Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

High Resolution Stereoscopic PIV Measurements in a 5 x 5 Rod Bundle with Mixing Vane

Spacer grids are used in the pressurized water reactor (PWR) to fix, clamp the fuel rods, and enhance the turbulence mixing within the spaces of the rods and overall heat transfer performance. Proper understanding on the thermal-hydraulic characteristics of the turbulent mixing and heat transfer created by the space grids is important. However, spacer grids having complex design structure with dimple, mixing vane and spring have been challenges for computational fluid dynamics (CFD) turbulent models. High fidelity experimental data with spatial-temporal resolutions is essential to validate and assess the performances of CFD models. Baglietto and Ninokata applied an improved realizable anisotropic turbulence models via direct numerical simulation (DNS)-based near-wall formulation data to study the wall shear stresses and flow structures in tight bundle subchannels. These authors have shown that their models are able to capture the stress distribution and velocity field at an acceptable accuracy. The authors numerically studied the flow field characteristics at the region downstream of the spacer grids, and validated their results to particle imagery velocimetry (PIV) measurements. Dominguez and Hassan performed two-dimensional time resolved PIV (TR-PIV) measurements within a 5 x 5 PWR rod bundle with spacer-grids that utilized a matching index of refraction (MIR) approach. Their averaged data showed a rather uniform direction velocity profile after the spacer grid while the downstream illustrated a no slip wall profile. In this paper, we presents flow measurements in the MIR 5 x 5 fuel rod bundle with a spacer grid. Time resolved stereoscopic PIV (TR-SPIV) measurements were performed to obtain high spatial-temporal resolution two-dimensional three-component (2D3C) velocity vector fields in the subchannels between the rods. Flow statistics such as mean velocity, and Reynolds stresses were computed. The obtained experimental data can be used to improve the computational modeling and validate the numerical models that are currently applied to light and pressurized water reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-Resolved PIV Diagnostics to Measure Flow Field Exiting Methane-Fueled Rotating Detonation Combustor

Time-resolved particle image velocimetry (TR-PIV) is applied to measure the flow field at the immediate exit of a rotating detonation combustor (RDC) operating on methane fuel and oxygen-enriched air, and configured with a back-pressure choke-plate. The challenges inherent to obtaining temporally consistent and spatially-well distributed seeded flow in a highly-periodic, supersonic, reacting flow field are discussed. Likewise, various measures taken to accurately implement the diagnostic and yield analytical results are detailed. The discussion includes laser optics configuration to maximize laser intensity in the region of interest, and consideration of seeder design and various seed materials and sizes to yield optimized results. Results acquired at 50 kHz PIV acquisition rate are presented to show the flow-field in two-dimensions: axial and circumferential velocity components. Results show that while the flow is primarily axial, a significant circumferential velocity component is also present. The flow oscillates in both directions with the passing of an oblique-shock structure in the PIV region of interest. Recommendations to improve the consistency and precision of the system for future studies are noted.

03 NATURAL GAS↗

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction↗

PIV Measurements of Shock-Wave/Boundary-Layer Interactions at Mach 2.5 in a Circular Test Section

The particle image velocimetry (PIV) measurement technique has been applied to make detailed measurements in an impinging shock-wave/boundary-layer interaction (SWBLI) flowfield in a test section of circular cross-section. By virtue of this test section geometry, the flowfields studied are free from effects of the complex coupling of sidewall and corner interaction into the primary impinging shock interaction typical of a rectangular test section. The cone-cylinder shock generator hardware was arranged in both coaxial alignment with the test section to generate axisymmetric SWBLIs and in offset positions to generate swept SWBLIs. The angle of the conical section was also varied to alter the strength of the impinging shock wave. The application of the PIV technique in this test section required meticulous design to provide adequate optical access without disturbing the SWBLI flow. Details of the stereoscopic PIV apparatus and the velocity measurements obtained for a Mach 2.5 freestream are presented. Key features of the mean velocity and turbulent stress fields are highlighted. This data set should enable validation of computational fluid dynamics results for these flowfields.

Shockwave Boundary Layer Interaction↗

Techniques of PIV in stratified two-phase headers

The stratification of two fluid phases, namely gas and liquid, within flow distribution devices, such as headers, that have side or bottom oriented fluid pipe connections, or discharges, has shown relevance to loss-of-coolant accidents in nuclear power plants. Under critical conditions the gas phase could entrain into the predominantly liquid discharge flow causing the fluid quality to be dramatically affected. This condition is referred to as the onset of gas entrainment (OGE) phenomenon and it occurs at a specific critical liquid height which changes with the Froude number. The liquid velocity field at the OGE is of importance, for example, to theorists who may find a semi-empirical approach to model this phenomenon. Stereoscopic particle image velocimetry (PIV) technique is an excellent candidate for non-intrusively investigating the velocity field. The liquid-phase velocity field was investigated for three discharge Froude numbers at the OGE. It was found that the stereoscopic PIV could be used to extract the velocity field experimentally, yet a high degree of error was found in the region closest to the discharge. The relative error was determined through conservation of mass by comparing the flow rate obtained with the PIV data to that obtained using a flow meter. In summary it was found that the number of image planes used, the resolution of the image planes, and consequently the number of vectors used to calculate the flow rate, all contributed a great deal to the relative error. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Particle Image Velocimetry (PIV) Data for Acoustic Velocity Measurements

Acoustic velocity measurements were taken using Particle Image Velocimetry (PIV) in a Normal Incidence Tube configuration at various frequency, phase, and amplitude levels. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Estimates of lower measurement sensitivity levels were determined based on PIV image quality, correlation, and noise level parameters used in the test. Comparison of measurements with linear acoustic theory are presented. The onset of nonlinear, harmonic frequency acoustic levels were also studied for various decibel and frequency levels ranging from 90 to 132 dB and 500 to 3000 Hz, respectively.

Blackshire, James L.↗

Analysis of Particle Image Velocimetry (PIV) Data for Application to Subsonic Jet Noise Studies

Global velocimetry measurements were taken using Particle Image Velocimetry (PIV) in the subsonic flow exiting a 1 inch circular nozzle in an attempt to better understand the turbulence characteristics of its shear layer region. This report presents the results of the PIV analysis and data reduction portions of the test and details the processing that was done. Custom data analysis and data validation algorithms were developed and applied to a data ensemble consisting of over 750 PIV 70 mm photographs taken in the 0.85 mach flow facility. Results are presented detailing spatial characteristics of the flow including ensemble mean and standard deviation, turbulence intensities and Reynold's stress levels, and 2-point spatial correlations.

Blackshire, James L.↗

MSTB 2 x 6-Inch Low Speed Tunnel Turbulence Generator Grid/Honeycomb PIV Measurements and Analysis

An assessment of the turbulence levels present in the Measurement Science and Technology (MSTB) branch's 2 x 6-inch low speed wind tunnel was made using Particle Image Velocimetry (PIV), and a turbulence generator consisting of a grid/honeycomb structure. Approximately 3000 digital PIV images were captured and analyzed covering an approximate 2 x 6-inch area along the centerline of the tunnel just beyond the turbulence generator system. Custom software for analysis and acquisition was developed for semi-automated digital PIV image acquisition and analysis. Comparisons between previously obtained LTA and LV turbulence measurements taken in the tunnel are presented.

Blackshire, James L.↗

Digital PIV (DPIV) Software Analysis System

A software package was developed to provide a Digital PIV (DPIV) capability for NASA LaRC. The system provides an automated image capture, test correlation, and autocorrelation analysis capability for the Kodak Megaplus 1.4 digital camera system for PIV measurements. The package includes three separate programs that, when used together with the PIV data validation algorithm, constitutes a complete DPIV analysis capability. The programs are run on an IBM PC/AT host computer running either Microsoft Windows 3.1 or Windows 95 using a 'quickwin' format that allows simple user interface and output capabilities to the windows environment.

Blackshire, James L.↗

Velocity Fields of Axisymmetric Hydrogen-Air Counterflow Diffusion Flames from LDV, PIV, and Numerical Computation

Laminar fuel-air counterflow diffusion flames (CFDFs) were studied using axisymmetric convergent-nozzle and straight-tube opposed jet burners (OJBs). The subject diagnostics were used to probe a systematic set of H2/N2-air CFDFs over wide ranges of fuel input (22 to 100% Ha), and input axial strain rate (130 to 1700 Us) just upstream of the airside edge, for both plug-flow and parabolic input velocity profiles. Laser Doppler Velocimetry (LDV) was applied along the centerline of seeded air flows from a convergent nozzle OJB (7.2 mm i.d.), and Particle Imaging Velocimetry (PIV) was applied on the entire airside of both nozzle and tube OJBs (7 and 5 mm i.d.) to characterize global velocity structure. Data are compared to numerical results from a one-dimensional (1-D) CFDF code based on a stream function solution for a potential flow input boundary condition. Axial strain rate inputs at the airside edge of nozzle-OJB flows, using LDV and PIV, were consistent with 1-D impingement theory, and supported earlier diagnostic studies. The LDV results also characterized a heat-release hump. Radial strain rates in the flame substantially exceeded 1-D numerical predictions. Whereas the 1-D model closely predicted the max I min axial velocity ratio in the hot layer, it overpredicted its thickness. The results also support previously measured effects of plug-flow and parabolic input strain rates on CFDF extinction limits. Finally, the submillimeter-scale LDV and PIV diagnostics were tested under severe conditions, which reinforced their use with subcentimeter OJB tools to assess effects of aerodynamic strain, and fueVair composition, on laminar CFDF properties, including extinction.

Pellett, Gerald L.↗

Application of Stereo PIV on a Supersonic Parachute Model

The Mars Science Laboratory (MSL) is the next step in NASA's Mars Exploration Program, currently scheduled for 2011. The spacecraft's descent into the Martian atmosphere will be slowed from Mach 2 to subsonic speeds via a large parachute system with final landing under propulsive control. A Disk-Band-Gap (DBG) parachute will be used on MSL similar to the designs that have been used on previous missions, however; the DBG parachute used by MSL will be larger (21.5 m) than in any of the previous missions due to the weight of the payload and landing site requirements. The MSL parachute will also deploy at higher Mach number (M 2) than previous parachutes, which can lead to instabilities in canopy performance. Both the increased size of the DBG above previous demonstrated configurations and deployment at higher Mach numbers add uncertainty to the deployment, structural integrity and performance of the parachute. In order to verify the performance of the DBG on MSL, experimental testing, including acquisition of Stereo Particle Imaging Velocimetry (PIV) measurements were required for validating CFD predictions of the parachute performance. A rigid model of the DBG parachute was tested in the 10x10 foot wind tunnel at GRC. Prior to the MSL tests, a PIV system had never been used in the 10x10 wind tunnel. In this paper we discuss some of the technical challenges overcome in implementing a Stereo PIV system with a 750x400 mm field-of-view in the 10x10 wind tunnel facility and results from the MSL hardshell canopy tests.

Wernet, Mark P.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48 cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Raman Scattering↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Wernet, Mark P.↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient thin film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better turbulence models. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity and also the mean temperature and normalized root mean square (rms) temperatures in a single injector cooling flow arrangement. In addition to flowfield measurements, thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of radial and axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures and Mach numbers, across a 30.48cm long plate equipped with a single injector cooling hole. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 15 axial stations were collected in the same flows. The velocity and temperature data were then compared against Wind-US CFD code predictions for the same flow conditions. The results of this and planned follow-on studies will support NASA's development and assessment of turbulence models for heated flows.

Turbulence Modeling↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

IR camera Measurments↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow: Part 1

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hot or combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained for use in assessing current CFD capabilities and for development of better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean velocity, turbulence intensity as well as the mean temperature and root mean square (rms) temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR = 2.7) and Mach numbers (up to M0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both centerline streamwise 2-component PIV and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part I report and are available from the NASA STI office. The final portion of the data will be published in a future report, Part II, along with CFD predictions of the complex cooling film flow.

Raman Scattering↗

Validation and Uncertainty Analysis of Stereo Time-Resolved PIV Measurements for Boundary-Layer Transition Research

An uncertainty analysis was performed on the stereo time-resolved particle image velocimetry measurements that were obtained in the boundary-layer of a swept wing model. Several different approaches were undertaken to estimate the uncertainty of the PIV measurements and to understand how that uncertainty propagates through to the results of interest. It was found that the stereo registration error, which is often neglected in stereo- PIV uncertainty analysis, can cause significant errors in the measured amplitude of the stationary cross ow instability due to the large spanwise velocity gradients that occur in the ow. The self-calibrations do not always adequately correct for the stereo-registration error. A simple approach is demonstrated for estimating the error due to a misalignment of the calibration target and laser plane. This approach was found to be very successful at predicting the error in stationary cross ow amplitude caused by the misalignment. The time-resolved PIV results are also compared to previously-acquired hotwire data. The TRPIV technique is successful at measuring the same types of unsteady instabilities as the hotwire, and thus does not appear to have any adverse e ect on the transition process due to the introduction of particles into the ow. It was also found that a larger interrogation window size is beneficial for reducing the noise of the TRPIV results.

Eppink, Jenna L.↗