Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Modal focal adaptive optics for Bessel-focus two-photon fluorescence microscopy

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM. Measuring and correcting aberration using a spatial light modulator placed in conjugation with the focal plane of the microscope objective, MFAO employs Zernike annular polynomials — a first in AO implementation — to achieve performance on par with a previous zonal AO method, but with a notably simplified optical configuration. We validated the performance of MFAO in correcting artificial and sample-induced aberrations, as well as in in vivo imaging of zebrafish larvae and mouse brains. By expanding the application of modal AO to annular pupils as well as aberration measurement and correction to a wavefront modulator at the objective focal plane, MFAO represents a notable advancement in the implementation of AO in microscopy.

47 OTHER INSTRUMENTATION↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing Of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction, to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary ,of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Fast widefield imaging of neuronal structure and function with optical sectioning in vivo

Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.

42 ENGINEERING↗

Sources of Emittance in RF Photocathode Injectors

Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

43 PARTICLE ACCELERATORS↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Wavefront Sensing via High Speed DSP

Future light-weighted and segmented primary mirror systems require active optical control to maintain mirror positioning and figure to within nanometer tolerances. Current image-based wavefront sensing approaches rely on post-processing techniques to return an estimate of the aberrated optical wavefront with accuracies to the nanometer level. But the lag times between wavefront sensing, and then control, contributes to a significant latency in the wavefront sensing implementation. In this analysis we demonstrate accelerated image-based wavefront sensing performance using multiple digital signal processors (DSP's). The computational architecture is discussed as well as the heritage leading to the approach.

Smith, J. Scott↗

Design and Modeling of the Off-Axis Parabolic Deformable Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Communication↗

Design and Modeling of the Off-Axis Parabolic Deformable (OPD) Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Subedi, Hari↗

Fabrication of MgF2 and LiF windows for the Hubble Space Telescope Imaging Spectrograph

Two prototype test windows (MgF2 and LiF) to be used on the 75-mm UV MAMA detector tubes for the Hubble Space Telescope Imaging Spectrograph are described. The spatial and optical constraints of this instrument dictate that the thickness of the window materials be no greater than 2-3 mm to achieve a minimum 50-percent transmission at hydrogen Lyman alpha (121.6 nm), and that the window must be domed to minimize optical aberrations and provide structural strength. The detector window has an input diameter of about 100 mm with a radius-of-curvature of 70 mm. The manufacturing processes involved in the fabrication of these windows is discussed, as well as test programs (optical and structural) to be performed at Goddard Space Flight Center.

Gormley, Daphne↗

A Method for Measuring Optical Distortion in Curved Optical Surfaces using Moiré Interferometry

In FY2020, KSC’s Applied Physics Lab created a computer based image processing system to allow inspection of the new visors being developed for the Artemis Program. This system was based on an ASTM standard where the distortion of an image is used to determine the optical aberrations in a visor, but this approach is restricted to small fields-of-view (small areas of the visor) and is limited in its ability to reliably detect and measure distortion. From our experience with flat surface inspection, we know that other optical techniques can offer higher sensitivity and accuracy. [1] This memorandum describes a method to model and measure the distortion in curved optical surfaces using moir´e interferometry. We were able to apply this process to examine samples of the xEMU Artemis astronaut helmets. Design details are provided along with examples to illustrate performance.

Optical Distortion↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Impact of shorter wavelengths on optical quality for laws

This study explores parametrically as a function of wavelength the degrading effects of several common optical aberrations (defocus, astigmatism, wavefronttilts, etc.), using the heterodyne mixing efficiency factor as the merit function. A 60 cm diameter aperture beam expander with an expansion ratio of 15:1 and a primary mirror focal ratio of f/2 was designed for the study. An HDOS copyrighted analysis program determined the value of merit function for various optical misalignments. With sensitivities provided by the analysis, preliminary error budget and tolerance allocations were made for potential optical wavefront errors and boresight errors during laser shot transit time. These were compared with the baseline 1.5 m CO2 laws and the optical fabrication state of the art (SOA) as characterized by the Hubble Space Telescope. Reducing wavelength and changing optical design resulted in optical quality tolerances within the SOA both at 2 and 1 micrometer. However, advanced sensing and control devices would be necessary to be tightened by a factory of 1.8 for a 2 micrometer system and by 3.6 for a 1 micrometer system relative to the baseline CO2 LAWS. Available SOA components could be used for operation at 2 micrometers but operation at 1 micrometer does not appear feasible.

Wissinger, Alan B.↗

High Precision Thermal, Structural and Optical Analysis of an External Occulter Using a Common Model and the General Purpose Multi-Physics Analysis Tool Cielo

The efficient simulation of multidisciplinary thermo-opto-mechanical effects in precision deployable systems has for years been limited by numerical toolsets that do not necessarily share the same finite element basis, level of mesh discretization, data formats, or compute platforms. Cielo, a general purpose integrated modeling tool funded by the Jet Propulsion Laboratory and the Exoplanet Exploration Program, addresses shortcomings in the current state of the art via features that enable the use of a single, common model for thermal, structural and optical aberration analysis, producing results of greater accuracy, without the need for results interpolation or mapping. This paper will highlight some of these advances, and will demonstrate them within the context of detailed external occulter analyses, focusing on in-plane deformations of the petal edges for both steady-state and transient conditions, with subsequent optical performance metrics including intensity distributions at the pupil and image plane.

integrated modeling↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Impact of shorter wavelengths on optical quality for laws

This study explores parametrically as a function of wavelength the degrading effects of several common optical aberrations (defocus, astigmatism, wavefront tilts, etc.), using the heterodyne mixing efficiency factor as the merit function. A 60 cm diameter aperture beam expander with an expansion ratio of 15:1 and a primary mirror focal ratio of f/2 was designed for the study. An HDOS copyrighted analysis program determined the value of merit function for various optical misalignments. With sensitivities provided by the analysis, preliminary error budget and tolerance allocations were made for potential optical wavefront errors and boresight errors during laser shot transit time. These were compared with the baseline l.5 m CO2 LAWS and the optical fabrication state of the art (SOA) as characterized by the Hubble Space Telescope. Reducing wavelength and changing optical design resulted in optical quality tolerances within the SOA both at 2 and 1 micrometers. However, advanced sensing and control devices would be necessary to maintain on-orbit alignment. Optical tolerance for maintaining boresight stability would have to be tightened by a factor of 1.8 for a 2 micrometers system and by 3.6 for a 1 micrometers system relative to the baseline CO2 LAWS. Available SOA components could be used for operation at 2 micrometers but operation at 1 micrometers does not appear feasible.

Wissinger, Alan B.↗

Dynamic super-resolution structured illumination imaging in the living brain

Cells in the brain act as components of extended networks. Therefore, to understand neurobiological processes in a physiological context, it is essential to study them in vivo. Super-resolution microscopy has spatial resolution beyond the diffraction limit, thus promising to provide structural and functional insights that are not accessible with conventional microscopy. However, to apply it to in vivo brain imaging, we must address the challenges of 3D imaging in an optically heterogeneous tissue that is constantly in motion. We optimized image acquisition and reconstruction to combat sample motion and applied adaptive optics to correcting sample-induced optical aberrations in super-resolution structured illumination microscopy (SIM) in vivo. Lastly, we imaged the brains of live zebrafish larvae and mice and observed the dynamics of dendrites and dendritic spines at nanoscale resolution.

60 APPLIED LIFE SCIENCES↗