Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOSPHOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface Temperature Measurements from a Stator Vane Doublet in a Turbine Engine Afterburner Flame using Ultra-Bright Cr-Doped GdAlO3 Thermographic Phosphor

Luminescence-based surface temperature measurements from an ultra-bright Cr-doped GdAlO3 perovskite (GAP:Cr) coating were successfully conducted on an air-film-cooled stator vane doublet exposed to the afterburner flame of a J85 test engine at University of Tennessee Space Institute (UTSI). The objective of the testing at UTSI was to demonstrate that reliable thermal barrier coating (TBC) surface temperatures based on luminescence decay of a thermographic phosphor could be obtained from the surface of an actual engine component in an aggressive afterburner flame environment and to address the challenges of a highly radiant background and high velocity gases. A high-pressure turbine vane doublet from a Honeywell TECH7000 turbine engine was coated with a standard electron-beam physical vapor deposited (EB-PVD) 200-m-thick TBC composed of yttria-stabilized zirconia (YSZ) onto which a 25-m-thick GAP:Cr thermographic phosphor layer was deposited by EB-PVD. The ultra-bright broadband luminescence from the GAP:Cr thermographic phosphor is shown to offer the advantage of over an order-of-magnitude greater emission intensity compared to rare-earth-doped phosphors in the engine test environment. This higher emission intensity was shown to be very desirable for overcoming the necessarily restricted probe light collection solid angle and for achieving high signal-to-background levels. Luminescence-decay-based surface temperature measurements varied from 500 to over 1000C depending on engine operating conditions and level of air film cooling.

Eldridge, Jeffrey I.↗

Systems and methods for fluoride ceramic phosphors for LED lighting

The present disclosure relates to a lighting component which may comprise a light emitting diode (LED) or laser diode (LD) for generating at least one of blue light or ultraviolet light. A fluoride phosphor matrix may be included, which may be consolidated into a phosphor ceramic structure including at least one of a transparent fluoride ceramic structure or a translucent fluoride ceramic structure, and positioned adjacent to the LED or LD. The phosphor ceramic structure generates at least one of red or orange light when irradiated by the light emitted from the LED or LD. The phosphor ceramic structure exhibits reduced thermal quenching relative to a fluoride particulate structure irradiated by the LED or LD.

Cherepy, Nerine↗

Thermographic phosphor digital image correlation

The invention advances the ratio method of phosphor thermography using two machine vision cameras for full-field temperature measurements of a solid surface. As an example, algorithms from digital image correlation (DIC) can be used to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. A phosphor calibration sample fabricated using aerosol deposition can be used for in situ determination of the temperature-versus-intensity ratio relationship. The full calibration methodology and several improvements on two-color phosphor thermography open the door for full-field temperature measurements in dynamic tests with deforming test specimens. In particular, thermographic phosphors can be combined with stereo digital image correlation in a novel diagnostic, TP+DIC, to measure time-resolved full-field surface strains and temperatures simultaneously, thereby enabling testing in combined thermo-mechanical environments.

Winters, Caroline↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of rare-earth substitution on the Debye temperature of inorganic phosphors

In the quest to predict photoluminescent efficiency in rare-earth substituted inorganic phosphors, research has shown that materials consisting of ordered, rigid crystal structures tend to possess the highest photoluminescent quantum yields. A compound's Debye temperature (Θ D ), which can be calculated using ab initio calculations, is an ideal proxy for quantitatively comparing structural rigidity among different inorganic compounds, allowing potentially efficient phosphors to be selected from large crystal structure databases. However, the high computational cost of these calculations limits estimating Θ D for unsubstituted host crystal structures only. It is assumed that the low substitution concentration of the rare-earth luminescent center does not significantly influence a material's Debye temperature. This work evaluates the validity of this approximation by examining the effect of luminescent center substitution on a host structure's Θ D . Two well-known phosphors, (Y 1– x Ce x ) 3 Al 5 O 12 ( x = 0 – 0.05) and Ba 1-δ Eu δ MgAl 10 O 17 (δ = 0 – 0.15), were synthesized with varying rare-earth concentrations, while Θ D was computationally estimated and then determined by ultrasonic pulse-echo speed-of-sound and low-temperature heat capacity measurements. Overall, the ensuing results provide key implications for using Θ D as a proxy for structural rigidity in substituted inorganic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the process-structure-property relationship of Aerosol Deposition to phosphor coatings for non-contact thermometry

Full-field, multi-measurand diagnostics provide rich validation data necessary to improve the product life cycle time of nuclear safety components. Thermophosphor digital image correlation (TP+DIC) is a method of simultaneously measuring strain and temperature fields using patterned phosphor coatings deposited with aerosol deposition (AD). While TP+DIC produces a functional diagnostic, the coating’s reproducibility and the effect of the patterned features on the inferred temperature remains uncharacterized. This NSR&D project provided the opportunity to study two areas: 1) the tunability and repeatability of aerosol deposition and 2) the robustness of aerosol deposition phosphor on deforming substrates. The first area explores the process-property relationship of parameters elucidating the significance of each on the coating. The second area explores the relationship between the features’ characteristics (namely thickness) and the phosphor emission and inferred temperature. Together, the results will lead to the improved accuracy and functionality of TP+DIC for qualification testing of nuclear safety components.

36 MATERIALS SCIENCE↗

Custom blending of lamp phosphors

Spectral output of fluorescent lamps can be precisely adjusted by using computer-assisted analysis for custom blending lamp phosphors. With technique, spectrum of main bank of lamps is measured and stored in computer memory along with emission characteristics of commonly available phosphors. Computer then calculates ratio of green and blue intensities for each phosphor according to manufacturer's specifications and plots them as coordinates on graph. Same ratios are calculated for measured spectrum. Once proper mix is determined, it is applied as coating to fluorescent tubing.

Klemm, R. E.↗

Cathode catalysts for primary phosphoric acid fuel cells

Alkylation or carbon Vulcan XC-72, the support carbon, was shown to provide the most stable bond type for linking cobalt dehydrodibenzo tetraazannulene (CoTAA) to the surface of the carbon; this result is based on data obtained by cyclic voltammetry, pulse voltammetry and by release of 14C from bonded CoTAA. Half-cell tests at 100 C in 85% phosphoric acid showed that CoTAA bonded to the surface of carbon (Vulcan XC-72) via an alkylation procedure is a more active catalyst than is platinum based on a factor of two improvement in Tafel slope; dimeric CoTAA had catalytic activity equal to platinum. Half-cell tests also showed that bonded CoTAA catalysts do not suffer a loss in potential when air is used as a fuel rather than oxygen. Commercially available polytetrafluroethylene (PTFE) was shown to be unstable in the fuel cell environment with degradation occurring in 2000 hours or less. The PTFE was stressed at 200 C in concentrated phosphoric acid as well as electrochemically stressed in 150 C concentrated phosphoric acid; the surface chemistry of PTFE was observed to change significantly. Radiolabeled PTFE was prepared and used to verify that such chemical changes also occur in the primary fuel cell environment.

Source record↗

Cathode catalyst for primary phosphoric fuel cells

Alkylation of Vulcan XC-72 provided the most stable bond type for linking CoTAA to the surface of the carbon; this result is based on data obtained by cyclic voltammetry, pulse voltammetry and by release of 14C from bonded CoTAA. Half-cell tests at 100 C in 85% phosphoric acid showed that CoTAA bonded to the surface of carbon (Vulcan XC-72) via an alkylation procedure is a more active catalyst than is platinum based on a factor of two improvement in Tafel slope; dimeric CoTAA has catalytic activity equal to platinum. Half-cell tests also showed that bonded CoTAA catalysts do not suffer a loss in potential when air is used as a fuel rather than oxygen. Commercially available PTFE was shown to be stable for four months in 200 C 85% phosphoric acid based on lack of change in surface wetting properties, IR and physical characteristics. When stressed electrochemically in 150 C 85% phosphoric acid, PTFE also showed no changes after one month.

Walsh, F.↗

Ultraviolet /UV/ sensitive phosphors for silicon imaging detectors

The fluorescence properties of UV sensitive organic phosphors and the radiometric properties of phosphor coated silicon detectors in the VUV, UV, and visible wavelengths are described. With evaporated films of coronene and liumogen, effective quantum efficiencies of up to 20% have been achieved on silicon photodiodes in the vacuum UV. With thin films of methylmethacrylate (acrylic), which are doped with organic laser dyes and deposited from solution, detector quantum efficiencies of the order of 15% for wavelengths of 120-165 nm and of 40% for wavelengths above 190 nm have been obtained. The phosphor coatings also act as antireflection coatings and thereby enhance the response of coated devices throughout the visible and near IR.

Viehmann, W.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Surface temperature/heat transfer measurement using a quantitative phosphor thermography system

A relative-intensity phosphor thermography technique developed for surface heating studies in hypersonic wind tunnels is described. A direct relationship between relative emission intensity and phosphor temperature is used for quantitative surface temperature measurements in time. The technique provides global surface temperature-time histories using a 3-CCD (Charge Coupled Device) video camera and digital recording system. A current history of technique development at Langley is discussed. Latest developments include a phosphor mixture for a greater range of temperature sensitivity and use of castable ceramics for inexpensive test models. A method of calculating surface heat-transfer from thermal image data in blowdown wind tunnels is included in an appendix, with an analysis of material thermal heat-transfer properties. Results from tests in the Langley 31-Inch Mach 10 Tunnel are presented for a ceramic orbiter configuration and a four-inch diameter hemisphere model. Data include windward heating for bow-shock/wing-shock interactions on the orbiter wing surface, and a comparison with prediction for hemisphere heating distribution.

Buck, G. M.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Quantitative surface temperature measurement using two-color thermographic phosphors and video equipment

A thermal imaging system provides quantitative temperature information and is particularly useful in hypersonic wind tunnel applications. An object to be measured is prepared by coating with a two-color, ultraviolet-activated, thermographic phosphor. The colors emitted by the phosphor are detected by a conventional color video camera. A phosphor emitting blue and green light with a ratio that varies depending on temperature is used so that the intensity of light in the blue and green wavelengths detected by the blue and green tubes in the video camera can be compared. Signals representing the intensity of blue and green light at points on the surface of a model in a hypersonic wind tunnel are used to calculate a ratio of blue to green light intensity which provides quantitative temperature information for the surface of the model.

Buck, Gregory M.↗

Temperature Sensing to Above 1500 °C Using Y 2 SiO 5 :Er Phosphor Thermometry

A transition from metallic to ceramic turbine components that can operate at higher turbine engine temperatures will push component surface temperatures from below 1200 °C into a 1300 to 1500 °C temperature range that is much more challenging for phosphor thermometry measurements. To address this challenge, Y 2 SiO 5 :Er was selected for its high temperature sensing performance by both luminescence lifetime and luminescence intensity ratio (LIR) methods as well as its thermochemical compatibility with the current generation of rare earth silicate environmental barrier coatings (EBCs) that are required to protect SiC/SiC ceramic composite components. Lifetime measurements that monitor the Er3+ 4S3/2→4I15/2 emission decay at 542 nm exhibited a slow decrease in decay time with temperature up to 1300° C, above which the decay decreased steeply to provide good temperature sensitivity in the 1300 to 1500 °C range (Fig. 1). LIR images were obtained where each pixel represented the ratio I488/I561 (I488 and I561 are the detected 488 nm 4F7/2→4I15/2 and the 561 nm 4S3/2→4I15/2 emission band intensities, respectively). Good temperature sensitivity (Fig. 2) and signal-to-background ratios were observed to above 1500 °C. Contrary to conventional guidance on selecting phosphors for high temperature sensing, the detected emission band intensities and decay times exhibited remarkably slow decreases with temperature up into the 1300 to 1500 °C range despite high phonon energies (>900 cm-1) that allow the energy gap between the 4S3/2 emitting reservoir level and the 4F9/2 level below it to be bridged by as few as three phonons. The benefits of utilizing a thermographic phosphor at very high temperatures that exhibits strong nonradiative multiphonon relaxation even at room temperature is explained by a competition between spontaneous and stimulated multiphonon emission, and the more temperature-sensitive decay time above 1300 °C is explained by a transition from high to low effective phonon energies.

temperature measurement↗

Aqueous Ni-rich-cathode dispersions processed with phosphoric acid for lithium-ion batteries with ultra-thick electrodes

Lithium-ion battery (LIB) production can benefit both economically and environmentally from aqueous processing. Although these electrodes have the potential to surpass electrodes conventionally processed with N -methyl-2-pyrrolidone (NMP) in terms of performance, significant issues still exist with respect to ultra-thick cathodes ($\gg$4 mAh/cm 2 areal capacities). A major concern for these types of electrodes with high-nickel active material stems from lithium leaching from active material, which drives the pH of the dispersion in excess of 12 and subsequently corrodes the current collector interface. As this corrosion reaction proceeds, hydrogen generation at the interface creates bubbles which cause severe cracking in the dried electrode surface. When areal loadings are increased, this effect becomes more pronounced and is detrimental to both mechanical and electrochemical properties of these electrodes. In this work, a technique for mitigating corrosion at the current collector by adjusting the pH of the dispersion with the addition of phosphoric acid is investigated. Phosphoric acid was added in 0.5 wt% increments between 0.0 and 1.5 wt%, and effects on rheology, adhesion, corrosion, and electrochemical performance were investigated. A technique is reported for producing aqueous processed cathodes with areal loadings of 6–8 mAh/cm 2 with reduced surface cracking and superior high-rate discharge capacity (i.e. high-power performance) for this class of cathode loadings.

25 ENERGY STORAGE↗

High-Temperature Rotating Disk Electrode Study of Platinum Bimetallic Catalysts in Phosphoric Acid

Understanding the H 3 PO 4 effect on the catalyst’s activity under a relevant condition is important for high-temperature polymer electrolyte membrane fuel cell (HT-PEMFC) catalyst research. Here, we report a high-temperature rotating disk electrode (HT-RDE) study of oxygen reduction reaction (ORR) in H 3 PO 4 . With the regular electrochemical protocol, we found that H 3 PO 4 reduction could occur during cyclic voltammetry study and form a reductive species—phosphorus acid (H 3 PO 3 ). Further, to obtain reliable ORR measurement, we optimized the protocol to avoid the H 3 PO 3 generation. The ORR activity of carbon-supported PtM (M = Fe, Co, Ni, Ru, Pd, and Ir) bimetallic alloy catalysts measured with this HT-RDE method showed higher ORR activity than Pt. To understand the alloying effect, we combine experiments in diluted solutions to distinguish the alloying effect on Pt–O binding and Pt–H 3 PO 4 binding. The results indicate that H 3 PO 4 mainly reduces available sites for ORR, with little effect on neighboring site’s Pt–O binding via Pt–H 3 PO 4 interaction, which is also supported by the density functional theory calculation of the Pt–O binding energy with/without H 2 PO 4 . Further study in a phosphoric acid-doped quaternary ammonium-biphosphate ion pair coordinated polyphenylene (PA-QAPOH) membrane electrode assembly (MEA) shows that the active alloy catalyst has better performance in both the HT-RDE and MEA. Also, the MEA gives higher ORR activity than the HT-RDE because of the higher pressure and less phosphoric acid content of the MEA. Yet, the gap between the HT-RDE and MEA is significantly smaller than that between the room temperature (RT)-RDE and MEA, suggesting the importance of temperature and H 3 PO 4 concentration in understanding ORR in HT-PEMFCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗