- atoms. There are four shorter (3.22 Å) and four longer (3.23 Å) Pr–Os bond lengths. Os+0.75- is bonded in a 4-coordinate geometry to two equivalent Pr3+ and four equivalent B atoms. There are a spread of Os–B bond distances ranging from 2.14–2.18 Å. B is bonded in a 5-coordinate geometry to four equivalent Os+0.75- and one B atom. The B–B bond length is 1.78 Å.

36 MATERIALS SCIENCE↗

Materials Data on Nd(BOs)2 by Materials Project

Nd(OsB)2 crystallizes in the orthorhombic Fddd space group. The structure is three-dimensional. Nd3+ is bonded in a 4-coordinate geometry to four equivalent Os+1.50- atoms. All Nd–Os bond lengths are 3.05 Å. Os+1.50- is bonded in a 4-coordinate geometry to two equivalent Nd3+ and four equivalent B atoms. There are two shorter (2.10 Å) and two longer (2.18 Å) Os–B bond lengths. B is bonded to four equivalent Os+1.50- atoms to form a mixture of distorted edge and corner-sharing BOs4 trigonal pyramids.

36 MATERIALS SCIENCE↗

Materials Data on Gd(BOs)2 by Materials Project

Gd(OsB)2 crystallizes in the orthorhombic Fddd space group. The structure is three-dimensional. Gd3+ is bonded in a 4-coordinate geometry to four equivalent Os+1.50- atoms. All Gd–Os bond lengths are 3.02 Å. Os+1.50- is bonded in a 4-coordinate geometry to two equivalent Gd3+ and four equivalent B atoms. There are two shorter (2.08 Å) and two longer (2.18 Å) Os–B bond lengths. B is bonded in a 4-coordinate geometry to four equivalent Os+1.50- atoms.

36 MATERIALS SCIENCE↗

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate

A sealed or unvented attic is an energy-efficient envelope component that can reduce the amount of energy a house consumes for space conditioning if the air handler and/or ducts are located in the attic. The attic is typically sealed by using spray foam on the underside of the roof deck and covering the soffit, ridge and gable vents to minimize air leakage from the attic to the outside. This approach can save up to 10% in space-conditioning energy when ducts are located in the attic (DOE 2013). Past research done by ORNL and Florida Solar Energy Center suggests that in more hot, humid climates, an unvented attic could potentially create a more humid, uncomfortable living environment than a vented attic (Colon 2011, Boudreaux, Pallin et al. 2013). Research showed that controlling the higher indoor humidity could reduce the energy savings from the sealed, unvented attic, which in turn would decrease the energy savings payback. Research also showed that the roof assembly (5.5 inches of open-cell foam, 1inch of closed-cell foam, OSB, felt paper, and asphalt shingles) stored moisture, thus acting as a moisture buffer. During the fall and winter, the roof assembly stored moisture and during the spring and summer it released moisture. This phenomenon is not seen in a vented attic, in which the air exchange rate to the outside is greater and, in the winter, helps to dehumidify the attic air. It was also seen that in a vented attic, the direction of water vapor diffusion is on average from the attic to the interior of the house. Air leakage from the attic to the interior also occurs during more of the year in a house with an unvented attic than in one with a vented attic. These discoveries show that the moisture dynamics in a house with an unvented attic are much different from those in a house with a vented attic. This study reports on a series of computer model investigations completed to determine the key variables impacting indoor comfort and the durability of roof assemblies against moisture. The key variables investigated were the leakage area from the attic to the outside, leakage area from the attic to the interior, leakage area from the interior to the outside, supply duct leakage in the attic, and interior moisture generation. These investigations are described in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Columbia County Habitat for Humanity Passive Townhomes

Columbia County (New York) Habitat for Humanity built a pair of townhomes to Passive House criteria with the purpose of exploring approaches for achieving Passive House performance and to eventually develop a prototype design for future projects. The project utilized a 2x6 frame wall with a structural insulated panel curtain wall and a ventilated attic over a sealed OSB ceiling air barrier. Mechanical systems include a single head, wall mounted ductless mini-split heat pump in each unit and a heat recovery ventilator. Costs were $26,000 per unit higher for Passive House construction compared with the same home built to ENERGY STAR version 3 specifications, representing about 18% of total construction cost. This report discusses the cost components, energy modeling results and lessons from construction. Two alternative ventilation systems are analyzed: a central system; and, a point-source system with small through-wall units distributed throughout the house. The report includes a design and cost analysis of these two approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage Rates in Typical Air Barrier Assemblies

Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

Using Wearable Computers in Shuttle Processing: A Feasibility Study

Shuttle processing operations are performed following prescribed instructions compiled in a Work Authorization Document (WAD). Until very recently, WADs were printed so that they could be properly executed, including the buy off of each and every step by the appropriate authorizing agent. However, with the development of EPICs, Maximo, and PeopleSoft applications, some of these documents are now available in electronic format; hence, it is possible for technicians and engineers to access them on line and buy off the steps electronically. To take full advantage of these developments, technicians need access to such documents at the point of job execution. Body wearable computers present an opportunity to develop a WAD delivery system that enables access while preserving technician's mobility, safety levels, and quality of work done. The primary objectives of this project were to determine if body wearable computers are a feasible delivery system for WADs. More specifically, identify and recommend specific brands of body wearable computers readily available on the market. Thus, this effort has field-tested this technology in two areas of shuttle processing, and it has examined the usability of the technology. Results of two field tests and a Human Factors Usability Test are presented. Section 2 provides a description of the body wearable computer technology. Section 3 presents the test at the Space Shuttle Main Engine (SSME) Shop. Section 4 presents the results of the integration test at the Solid Rocket Boosters Assembly and Refurbishing Facility (SRBARF). Section 5 presents the results of the usability test done at the Operations Support Building (OSB).

Centeno, Martha A.↗

Thermal Performance Evaluation of Attic Radiant Barrier Systems Using the Large Scale Climate Simulator (LSCS)

Application of radiant barriers and low-emittance surface coatings in residential building attics can significantly reduce conditioning loads from heat flow through attic floors. The roofing industry has been developing and using various radiant barrier systems and low-emittance surface coatings to increase energy efficiency in buildings; however, minimal data are available that quantifies the effectiveness of these technologies. This study evaluates performance of various attic radiant barrier systems under simulated summer daytime conditions and nighttime or low solar gain daytime winter conditions using the large scale climate simulator (LSCS). The four attic configurations that were evaluated are 1) no radiant barrier (control), 2) perforated low-e foil laminated oriented strand board (OSB) deck, 3) low-e foil stapled on rafters, and 4) liquid applied low-emittance coating on roof deck and rafters. All test attics used nominal RUS 13 h-ft2- F/Btu (RSI 2.29 m2-K/W) fiberglass batt insulation on attic floor. Results indicate that the three systems with radiant barriers had heat flows through the attic floor during summer daytime condition that were 33%, 50%, and 19% lower than the control, respectively.

building energy efficiency↗

New Whole-House Solutions Case Study: Pine Mountain Builders

Pine Mountain Builders achieved HERS scores as low as 59 and electric bills as low as $50/month with extensive air sealing (blower door tests = 1.0 to 1.8 ACH 50), R-3 XPS sheathing instead of OSB, and higher efficiency heat pumps.

air sealing↗

DOE Zero Energy Ready Home Case Study: The Imery Group — Proud Green Home, Serenbe, GA

The first certified Zero Energy Ready Home in Georgia was honored in the Custom Builder category of the 2014 Housing Innovation Awards. The 2,811-ft2, two-story custom home has 2x6 advanced framed walls filled with R-20 of open-cell spray foam, plus an R-6.6 insulated coated OSB sheathing. Also included is electronic monitoring equipment that tracks the PV, solar thermal water heater, ERV, mini-split heat pump with three indoor heads, solar water heater, and LED and CFL lighting.

2014 housing innovation awards↗

DOE Zero Energy Ready Home Case Study: John Hubert Associates — EXIT-0 House, North Cape May, NJ

This house is the first DOE Zero Energy Ready Home for this builder and won a Custom Builder award in the 2014 Housing Innovation Awards. The 1,871-ft2 home features advanced-framed above-grade walls with R-21 fiberglass batt plus an R-3.6-insulated coated OSB sheathing, R-18 rigid-foam-insulated crawlspace walls, solar water heating, a high-efficiency heat pump, an HRV, and mostly LED lighting.

2014 housing innovation awards↗