Comparative study of radiation emission without and with target in a 2.2 kJ plasma focus device

The radiation emission in a 2.2 kJ Mather-type dense plasma focus device is investigated using a five channel BPX65 PIN diode spectrometer. Estimated X-ray associated with the hollow anode without and with target in Argon gas medium is compared. At optimum conditions, the radiation emission from the system is found to be strongly influenced with target in hollow anode and the filling gas pressure. The maximum X-ray yield in 4π sr was obtained in case of hollow anode in argon gas medium with target 'Lead' due to interaction of electron beam. Results indicated that an appropriate design of hollow anode with target could enhance the radiation emission by more intense interaction of expected electron beam with target. The outcomes are helpful in designing a plasma focus with enhanced X-ray radiation with improved shot to shot reproducibility in plasma focus device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

Counter-facing plasma focus system as a repetitive and/or long-pulse high energy density plasma source

A plasma focus system composed of a pair of counter-facing coaxial plasma guns is proposed as a long-pulse and/or repetitive high energy density plasma source. A proof-of-concept experiment demonstrated that with an assist of breakdown and outer electrode connections, current sheets evolved into a configuration for stable plasma confinement at the center of the electrodes. The current sheets could successively compress and confine the high energy density plasma every half period of the discharge current, enabling highly repetitive light emissions in extreme ultraviolet region with time durations in at least ten microseconds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Studies of Ions Emission in a Small Plasma Focus Device of Hundreds of Joules

Ion beam emission in plasma focus (PF) discharges was originally investigated to explain the strong forward anisotropy observed in the neutron. Several properties of PF emitted deuteron beams have been measured, including their angular distributions and energy spectra in devices operating with energies from 1 kJ to 1 MJ. At present there is a growing interest in the development of very small PF devices operating under 1 kJ. As part of the characterization program of the very low energy PF devices (<1 kJ) developed at the Chilean Nuclear Energy Commission, the charges particle emission in hydrogen (H{sub 2}) and mixture (H{sub 2}+%Ar) are being studied. In order to obtain an estimation of the ions energy spectrum and ionization grade, by using time of flight method, a graphite collector system operating in the bias ion collector mode was constructed and it is being used. Preliminary results of the ion beams measurements in different experimental conditions, at a plasma focus device of 400 joules (PF-400 J) are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on neutron emission from 2.2 kJ plasma focus device

The neutron emission from a low energy (2.2 kJ) plasma focus device operated in deuterium medium has been investigated by employing photo-multiplier tube (PMT) and bubble dosimeter. The neutron emission is found to be pressure dependent and anisotropic in nature. In most cases of plasma focus shots, the PMT signal shows double pulses of neutron emission with different intensities and widths. An interesting relation between intensity of hard X-ray and neutron emission is also observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EBT2 dosimetry of x-rays produced by the electron beam from a Plasma Focus for medical applications

The electron beam emitted from the back of Plasma Focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A Plasma Focus device is being developed to this aim, to be utilized as an x-ray source. The electron beam is driven to impinge on 50 {mu}m brass foil, where conversion x-rays are generated. Measurements with gafchromic film are performed to analyse the attenuation of the x-rays beam and to predict the dose given to the culture cell in radiobiological experiments to follow.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the axial plasma shock in a table top plasma focus after the pinch and its possible application to testing materials for fusion reactors

The characterization of plasma bursts produced after the pinch phase in a plasma focus of hundreds of joules, using pulsed optical refractive techniques, is presented. A pulsed Nd-YAG laser at 532 nm and 8 ns FWHM pulse duration was used to obtain Schlieren images at different times of the plasma dynamics. The energy, interaction time with a target, and power flux of the plasma burst were assessed, providing useful information for the application of plasma focus devices for studying the effects of fusion-relevant pulses on material targets. In particular, it was found that damage factors on targets of the order of 10{sup 4} (W/cm{sup 2})s{sup 1/2} can be obtained with a small plasma focus operating at hundred joules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Plasma parameters and electron energy distribution functions in a magnetically focused plasma

Spatially resolved measurements of ion density, electron temperature, floating potential, and the electron energy distribution function (EEDF) are presented for a magnetically focused plasma. The measurements identify a central plasma column displaying Maxwellian EEDFs at an electron temperature of about 5 eV indicating the presence of a significant fraction of electrons in the inelastic energy range (energies above 15 eV). It is observed that the EEDF remains Maxwellian along the axis of the discharge with an increase in density, at constant electron temperature, observed in the region of highest magnetic field strength. Both electron density and temperature decrease at the plasma radial edge. Electron temperature isotherms measured in the downstream region are found to coincide with the magnetic field lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics of ion beam generated from a Mather type plasma focus device

Diagnostics of ion beam emission from a 3 kJ Mather-type plasma focus device have been performed for deuterium discharge at low pressure regime. Deuterium plasma focus was found to be optimum at pressure of 0.2 mbar. The energy spectrum and total number of ions per shot from the pulsed ion beam are determined by using biased ion collectors, Faraday cup, and solid state nuclear track detector CR-39. Average energy of the ion beam obtained is about 60 keV. Total number of the ions has been determined to be in the order of 10{sup 11} per shot. Solid state nuclear track detectors (SSNTD) CR39 are employed to measure the particles at all angular direction from end on (0°) to side on (90°). Particle tracks are registered by SSNTD at 30° to 90°, except the one at the end-on 0°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sahand Plasma Focus Emitted More Than 35 J in Yield Neon Soft X-ray

X-ray emission from neon plasma produced in Sahand Filippov type plasma focus device is investigated. Detecting system used in our experiments is a five channel pin diode detector. Soft X-ray emissions from neon gas at different charging voltages and working gas pressures are studied and optimum condition for production of soft X-ray for Sahand plasma focus facility is obtained. Results show that for every working pressure there is a charging voltage at which the average soft X-ray yield is maximum and this optimum charging voltage increases with increasing gas pressure. For 0.25, 0.50 and 0.75 Torr neon the optimum voltages are 12, 13 and 16 kV respectively. The highest average soft X-ray yields produced at 0.50 Torr which is about 35.87 ± 1.18 J. Also soft X-ray production decreased after a certain pressure which for our experiments is 0.50 Torr. The variation of relative hard X-ray yield with charging voltage and working gas pressure is also investigated. The results show that 0.50 Torr is also the best operating gas pressure for optimum hard X-ray production in Sahand Filippov type plasma focus device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of the energy transferred from the capacitor bank to the plasma in plasma focus systems

We consider the snowplow model to describe the axial phase of a plasma focus device. We show that, within this framework, the dynamics of a given system can be recovered at different energetic and geometric scales. Then, we consider two different criteria that would plausibly optimize the plasma focus performance. By solving the dynamics equations for the axial phase, we estimate the values of the parameters that do indeed satisfy the aforementioned criteria and compare those values with the corresponding ones attached to few practical devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlling the Neutron Yield from a Small Dense Plasma Focus using Deuterium-Inert Gas Mixtures

The dense plasma focus (DPF) is a well known source of neutrons when operating with deuterium. The DPF is demonstrated to scale from 10{sup 4} n/pulse at 40 kA to >10{sup 12} n/pulse at 2 MA by non-linear current scaling as described in [1], which is itself based on the simple yet elegant model developed by Lee [2]. In addition to the peak current, the gas pressure controls the neutron yield. Recent published results suggest that mixing 1-5% mass fractions of Krypton increase the neutron yield per pulse by more than 10x. In this paper we present results obtained by mixing deuterium with Helium, Neon and Argon in a 500 J dense plasma focus operating at 140 kA with a 600 ns rise time. The mass density was held constant in these experiments at the optimum (pure) deuterium mass density for producing neutrons. A typical neutron yield for a pure deuterium gas charge is 2x10{sup 6}{+-}15% n/pulse. Neutron yields in excess of 10{sup 7}{+-}10% n/pulse were observed with low mass fractions of inert gas. Time integrated optical images of the pinch, soft x-ray measurements and optical emission spectroscopy where used to examine the pinch in addition to the neutron yield monitor and the fast scintillation detector. Work supported by Domestic Nuclear Detection Office under contract HSHQDC-08-C-00020.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast-Neutron Source Based on Plasma-Focus Device

This paper describes investigations of neutrons produced by small plasma focus device PF-6 operating in the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland. Main parameters of neutron radiation have been measured by scintillation probe, and by activation technique. Current derivative probe has also been applied to measure dI/dt signal. Simultaneously neutron transport calculations have been carried out by Monte Carlo method. Finally, experimental measurements and numerical calculations have allowed concluding that plasma focus devices can be useful pulse neutron sources for different applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 10{sup 9} neutrons/pulse transportable pulsed D-D neutron source based on flexible head plasma focus unit

A 17 kJ transportable plasma focus (PF) device with flexible transmission lines is developed and is characterized. Six custom made capacitors are used for the capacitor bank (CB). The common high voltage plate of the CB is fixed to a centrally triggered spark gap switch. The output of the switch is coupled to the PF head through forty-eight 5 m long RG213 cables. The CB has a quarter time-period of 4 μs and an estimated current of 506 kA is delivered to the PF device at 17 kJ (60 μF, 24 kV) energy. The average neutron yield measured using silver activation detector in the radial direction is (7.1 ± 1.4) × 10{sup 8} neutrons/shot over 4π sr at 5 mbar optimum D{sub 2} pressure. The average neutron yield is more in the axial direction with an anisotropy factor of 1.33 ± 0.18. The average neutron energies estimated in the axial as well as in the radial directions are (2.90 ± 0.20) MeV and (2.58 ± 0.20) MeV, respectively. The flexibility of the PF head makes it useful for many applications where the source orientation and the location are important factors. The influence of electromagnetic interferences from the CB as well as from the spark gap on applications area can be avoided by putting a suitable barrier between the bank and the PF head.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray yield from NX2 plasma focus

The Lee model code is used to compute neon soft x-ray yield Y{sub sxr} for the NX2 plasma focus as a function of pressure. Comparison with measured Y{sub sxr} shows reasonable agreement in the Y{sub sxr} versus pressure curve, the absolute maximum yield as well as the optimum pressure. This gives confidence that the code gives a good representation of the neon plasma focus in terms of gross properties including speeds and trajectories and soft x-ray yields, despite its lack of modeling localized regions of higher densities and temperatures. Computed current curves versus pressure are presented and discussed particularly in terms of the dynamic resistance of the axial phase. Computed gross properties of the plasma focus including peak discharge current I{sub peak}, pinch current I{sub pinch}, minimum pinch radius r{sub min}, plasma density at the middle duration of pinch n{sub pinch}, and plasma temperature at middle duration of pinch T{sub pinch} are presented and the trends in variation of these are discussed to explain the peaking of Y{sub sxr} at optimum pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current sheath formation dynamics and structure for different insulator lengths of plasma focus device

The breakdown phase of the UNU-ICTP plasma focus (PF) device was successfully simulated using the electromagnetic particle in cell method. A clear uplift of the current sheath (CS) layer was observed near the insulator surface, accompanied with an exponential increase in the plasma density. Both phenomena were found to coincide with the surge in the electric current, which is indicative of voltage breakdown. Simulations performed on the device with different insulator lengths showed an increase in the fast ionization wave velocity with length. The voltage breakdown time was found to scale linearly with the insulator length. Different spatial profiles of the CS electron density, and the associated degree of uniformity, were found to vary with different insulator lengths. The ordering, according to the degree of uniformity, among insulator lengths of 19, 22, and 26 mm agreed with that in terms of soft X-ray radiation yield observed from experiments. This suggests a direct correlation between CS density homogeneity near breakdown and the radiation yield performance. These studies were performed with a linearly increasing voltage time profile as input to the PF device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗