Search NASA⌕ Search

SEARCH · Search NASA

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Reflectance spectra measurement plan of captured samples from Ryugu: current status

Hayabusa2 spacecraft is equipped with Optical Navigation Camera (ONC) andNear-infrared Spectrometer (NIRS3), and has obtained reflectance spectra of the C-type near-Earth asteroid Ryugu over a wavelength range of 0.40–0.95 μm and 1.8–3.2 μm, respectively. It was revealed that Ryugu exhibits globally very low albedo (less than 0.02 at 0.55 and 2.0 μm), a slightly positive spectral slope, and an ubiquitous weak but sharp OH absorption band centered at 2.72 μm,showing a little regional heterogeneities. Thus, the surface material of Ryugu can be estimated as relatively similar to moderately heated carbonaceous chondrites, e.g., moderately dehydrated CI and CM, and enriched in carbon (Kitazato et al., 2019; Sugita et al., 2019; Tatsumi et al., 2020).Hayabusa2 successfully has performed twice touch down operations, and the captured sample will be brought back to the Earth in late 2020 (Morota et al., 2020; Tachibana et al., in preparation). To clarify Ryugu’s mineralogical and physicochemical properties and their varieties, effective for spectral characteristics obtained by ONC and NIRS3, several grains are planned to be distributed to several primary analysis groups. In this study, we report the current status of our spectral analysis plan in Hayabusa2 MINeralogy and PETrology of coarse grains (MIN-PET CG) team led by T. Nakamura, and the latest rehearsal analysis result using carbonaceous chondrite samples. MIN-PET CG rehearsal measurements have been performed to obtain detailed spectral properties of Ryugu grains with diverse spatial resolutions ranging from μm to mm scale or larger; using a few mm size polished CM sample with several microscopic imaging spectrometers covering various spatial range; with 200 μmor finer spatial resolution at Institut d’Astrophysique Spatiale, ~50 and 150 μm spatial resolution invisible and IR ranges at Brown University, and with 40 μm or larger spatial resolution at Tohoku University, and using mm-size CM and CI grains with a diffuse reflectance spectrometer with a few mm resolution at Tohoku University. Diffuse reflectance spectroscopy measurements undergo to use several mm-size CM or CI chondrite grains with Bruker VERTEX 70v, which covers ~0.38–15 μm in wavelength. To keep returned samples out of atmosphere avoiding any terrestrial contamination, wehave prepared an air shutoff cell to put samples and standard materials together kept in a N2 purged condition (Amano et al., 2020). Samples are Murchison CM chondrite showing typically ~5%reflectance with a strong OH absorption band at ~2.8 μm, and laboratory heated CI chondrite showing~3% reflectance, and a weak OH absorption band at ~2.7 μm. We will perform (1) fixed angle condition as laboratory standard setting at incident, emission, and phase angles of 30°, 0°, 30°, or 0°,30°, 30°, and (2) various angle conditions for photometric corrections. Future lab analyses of samples returned from Ryugu will provide direct and detailed information on the mineralogical and physicochemical properties of Ryugu, and relationship of spectral characteristics obtained by remote sensing and laboratory instruments.

M. Matsuoka↗

Electron spin resonance of gamma-irradiated poly/ethylene 2,6-naphthalene dicarboxylate/.

The two types of radicals trapped in gamma-irradiated PEN 2,6 are identified by ESR as - O - CH - CH2 - O - (radical I) and a radical located on the naphthalene ring (radical II). The concentrations of the radicals in the gross polyer are 10 to 20% of I and 80 to 90% of II. Similar trapped radicals are established in beta-irradiated PET, a structurally related polymer.

Rogowski, R. S.↗

Appendix A: Specimen 72275 documentation

The friability of the matrix of specimen 72275 caused numerous fragments and an abundance of fines to break away from the main mass during transport from the moon and handling in the lunar receiving laboratory. Samples 72275,1 to 72275,14 were labeled during PET examination. Samples 72275,1, 4, 6, 7, 8, and 9 were placed in storage, and the remainder were distributed.

Marvin, U. B.↗

X-ray evaluation of crystals for stellar spectrometers

The report consists of three parts. The first part is an analysis of the principles involved in X-ray crystal evaluation and how they are applied to a number of crystals. The principles of crystal evaluation analysis as they apply to the special problems of X-ray astronomy are presented. A number of crystals were evaluated, and the energy dependence of the diffraction properties of (002) PET, (111) Ge, (101) ADP, (001) KAP, and (001) RAP are reported. The second part is a compilation of the diffraction properties of a number of crystals as reported by other authors. In the third part some technical details of a triple crystal spectrometer built by the author at Polytechnic Institute of Brooklyn are given. This spectrometer seems to be a most appropriate instrument for evaluation of crystal properties. (Modified author abstract)

Alexandropolos, N. G.↗

Crystals for stellar spectrometers

Crystal evaluation as it applies to instrumentation employed in X-ray astronomy is reviewed, and some solutions are offered to problems that are commonly encountered. A general approach for selecting the most appropriate crystals for a given problem is also suggested. The energy dependence of the diffraction properties of (002) PET, (111) Ge, (101) ADP, (101) KAP, and (001) RAP are reported.

Alexandropoulos, N. G.↗

The Hard X-ray experiment on the Astronomical Netherlands Satellite

The Hard X-ray Experiment flown on the Astronomical Netherlands Satellite is described. The instrument consists of two parts. One is a large-area detector of about 60 sq cm in total area, sensitive in the energy range between 1.5 and 30 keV. Two counters comprise this detector, each collimated 10 min by 3 deg and offset in the narrow direction by 4 min. The other part is a Bragg-crystal assembly consisting of two PET crystals and counters aligned to search for the silicon emission lines near 2 keV. Instrument characteristics and orbital operations are described.

Gursky, H.↗

Time development of a small solar X-ray burst

The 5.1-7.2 A X-ray emission from the sun was studied via OSO-8 with a high-resolution PET crystal spectrometer during the week of 17 November 1975, when the sun was active. The combination of good temporal and spectral resolution permitted the analysis of the data with multithermal coronal models over the course of a small X-ray burst.

Cohen, G. G.↗

Crystals for astronomical X-ray spectroscopy

Crystal spectrometric properties and the factors that affect their measurement are discussed. Theoretical and experimental results on KAP are summarized and theoretical results based on the dynamical theory of X-ray diffraction are given for the acid phthalates as well as for the commonly used planes of ADP, PET and EDDT. Anomalous dispersion is found to be important for understanding the details of crystal Bragg reflection properties at long X-ray wavelengths and some important effects are pointed out. The theory of anomalous dispersion is applied to explain the anomalous reflectivity exhibited by KAP at 23.3 A.

Burek, A.↗

Utilization of NASA Lewis mobile terminals for the Hermes satellite

The high power of the Hermes satellite enables two-way television and voice communication with small ground terminals. The Portable Earth Terminal (PET) and the Transportable Earth Terminal (TET) were developed and built by NASA-Lewis to provide communications capability to short-term users. The NASA-Lewis mobile terminals are described in terms of vehicles and onboard equipment, as well as operation aspects, including use in the field. The section on demonstrations divides the uses into categories of medicine, education, technology and government. Applications of special interest within each category are briefly described.

Edelman, E. A.↗

Evaluation of verification and testing tools for FORTRAN programs

Two automated software verification and testing systems were developed for use in the analysis of computer programs. An evaluation of the static analyzer DAVE and the dynamic analyzer PET, which are used in the analysis of FORTRAN programs on Control Data (CDC) computers, are described. Both systems were found to be effective and complementary, and are recommended for use in testing FORTRAN programs.

Smith, K. A.↗

Primary propulsion of electrothermal, ion and chemical systems for space-based radar orbit transfer

An orbit transfer mission concept has been studied for a Space-Based Radar (SBR) where 40 kW required for radar operation is assumed available for orbit transfer propulsion. Arcjet, pulsed electrothermal (PET), ion, and storable chemical systems are considered for the primary propulsion. Transferring two SBR per shuttle flight to 1112 km/60 deg using electrical propulsion systems offers an increased payload at the expense of increased trip time, up to 2000 kg each, which may be critical for survivability. Trade offs between payload mass, transfer time, launch site, inclination, and height of parking orbits are presented.

Wang, S. Y.↗

Primary propulsion of electrothermal, ion, and chemical systems for space-based radar orbit transfer

An orbit transfer mission concept has been studied for a Space-Based Radar (SBR) where 40 kW required for radar operation is assumed available for orbit transfer propulsion. Arcjet, pulsed electrothermal (PET), ion, and storable chemical systems are considered for the primary propulsion. Transferring two SBR per shuttle flight to 1112 km/60 deg using eiectrical propulsion systems offers an increased payload at the expense of increased trip time, up to 2000 kg each, which may be critical for survivability. Trade offs between payload mass, transfer time, launch site, inclination, and height of parking orbits are presented.

Wang, S.-Y.↗

Investigation of a repetitive pulsed electrothermal thruster

A pulsed electrothermal (PET) thruster with 1000:1 ratio nozzle is tested in a repetitive mode on water propellant. The thruster is driven by a 60J pulse forming network at repetition rates up to 10 Hz (600W). The pulse forming network has a .31 ohm impedance, well matched to the capillary discharge resistance of .40 ohm, and is directly coupled to the thruster electrodes without a switch. The discharge is initiated by high voltage breakdown, typically at 2500V, through the water vapor in the interelectrode gap. Water is injected as a jet through a .37 mm orifice on the thruster axis. Thruster voltage, current and impulse bit are recorded for several seconds at various power supply currents. Thruster to power ratio is typically T/P = .07 N/kW. Tank background pressure precludes direct measurement of exhaust velocity which is inferred from calculated pressure and temperature in the discharge to be about 14 km/sec. Efficiency, based on this velocity and measured T/P is .54 + or - .07. Thruster ablation is zero at the throat and becomes measurable further upstream, indicating that radiative ablation is occurring late in the pulse.

Burton, R. L.↗

X-ray rocking curve measurements of bent crystals

A three-crystal laboratory X-ray spectrometer is used to measure the Bragg reflection from concave cylindrically curved crystals to be used in the high-resolution X-ray spectrometer of the NASA Advanced X-ray Astrophysics Facility (AXAF). The first two crystals, in the dispersive (1.1) arrangement, select a narrow collimated monochromatic beam in the Cu K-alpha(1) line at 1.5 A (8.1 keV), which illuminates the test crystal. The angular centroids of rocking curves measured along the surface provide a measure of the conformity of the crystal to the desired radius of curvature. Individual and combined rocking-curve widths and areas provide a measure of the resolution and efficiency at 1.54 A. The crystals analyzed included LiF(200), PET, and acid phthalates such as TAP.

Hakim, M. B.↗

Effects on respiratory homeostasis of prolonged, continuous hyperoxia at 1.5 to 3.0 ATA in man in Predictive Studies V

Prolonged exposures of men to continuous hyperoxia at 3.0, 2.5, 2.0, and 1.5 ATA were conducted to define CNS oxygen tolerance and to investigate the effects of prolonged hyperoxia on CNS and other organ functions. Altered respiratory homeostasis was evident during exposures of men to 2.5 and 3.0 ATA O2 as nonprogressive increment in ventilation and reciprocal decrement in PET(CO2). These changes were progressive during exposure at 1.5 ATA O2. Mean values of respiratory reactivity at CO2 were somewhat increased following prolonged hyperoxia at 1.5 and 2.5 ATA, compared to preexposure mean values. Hypoxic ventilatory response was unchanged or enhanced after oxygen exposures at 1.5 and 2.5 ATA. Observed respiratory and body temperature changes were not of sufficient magnitude to impair function.

Gelfand, R.↗

Friction and wear of TPS fibers: A study of the adhesion and friction of high modulus fibers

The adhesional and frictional forces between filaments in a woven fabric or felt, strongly influenced the processability of the fiber and the mechanical durability of the final product. Even though the contact loads between fibers are low, the area of contact is extremely small giving rise to very high stresses; principally shear stresses. One consequence of these strong adhesional and frictional forces is the resistance of fibers to slide past each other during weaving or when processed into nonwoven mats or felts. Furthermore, the interfiber frictional forces may cause surface damage and thereby reduce the fiber strength. Once formed into fabrics, flexural handling and manipulation of the material again causes individual filaments to rub against each other resulting in modulus, brittle fibers such as those used in thermal protection systems (TPS). The adhesion and friction of organic fibers, notably polyethylene terephthalate (PET) fibers, have been extensively studied, but there has been very little work reported on high modulus inorganic fibers. An extensive study was made of the adhesion and friction of flame drawn silica fibers in order to develop experimental techniques and a scientific basis for data interpretation. Subsequently, these methods were applied to fibers of interest in TPS materials.

Bascom, Willard D.↗

Applications of the Strategic Defense Initiative's compact accelerators

The Strategic Defense Initiative's (SDI) investment in particle accelerator technology for its directed energy weapons program has produced breakthroughs in the size and power of new accelerators. These accelerators, in turn, have produced spinoffs in several areas: the radio frequency quadrupole linear accelerator (RFQ linac) was recently incorporated into the design of a cancer therapy unit at the Loma Linda University Medical Center, an SDI-sponsored compact induction linear accelerator may replace Cobalt-60 radiation and hazardous ethylene-oxide as a method for sterilizing medical products, and other SDIO-funded accelerators may be used to produce the radioactive isotopes oxygen-15, nitrogen-13, carbon-11, and fluorine-18 for positron emission tomography (PET). Other applications of these accelerators include bomb detection, non-destructive inspection, decomposing toxic substances in contaminated ground water, and eliminating nuclear waste.

Montanarelli, Nick↗

Diurnal water relations of walnut trees - Implications for remote sensing

Leaflet water content (WC), relative water content (RWC), and water potential, Phi(lf) were measured as indicators of diurnal change in tree water status in an experimental walnut orchard receiving two irrigation treatments: 100 and 33 percent of potential evapotranspiration (PET). Diurnal change was greatest in Phi(lf) throughout the experimental period, with minima occurring each day in early to mid-afternoon and maxima between midnight and sunrise. Leaflet WC and RWC were lower in the afternoon than at night, but had greater variability so that the diurnal pattern was not as clear. Comparison between the pattern of Phi(lf) and dielectric constants (DCs) measured from probes inserted 2 cm into a tree hole showed that both declined nearly in parallel in the morning. Phi(lf) recovered more rapidly than DC in the afternoon. This temporal discrepancy could be caused by cavitation of xylem elements in the vicinity of the DC probe. Microwave backscatter for L- and X-bands also measured diurnal variation that had local minima in the afternoon, but the pattern among wavelength and polarization signatures was complex.

Weber, James A.↗