Search NASA⌕ Search

SEARCH · Search NASA

Results for “Outdoor Performance and Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

45 records · Page 3

Photovoltaic Module Imaging for Hail Damage Assessment with Multi-Year Follow Up

Outdoor-aged photovoltaic modules that have experienced golf-ball sized hail are characterized by flash testing and photoluminescence, electroluminescence, thermal, and ultraviolet fluorescence imaging. These measurements were performed immediately after the hailstorm and then again after another two years and four years in the field. The modules originally experienced different ranges of hail damage with some having cracks on approximately half of the cells and some having few to no cracked cells. Flash testing shows that the hail-damaged modules with the most cracked cells have 3 to 4% less power than those with the least damage. After four more years in the outdoor climate of Golden, Colorado since the hailstorm, all of the modules still exhibit similar relative power and amounts of cell cracking, suggesting that the hail damage has only initially reduced power but has not yet increased the degradation rate.

electroluminescence↗

Experimental Considerations for Estimating Degradation in PV Modules

Carefully controlled laboratory experiments and measurements can enable the determination of acceleration factors suitable for extrapolation to durability and performance of a fielded PV module. Ideally, a single mechanism can be identified with appropriate acceleration factors for extrapolation to the field. However, even with a single mechanism, the inherent uncertainty in these factors leads to uncertainty in the extrapolation which is greater the higher the acceleration factor. This course will explain how because of the wide range of acceleration factors for a given degradation mode, utilizing acceleration factors greater than about 10x will typically lead to unacceptable uncertainty in the results. Therefore, if even just a rank ordering of materials is desired, acceleration factors must be minimized which requires a good general understanding of the scale of the different acceleration factors for the degradation mode of interest. In this tutorial we will discuss what the different purposes are for many of the accelerated stress tests used today. E.g., what is a qualification test, a highly accelerated stress test, a rank ordering test, or a service life prediction test. We will discuss how one can understand the relationship between test results and expected field performance. A single accelerated stress test condition cannot duplicate outdoor exposure for all possible degradation pathways; therefore, one must use targeted evaluation of material properties at different stress levels to determine the relevant acceleration factors and fit it to a model. We will also discuss how to interpret the results of experiments understanding what is relevant/not relevant, or not e valuated in a test. There are many common error people make in their test interpretations because they push the stress levels to be too harsh. This creates biases and can mask the relevant failure modes and mechanisms or will erroneously lead one to over design materials against things that aren't relevant. Several case studies will be presented to illustrate appropriate interpretation of accelerated stress testing results.

degradation↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Hybrid Tandem Photovoltaics

Tandem solar cell structures are the only strategy demonstrated to surpass the detailed balance efficiency limit of high-quality single-junction solar cells. To continue to improve the efficiencies of cost-effective terrestrial solar power, hybrid tandems of dissimilar subcells are being considered by many around the world, especially designs that incorporate silicon solar cells as a bottom subcell. In this project, we studied a wide variety of tandem design possibilities including those with three-terminal (3T) and four-terminal (4T) configurations. The use of 3T and 4T designs could be useful for efficient and economical hybrid tandem designs that utilize the best available subcell materials such as emerging perovskite materials. Three-terminal configurations, in particular, have not been sufficiently studied previously. We have laid the foundational groundwork in this project for understanding the operation of 3T tandems: developing a taxonomy for naming, a methodology for measuring and interconnecting, and models for simply characterizing 3T tandems. Electrical and optical subcell coupling between the subcells was also measured and modeled. An important part of this work was the fabrication of novel example tandem structures, including 4T GaAs/Si, 3T GaInP/Si, 3T GaAs/Si, and 3T GaInP/GaAs devices. Using these high-quality tandem cells, we have been able to clearly demonstrate the achievability of high-efficiencies, and subtle physical effects such as photon recycling and luminescent coupling. We have developed and demonstrated essential building-block tools such as transparent conductive adhesives (TCA) and 3T silicon bottom cells with interdigitated back contacts (IBC) that can also be used in many other tandem designs. We have tested the reliability of these tools and devices under standardized testing and outdoor measurements. We have found 4T GaAs/Si tandems to be relatively straightforward to fabricate and robust in real-world outdoor conditions. While we have demonstrated working hybrid 3T III-V/TCA/Si IBC tandems, we experienced low yields even with our best process flows yet. Further work is still needed to improve the processing yield of these devices. We therefore also created tandem cells using an all-III-V 3T tandem process which was very robust with high yields, allowing for the creation of voltage-matched strings in many different configurations using 8 nearly identical 3T tandems. Using these robust 3T tandem examples, we were able measure and precisely characterize 3T tandem behaviors to predict their operation under changing spectrum and temperature. The optoelectronic equivalent-circuit model was shown to be very general and applicable to hybrid tandems, and encompassed the operation 3T Si IBC cells. This general model has been distributed to the public in as open-source Python-based software called PVcircuit. We have calculated the implications of these new tandem device designs on the real-world energy production and shown how the relative performance of different tandem configurations is situational and can be engineered using the tools developed here.

14 SOLAR ENERGY↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Recycling the Energy of Indoor Light: Highly Efficient Organic Photovoltaics via a Ternary Strategy

A ternary approach in organic photovoltaics (OPV) is simple and reliable to effectively tune the optical, electrical and morphological properties of the photoactive layer for high efficiency as well as long-term stability under 1 sun. However, there have been few papers reporting spectra and weak illumination compared to outdoor light. In this study, by using two compatible 16 structures, we demonstrate a simultaneous modulation of light absorption and molecular donor polymers (PM7 and PM7 D1) with slightly-different band gaps and similar chemical packing under ambient conditions, which resulted in efficient indoor OPVs exhibiting power conversion efficiency (PCE) over 20% under 1000 lux of warm white light-emitting diode (2900 K). From morphological analysis, we infer that PM7 serves to seed nucleation of PM7 D1 in the ternary blend, templating its crystallization and alignment along the PM7 backbone. Such templating effect leads to increased domain spacing and relative degree of crystallinity (rDoC) compared to those of each binary system. We further show that higher rDoC helps suppress both bimolecular and trap-assisted recombination of photogenerated charges in the ternary devices. As a result, the complementary absorption and synergistic molecular assembly of the two donor polymers enhance the short-circuit current density as to increase the average PCEs from 9.6 to 10.3% under 1 sun and from 18.7 to 20.0% under 1000 lux. We envision that our strategy of incorporating both a planar and a flexible donor polymer with similar chemical structures can be generally applicable to attain a high performance ternary OPV under both 1 sun and indoor light.

14 SOLAR ENERGY↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗