Search NASASearch

SEARCH · Search NASA

Results for “Optical Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design of an optical amplifier for amplified OSC in IOTA facility at Fermilab

Optical stochastic cooling (OSC) is a cutting-edge beam cooling technology to reduce, control the 3 dimensional spread and the motion of particle beams. It has recently been successfully, experimentally, demonstrated in Fermilab's IOTA storage ring, marking a major step forward in beam cooling. OSC has the potential to significantly improve both the performance and flexibility as a beam cooling system. One promising way to boost OSC performance is by adding a high-gain optical amplifier. However, this amplifier must be carefully designed to meet the specific constraints of the OSC system. A major challenge lies in the limited optical delay, which is just 6 mm for the case of IOTA, set by the beam bypass, restricts us to use a short-length gain medium. This, along with IOTA’s high repetition rate and the relatively long duration of the optical pulses, limits the peak power available for the pump laser without damaging the crystal, which is crucial for achieving strong nonlinear gain. Additionally, it's essential to preserve the phase coherence of the undulator radiation during amplification, which further complicates the amplifier design. This report details a specialized amplifier setup that addresses these challenges, includes simulations of the integrated system, and summarizes the latest experimental progress and results.

Mondal, Abhishek [Fermilab]

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION

Design and development of optical modules for the BUTTON-30 detector

BUTTON-30 is a neutrino detector demonstrator located in the STFC Boulby underground facility in the north-east of England. The main goal of the project is to deploy and test the performance of the gadolinium-loaded water-based liquid scintillator for neutrino detection in an underground environment. This will pave the way for a future large-volume neutrino observatory that can also perform remote monitoring of nuclear reactors for nonproliferation. This paper describes the design and construction of the watertight optical modules of the experiment.

COMSOL simulations

Physical Modeling and Design of a Nonvolatile Optically Gated High‐Power Diamond Transistor

In this work, we present the theory and modeling framework of a diamond optically gated junction field‐effect transistor (DOGFET). The device utilizes nitrogen substitutional centers in type‐1b diamond to optically modulate a p‐ boron doped diamond channel. Using sub‐gap lasers with intensities as low as 100 W/cm 2 , electrons are optically excited from substitutional nitrogen sites to the conduction band of the diamond substrate, thus enabling the optical gate to exercise control on modulating the space‐charge region at the junction and therefore the channel conductivity. We show that the device can deliver a current of 7 μA/μm, or equivalently 1750 A/cm 2 , while switching at a frequency greater than 100 kHz, in a form factor of 5 μm 2 . The breakdown voltage is found to be greater than 1850 V, with a breakdown field strength of ~13 MV/cm. Moreover, the device supports nonvolatile operation with a “memory effect” enabling single transistor state retention. The presented simulation framework provides a physically grounded insight into the limits and opportunities of optoelectronic diamond systems.

Engineering - Electronic and electrical engineerin

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC

Inverse design for waveguide dispersion with a differentiable mode solver

Inverse design of optical components based on adjoint sensitivity analysis has the potential to address the most challenging photonic engineering problems. However, existing inverse design tools based on finite-difference-time-domain (FDTD) models are poorly suited for optimizing waveguide modes for adiabatic transformation or perturbative coupling, which lies at the heart of many important photonic devices. Among these, dispersion engineering of optical waveguides is especially challenging in ultrafast and nonlinear optical applications involving broad optical bandwidths and frequency-dependent anisotropic dielectric material response. In this work, we develop gradient back-propagation through a general-purpose electromagnetic eigenmode solver and use it to demonstrate waveguide dispersion optimization for second harmonic generation with maximized phase-matching bandwidth. This optimization of three design parameters converges in eight steps, reducing the computational cost of optimization by ∼100x compared to exhaustive search and identifying new designs for broadband optical frequency doubling of laser sources in the 1.3–1.4 µm wavelength range. Furthermore, we demonstrate that the computational cost of gradient back-propagation is independent of the number of parameters, as required for optimization of complex geometries. This technique enables practical inverse design for a broad range of previously intractable photonic devices.

Gray, Dodd (ORCID:000000030469599X)

Automation of Nanoparticle Synthesis Processes in a Plasma Environment Using LabVIEW

This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.

PECVD

Effect of Stoichiometry on the Structure and Polarization of BaTiO 3

Barium titanate (BaTiO 3 ) is a material of interest for photonic device applications due to its strong optical non-linearity. However, BaTiO 3 -based devices have not found widespread adoption, in part due to the challenges associated with synthesizing high quality thin-films. Here, high-resolution scanning transmission electron microscope (STEM) imaging is used to investigate the atomic structure of both on- and off-stoichiometric BaTiO 3 synthesized by molecular beam epitaxy (MBE). Here, this investigation reveals an asymmetry in the way the BaTiO 3 atomic lattice accommodates off-stoichiometry growth and unveils features beyond what is expected from diffraction or surface characterization techniques. Excess titanium incorporates into the BaTiO 3 lattice to form pervasive defects despite titanium-rich films having a low surface roughness and high-quality appearance in diffraction. Excess barium forms a rough, water-soluble surface layer but does not significantly impact the quality of the BaTiO 3 lattice. STEM is used to map titanium atom displacement in real-space. The average displacement distance is 30–60 pm in the strained thin-films, higher than the <20 pm displacement in bulk BaTiO 3 . Additionally, the titanium atom displacement direction deviates from the c-axis of the unit cell, which may have implications for the material's electro-optic tensor and thus for electro-optic device design.

Cavanagh, Ashley E. [Harvard Univ., Cambridge, MA

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING

Applying Mechanistic Co-Design Towards Room-Temperature Organic, Optical, and Multiple-Center Molecular Qubits

The next generation of qubits, the building blocks of quantum technologies, are designed using molecules. Molecular qubits have natural advantages over solid-state equivalents in biological and chemical sensing. Chemistry allows the properties of molecular qubits to be fine-tuned, such as the ability of multiple qubits to work together using qubit-qubit coupling. Molecules and structures containing multiple qubits, made from both inorganic and organic elements, are developed in this work to bring quantum technologies closer to room-temperature operation. The goal is achieved by understanding how the core of the qubit, known as spin, interacts with the vibrating parts of the molecule, other spins, and the surrounding environment. A combined approach involving theory, spectroscopy, and synthesis is used to achieve the design goal.

36 MATERIALS SCIENCE

Experimental measurements for extracting nonlinear invariants

Nonlinear integrable optics are a promising alternative approach to lattice design. The integrable optics test accelerator (IOTA) at Fermilab has been constructed for dedicated studies of magnetostatic elliptical elements as described by Danilov and Nagaitsev. The most compelling verification of correct implementation of the NIO lattice is direct observation of the analytically expected invariants. This report outlines the experimental and analytical methods for extracting the nonlinear invariants of motion from data gathered in the last IOTA run.

43 PARTICLE ACCELERATORS

Artificial intelligence driven laser parameter search: Inverse design of photonic surfaces using greedy surrogate-based optimization

Photonic surfaces designed with specific optical characteristics are becoming increasingly crucial for novel energy harvesting and storage systems. The design of these surfaces can be achieved by texturing materials using lasers. The optimal adjustment of laser fabrication parameters to achieve target surface optical properties is an open challenge. Thus, we develop a surrogate-based optimization approach. Our framework employs the Random Forest algorithm to model the forward relationship between the laser fabrication parameters and the resulting optical characteristics. During the optimization process, we use a greedy, prediction-based exploration strategy that iteratively selects batches of laser parameters to be used in experimentation by minimizing the predicted discrepancy between the surrogate model’s outputs and the user-defined target optical characteristics. This strategy allows for efficient identification of optimal fabrication parameters without the need to model the error landscape directly. We demonstrate the efficiency and effectiveness of our approach on two synthetic benchmarks and two specific experimental applications of photonic surface inverse design targets. By calculating the average performance of our algorithm compared to other state of the art optimization methods, we show that our algorithm performs, on average, twice as well across all benchmarks. Additionally, a warm starting inverse design technique for changed target optical characteristics enhances the performance of the introduced approach.

97 MATHEMATICS AND COMPUTING