Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupation number”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating traffic-based building occupancy schedules in Chattanooga, Tennessee from a grid of traffic sensors

Building occupancy significantly impacts energy use, timing for demand impacts, and is a significant source of uncertainty in building energy models. There are relatively few sources that define building occupancy schedules and number of occupants per building or space type. More importantly, these sources define traditional schedules that are likely not to reflect the true occupancy of a given building. We construct traffic-based occupancy schedules which are more responsive to changes in mobility patterns, and which can realistically estimate occupant arrivals, departures, and counts in individual buildings.

Berres, Andy↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2005 Spokane and Kootenai County Regional Travel

The 2005 Spokane and Kootenai County Regional Travel Survey is a comprehensive survey of the travel patterns of households in Spokane County, Washington, and Kootenai County, Idaho. The survey was conducted for the Spokane Regional Transportation Council over a three-month period from April through June 2005. The data are drawn from 1,828 households within Spokane and Kootenai counties and contain information about 4,488 household members, 3,974 vehicles, and 19,638 trips made during a 24-hour period. The survey relied on the willingness of study area residents to 1) provide demographic information about their household, its members, and its vehicles during the recruitment stage and 2) record all travel for a specific 24-hour period during the retrieval stage. Respondents were asked to provide detailed household information, including number of occupants, type of dwelling unit, number of vehicles available to household occupants, as well as the year and body type for each vehicle.

1Hz data↗

Automated vehicle occupancy detection

Described herein are systems and methods for detecting the number of occupants in a vehicle. The detecting may be performed using a camera and a processing device. The detecting may be anonymous and the image of the interior of the vehicle is not stored on the processing device.

Moniot, Matthew Louis↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Development and Application of Schema Based Occupant-Centric Building Performance Metrics

Occupant behavior can significantly influence the operation and performance of buildings. Many occupant-centric key performance indicators (KPIs) rely on having accurate counts of the number of occupants in a building, which is very different to how occupancy information is currently collected in the majority of buildings today. To address this gap, the authors develop a standardized methodology for the calculation of percent space utilization for buildings, which is formulated with respect to two prevalent operational data schemas: the Brick Schema and Project Haystack. The methodology is scalable across different levels of spatial granularity and irrespective of sensor placement. Moreover, the methods are intended to make use of typical occupancy sensors that capture presence level occupancy and not counts of people. Since occupant-hours is a preferable metric to use in KPI calculations, a method to convert between percent space utilization and occupant-hours using the design occupancy for a space is also developed. The methodology is demonstrated on a small commercial office space in Boulder, Colorado using data collected between June 2018 and February 2019. A multiple linear regression is performed that shows strong evidence for a relationship between building energy consumption and percent space utilization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Counting Occupants Using Network Technology (COUNT) v0.1

With this COUNT software, we can run a simple query on a campus's Wireless Local Area Network controller (WLAN controller) to obtain the number of connected devices per access point across the whole campus and this can be used as a proxy for the actual number of occupants in the campus. The software supports user defined functions to parse access point names to retrieve more information (e.g.: building names, room numbers etc.) and also allows post-processing of the data.

Prakash, AnandKrishnan↗

Counting Occupants Using Network Technology (COUNT) v0.1

With this COUNT software, we can run a simple query on a campus's Wireless Local Area Network controller (WLAN controller) to obtain the number of connected devices per access point across the whole campus and this can be used as a proxy for the actual number of occupants in the campus. The software supports user defined functions to parse access point names to retrieve more information (e.g.: building names, room numbers etc.) and also allows post-processing of the data.

Pritoni, Marco↗

2005 Tahoe Regional Household Travel Survey

The 2005 Tahoe Regional Household Travel Survey is a comprehensive survey of the travel patterns of households in the Tahoe Basin region of California and Nevada. The survey was conducted for the Tahoe Regional Planning Agency over a four-month period, from June through September 2005. This collection contains two sets of travel data: 1) a survey of 1,220 permanent households within the Tahoe Basin region and 2) a subset survey of 125 seasonal households within the same area. The permanent resident dataset contains information about 2,732 household members, 2,471 vehicles, and 11,048 trips made during a 24-hour period. The seasonal resident subset features 726 trip observations and information about 229 household members and 185 vehicles. The survey relied on the willingness of study area residents to 1) provide demographic information about their household, its members, and its vehicles and 2) document all travel for each household member, regardless of age, over an assigned 24-hour period. During the recruitment phase, respondents were asked to provide detailed household information, including permanent or seasonal resident status, number of household occupants, type of dwelling unit, number of vehicles available to household members, as well as the year, body type, and fuel type of each vehicle. Survey participants received mailed travel logs to aid in documenting travel information for the 24-hour assessment period. Respondents were instructed to record their mode of transportation, trip purpose, number of passengers, departure and arrival times, activities at each trip destination, ride fare, and parking costs. Demographic information for this study includes age, gender, income, education, and employment status.

1Hz data↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

Genetic variation and genetic complexity of nodule occupancy in soybean inoculated with USDA110 and USDA123 rhizobium strains

Abstract Background Symbiotic nitrogen fixation differs among Bradyrhizobium japonicum strains. Soybean inoculated with USDA123 has a lower yield than strains known to have high nitrogen fixation efficiency, such as USDA110. In the main soybean-producing area in the Midwest of the United States, USDA123 has a high nodule incidence in field-grown soybean and is competitive but inefficient in nitrogen fixation. In this study, a high-throughput system was developed to characterize nodule number among 1,321 Glycine max and 69 Glycine soja accessions single inoculated with USDA110 and USDA123. Results Seventy-three G. max accessions with significantly different nodule number of USDA110 and USDA123 were identified. After double inoculating 35 of the 73 accessions, it was observed that PI189939, PI317335, PI324187B, PI548461, PI562373, and PI628961 were occupied by USDA110 and double-strain nodules but not by USDA123 nodules alone. PI567624 was only occupied by USDA110 nodules, and PI507429 restricted all strains. Analysis showed that 35 loci were associated with nodule number in G. max when inoculated with strain USDA110 and 35 loci with USDA123. Twenty-three loci were identified in G. soja when inoculated with strain USDA110 and 34 with USDA123. Only four loci were common across two treatments, and each locus could only explain 0.8 to 1.5% of phenotypic variation. Conclusions High-throughput phenotyping systems to characterize nodule number and occupancy were developed, and soybean germplasm restricting rhizobium strain USDA123 but preferring USDA110 was identified. The larger number of minor effects and a small few common loci controlling the nodule number indicated trait genetic complexity and strain-dependent nodulation restriction. The information from the present study will add to the development of cultivars that limit USDA123, thereby increasing nitrogen fixation efficiency and productivity.

59 BASIC BIOLOGICAL SCIENCES↗

Downward quantum learning from element 118: Automated generation of Fermi–Löwdin orbitals for all atoms

A new algorithm based on a rigorous theorem and quantum data computationally mined from element 118 guarantees automated construction of initial Fermi–Löwdin-Orbital (FLO) starting points for all elements in the Periodic Table. It defines a means for constructing a small library of scalable FLOs for universal use in molecular and solid-state calculations. The method can be systematically improved for greater efficiency and for applications to excited states such as x-ray excitations and optically silent excitations. FLOs were introduced to recast the Perdew–Zunger self-interaction correction (PZSIC) into an explicit unitarily invariant form. The FLOs are generated from a set of N quasi-classical electron positions, referred to as Fermi-Orbital descriptors (FODs), and a set of N-orthonormal single-electron orbitals. FOD positions, when optimized, minimize the PZSIC total energy. However, creating sets of starting FODs that lead to a positive definite Fermi orbital overlap matrix has proven to be challenging for systems composed of open-shell atoms and ions. The proof herein guarantees the existence of a FLOSIC solution and further guarantees that if a solution for N electrons is found, it can be used to generate a minimum of N – 1 and a maximum of 2 N – 2 initial starting points for systems composed of a smaller number of electrons. As a result, applications to heavy and super-heavy atoms are presented. All starting solutions reported here were obtained from a solution for element 118, Oganesson.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dialing in Catalytic Sites on Metal Organic Framework Nodes: MIL-53(Al) and MIL-68(Al) Probed with Methanol Dehydration Catalysis

Many metal organic frameworks (MOFs) incorporate metal oxide clusters as nodes. Node sites where linkers are missing can be catalytic sites. We now show how to dial in the number and occupancy of such sites in MIL-53 and MIL-68, which incorporate aluminum-oxide-like nodes. Here, the methods involve modulators used in synthesis and postsynthesis reactions to control the modulator-derived groups on these sites. We illustrate the methods using formic acid as a modulator, giving formate ligands on the sites, and these can be removed to leave μ 2 -OH groups and open Lewis acid sites. Methanol dehydration was used as a catalytic reaction to probe these sites, with infrared spectra giving evidence of methoxide ligands as reaction intermediates. Control of node surface chemistry opens the door for placement of a variety of ligands on a wide range of metal oxide cluster nodes for dialing in reactivity and catalytic properties of a potentially immense class of structurally well-defined materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The many-body expansion for metals. I. The alkaline earth metals Be, Mg, and Ca

We examine the many-body expansion (MBE) for alkaline earth metal clusters, Be n , Mg n , Ca n ( n = 4, 5, 6), at the Møller–Plesset second order perturbation theory, coupled-cluster singles and doubles with perturbative triples, multi-reference perturbation theory, and multi-reference configuration interaction levels of theory. The magnitude of each term in the MBE is evaluated for several geometrical configurations. We find that the behavior of the MBE for these clusters depends strongly on the geometrical arrangement and, to a lesser extent, on the level of theory used. Another factor that affects the MBE is the in situ (ground or excited) electronic state of the individual atoms in the cluster. For most geometries, the three-body term is the largest, followed by a steady decrease in absolute energy for subsequent terms. Though these systems exhibit non-negligible multi-reference effects, there was little qualitative difference in the MBE when employing single vs multi-reference methods. Useful insights into the connectivity and stability of these clusters have been drawn from the respective potential energy surfaces and quasi-atomic orbitals for the various dimers, trimers, and tetramers. Through these analyses, we investigate the similarities and differences in the binding energies of different-sized clusters for these metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

N -representability violations in truncated equation-of-motion coupled-cluster methods

One-electron reduced density matrices (1RDMs) from equation-of-motion (EOM) coupled-cluster with single and double excitations (CCSD) calculations are analyzed to assess their N-representability (i.e., whether they are derivable from a physical N-electron state). We identify EOM-CCSD stationary states whose 1RDMs violate either ensemble-state N-representability conditions or pure-state conditions known as generalized Pauli constraints. As such, these 1RDMs do not correspond to any physical N-electron state. Unphysical states are also encountered in the course of time-dependent EOM-CC simulations; when an external field drives transitions between a pair of stationary states with pure-state N-representable 1RDMs, the 1RDM of the time-dependent state can violate ensemble-state conditions. Furthermore, these observations point to potential challenges in interpreting the results of time-dependent EOM-CCSD simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗