Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA FOCUS DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Plasma Focus Device with a 2-MA Discharge Current as a Hard X-Ray Source

A device based on a pulsed current generator with capacitive energy storage loaded on a plasma focus (PF) chamber is described. The device provides a discharge current amplitude of up to 2 MA in the PF chamber at a stored energy in the capacitor bank of up to 150 kJ. The PF chamber is designed to study hard X-ray (HXR) emission. It has windows for output of HXR emission in the cathode direction, as well as a special insert for output of HXR emission into the anode cavity. A study of operation of the chamber as a part of the setup with the use of various X-ray targets on the anode has been carried out. At a discharge current of 1.5MA, an HXR pulse with an average duration of 16 ns and energy spectrum from 10 to 200 keV, which provides an absorbed dose in the irradiated samples on the order of 1 Sv, is generated in the PF chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulations of plasma heating caused by the coalescence of multiple current loops in a proton-boron fusion plasma

Two dimensional particle-in-cell simulations of a dense plasma focus were performed to investigate a plasma heating process caused by the coalescence of multiple current loops in a proton-boron-electron plasma. Recently, it was reported that the electric field produced during the coalescence of two current loops in a proton-boron-electron plasma heats up all plasma species; proton-boron nuclear fusion may therefore be achievable using a dense plasma focus device. Based on this work, the coalescence process for four and eight current loops was investigated. It was found that the return current plays an important role in both the current pinch and the plasma heating. The coalescence of four current loops led to the breakup of the return current from the pinched plasma, resulting in plasma heating. For the coalescence of eight current loops, the plasma was confined by the pinch but the plasma heating was smaller than the two and four loop cases. Therefore the heating associated with current loop coalescence depends on the number of initial current loops. These results are useful for understanding the coalescence of multiple current loops in a proton-boron-electron plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of plasma jets in a table top plasma focus discharge

In the last years, medium size Z-pinch experiments operating at tens of kJ are being used to create supersonic plasma jets. Those experiments are produced with wire arrays and radial foils, and they are conducted in generators based on water-filled transmission lines. Also plasma jets have been observed in small X-pinch experiments operating at 1 kJ. In this work, observations of plasma jets produced in a table top plasma focus device by means of optical and digital interferometry are shown. The device was operated at only ∼70 J, achieving 50 kA in 150 ns. The plasma jets were observed after the pinch, in the region close and on the anode, along the axis. The electron density measured from the jets is in the range 10{sup 24}–10{sup 25 }m{sup −3}. From two consecutive plasma images separated 18 ns, the axial jet velocity was measured in the order of 4 × 10{sup 4 }m/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentary structures in dense plasma focus: Current filaments or vortex filaments?

Recent observations of an azimuthally distributed array of sub-millimeter size sources of fusion protons and correlation between extreme ultraviolet (XUV) images of filaments with neutron yield in PF-1000 plasma focus have re-kindled interest in their significance. These filaments have been described variously in literature as current filaments and vortex filaments, with very little experimental evidence in support of either nomenclature. This paper provides, for the first time, experimental observations of filaments on a table-top plasma focus device using three techniques: framing photography of visible self-luminosity from the plasma, schlieren photography, and interferometry. Quantitative evaluation of density profile of filaments from interferometry reveals that their radius closely agrees with the collision-less ion skin depth. This is a signature of relaxed state of a Hall fluid, which has significant mass flow with equipartition between kinetic and magnetic energy, supporting the “vortex filament” description. This interpretation is consistent with empirical evidence of an efficient energy concentration mechanism inferred from nuclear reaction yields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by {approx_equal}1 MJ plasma focus

The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of {approx_equal}1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Beam And Plasma Jet Generated By A 3 kJ Plasma Focus

The plasma focus device is well known as a copious source of X-ray, neutrons, ion and electron beams. In this work, the characteristics of energetic ion beam emission in a 3 kJ Mather-type plasma focus is studied. The plasma focus system is operated at low pressure with argon as the working gas. The objective of the project is to obtain the argon ion beam and the plasma jet. The ion beam and plasma jet are used for material processing. In order to investigate the effect of the ion beam and plasma jet, crystalline silicon substrates are placed above the anode. Samples obtained after irradiation with the plasma focus discharge are analyzed by using the Scanning electron microscopy (SEM) and Energy Dispersive X-ray spectroscopy (EDX).

36 MATERIALS SCIENCE↗

EBT2 dosimetry of x-rays produced by the electron beam from a Plasma Focus for medical applications

The electron beam emitted from the back of Plasma Focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A Plasma Focus device is being developed to this aim, to be utilized as an x-ray source. The electron beam is driven to impinge on 50 {mu}m brass foil, where conversion x-rays are generated. Measurements with gafchromic film are performed to analyse the attenuation of the x-rays beam and to predict the dose given to the culture cell in radiobiological experiments to follow.

61 RADIATION PROTECTION AND DOSIMETRY↗

A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus

The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of polarity on beam and plasma target formation in a dense plasma focus

Dense plasma focus (DPF) devices are conventionally operated with a polarity such that the inner electrode (IE) is the anode. It has been found that interchanging the polarity of the electrodes (i.e., IE as the cathode) can cause an order of magnitude decrease in the neutron yield. This polarity riddle has previously been studied empirically through several experiments and is yet not well understood. Herein, we have performed kinetic simulations using the particle-in-cell modeling to investigate the problem. This is the first time that both polarities have been studied with simulations in great detail. In our simulations, we have modeled the entire beam and plasma target formation processes, but we did not consider differences in break-down conditions caused by the two polarities. We have found that when using reverse polarity ions are still accelerated and, in fact, attain similar energy spectra as in the standard polarity case. The difference is that the fields are flipped and thus ions are accelerated in the opposite direction. So, in the reverse polarity case, the majority of the “plasma target” (formed by the imploding plasma) is in the opposite direction of the beam, and thus, the beam hits the IE and produces few neutrons. With a better inner electrode configuration, reverse polarity is able to create a high-quality ion beam as well as a high-density target. Both can be comparable to that generated by standard polarity. Furthermore, we will show that it is easier to add an additional solid catcher target to a DPF device with reverse polarity, potentially enabling it to generate more neutrons than standard polarity.

Plasma sheaths↗

Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Runaway electrons as a source of impurity and reduced fusion yield in the dense plasma focus

Impurities produced by the vaporization of metals in the electrodes may be a major cause of reduced fusion yields in high-current dense plasma focus devices. We propose here that a major, but hitherto-overlooked, cause of such impurities is vaporization by runaway electrons during the breakdown process at the beginning of the current pulse. This process is sufficient to account for the large amount of erosion observed in many dense plasma focus devices on the anode very near to the insulator. The erosion is expected to become worse with lower pressures, typical of machines with large electrode radii, and would explain the plateauing of fusion yield observed in such machines at higher peak currents. Such runaway electron vaporization can be eliminated by the proper choice of electrode material, by reducing electrode radii and thus increasing fill gas pressure, or by using pre-ionization to eliminate the large fields that create runaway electrons. If these steps are combined with monolithic electrodes to eliminate arcing erosion, large reductions in impurities and large increases in fusion yield may be obtained, as the I{sup 4} scaling is extended to higher currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sahand Plasma Focus Emitted More Than 35 J in Yield Neon Soft X-ray

X-ray emission from neon plasma produced in Sahand Filippov type plasma focus device is investigated. Detecting system used in our experiments is a five channel pin diode detector. Soft X-ray emissions from neon gas at different charging voltages and working gas pressures are studied and optimum condition for production of soft X-ray for Sahand plasma focus facility is obtained. Results show that for every working pressure there is a charging voltage at which the average soft X-ray yield is maximum and this optimum charging voltage increases with increasing gas pressure. For 0.25, 0.50 and 0.75 Torr neon the optimum voltages are 12, 13 and 16 kV respectively. The highest average soft X-ray yields produced at 0.50 Torr which is about 35.87 ± 1.18 J. Also soft X-ray production decreased after a certain pressure which for our experiments is 0.50 Torr. The variation of relative hard X-ray yield with charging voltage and working gas pressure is also investigated. The results show that 0.50 Torr is also the best operating gas pressure for optimum hard X-ray production in Sahand Filippov type plasma focus device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on electron beam in a low energy plasma focus

Electron beam emission was investigated in a low energy plasma focus device (2.2 kJ) using copper hollow anode. Faraday cup was used to estimate the energy of the electron beam. XR100CR X-ray spectrometer was used to explore the impact of the electron beam on the target observed from top-on and side-on position. Experiments were carried out at optimized pressure of argon gas. The impact of electron beam is exceptionally notable with two different approaches using lead target inside hollow anode in our plasma focus device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the Al wire placed in the anode axis on the transformation of the deuterium plasma column in the plasma focus discharge

In this paper, we describe the influence of an Al wire of 270 μm in diameter placed along the anode axis on the transformation of the deuterium pinch column in a megaampere (MA) plasma focus device. The evolution of the pinched column and of the wire corona was investigated by means of the multiframe interferometry, neutron and X-ray diagnostics. The wire corona did not influence considerably on the evolution of dense plasma structures and neutron production, but it increased the plasma density and consequently, the currents around its surface. The distribution of the closed internal currents (ranging hundreds of kA) and associated magnetic fields amounting to 5 T were also estimated in the dense plasma column and in plasmoidal structures at the near-equilibrium state. The description is based on the balance of the plasma pressure and the pressure of the internal poloidal and toroidal current components compressed by the external pinched column. The dominant number of fusion deuterium-deuterium (D-D) neutrons is produced during the evolution of instabilities, when the uninterrupted wire corona (containing deuterium) connects the dense structures of the pinch, and it did not allow the formation of a constriction of the sub-millimeter diameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentary structure of plasma produced by compression of puffing deuterium by deuterium or neon plasma sheath on plasma-focus discharge

The present experiments were performed on the PF-1000 plasma focus device at a current of 2 MA with the deuterium injected from the gas-puff placed in the axis of the anode face. The XUV frames showed, in contrast with the interferograms, the fine structure: filaments and spots up to 1 mm diameter. In the deuterium filling, the short filaments are registered mainly in the region of the internal plasmoidal structures and their number correlates with the intensity of neutron production. The longer filamentary structure was recorded close to the anode after the constriction decay. The long curve-like filaments with spots were registered in the big bubble formed after the pinch phase in the head of the umbrella shape of the plasma sheath. Filaments can indicate the filamentary structure of the current in the pinch. Together with the filaments, small compact balls a few mm in diameter were registered by both interferometry and XUV frame pictures. They emerge out of the dense column and their life-time can be greater than hundreds of ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗