Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DEVIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Fe XXV temperatures in flares from the Yohkoh Bragg crystal spectrometer

Studies by Doschek et al. using P78-1 and Solar Maximum Misson (SMM) data have shown that the ratio of intensities of the Fe XXV and Ca XIX resonance lines can be expressed as a function of Fe XXV temperature. Using a more recent data set consisting of 13 flares observed by the Bragg crystal spectrometer (BCS) experiment on board Yohkoh, we find a nearly identical functional relationship between the same resonance line ratios and Fe XXV temperatures. We use this functional relationship to obtain resonance line ratio temperatures (T(sub RLR)) for each flare in our data set, and compare them with temperatures resulting from application of a simple spectral fitting method. (T(sub SSF)) to individal Fe XXV spectra. We also use a more involved free-parameter spectral fitting method to deduce temperatures (T(sub FSF)) from some of these spectra. On average, agreement between T(sub RLR) and T(sub SSF) improves as a flare progresses in time, with average agreements of 10.0% +/- 5.2%, 6.4% +/- 5.4%, and 5.0% +/- 3.9% over the rise, peak, and decay phases, respectively. Deviations between T(sub RLR) and T(sub FSF) are about the same or smaller. Thus, for most analysis purposes, all three methods yield virtually identical temperatures in flares. The somewhat poorer agreement between T(sub SSF) and T(sub RLR) during the earlier phases may be partially a result of difficulties in obtaining precise values for temperatures from spectral fits when blueshifts and large nonthermal broadenings are present in the spectra. Because of the high sensitivity of the Yohkoh BCS compared to that of BCS experiments on earlier spacecraft, we can for the first time consistently observe the heating phase of flares in Fe XXV.

Sterling, Alphonse C.↗

The Deep Space Network stability analyzer

A stability analyzer for testing NASA Deep Space Network installations during flight radio science experiments is described. The stability analyzer provides realtime measurements of signal properties of general experimental interest: power, phase, and amplitude spectra; Allan deviation; and time series of amplitude, phase shift, and differential phase shift. Input ports are provided for up to four 100 MHz frequency standards and eight baseband analog (greater than 100 kHz bandwidth) signals. Test results indicate the following upper bounds to noise floors when operating on 100 MHz signals: -145 dBc/Hz for phase noise spectrum further than 200 Hz from carrier, 2.5 x 10(exp -15) (tau =1 second) and 1.5 x 10(exp -17) (tau =1000 seconds) for Allan deviation, and 1 x 10(exp -4) degrees for 1-second averages of phase deviation. Four copies of the stability analyzer have been produced, plus one transportable unit for use at non-NASA observatories.

Breidenthal, Julian C.↗

Detection of reflector surface from near field phase measurements

The deviation of a reflector antenna surface from a perfect parabolic shape causes degradation of the performance of the antenna. The problem of determining the shape of the reflector surface in a reflector antenna using near field phase measurements is not a new one. A recent issue of the IEEE tansactions on Antennas and Propagation (June 1988) contained numerous descriptions of the use of these measurements: holographic reconstruction or inverse Fourier transform. Holographic reconstruction makes use of measurement of the far field of the reflector and then applies the Fourier transform relationship between the far field and the current distribution on the reflector surface. Inverse Fourier transformation uses the phase measurements to determine the far field pattern using the method of Kerns. After the far field pattern is established, an inverse Fourier transform is used to determine the phases in a plane between the reflector surface and the plane in which the near field measurements were taken. These calculations are time consuming since they involve a relatively large number of operations. A much faster method can be used to determine the position of the reflector. This method makes use of simple geometric optics to determine the path length of the ray from the feed to the reflector and from the reflector to the measurement point. For small physical objects and low frequencies, diffraction effects have a major effect on the error, and the algorithm provides incorrect results. It is believed that the effect is less noticeable for large distortions such as antenna warping, and more noticeable for small, localized distortions such as bumps and depressions such as might be caused by impact damage.

Ida, Nathan↗

Ku band low noise parametric amplifier

A low noise, K sub u-band, parametric amplifier (paramp) was developed. The unit is a spacecraft-qualifiable, prototype, parametric amplifier for eventual application in the shuttle orbiter. The amplifier was required to have a noise temperature of less than 150 K. A noise temperature of less than 120 K at a gain level of 17 db was achieved. A 3-db bandwidth in excess of 350 MHz was attained, while deviation from phase linearity of about + or - 1 degree over 50 MHz was achieved. The paramp operates within specification over an ambient temperature range of -5 C to +50 C. The performance requirements and the operation of the K sub u-band parametric amplifier system are described. The final test results are also given.

Source record↗

Analysis of a first order phase locked loop in the presence of Gaussian noise

A first-order digital phase locked loop is analyzed by application of a Markov chain model. Steady state loop error probabilities, phase standard deviation, and mean loop transient times are determined for various input signal to noise ratios. Results for direct loop simulation are presented for comparison.

Blasche, P. R.↗

Radio-science performance analysis software

The Radio Science Systems Group (RSSG) provides various support functions for several flight project radio-science teams. Among these support functions are uplink and sequence planning, real-time operations monitoring and support, data validation, archiving and distribution functions, and data processing and analysis. This article describes the support functions that encompass radio-science data performance analysis. The primary tool used by the RSSG to fulfill this support function is the STBLTY program set. STBLTY is used to reconstruct observable frequencies and calculate model frequencies, frequency residuals, frequency stability in terms of Allan deviation, reconstructed phase, frequency and phase power spectral density, and frequency drift rates. In the case of one-way data, using an ultrastable oscillator (USO) as a frequency reference, the program set computes the spacecraft transmitted frequency and maintains a database containing the in-flight history of the USO measurements. The program set also produces graphical displays. Some examples and discussions on operating the program set on Galileo and Ulysses data will be presented.

Morabito, D. D.↗

Ultra-stable oscillators for planetary entry probes

This paper presents the development of ultra-stable oscillators on deep space missions and selecting oscillators for planetary entry probes, including factors such as duration of the experiment, the available warm-up time and the Allan deviation and phase noise requirements.

ultra↗

Recent Improvements in the Beam Capture at Fermilab Booster for High Intensity Operation

The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by using its paraphase system. At the end of the capture the feedback is turned on for beam acceleration. It is vital for present operations as well as during the PIP-II era that both the HLRF and LLRF systems provide the proper intended phase and RF voltage to preserve the longitudinal emittance from injection to extraction. In this paper, we describe the original architecture of the cavity phase distribution, our recent beam-based RF phase measurements, observed significant deviation in the relative phases between cavities and correction effort. Results from the improved capture for high intensity beam are also presented.

43 PARTICLE ACCELERATORS↗

Physical studies of Apollo-Amor asteroids - UBVRI photometry of 1036 Ganymed and 1627 Ivar

The 1036 Ganymed and 1627 Ivar photoelectric lightcurves presently discussed indicate in the former case a drastic lightcurve shape change, in conjunction with a significant increase of the synodic rotation period; a substantial change in viewing conditions during the apparition, and a complex interaction between these changes and the asteroid's irregular shape, are indicated by the change. In the latter asteroid's case, a prograde rotation rate is apparent in the observed decrease in synodic period. Both asteroids' phase curves exhibit deviations from the H-G magnitude system phase function at large phase angles.

Hahn, G.↗

Omega flight-test data reduction sequence

Computer programs for Omega data conversion, summary, and preparation for distribution are presented. Program logic and sample data formats are included, along with operational instructions for each program. Flight data (or data collected in flight format in the laboratory) is provided by the Ohio University Omega receiver base in the form of 6-bit binary words representing the phase of an Omega station with respect to the receiver's local clock. All eight Omega stations are measured in each 10-second Omega time frame. In addition, an event-marker bit and a time-slot D synchronizing bit are recorded. Program FDCON is used to remove data from the flight recorder tape and place it on data-processing cards for later use. Program FDSUM provides for computer plotting of selected LOP's, for single-station phase plots, and for printout of basic signal statistics for each Omega channel. Mean phase and standard deviation are printed, along with data from which a phase distribution can be plotted for each Omega station. Program DACOP simply copies the Omega data deck a controlled number of times, for distribution to users.

Lilley, R. W.↗

Effect of physical exercise prelabyrinthectomy on locomotor balance compensation in the squirrel monkey

This study examines the effectiveness of physical exercise, during a prepathology state, on locomotor balance compensation after subsequent unilateral labyrinthectomy in squirrel monkeys. An experimental group underwent 3 hr. of daily running exercise on a treadmill for 3 mo. prior to the surgery, whereas a control group was not exercised. Postoperatively, the locomotor balance function of both groups was tested for 3 mo. There was no significant difference in gait deviation counts in the acute phase of compensation. However, in the chronic compensation maintenance phase, the number of gait deviation counts was fewer in the exercise group, which showed significantly better performance stability.

Non-NASA Center↗

Field-tuned ferroquadrupolar quantum phase transition in the insulator TmVO 4

We report results of low-temperature heat-capacity, magnetocaloric-effect, and neutron-diffraction measurements of TmVO 4 , an insulator that undergoes a continuous ferroquadrupolar phase transition associated with local partially filled 4 f orbitals of the thulium (Tm 3 + ) ions. The ferroquadrupolar transition, a realization of Ising nematicity, can be tuned to a quantum critical point by using a magnetic field oriented along the c axis of the tetragonal crystal lattice, which acts as an effective transverse field for the Ising-nematic order. In small magnetic fields, the thermal phase transition can be well described by using a semiclassical mean-field treatment of the transverse-field Ising model. However, in higher magnetic fields, closer to the field-tuned quantum phase transition, subtle deviations from this semiclassical behavior are observed, which are consistent with expectations of quantum fluctuations. Although the phase transition is driven by the local 4 f degrees of freedom, the crystal lattice still plays a crucial role, both in terms of mediating the interactions between the local quadrupoles and in determining the critical scaling exponents, even though the phase transition itself can be described via mean field. In particular, bilinear coupling of the nematic order parameter to acoustic phonons changes the spatial and temporal fluctuations of the former in a fundamental way, resulting in different critical behavior of the nematic transverse-field Ising model, as compared to the usual case of the magnetic transverse-field Ising model. Our results establish TmVO 4 as a model material and electronic nematicity as a paradigmatic example for quantum criticality in insulators.

36 MATERIALS SCIENCE↗

A binary coherent optical receiver for the free-space channel

The structure of a coherent binary optical MAP receiver was derived and the effects of background radiation and phase estimation errors on receiver performance were evaluated. It was found that random phase errors do not affect the performance of the coherent receiver significantly, as long as the standard deviation of the phase error remains less than roughly 0.14 radians (or 8 degrees). It was also shown that background radiation is effectively suppressed by the optical homodyne receiver: Significant deterioration in receiver performance is observed only in the presence of extremely intense background fields. The most notable characteristic of the binary optical homodyne receiver therefore appears to be its ability to achieve quantum limited performance in high background environments, provided that sufficiently accurate estimates of the received phase can be obtained.

Vilnrotter, V. A.↗

Acyclic High-Energy Variability in Eta Carinae and WR 140

Eta Carinae and WR 140 are similar long-period colliding wind binaries in which X-ray emission is produced by a strong shock due to the collision of the powerful stellar winds. The change in the orientation and density of this shock as the stars revolve in their orbits influences the X-ray flux and spectrum in a phase dependent way. Monitoring observations with RXTE and other X-ray satellite observatories since the 1990s have detailed this variability but have also shown significant deviations from strict phase dependence (short-term brightness changes or "flares", and cyc1e-to-cyc1e average flux differences). We examine these acylic variations in Eta Car and WR 140 and discuss what they tell us about the stability of the wind-wind collision shock.

Corcoran, Michael F.↗

Numerical analysis of natural convection in two-dimensional square and circular containers in low gravity

A numerical study of natural convection in circular cylinder and square enclosures shows that the analytic low Rayleigh number theory of previous investigators is valid for Rayleigh numbers up to 1000. For a Rayleigh number of 5000, steady state values of maximum fluid velocity differ by 20 percent. This deviation between analytic theory and numerical results increases for higher Rayleigh numbers. In addition, the low Rayleigh number theory is shown to be valid for higher Rayleigh numbers for a portion of the transient phase before significant deviation becomes apparent. It is also shown that square shaped experimental configurations may be analytically approximated with good accuracy by circular cylinders of equal cross sectional area for the prediction of convection velocities and flow patterns at low Rayleigh number.

Robertson, S. J.↗