Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Efficiency Plastic Scintillator Detector with Wave-Length Shifting Fiber Readout for the GLAST Large Area Telescope

This paper describes the design and performance studies of the scintillator tile detectors for the Anti-Coincidence Detector (ACD) of the Large Area Telescope (LAT) on the Gamma ray Large Area Space Telescope (GLAST), scheduled for launch in early 2008. The scintillator tile detectors utilize wavelength shifting fibers and have dual photomultiplier tube (PMT) readout. The design requires highly efficient and uniform detection of singly charged relativistic particles over the tile area and must meet all requirements for a launch, as well as operation in a space environment. We present here the design of three basic types of tiles used in the ACD, ranging in size from approx.450 sq cm to approx.2500 sq cm, all 1 cm thick, with different shapes, and with photoelectron yield of approx. 20 photoelectrons per minimum ionizing particle (mip) at normal tile incidence, uniform over the tile area. Some tiles require flexible clear fiber cables up to 1.5 m long to deliver scintillator light to remotely located PMT.

Moiseev, A. A.↗

Calibration of the neutron detectors for the cluster fusion experiment on the Texas Petawatt Laser

Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source and 2.45 MeV fusion neutrons generated from laser-cluster interaction were used as neutron sources. The scintillation detectors were calibrated such that they can detect up to 10{sup 8} DD fusion neutrons per shot in current mode under high electromagnetic pulse environments. Indium activation detectors successfully measured neutron yields as low as 10{sup 4} per shot and up to 10{sup 11} neutrons. The use of a Cf-252 neutron source allowed cross calibration of CR-39 and indium activation detectors at high neutron yields ({approx}10{sup 11}). The CR-39 detectors provided consistent measurements of the total neutron yield of Cf-252 when a modified detection efficiency of 4.6 Multiplication-Sign 10{sup -4} was used. The combined use of all three detectors allowed for a detection range of 10{sup 4} to 10{sup 11} neutrons per shot.

43 PARTICLE ACCELERATORS↗

Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications

A clinical prototype of a scintillating fiber dosimeter array for quality assurance applications is presented. The array consists of a linear array of 29 plastic scintillation detectors embedded in a water-equivalent plastic sheet coupled to optical fibers used to guide optical photons to a charge coupled device (CCD) camera. The CCD is packaged in a light-tight, radiation-shielded housing designed for convenient transport. A custom designed connector is used to ensure reproducible mechanical positioning of the optical fibers relative to the CCD. Profile and depth dose characterization measurements are presented and show that the prototype provides excellent dose measurement reproducibility ({+-}0.8%) in-field and good accuracy ({+-}1.6% maximum deviation) relative to the dose measured with an IC10 ionization chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hardness of Scintillation Detectors Based on Organic Plastic Scintillators and Optical Fibers

Scintillation detectors (SD) based on organic plastic scintillators and optical fibers are basic detectors at all modern accelerators and in astrophysics and neutrino physics experiments. In recent years, interest in SD has significantly increased due to the upcoming major upgrade of the LHC and the construction of new accelerators NICA, FAIR, FCC, etc. At the same time, requirements on the stability and reliability of SD operation under new conditions have become stricter, and their fulfillment largely depends on radiation hardness of scintillators, optical fibers, and photodetectors. The review presents the results of the radiation hardness investigations of various scintillators, optical fibers (scintillating, as well as wavelength-shifting and clear), and optical glues used to increase light collection from scintillators by fibers. The influence of various factors (dose, dose rate, type of radiation, scintillator materials, and fluors) on light output, light collection, and transmittance of the irradiated materials and their recovery is considered. Aging of scintillators caused by environmental effects (temperature, humidity) irrespective of radiation is also briefly considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Line-shape analysis of Doppler-broadened {gamma} lines following the {beta} decay of {sup 11}Li

The {beta} decay of {sup 11}Li is studied at the TRIUMF Isotope Separation and Acceleration (ISAC) facility using the 8{pi} {gamma}-ray spectrometer coupled with an inner array of 20 plastic scintillators for {beta} detection. Doppler-broadened line shapes resulting from the decay of the excited states in {sup 10}Be populated by {beta}-delayed one-neutron emission are analyzed using Monte Carlo simulations. New {beta}-delayed neutron decay branches are shown to contribute to the complex decay of {sup 11}Li. The half-lives of all but one bound excited state in {sup 10}Be are also deduced from this work. Among them, the half-life of the 2{sup -} state in {sup 10}Be is shown to be much shorter than previously thought, yielding a new experimental B(E1) now well within the range of theoretical predictions and providing further evidence that the 2{sup -} state in {sup 10}Be is an excited halo state. The nature of the 8.82-MeV state in {sup 11}Be and its decay paths to excited states in {sup 10}Be are found to be consistent with the {beta} decay of the core proceeding through this particular state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plastic scintillators modifications for a selective radiation detection

Recent developments of plastic scintillators are reviewed, from January 2000 to June 2015. All examples are distributed into the main application, i.e. how the plastic scintillator was modified to enhance the detection towards a given radiation particle. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect-resistant plastic scintillation radiation detector compositions and fabrication methods

Scintillating plastics resistant to crazing and fogging, methods of making and using the same are disclosed. The scintillating plastics include: one or more primary polymers present in an amount ranging from about 40 wt % to about 95 wt %; one or more secondary polymers present in an amount ranging from about 1 wt % to about 60 wt %; and one or more fluors present in an amount ranging from about 0.1 wt % to about 50 wt %. Methods of making such plastics include: creating a homogenous mixture of precursor materials including primary polymer, secondary polymer, and fluor in the amounts set forth above; and polymerizing the homogenous mixture. Methods of using such plastics include: exposing the scintillating plastic to one or more extreme environmental conditions for a predetermined amount of time without generating crazing or fogging within the scintillating plastic. Various additional features and specific embodiments of these inventive concepts are also disclosed.

36 MATERIALS SCIENCE↗

Current status on plastic scintillators modifications

Recent developments of plastic scintillators are reviewed, from 2000 to March 2015. All examples are distributed into the main purpose, i.e. the nature of the radionuclide provided with the scope of detection of various radiation particles. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a Fast Neutron Detection System With Large Angular Coverage and Granularity for Physics Studies and Applications

This work presents a review of fast neutron detection, with an emphasis on the use of plastic scintillating materials. We developed neutron detectors both at the Instituto de Fisica, UNAM and at the Tandem Accelerator Laboratory, ININ. We will describe in detail our detectors and their characteristics. We will present some results on the development of a large position-sensitive neutron detector in two dimensions. In particular, we present a phenomenological formula that describes the complex dependence of the amount of light reaching a detector as a function of the position of the light source within the scintillating material. First measurements with a very small number of detectors are presented and show encouraging results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a New Clearance Monitor for Exemption of NPP Radioactive Wastes and its Performance Test - 17200

In nuclear power plants, it is common practice to clear radioactive wastes for free release by using clearance monitor with plastic scintillation detectors so as to reduce disposal costs. These monitors are possible in part thanks to the excellent detection levels achievable with high energy and high yield photons emitted from contaminants such as Cs-137 and Co-60. However, it is difficult for the monitors to separate Naturally Occurring Radioactive Materials (NORM) from the radioactive wastes because the plastic scintillation detectors have poor resolution compared to NaI or HPGe detectors. KHNP has developed a new clearance monitor for determining whether or not the radioactivity level of metal scraps satisfies regulatory criteria. The monitor is composed of 12 large area plastic scintillation detectors and 3 NaI scintillation detectors. The measuring chamber is surrounded by a 5 cm-thick lead shield with chamber dimensions of 1.5 m x 1.0 m x 1.0 m. Its algorithm has a function of measuring total gamma activity while analyzing gamma nuclides and identifying 27 hotspots in radioactive wastes. The detection limit of this system, according to the MCNP simulation, was determined to be about 45 Bq for Co-60 and 78 Bq for Cs-137 with the condition of an empty chamber and measuring time of 1 minute. We evaluated the self - shielding effect of waste for background correction factor and waste height (volume in the chamber) correction factor. We also tested its MDA, location determination of hot-spots, temperature compensation function and convenience of operation. In the future, we will plan to install it at a nuclear site for more tests including evaluating its durability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of influence of plastic scintillators thicknesses to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources

The Nuclear and Energy Research Institute - IPEN, offers post-graduate programs, namely: Nuclear Technology - Applications (TNA), Nuclear Technology - Materials (TNM), Nuclear Technology - Reactors (TNR). The Institute programs mission is to form expert technicians, physicists and engineers with a strong knowledge in their discipline to work in the nuclear area. The course: 'Theoretical Fundamentals and Practices of the Instrumentation used in Nuclear Data Acquisition' covers the use of laboratory nuclear instrumentation and the accomplishment of experiments to obtain nuclear parameters. One of these experimental exercises is object of this work: 'Study of influence of plastic scintillators to detect Beta particles and Gamma radiation by means of spectral analysis of {sup 90}Sr, {sup 90}Y and {sup 137}Cs sources'. The use of scintillators plastic for the detection has the advantage of low cost, high mechanical strength, is not hygroscopic and can be manufactured in large volumes. This work aims to present the analysis of relative efficiency of detection of plastic scintillators of various thicknesses for beta particles and gamma radiation by the spectrum of {sup 137}Cs and {sup 90}Sr. Due to lack of resolution of the detectors plastic scintillators we worked with relative efficiency. The evaluation was done by reading deposited energy, using the software MAESTRO, for each detector thickness. For beta particles was observed an ideal thickness around 3 mm and the better photon efficiency was observed with increasing the thickness of the detector. The present experiment does not intend to establish a new technique for this subject: it solely aims student's practical exercises in nuclear properties of elements and detectors being part of the nuclear experimental course. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

MINERνA charged current inclusive analysis

MINERνA is a few-GeV neutrino scattering experiment that has been taking data in the NuMI beam line at Fermilab since November 2009. The experiment will provide important inputs, both in support of neutrino oscillation searches and as a pure weak probe of the nuclear medium. For this, MINERvA employs a fine-grained detector, with an eight ton active target region composed of plastic scintillator and a suite of nuclear targets composed of helium, carbon, iron, lead and water placed upstream of the active region. We will describe the current status of the charged current inclusive analysis in plastic scintillator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstruction of Time-Resolved Neutron Energy Spectra in Z-Pinch Experiments Using Time-of-flight Method

We present the reconstruction of neutron energy spectra from time-of-flight signals. This technique is useful in experiments with the time of neutron production in the range of about tens or hundreds of nanoseconds. The neutron signals were obtained by a common hard X-ray and neutron fast plastic scintillation detectors. The reconstruction is based on the Monte Carlo method which has been improved by simultaneous usage of neutron detectors placed on two opposite sides from the neutron source. Although the reconstruction from detectors placed on two opposite sides is more difficult and a little bit inaccurate (it followed from several presumptions during the inclusion of both sides of detection), there are some advantages. The most important advantage is smaller influence of scattered neutrons on the reconstruction. Finally, we describe the estimation of the error of this reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗