Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Phase-Imaging with a Sharpened Multi-Walled Carbon Nanotube AFM Tip: Investigation of Low-k Dielectric Polymer Hybrids

Phase shift tapping mode scanning force microscopy (TMSFM) has evolved into a very powerful technique for the nanoscale surface characterization of compositional variations in heterogeneous samples. Phase shift signal measures the difference between the phase angle of the excitation signal and the phase angle of the cantilever response. The signal correlates to the tip-sample inelastic interactions, identifying the different chemical and/or physical property of surfaces. In general, the resolution and quality of scanning probe microscopic images are highly dependent on the size of the scanning probe tip. In improving AFM tip technology, we recently developed a technique for sharpening the tip of a multi-walled carbon nanotube (CNT) AFM tip, reducing the radius of curvature of the CNT tip to less than 5 nm while still maintaining the inherent stability of multi-walled CNT tips. Herein we report the use of sharpened (CNT) AFM tips for phase-imaging of polymer hybrids, a precursor for generating nanoporous low-k dielectrics for on-chip interconnect applications. Using sharpened CNT tips, we obtained phase-contrast images having domains less than 10 nm. In contrast, conventional Si tips and unsharpened CNT tips (radius greater than 15 nm) were not able to resolve the nanoscale domains in the polymer hybrid films. C1early, the size of the CNT tip contributes significantly to the resolution of phase-contrast imaging. In addition, a study on the nonlinear tapping dynamics of the multi-walled CNT tip indicates that the multi-walled CNT tip is immune to conventional imaging instabilities related to the coexistence of attractive and repulsive tapping regimes. This factor may also contribute to the phase-contrast image quality of multi-walled CNT AFM tips. This presentation will also offer data in support of the stability of the CNT tip for phase shift TMSFM.

Nguyen, Cattien V.↗

Analyzer-based phase contrast imaging and phase retrieval using a rotating anode x-ray source

We have performed an analyzer crystal based phase contrast imaging (ABI) experiment using a rotating anode x-ray source. The use of such an incoherent source demonstrates the potential of ABI as a quantitative characterization tool for the laboratory environment. A phase contrast image of a plastic phantom was recorded on high resolution x-ray film and the projected thickness was retrieved from a single image. The projected thickness recovered from the phase contrast image was shown to quantitatively agree with a reference optical microscope measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image phase shift invariance based cloud motion displacement vector calculation method for ultra-short-term solar PV power forecasting

Irradiance received on the earth's surface is the main factor that affects the output power of solar PV plants, and is chiefly determined by the cloud distribution seen in a ground-based sky image at the corresponding moment in time. It is the foundation for those linear extrapolation-based ultra-short-term solar PV power forecasting approaches to obtain the cloud distribution in future sky images from the accurate calculation of cloud motion displacement vectors (CMDVs) by using historical sky images. Theoretically, the CMDV can be obtained from the coordinate of the peak pulse calculated from a Fourier phase correlation theory (FPCT) method through the frequency domain information of sky images. The peak pulse is significant and unique only when the cloud deformation between two consecutive sky images is slight enough, which is likely possible for a very short time interval (such as 1?min or shorter) with common changes in the speed of cloud. Sometimes, there will be more than one pulse with similar values when the deformation of the clouds between two consecutive sky images is comparatively obvious under fast changing cloud speeds. This would probably lead to significant errors if the CMDVs were still only obtained from the single coordinate of the peak value pulse. However, the deformation estimation of clouds between two images and its influence on FPCT-based CMDV calculations are terrifically complex and difficult because the motion of clouds is complicated to describe and model. Therefore, to improve the accuracy and reliability under these circumstances in a simple manner, an image-phase-shift-invariance (IPSI) based CMDV calculation method using FPCT is proposed for minute time scale solar power forecasting. First, multiple different CMDVs are calculated from the corresponding consecutive images pairs obtained through different synchronous rotation angles compared to the original images by using the FPCT method. Second, the final CMDV is generated from all of the calculated CMDVs through a centroid iteration strategy based on its density and distance distribution. Third, the influence of different rotation angle resolution on the final CMDV is analyzed as a means of parameter estimation. Simulations under various scenarios including both thick and thin clouds conditions indicated that the proposed IPSI-based CMDV calculation method using FPCT is more accurate and reliable than the original FPCT method, optimal flow (OF) method, and particle image velocimetry (PIV) method.

14 SOLAR ENERGY↗

PyPhase – a Python package for X-ray phase imaging

X-ray propagation-based imaging techniques are well established at synchrotron radiation and laboratory sources. However, most reconstruction algorithms for such image modalities, also known as phase-retrieval algorithms, have been developed specifically for one instrument by and for experts, making the development and diffusion of such techniques difficult. Here, PyPhase, a free and open-source package for propagation-based near-field phase reconstructions, which is distributed under the CeCILL license, is presented. PyPhase implements some of the most popular phase-retrieval algorithms in a highly modular framework supporting its deployment on large-scale computing facilities. This makes the integration, the development of new phase-retrieval algorithms, and the deployment on different computing infrastructures straightforward. Its capabilities and simplicity are presented by application to data acquired at the synchrotron source MAX IV (Lund, Sweden).

36 MATERIALS SCIENCE↗

Virtual phase imager for Galileo

A CCD imaging array with a new virtual-phase technology that has been developed for use in a slow-scan imaging system for NASA's Galileo mission to Jupiter is described. Among its features are an absence of interlevel shorts, simplicity of fabrication, low dark current (less than 0.4 nA/sq cm), high full well, high quantum efficiency in the front side illumination mode, large dynamic range (greater than 5000), good charge transfer efficiency (0.99997), excellent linearity (0.2%), uniform pixel response (1%), and improved radiation hardness. It is noted that its operating voltages must be constrained to narrow windows to maintain good charge transfer efficiency and avoid the production of spurious and leakage charge.

Janesick, J. R.↗

EUV and Hard X-ray Hartmann Wavefront Sensing for Optical Metrology, Alignment and Phase Imaging

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

20 metrology↗

Evaluation of hepatocellular carcinoma ablative margins using fused pre- and post-ablation hepatobiliary phase images

Purpose: To retrospectively evaluate the utility of fusion images of pre- and post-ablation hepatobiliary phase (HBP) series to assess the ablation margins after radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs). Additionally, to identify factors indicative of an adequate ablation margin and predictors of local tumor progression (LTP). Methods: Fifty-nine HCCs in 29 patients were treated by RFA and followed-up for > 1 year (mean 37.9 months). Fusion images of pre- and post-ablation HBP series were created using a non-rigid registration and manual correlation. The ablation margin appearance was classified as ablation margin + (ablation margin completely surrounding the tumor), ablation margin-zero (a partially discontinuous ablation margin without protrusion of HCC), ablation margin—(a partially discontinuous ablation margin with protrusion of HCC), and indeterminate (index tumor was not visible). The minimal ablation margin was measured, and clinical factors were examined to identify other risk factors for LTP. Results: LTP was observed at follow-up in 12 tumors. The mean minimal ablation margin was 3.6 mm. Multivariate analysis revealed that the ablation margin status was the only significant factor (p = 0.028). The cumulative LTP rates (3.3%, 3.3%, and 3.3% at 1, 2, and 3 years, respectively) in 30 ablation margin + nodules were significantly lower (p = 0.006) than those (20.0%, 28.0%, and 32.2% at 1, 2, and 3 years, respectively) in 25 ablation margin-zero nodules. Conclusions: Fusion images enable an early assessment of the ablation efficacy in the majority of HCCs. The ablation margin status is a significant factor for LTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TEM phase contrast imaging with image plane phase grating

Transmission microscopy imaging systems include a mask and/or other modulator situated to encode image beams, e.g., by deflecting the image beam with respect to the mask and/or sensor. The beam is modulated/masked either before or after transmission through a sample to induce a spatially and/or temporally encoded signal by modifying any of the beam/image components including the phase/coherence, intensity, or position of the beam at the sensor. For example, a mask can be placed/translated through the beam so that several masked beams are received by a sensor during a single sensor integration time. Images associated with multiple mask displacements are then used to reconstruct a video sequence using a compressive sensing method. Another example of masked modulation involves a mechanism for phase-retrieval, whereby the beam is modulated by a set of different masks in the image plane and each masked image is recorded in the diffraction plane.

47 OTHER INSTRUMENTATION↗

Evaluation of gratings for X-ray and neutron phase imaging techniques by using x-ray projection microscope

In the X-ray and neutron Talbot (-Lau) interferometry, fabrication of phase or amplitude grating with a high-aspect ratio is a key factor to obtain high quality images. To improve the ability of the grating, evaluation of shape and thickness variation and feed-back to the fabrication process are essential. Here, it is shown that X-ray projection microscope with a spatial resolution of sub-micrometer is a powerful tool for the purpose. Three kinds of gratings have been evaluated by using a projection X-ray microscope with X-ray source size of 0.6 micrometer. Uniformity of thickness of the grating has been visualized nondestructively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Imaging: A Compressive Sensing Approach

Since Wolfgang Pauli posed the question in 1933, whether the probability densities |Ψ(r)|² (real-space image) and |Ψ(q)|² (reciprocal space image) uniquely determine the wave function Ψ(r) [1], the so called Pauli Problem sparked numerous methods in all fields of microscopy [2, 3]. Reconstructing the complete wave function Ψ(r) = a(r)e-iφ(r) with the amplitude a(r) and the phase φ(r) from the recorded intensity enables the possibility to directly study the electric and magnetic properties of the sample through the phase. In transmission electron microscopy (TEM), electron holography is by far the most established method for phase reconstruction [4]. Requiring a high stability of the microscope, next to the installation of a biprism in the TEM, holography cannot be applied to any microscope straightforwardly. Recently, a phase retrieval approach was proposed using conventional TEM electron diffractive imaging (EDI). Using the SAD aperture as reciprocal-space constraint, a localized sample structure can be reconstructed from its diffraction pattern and a real-space image using the hybrid input-output algorithm [5]. We present an alternative approach using compressive phase-retrieval [6]. Our approach does not require a real-space image. Instead, random complimentary pairs of checkerboard masks are cut into a 200 nm Pt foil covering a conventional TEM aperture (cf. Figure 1). Used as SAD aperture, subsequently diffraction patterns are recorded from the same sample area. Hereby every mask blocks different parts of gold particles on a carbon support (cf. Figure 2). The compressive sensing problem has the following formulation. First, we note that the complex-valued reciprocal-space wave-function is the Fourier transform of the (also complex-valued) real-space wave-function, Ψ(q) = F[Ψ(r)], and subsequently the diffraction pattern image is given by |Ψ(q)|2 = |F[Ψ(r)]|2. We want to find Ψ(r) given a few differently coded diffraction pattern measurements yn = |F[HnΨ(r)]|2, where the matrices Hn encode the mask structure of the aperture. This is a nonlinear inverse problem, but has been shown to be solvable even in the underdetermined case [6]. Since each diffraction pattern yn contains diffraction information from selected regions of the same sample, the differences in each pattern contain local phase information, which can be combined to form a full estimate of the real-space wave-function[7]. References: [1] W. Pauli in “Die allgemeinen Prinzipien der Wellenmechanik“, ed. H Geiger and W Scheel, (Julius Springer, Berlin). [2] A. Tonomura, Rev. Mod. Phys. 59 (1987), p. 639. [3] J. Miao et al, Nature 400 (1999), p. 342. [4] H. Lichte et al, Annu. Rev. Mater. Res. 37 (2007), p. 539. [5] J. Yamasaki et al, Appl. Phys. Lett. 101 (2012), 234105. [6] P Schniter and S Rangan. Signal Proc., IEEE Trans. on. 64(4), (2015), pp. 1043. [7] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Schneider, Sebastian↗

Imaging Phase Segregation in Nanoscale Li x CoO 2 Single Particles

Li x CoO 2 (LCO) is a common battery cathode material that has recently emerged as a promising material for other applications including electrocatalysis and as electrochemical random access memory (ECRAM). During charge– discharge cycling LCO exhibits phase transformations that are significantly complicated by electron correlation. While the bulk phase diagram for an ensemble of battery particles has been studied extensively, it remains unclear how these phases scale to nanometer dimensions and the effects of strain and diffusional anisotropy at the single-particle scale. Understanding these effects is critical to modeling battery performance and for predicting the scalability and performance of electrocatalysts and ECRAM. Here we investigate isolated, epitaxial LiCoO 2 islands grown by pulsed laser deposition. After electrochemical cycling of the islands, conductive atomic force microscopy (c-AFM) is used to image the spatial distribution of conductive and insulating phases. Above 20 nm island thicknesses, we observe a kinetically arrested state in which the phase boundary is perpendicular to the Li-planes; we propose a model and present image analysis results that show smaller LCO islands have a higher conductive fraction than larger area islands, and the overall conductive fraction is consistent with the lithiation state. Thinner islands (14 nm), with a larger surface to volume ratio, are found to exhibit a striping pattern, which suggests surface energy can dominate below a critical dimension. When increasing force is applied through the AFM tip to strain the LCO islands, significant shifts in current flow are observed, and underlying mechanisms for this behavior are discussed. The c-AFM images are compared with photoemission electron microscopy images, which are used to acquire statistics across hundreds of particles. Finally, the results indicate that strain and morphology become more critical to electrochemical performance as particles approach nanometer dimensions.

25 ENERGY STORAGE↗

Quantitative phase imaging around water vapor microbubbles under pulsed laser illumination

We measured water temperature around a self-oscillating water vapor-rich bubble using diffraction phase microscopy equipped with a pulsed laser. The water vapor-rich bubble, which causes a strong water flow around it, was generated by locally heating degassed water through the photothermal conversion properties of an FeSi2 thin film. The generation of the flow is related to the self-oscillation of the bubble at sub-MHz frequencies and the temperature distribution around it. Here, the refractive index of the surrounding water was measured using a pulsed laser with a 3.5-ns pulse duration, which guarantees a time resolution of less than 1/200 of the oscillation cycle of the bubble. The temperature distribution around the bubble was calculated from the measured refractive index.

Narihira, Kyoshiro [Kyoto University, Japan]↗

Quantitative phase imaging by three-wavelength digital holography

Three-wavelength digital holography is applied to obtain surface height measurements over several microns of range, while simultaneously maintaining the low noise precision of the single wavelength phase measurement. The precision is preserved by the use of intermediate synthetic wavelength steps generated from the three wavelengths and the use of hierarchical optical phase unwrapping. As the complex wave-front of each wavelength can be captured simultaneously in one digital image, real-time performance is achievable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging (Phase III)

Due to rapidly changing sky conditions, the available solar irradiance for energy generation is subject to wide swings in amplitude. As the market penetration of solar energy continues to increase rapidly, these variations in solar power generation are beginning to have an impact on grid stability and increased wear on power switches. Solar power forecasting plays a critical role in operations for Independent System Operators (ISOs) and utilities. Accurate forecasts help maintain grid reliability, optimize generation from renewables, and reduce operating costs. Of particular interest to the ISOs and utilities are sudden changes in solar irradiance, termed “ramp events,” due to the movement of clouds. One significant impact of ramp events on the grid is additional ancillary service requirements necessary to manage such variability. Ramp events can also cause voltage fluctuations in the distribution grids and trigger actions of automated line equipment (e.g., tap changers), leading to additional maintenance costs. In high penetration solar regions, forecasts must be made for both transmission-connected and distribution-connected resources – either behind the meter or in front of it. Particularly for distributed solar energy resources, forecasting can be a challenge due to the lack of visibility of the energy resource. Brookhaven National Laboratory (BNL) has been working towards nowcasting Global Horizontal Irradiance (GHI) using low-cost technologies for several years now. The Solar NowCasting technology being developed by BNL is a 0 – 30 min solar “nowcasting” technology applicable to a scale covering both large generating facilities and residential, distributed solar installations that relies on a network of ground-based high-definition (HD) cameras and surface pyranometers. GHI forecasts are being produced for both regions using 8 ground-based HD cameras and at least 2 surface pyranometers. When stitched together, the camera images can be used to forecast the impact of clouds on available solar irradiance over a domain of ~50 km 2 . Phase I of the project was the engineering scale up conceptual design stage. Phase II was the initial field test and demonstration, in which the technology was scaled up by a factor of 20 times and successfully demonstrated in eastern Long Island. In Phase III, an additional forecasting network was added in upstate NY and both networks are currently being operated until at least a full year of data is gathered by the Albany network to allow for the collection of sufficient data to evaluate performance against the persistence and smart persistence models using the Solar Arbiter.

14 SOLAR ENERGY↗

Fabrication of large area X-ray diffraction grating for X-ray phase imaging

X-ray lithography, which uses highly directional synchrotron radiation, is one of the technologies that can be used for fabricating micrometer-sized structures. In X-ray lithography, the accuracy of the fabricated structure depends largely on the accuracy of the X-ray mask. Since X-ray radiation is highly directional, a micro-fabrication technology that produces un-tapered and high aspect ratio highly absorbent structures on a low absorbent membrane is required. Conventionally, a resin material is used as the support membrane for large area X-ray masks. However, resin membranes have the disadvantage that they can sag after several cycles of X-ray exposure due to the heat generated by the X-rays. Therefore, we proposed and used thin carbon wafers for the membrane material because carbon has an extremely small thermal expansion coefficient. We fabricated new carbon membrane X-ray masks, and these results of X-ray lithography demonstrate the superior performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗