Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overall Cooling Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Thermal Management for a Novel Non-Heavy Rare-Earth Interior Permanent Magnet Machine

The work presents a thermal management solution for a novel non-heavy rare-earth permanent magnet machine being developed at Oak Ridge National Laboratory. The motor has been designed to minimize losses while maximizing performance for a range of speeds and power ratings. The novel motor design reduces rare-earth magnet usage, thereby avoiding supply chain issues. The motor component heat losses are established for operating windows and desired performance. These heat losses, along with windage losses, are being used to develop cooling solutions for different components of this machine. A novel thermal management solution for stators and rotors has been developed, and progress is presented in this paper. The stator cooling is achieved with the help of water-ethylene glycol flowing over the finned aluminum stator jacket, and rotor cooling with automatic transmission fluid passing through novel channels designed in the rotor laminations. The attempt is to establish effective cooling of the stator winding, laminations, and rotor magnets. A 3D conjugate heat transfer model has been developed for overall thermal analysis to establish a down- selected thermal management solution for the machine. The model, in addition to estimated component heat losses, includes windage losses and its impact on rotor and stator cooling. Overall, the work presents a workable thermal solution for the interior permanent magnet machine with potential for further improvements. Future work will involve establishing end winding and refinement of other end parts of the machine with the aim of establishing a robust thermal management solution. The work will also focus on different shapes (e.g., round, non-round, presence of wedges) of rotor-stator gaps and investigate windage losses and their impact on thermal management for higher rotational speeds for the machine.

30 DIRECT ENERGY CONVERSION↗

Cosmic Reionization on Computers: Baryonic Effects on Halo Concentrations during the Epoch of Reionization

Baryons both increase halo concentration through adiabatic contraction and expel mass through feedback processes. However, it is not well understood how the radiation fields prevalent during the epoch of reionization affect the evolution of concentration in dark matter halos. We investigate how baryonic physics during the epoch of reionization modify the structure of dark matter halos in the Cosmic Reionization On Computers (CROC) simulations. We use two different measures of halo concentration to quantify the effects. We compare concentrations of halos matched between full-physics simulations and dark-matter-only simulations with identical initial conditions between 5 ≤ z ≤ 9. Baryons in full-physics simulations do pull matter toward the center, increasing the maximum circular velocity compared to dark-matter-only simulations. However, their overall effects are much less than if all the baryons were simply centrally concentrated indicating that heating processes efficiently counteract cooling effects. Finally, we show that the baryonic effects on halo concentrations at z ≈ 5 are relatively insensitive to environmental variations of reionization history. These results are pertinent to models of galaxy–halo connection during the epoch of reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot Carrier Redistribution, Electron-Phonon Interaction, and Their Role in Carrier Relaxation in Thin Film Metal-Halide Perovskites

Temperature dependent (4–295 K) photoluminescence and transmission spectra are analyzed to study the effect of changing the different components of a perovskite compound, be it A, B, or X. Four different films are compared: FAMAPbSnI3, FAPbI3, FAMAPbI3, and FAPbBr3. The low temperature results highlight the changes that occur, especially underlying ones that are easily masked at room temperature. The overall Stokes shift is of similar magnitude at room temperature for the three Pb only based samples. This is governed by the interaction strength GLO, phonon energy ELO, and exciton binding energy Eex. One exception to this behavior is the Sn based FAMAPbSnI3 film, which shows a lack of Stokes shift between the absorption and photoluminescence. However, the strong absorption (more than 100 meV) below the band gap is indicative of an excitonic feature that has a large density of states. Transient absorption measurements confirm the trends observed in continuous wave (CW) measurements; the three Pb only films all show the convolution of an excitonic feature within 20 meV of the band gap as a contributing factor to the photobleach along with a region of high energy photoinduced absorption (PIA). However, the behavior for the Sn based film is notably different (just as it is in the CW measurements) with an unusual low energy PIA and a lack of high energy PIA. The large unusual low energy PIA is attributed to the large sub-band-gap absorption observed in the CW transmission/absorption measurements. Notably, regardless of interchanging components, the slow cooling of carriers in metal-halide perovskites shows little effect of GLO, ELO, and Eex. As such, here it is proposed that while the initial cooling of carriers is attributed to LO phonons, the overall cooling of carriers is dominated by the intrinsic low thermal conductivity of all metal-halide perovskites, which limits the dissipation of acoustic phonons in these systems

2D perovskites↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Enhancement of Thermal Conductivity of Bentonite Buffer Materials with Copper Wires/Meshes for High-Level Radioactive Waste Disposal

In high-level radioactive waste disposal, a heat-generating waste canister is generally encased with a layer of bentonite-based buffer material acting as an engineered barrier to limit water percolation and radionuclide release. The low thermal conductivity of bentonite (~0.5 W/m∙K) combined with a high thermal loading waste package may result in a high surface temperature on the package that can potentially impact the structural integrity of the package itself as well as the surrounding buffer material. We show in this paper that the thermal conductivity of bentonite can be effectively enhanced by embedding copper wires/meshes across the buffer layer to form fully connected high heat conduction pathways. A simple calculation based on Rayleigh’s model shows that a required thermal conductivity of 5 W/m∙K for effective heat dissipation can be achieved simply by adding ~1 vol % of copper wires/meshes into bentonite. As a result, the peak surface temperature on a large waste package such as a dual-purpose canister can be reduced by up to 300°C, leading to a significant reduction in the surface storage time for waste cooling and therefore the overall cost for direct disposal of such waste packages. Because of the ensured full thermal percolation across the buffer layer, copper wires/meshes turn out to be much more effective than any other materials currently suggested (such as graphene or graphite) in enhancing the thermal conductivity of buffer material. Furthermore, the embedded copper wires/meshes can help reinforce the mechanical strength of the buffer material, thus preventing the material from a potential erosion by a possible intrusion of dilute groundwater.

36 MATERIALS SCIENCE↗

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Hot-tail electrons’ impact on assimilation and injection penetration of D2 shattered pellet injections

The assimilation and the penetration of injected materials play significant roles in the mitigation efficiency of shattered pellet injection (SPI) as a disruption mitigation system (DMS), hence an accurate description of the fragment ablation rate is desirable. Current mainstream 3D MHD codes modelling SPIs mostly assume instantaneous thermalization between the previously hot ambient electrons and the newly released cold electrons. This could result in underestimation of the ablation rate if the hot electron thermalization time is comparable or even longer than the fragment flying time across flux tubes, putting the validity of these 3D SPI simulations into question. To resolve this doubt, we, in this study, investigate the thermalization dynamics and the overall hot-electron impact. The finite-time collisional thermalization of hot-tail electrons in a rapidly cooling plasma, as well as the so-called ‘self-limiting’ effect are considered. The former effect tends to deplete the colder population within a hot-tail species, while the latter is found to preferentially deplete the higher energy population. The combined result is found to cause an almost self-similar decay of the hot electron distribution function, while its shape does not deviate much from that of Maxwellian distribution and the mean energy does not change much during the thermalization process. Based on this observation, axisymmetric JOREK D2 SPI simulations were carried out with additional hot-tail contribution to evaluate their overall impact onto the injection assimilation and penetration. It is found that the hot-tail effect indeed causes enhanced assimilation and shallower penetration, although the overall effect depends on the exact injection configuration, with the slow injection showing negligible hot-tail effect while the fast single non-shattered pellet case shows drastic hot-tail ablation enhancement. For ITER-like SPI parameters, there is no significant deviation in the total assimilation, but some deviation in the injection penetration is observed for the fast injection velocity cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Topological Hall Effect in Antiferromagnetic Co-Doped Fe 3 GaTe 2

Fe 3 GaTe 2 is van der Waals (vdW) ferromagnet with a Curie temperature T C ranging from 350 K to 380 K, followed upon cooling by a ferrimagnetic transition near room temperature. Substituting Fe with Co was previously reported to induce antiferromagnetism (AFM) at a Co fraction dependent Néel temperature TN. In this work, we confirm the overall phase diagram of the Fe 3-x Co x GaTe 2 series as a function of x and temperature via magnetization and electrical transport measurements. For x ≥ 0.6 the Hall effect is observed to mimic the magnetization as the AF ground state is suppressed by the external magnetic field via a metamagnetic transition, thus displaying an anomalous Hall response. At low temperatures, we also observe a pronounced topological Hall signal peaking at μ 0 H = 4 T, or within the metamagnetic transition region of fields. This observation points to the presence of magnetic field-induced chiral spin textures, such as skyrmions upon approaching magnetization saturation. Remarkably, magnetic force microscopy (MFM) reveals the emergence of nearly circular magnetic domains, with diameters on the order of 100–200 nm, within the antiferromagnetic phase. Here, a detailed analysis of the MFM images indicates that the topological Hall effect is closely linked to the field-induced stabilization of magnetic domain structures, likely exhibiting chiral textures. This observation suggests the possible formation of skyrmions already in the AFM phase, i.e., AFM skyrmions, that evolve into ferromagnetic (FM) ones upon increasing the magnetic field. Consequently, Co-doped Fe 3 GaTe 2 might provide a platform to investigate the transformation of skyrmions, initially coupled antiferromagnetically into ferromagnetic skyrmions, and to explore its impact on the topological and skyrmion Hall effects.

anomalous Hall effect↗

Thermoeconomic cost optimization of superconducting magnets for proton therapy gantries

A compact gantry delivering 70-220 MeV protons with fixed field in the superconducting magnets could reduce the cost and improve the adoption of proton therapy. While a number of magnet and cryogenics designs have been proposed, the combined capital and operating costs of state-of-the-art superconducting materials have not been analyzed. In response, we develop a thermoeconomic model of a multi-stage, conduction cooled gantry lattice and analyze the cryocooler operating cost, cryocooler capital cost and conductor capital cost for Nb-Ti, Nb 3 Sn, REBCO and Bi-2223 over a continuous range of magnet temperatures, and a differential evolution algorithm is used to identify the optimal combination of thermal intercept temperatures. Although Nb3Sn yields the lowest Net Present Value (NPV) of $111.7k at a magnet temperature of 9.4 K, the optimized Bi-2223 design at 12.8 K approaches the realm of commercial feasibility by offering improved thermal stability and forgoing the need for costly conductor heat treatment and magnet quench training. Furthermore, it was found that Nb3Sn was more cost effective than Nb-Ti and that REBCO was not economically viable for the parameters of this investigation. Overall, the thermoeconomic model developed herein can optimize conductor choices, magnet temperatures and thermal staging which has value for any conduction-cooled superconducting magnet.

BSCCO↗

Harvest and nitrogen effects on bioenergy feedstock quality of grass-legume mixtures on Conservation Reserve Program grasslands

Perennial grass mixtures established on Conservation Reserve Program (CRP) lands can be an important source of feedstock for bioenergy production. This study aimed to evaluate management practices for optimizing the quality of bioenergy feedstock and stand persistence of grass-legume mixtures under diverse environments. A 5-year field study (2008–2012) was conducted to assess the effects of two harvest timings (at anthesis vs after complete senescence) and three nitrogen (N) rates (0, 56, 112 kg N ha -1 ) on biomass chemical compositions (i.e., cell wall components, ash, volatiles, total carbon, and N contents) and the feedstock energy potential, examined by the theoretical ethanol yield (TEY) and the total TEY (i.e., the product of biomass yield and TEY, L ha -1 ), of cool-season mixtures in Georgia and Missouri and a warm-season mixture in Kansas. The canonical correlation analysis (CCA) was used to investigate the effect of vegetative species transitions on feedstock quality. Although environmental variations (mainly precipitation) greatly influenced the management effect on chemical compositions, the delayed harvest after senescence generally improved feedstock quality. In particular, the overall cell wall concentrations and TEY of the warm-season mixtures increased by approximately 7%. Additional N supplies improved the total TEY of both mixtures by ~1.6–4.2 L ha -1 per 1.0 kg N ha -1 input but likely lowered the feedstock quality, particularly for the cool-season mixture. The cell wall concentrations of cool-season mixture reduced by approximately 3%–6%. The CCA results indicated that the increased legume compositions (under low N input) likely enhanced lignin but reduced ash concentrations. This field research demonstrated that with proper management, grass-legume mixtures on CRP lands can provide high-quality feedstock for bioenergy productions.

09 BIOMASS FUELS↗

The importance of accounting for the Tolman correction to surface tension for nucleation and growth modeling of Fe clusters

Gibbs free energies of clusters are required for predictive modeling of cluster growth during condensation of a cooling vapor. Here, we present a straightforward method of calculating free energies of cluster formation using the data from molecular dynamics (MD) simulations. We apply this method to iron clusters having from 2 to 100 atoms. The energies obtained are verified by comparing to an MD-simulated equilibrium cluster size distribution in a sub-saturated vapor. We show that these free energies differ significantly from those obtained with a commonly used spherical cluster approximation, which relies on a surface tension coefficient of a flat surface, as it is used in the classical nucleation theory (CNT). We show that the spherical cluster approximation in CNT can be improved by using a cluster-size-dependent Tolman correction for the surface tension. The Tolman length and effective surface tension values were derived for iron clusters, and they significantly differ from the commonly used experimentally measured values. This improved approximation does not account for geometric magic number effects responsible for spikes and troughs in densities of neighbor cluster sizes. Nonetheless, it allows to more accurately model cluster formation from a cooling vapor. It better reproduces the condensation timeline, overall shape of the cluster size distribution, average cluster size, and the distribution width. In contrast, using a constant surface tension coefficient (as done in CNT) resulted in incorrect condensation dynamics and cluster size distributions. The analytical expression for cluster nucleation rate from CNT was updated to account for the size-dependence of cluster surface tension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Concurrent Cooling Effects of Dynamic Line Ratings on Wind Plant Gen-Tie Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a series of gen tie lines connecting wind plants to the regional transmission lines. This consists of two primary study regions, the first on the desert west of Idaho Falls, and the second in the region east of the Cascades along the Columbia River Gorge. The TREAD program that was developed at INL was used to create generated gen-tie lines based on nearby regional transmission line connections. The capacity availability of the gen tie lines are compared with the power production of the wind farms. Overall, the INL Site location shows a much greater capacity for the gen-tie lines due to the higher wind speeds. Across both locations, the HRRR data shows higher wind speeds than observed at the observational weather stations. For both the Columbia Gorge and Idaho areas, the sites show that a statically rate gen-tie could carry additional capacity far above the rated during periods of high wind due to the concurrent cooling effects.

17 WIND ENERGY↗