Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overall Cooling Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Light Absorption in the Stratosphere: Trend, Soot Aerosol Concentration and Contribution by...

The light absorption coefficient, Beta(a) of the stratospheric aerosol is an important quantity that determines its radiative effects. When combined with the aerosol scattering coefficient, Beta(a) it becomes possible to evaluate the aerosol single scatter albedo, omega = Beta(s)/(Beta(s) + Beta(a)) which is essential for modeling the overall radiative effects of the stratospheric aerosol. Pollack1 determined that omega = 0.98 is a critical value that separates stratospheric cooling from warming.

Pueschel, R. F.↗

Aerosol Direct, Indirect, Semidirect, and Surface Albedo Effects from Sector Contributions Based on the IPCC AR5 Emissions for Preindustrial and Present-day Conditions

The anthropogenic increase in aerosol concentrations since preindustrial times and its net cooling effect on the atmosphere is thought to mask some of the greenhouse gas-induced warming. Although the overall effect of aerosols on solar radiation and clouds is most certainly negative, some individual forcing agents and feedbacks have positive forcing effects. Recent studies have tried to identify some of those positive forcing agents and their individual emission sectors, with the hope that mitigation policies could be developed to target those emitters. Understanding the net effect of multisource emitting sectors and the involved cloud feedbacks is very challenging, and this paper will clarify forcing and feedback effects by separating direct, indirect, semidirect and surface albedo effects due to aerosols. To this end, we apply the Goddard Institute for Space Studies climate model including detailed aerosol microphysics to examine aerosol impacts on climate by isolating single emission sector contributions as given by the Coupled Model Intercomparison Project Phase 5 (CMIP5) emission data sets developed for Intergovernmental Panel on Climate Change (IPCC) AR5. For the modeled past 150 years, using the climate model and emissions from preindustrial times to present-day, the total global annual mean aerosol radiative forcing is -0.6 W/m(exp 2), with the largest contribution from the direct effect (-0.5 W/m(exp 2)). Aerosol-induced changes on cloud cover often depends on cloud type and geographical region. The indirect (includes only the cloud albedo effect with -0.17 W/m(exp 2)) and semidirect effects (-0.10 W/m(exp 2)) can be isolated on a regional scale, and they often have opposing forcing effects, leading to overall small forcing effects on a global scale. Although the surface albedo effects from aerosols are small (0.016 W/m(exp 2)), triggered feedbacks on top of the atmosphere (TOA) radiative forcing can be 10 times larger. Our results point out that each emission sector has varying impacts by geographical region. For example, the single sector most responsible for a net positive radiative forcing is the transportation sector in the United States, agricultural burning and transportation in Europe, and the domestic emission sector in Asia. These sectors are attractive mitigation targets.

Bauer, Susanne E.↗

Radiative heating rates near the stratospheric fountain

Radiative heating rates are computed for various sets of conditions thought to be appropriate to the stratospheric fountain region: with and without a layer of cirrus cloud between 100 and 150 mbar; with standard ozone and with decreased ozone in the lower stratosphere, again with and without the cirrus cloud; and with different temperatures in the tropopause region. The presence of the cloud decreases the radiative cooling below the cloud in the upper troposphere and increases the cooling above it in the lower stratosphere. The cloud is heated at the base and cooled at the top and thus radiatively destabilized; overall it gains energy by radiation. Decreasing ozone above the cloud also tends to cool the lower stratosphere. The net effect is a tendency for vertical convergence and horizontal divergence in the cloud region. High resolution profiles of temperature, ozone, and cloudiness within the fountain region are required in order to assess the final balance of the various processes.

Doherty, G. M.↗

Gamma-Ray Spectra and Variability of Cygnus Z-1 Observed by BATSE

We present new BATSE earth occultation observations of the 25 keV-1.8 MeV spectrum and variability of Cygnus X-1 made between August 1993 and May 1994. We observed that the normal soft gamma ray spectrum (gamma2) of Cygnus X-1 has two components: a Comptonized part seen below 300 keV, and a high-energy tail in the 0.3 - 2 MeV range. We interpret it in terms of a two-layer region, consisting of a high-energy core (with an equivalent electron temperature of approximately 210-250 keV) near the event horizon, embedded in an about 50 keV corona. In this scenario, the observed 25-300 keV photons were produced by Compton scattering of soft photons (about 0.5 keV) by the hot electrons in the outer corona. These same hard x rays were further up-scattered by a population of energetic electrons in the inner core, producing the spectral tail above 300 keV. Cygnus X-1 went through an extended sequence of transitions between August 1993 and May 1994, when the 45-140 keV flux first decreased steadily from approximately gamma2 to roughly one-quarter of its intensity over a period of about 140 days. The flux remained at this low level for about 40 days before returning, swiftly (approximately 20 days) to approximately the initial gamma2 level. During the transition, the spectrum evolved to a shape consistent with either a power law with photon index of about 2.6 or a single temperature Compton model with electron temperature kT = 110 +/- 11 keV, and optical depth t = 0.40 +/- 0.06, and then returned essentially to the original gamma2 spectrum at the end of the active period. The overall cooling of the system during the low flux period may be due to an increase in the soft photon population which effectively quenched the hot electrons in these regions through Compton scattering.

Ling, J. C.↗

Hydrogen-oxygen catalytic ignition and thruster investigation. Volume 1: Catalytic ignition and low pressure thruster evaluations

An experimental and analytical program was conducted to evaluate catalytic igniter operational limits, igniter scaling criteria, and delivered performance of cooled, flightweight gaseous hydrogen-oxygen reaction control thrusters. Specific goals were to: (1) establish operating life and environmental effects for both Shell 405-ABSG and Engelhard MFSA catalysts, (2) provide generalized igniter design guidelines for high response without flashback, and (3) to determine overall performance of thrusters at chamber pressures of 15 and 300 psia (103 and 2068 kN/sq m) and thrust levels of 30 and 1500 lbf, respectively. The experimental results have demonstrated the feasibility of reliable, high response catalytic ignition and the effectiveness of ducted chamber cooling for a high performance flightweight thruster. This volume presents the results of the catalytic igniter and low pressure thruster evaluations are presented.

Johnson, R. J.↗

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

Weight trends for a fully reusable advanced single-stage Shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large earth-to-orbit transports. Some subsystems grow as the square of vehicle size, others grow as the cube of vehicle size, and still others remain nearly constant irrespective of vehicle size. The overall trend, however, is a reduction in the inerts as a percentage of gross as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. Of greatest impact on overall vehicle weight is body shape and internal packaging and could account for weight savings of up to 30 percent in body structure. Other subsystems are important but the savings are much smaller in relation to overall vehicle weight - individually less than one percent.

Macconochie, I. O.↗

Weight trends for a fully reusable advanced single-stage shuttle

The rate at which subsystem weights grow with vehicle gross weight is assessed and is shown to be critical to the efficiency of large Earth to orbit transports. The overall trend, however, is a reduction in the inerts as a percentage of gross weight as the vehicle size is increased. For this reason, the larger the vehicle, the greater the payload weight delivered per pound of vehicle manufactured. Other critical issues addressed include the effects of wing loading and wing size on wing weight, the effect of entry planform loading on thermal protection system weight, the impact of power demand on cooling system and prime power weight, and tank fineness ratio on insulation weight. The effects of body shape and various internal packaging arrangements on weight and balance are also discussed. The greatest impact on overall vehicle weight is body shape and internal packaging, and could account for weight savings of up to 30 percent in body structure. Other subsystems are important, but the savings are much smaller in relation to overall vehicle weight--individually less than one percent.

Macconochie, I. O.↗

Neutral cloud theory of the Jovian nebula: Anomalous ionization effect of superthermal electrons

The standard model of the Jovian nebula postulates that its particle source is the extended cloud of neutral sulfur and oxygen atoms that escape from the satellite Io and become ionized through electron impact from the corotating plasma. Its energy source is the gyroenergy acquired by newly formed pickup ions as they are swept up to corotation velocity by the planetary magnetic field. Elastic collisions between plasma ions and electrons cool the ions and heat the electrons, while inelastic collisions cool the electrons and excite the ions to radiate intense line emission, which is the primary energy-loss mechanism for the plasma. This neutral cloud theory of the Io plasma torus, as it has come to be known, has been the subject of recent critcism which asserts that the theory cannot account for the observed charge state of the plasma which features O(+) and S(2+) as the dominant ions. It is shown in this work that the inclusion of a small population of super-thermal electrons is required to achieve the correct ion partitioning among various charge states. It is also argued that the anomalous ionization effect of the superthermal electrons is responsible for the overall spatial bifurcation of the nebula into a hot multiply charged plasma region outside of 5.7 Jovian radii and a cool singly ionized plasma inside this distance.

Barbosa, D. D.↗

An Evaluation of Clouds and Radiation in a Large-Scale Atmospheric Model Using a Cloud Vertical Structure Classification

We revisit the concept of the cloud vertical structure (CVS) classes we have previously employed to classify the planet's cloudiness (Oreopoulos et al., 2017). The CVS classification reflects simple combinations of simultaneous cloud occurrence in the three standard layers traditionally used to separate low, middle, and high clouds and was applied to a dataset derived from active lidar and cloud radar observations. This classification is now introduced in an atmospheric global climate model, specifically a version of NASA's GEOS-5, in order to evaluate the realism of its cloudiness and of the radiative effects associated with the various CVS classes. Such classes can be defined in GEOS-5 thanks to a sub column cloud generator paired with the model's radiative transfer algorithm, and their associated radiative effects can be evaluated against observations. We find that the model produces 50% more clear skies than observations in relative terms and produces isolated high clouds that are slightly less frequent than in observations, but optically thicker, yielding excessive planetary and surface cooling. Low clouds are also brighter than in observations, but underestimates of the frequency of occurrence (by ~20% in relative terms) help restore radiative agreement with observations. Overall the model better reproduces the longwave radiative effects of the various CVS classes because cloud vertical location is substantially constrained in the CVS framework.

Lee, Dongmin↗

Distortion and Residual Stress Control in Integrally Stiffened Structure Produced by Direct Metal Deposition

2-D thermo-mechanical model developed to characterize distortion and residual stresses in integral structure produced by DMD. Demonstrated as a tool to guide experimental development of DMD fabrication process for aero structures. Distortion and residual stresses are local to deposit. Most distortion develops during deposition of the first few layers; Little change in distortion or residual stresses after fifth deposit layer Most of distortion is localized just beneath the build. Thicker build plates and the use of build lands results in greatest decrease in levels of distortion. Pre-straining shown to reduce distortion. Difficult to implement, particularly for complex stiffener arrays. Clamp position has complex effect on distortion and stresses. Overall distortion reduced with decreasing clamp clearance. Larger clamp clearances induce bending. Use of pre-heat and active cooling show minor influence on panel distortion. Generate changes in thermal gradients in the build plate.

Lin, Shih-Yung↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6% are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6%. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Analysis of Regen Cooling in Rocket Combustors

The use of detailed CFD modeling for the description of cooling in rocket chambers is discussed. The overall analysis includes a complete three-dimensional analysis of the flow in the regenerative cooling passages, conjugate heat transfer in the combustor walls, and the effects of film cooling on the inside chamber. The results in the present paper omit the effects of film cooling and include only regen cooling and the companion conjugate heat transfer. The hot combustion gases are replaced by a constant temperature wall boundary condition. Load balancing for parallel cluster computations is ensured by using single-block unstructured grids for both fluids and solids, and by using a 'multiple physical zones' to account for differences in the number of equations. Validation of the method is achieved by comparing simple two-dimensional solutions with analytical results. Representative results for cooling passages are presents showing the effects of heat conduction in the copper walls with tube aspect ratios of 1.5:l.

Harper, Brent↗

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6 percent are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6 percent. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

Effects of oxidation and roughness on Cu contact resistance from 4 to 290 K

Knowledge of the factors influencing contact resistance is important for optimizing system design in cryogenic applications. In space cryogenics, indirect cooling of infrared components is the primary concern. The presence of bolted joints results in contact resistances which can dominate all other contributions to the overall heat transfer rate. Here, thermal and electrical contact resistances measured between 4 K and 290 K for a series of bolted OFHC Cu contacts are reported. Surface roughness is found to have little effect on the overall contact resistance within the experimental limits, while oxidation can increase the contact resistance by as much as a factor of 100. Thermal and electrical contact resistances measured on the same contact show that the contact resistance temperature dependence does not follow the bulk dependence. For example, the residual resistance ratio (RRR) of the OFHC Cu is 110, but for contacts made from this material, the RRR is about two.

Nilles, M. J.↗

Standardization of Rocket Engine Pulse Time Parameters

Plumes of bipropellant thrusters are a source of contamination. Small bipropellant thrusters are often used for spacecraft attitude control and orbit correction. Such thrusters typically operate in a pulse mode, at various pulse lengths. Quantifying their contamination effects onto spacecraft external surfaces is especially important for long-term complex-geometry vehicles, e.g. International Space Station. Plume contamination tests indicated the presence of liquid phase contaminant in the form of droplets. Their origin is attributed to incomplete combustion. Most of liquid-phase contaminant is generated during the startup and shutdown (unsteady) periods of thruster pulse. These periods are relatively short (typically 10-50 ms), and the amount of contaminant is determined by the thruster design (propellant valve response, combustion chamber size, thruster mass flow rate, film cooling percentage, dribble volume, etc.) and combustion process organization. Steady-state period of pulse is characterized by much lower contamination rates, but may be lengthy enough to significantly conh'ibute to the overall contamination effect. Because there was no standard methodology for thruster pulse time division, plume contamination tests were conducted at various pulse durations, and their results do not allow quantifying contaminant amounts from each portion of the pulse. At present, the ISS plume contamination model uses an assumption that all thrusters operate in a pulse mode with the pulse length being 100 ms. This assumption may lead to a large difference between the actual amounts of contaminant produced by the thruster and the model predictions. This paper suggests a way to standardize thruster startup and shutdown period definitions, and shows the usefulness of this approach to better quantify thruster plume contamination. Use of the suggested thruster pulse time-division technique will ensure methodological consistency of future thruster plume contamination test programs, and allow accounting for thruster pulse length when modeling plume contamination and erosion effects.

Larin, Max E.↗

TPSAS-NF1676L-36113-DND

Concerns about the effects of extreme heat and poor air quality are increasing in North America’s largest urban centers. In Philadelphia, environmental and public health groups are concerned about how these phenomena disproportionality affect marginalized communities and populations, which often have extensive impervious surfaces and little access to green space. In order to address these concerns, the Philadelphia Department of Public Health and the Office of Sustainability seek to effectively prioritize cooling initiatives to reduce urban heat and decrease air pollutants. We evaluated land surface temperature (LST) and the Normalized Difference Vegetation Index (NDVI), as a measure of overall greenness, obtained from NASA Earth observations Aqua and Terra Moderate Resolution Imaging Spectroradiometer (MODIS), and the Ecosystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). These analyses we recombined with local tree inventory, air quality, and socioeconomic data through a multivariate analysis to identify areas where new trees or cooling adaptations are most needed. The results and data of this project can be used by our partners to inform both short-term heat relief planning and a long-term, multi-agency heat response.

Spencer Nelson↗

A 12,000-year record of vertical deformation across the Yellowstone caldera margin: The shorelines of Yellowstone Lake

The 600 ka Yellowstone caldera exhibits several signs of unrest, the most evident of which is historic ground deformation including both uplift and subsidence. We document deformation in the area of the southern caldera across approximately 12,000 years using the postglactic shoreline terraces of Yellowstone Lake. Raised shoreline elevations were interpreted from 230 leveling profiles surveyed across flights of terraces, with an accuracy of +/- 0.5 m. Of about 11 recognizable terraces, the five most continuous raised shorelines were correlated around the lake basin to reveal deformation patterns. Net deformation over the past approximatley 3 kyr has been dominantly up within the caldera interior and slightly down along the caldera rim, relative to the extracaldera region. This uplift is roughly similar to the historic pattern and may largely represent the effects of the most recent inflation episode. Subtraction of the total estimated magnitude of inflation in this epsiode suggests that the overall trend of postglacial deformation has been subsidence. The cause of this trend is undetermined but is most likely related to the effects of regional extension and long-term cooling within the Yellowstone caldera.

Locke, William W.↗