At least 55 records · Page 3

An Optimized Input/Output-Constrained Control Design With Application to Microgrid Operation

In this paper, a nonlinear control design is presented for systems whose input and output vectors are saturated. The proposed synthesis includes an optimal tracker as the seed controller and explicitly imposes all the relevant constraints on system input, on the rate of change in the input, and on system output by using the tools of barrier functions, input-output feedback linearization, comparison argument, Lyapunov argument, and a real-time constrained optimization. The proposed design is applied to microgrid operation with high penetration of renewable generation, where net load and variable generation must be balanced and the microgrid should be operated at an optimal or near-optimal performance level. Since traditional generation has a limited ramping rate, battery storage devices and demand responses become necessary to effectively deal with variability of renewable generation and to maintain frequency stability, but their capacities are also limited. Finally,it is shown that the proposed design is effective for coordinated control of traditional generation, storage and demand response so that the power system frequency is guaranteed to be within the required operational limits and that renewable curtailment is eliminated or minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Algorithmic considerations of integrated design for CSI on a hypercube architecture

An approach is presented to the integrated design problem for actively controlled large, flexible mechanical systems for which Control Structure Interaction (CSI) problems are of concern. The two coupled design problems were identified as the optimal Structural Design problem the optimal Controller Design problem. These two problems can be addressed within a decision making loop that would consider each separately, and then sequentially analyze the effects of one on the other. Embedded in such a loop would be the simulation and coordination tasks as part of the decision tools required in a total (software) package. All of the above are compute-intensive tasks. In any such task, possible decompositions and gains due to the inherent parallelism have to be exploited. The problems under consideration, as applied to large flexible mechanical structures, are particularly suited to be mapped onto multicomputer systems in a hypercube topology.

Oezguener, UE.↗

Optimal design and control strategies for novel combined heat and power (CHP) fuel cell systems. Part I of II, datum design conditions and approach.

Energy network optimization (ENO) models identify new strategies for designing, installing, and controlling stationary combined heat and power (CHP) fuel cell systems (FCSs) with the goals of (1) minimizing electricity and heating costs for building owners and (2) reducing emissions of the primary greenhouse gas (GHG) - carbon dioxide (CO{sub 2}). A goal of this work is to employ relatively inexpensive simulation studies to discover more financially and environmentally effective approaches for installing CHP FCSs. ENO models quantify the impact of different choices made by power generation operators, FCS manufacturers, building owners, and governments with respect to two primary goals - energy cost savings for building owners and CO{sub 2} emission reductions. These types of models are crucial for identifying cost and CO{sub 2} optima for particular installations. Optimal strategies change with varying economic and environmental conditions, FCS performance, the characteristics of building demand for electricity and heat, and many other factors. ENO models evaluate both 'business-as-usual' and novel FCS operating strategies. For the scenarios examined here, relative to a base case of no FCSs installed, model results indicate that novel strategies could reduce building energy costs by 25% and CO{sub 2} emissions by 80%. Part I of II articles discusses model assumptions and methodology. Part II of II articles illustrates model results for a university campus town and generalizes these results for diverse communities.

30 DIRECT ENERGY CONVERSION↗

Aircraft control-display analysis and design using the optimal control model of the human pilot

The use of the optimal control model (OCM) of the human pilot as a design tool is discussed. A novel procedure for the assignment and selection of model parameters in the absence of experimental data is proposed. A technique for partitioning a weakly coupled, multiaxis task into approximate state-uncoupled, single-axis tasks is introduced. The resulting modeling technique is utilized in the design and analysis of an aircraft flight-director system. This flight-director design technique differs from previous related work using the OCM in that considerable effort is devoted to ensuring that the OCM-designed director exhibits the desirable frequency-domain characteristics associated with experimentally verified classical designs (e.g., K/s 'effective vehicle' characteristics, noninteracting controls). The implications of the technique in the design of automatic flight control systems which employ the human pilot as a performance assessor and failure detector are briefly discussed.

Hess, R. A.↗

Optimal design and control strategies for novel combined heat and power (CHP) fuel cell systems. Part II of II, case study results.

Innovative energy system optimization models are deployed to evaluate novel fuel cell system (FCS) operating strategies, not typically pursued by commercial industry. Most FCS today are installed according to a 'business-as-usual' approach: (1) stand-alone (unconnected to district heating networks and low-voltage electricity distribution lines), (2) not load following (not producing output equivalent to the instantaneous electrical or thermal demand of surrounding buildings), (3) employing a fairly fixed heat-to-power ratio (producing heat and electricity in a relatively constant ratio to each other), and (4) producing only electricity and no recoverable heat. By contrast, models discussed here consider novel approaches as well. Novel approaches include (1) networking (connecting FCSs to electrical and/or thermal networks), (2) load following (having FCSs produce only the instantaneous electricity or heat demanded by surrounding buildings), (3) employing a variable heat-to-power ratio (such that FCS can vary the ratio of heat and electricity they produce), (4) co-generation (combining the production of electricity and recoverable heat), (5) permutations of these together, and (6) permutations of these combined with more 'business-as-usual' approaches. The detailed assumptions and methods behind these models are described in Part I of this article pair.

30 DIRECT ENERGY CONVERSION↗

Optimal design of control systems for prevention of aircraft flight departure

Control system design for general nonlinear flight dynamic models is considered through numerical simulation. The design is accomplished through a numerical optimizer coupled with analysis of flight dynamic equations. In the analysis, the general nonlinear flight dynamic equations with nonlinear aerodynamics are numerically integrated; and the dynamic characteristics needed in the optimization process are then identified from the dynamic response. To assure a reasonable solution, the initial input values of the design variables are estimated through a sensitivity analysis. To demonstrate the method, the pitch departure prevention for an F-16 configuration is demonstrated.

Lan, C. Edward↗

Optimal Flow Control Design

In support of the Blended-Wing-Body aircraft concept, a new flow control hybrid vane/jet design has been developed for use in a boundary-layer-ingesting (BLI) offset inlet in transonic flows. This inlet flow control is designed to minimize the engine fan-face distortion levels and the first five Fourier harmonic half amplitudes while maximizing the inlet pressure recovery. This concept represents a potentially enabling technology for quieter and more environmentally friendly transport aircraft. An optimum vane design was found by minimizing the engine fan-face distortion, DC60, and the first five Fourier harmonic half amplitudes, while maximizing the total pressure recovery. The optimal vane design was then used in a BLI inlet wind tunnel experiment at NASA Langley's 0.3-meter transonic cryogenic tunnel. The experimental results demonstrated an 80-percent decrease in DPCPavg, the reduction in the circumferential distortion levels, at an inlet mass flow rate corresponding to the middle of the operational range at the cruise condition. Even though the vanes were designed at a single inlet mass flow rate, they performed very well over the entire inlet mass flow range tested in the wind tunnel experiment with the addition of a small amount of jet flow control. While the circumferential distortion was decreased, the radial distortion on the outer rings at the aerodynamic interface plane (AIP) increased. This was a result of the large boundary layer being distributed from the bottom of the AIP in the baseline case to the outer edges of the AIP when using the vortex generator (VG) vane flow control. Experimental results, as already mentioned, showed an 80-percent reduction of DPCPavg, the circumferential distortion level at the engine fan-face. The hybrid approach leverages strengths of vane and jet flow control devices, increasing inlet performance over a broader operational range with significant reduction in mass flow requirements. Minimal distortion level requirements are met using vanes alone, avoiding engine stall and increasing robustness of this hybrid inlet flow control approach. This design applies to aerospace applications needing flush-mounted boundary-layer-ingesting inlets.

Allan, Brian↗

Design, Optimization, and Control of a 100 kW Electric Traction Motor Meeting or Exceeding DOE 2025 Targets

The overall objective of the electric motor portion of the Electric Drives Technology consortium is to research, develop, and test electric motors for use in electric vehicle applications capable of a peak power greater than 100 kW, power density greater than or equal to 50 kW/l, and a cost less than 3.3 $/kW. To meet the electric traction motor power density and cost targets a number of approaches were pursued simultaneously throughout the course of this project which address all of the major volumetric power density variables. The specific research thrusts at the Illinois Institute of Technology (IIT) are the following: multiphysics design for increased power density through maximum utilization of active materials, synthesis of electric machine windings and PM flux barriers with controlled space harmonics, high slot fill windings for increased current loadings or efficiency, aggressive cooling strategies, and design studies and prototype construction of candidate electric machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AI-Based Optimal Design and Controls Can Greatly Reduce Carbon Emissions and Enhance Resilience in Residential Communities in Cold Climates

Net-zero energy residential communities are crucial for achieving decarbonization goals, but the high-penetration photovoltaic (PV) in those communities is posing challenges to the distribution grid. Traditional design and operation of net-zero communities rely on rule-of-thumb methods and may not work in complex scenarios. Artificial intelligence and machine learning methods can optimally size PV for net-zero energy, identify user preferences and usage patterns, and fully unlock the potential of distributed energy resources to address distribution grid issues.

artificial intelligence↗