Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUTONIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SpecFIDLER User Manual: Software Version 2.4.0

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.5.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.3.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAP-27/ALSEP power subsystem used in the Apollo program.

The Apollo Lunar Surface Experiments Package (ALSEP) measures lunar physical and environmental characteristics and transmits the data to receiving stations on earth. The data are used to derive information on the composition and structure of the moon. The electrical power subsystem generates and conditions all the electrical power for operations of the ALSEP system. The power source for the ALSEP is the Systems for Nuclear Auxiliary Power (SNAP) Radioisotope Thermoelectric Generator (RTG). The generator produces electricity by thermoelectric conversion. The radioactive isotope plutonium 238 is used as the energy source for the SNAP-27. By April 1, 1970, the SNAP-27 RTG had produced more than 230 kWh of continuous and stable power for the ALSEP.-

Remini, W. C.↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear data uncertainty quantification for the nuclide inventory of a Calvert Cliffs spent fuel sample

The impact of nuclear data cross section uncertainties and covariance matrices on the nuclide vector of spent nuclear fuel was investigated; This exercise was carried out for the Calvert Cliffs fuel assembly D047 benchmark available in the SFCOMPO database. Sample P irradiated in rod MKP109 for 4 cycles up to a burnup of approximately 44 GWd/MTU was selected for the analysis. Nuclear data uncertainties were taken from the most recent libraries released by evaluation projects JEFF, ENDF/B and JENDL, and were propagated using the SANDY code via a stochastic sampling approach. This paper provides a quantification of the uncertainty on the concentration of several actinides and fission products relevant for spent fuel management. Uncertainties generally below 5 % were predicted for the concentrations of most of the uranium, neptunium and plutonium isotopes relevant for SNF applications. Curium isotopes carry larger uncertainties that might exceed 10 %. The contribution of cross section uncertainties on the concentrations of fission products was found to be marginal with the exception of a few nuclides. These results can be significantly affected by the lack of evaluated covariance matrices for the capture cross section of several fission products. Burnup tracers such as {sup 148}Nd and {sup 137}Cs have negligible uncertainties because of the power normalisation imposed in every stochastic calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRAM v.7.1

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr3) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

07 ISOTOPE AND RADIATION SOURCES↗

Some neutron and gamma radiation characteristics of plutonium cermet fuel for isotopic power sources

Gamma and neutron measurements on various types of plutonium sources are presented in order to show the effects of O-17, O-18 F-19, Pu-236, age of the fuel, and size of the source on the gamma and neutron spectra. Analysis of the radiation measurements shows that fluorine is the main contributor to the neutron yields from present plutonium-molybdenum cermet fuel, while both fluorine and Pu-236 daughters contribute significantly to the gamma ray intensities.

Neff, R. A.↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma radiation characteristics of plutonium dioxide fuel

Investigation of plutonium dioxide as an isotopic fuel for Radioisotope Thermoelectric Generators yielded the isotopic composition of production-grade plutonium dioxide fuel, sources of gamma radiation produced by plutonium isotopes, and the gamma flux at the surface.

Gingo, P. J.↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Recommended Updates to Solubility Controls for Modeling Leaching of Technetium, Uranium, Neptunium, Plutonium, and Iodine from the Residual Waste Layer of Closed Savannah River Site High Level Waste Tanks

The objective of this report is to relate waste leaching experiments by the Savannah River National Laboratory (SRNL) to performance assessment modeling of release of several radionuclides from residual waste in closed high-level waste tanks. SRNL leached residual waste from Tanks 18F and 12H with solutions simulating the modeled evolution of pore fluids in residual waste layers of closed tanks through various stages of grout degradation. Tc-99, uranium isotopes, Np-237, plutonium isotopes, and I-129 were analyzed in the leachate multiple times over 90 days.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Elucidating the Radiation-Induced Redox Chemistry of Plutonium Under Used Nuclear Fuel Reprocessing Conditions

Plutonium plays a critical role in the development of sustainable nuclear fuel cycles, and yet, our fundamental understanding of this element’s inherent radiation-induced redox chemistry and associated impacts on nuclear fuel cycle technologies is limited. Unanticipated changes in oxidation state distribution can influence the speciation and transport of plutonium in a given process. Control of these parameters is especially important for used nuclear fuel reprocessing technologies, wherein the separation and recovery of plutonium is typically achieved by the selective formation, maintenance, and complexation of specific oxidation states. Furthermore, plutonium’s inherent radiation-induced redox chemistry has the capacity to influence the radiolytic behavior of its complexes, the longevity of which are critical in the design of efficient and cost-effective advanced reprocessing technologies. These radiation-induced processes are unavoidable under fuel cycle conditions owing to the inherency of ionizing radiation fields to the decay of plutonium’s isotopes and to the various other radioisotopes generated by nuclear fission and neutron-capture process and the subsequent radioactive decay of their products. As such, mechanistically understanding the response of plutonium’s multiple oxidation states to multi-component ionizing radiation fields is essential for predicting the behavior of this critical element under used nuclear fuel reprocessing conditions. Here, through a combination of time-resolved (electron pulse) and steady-state (alpha and gamma) irradiation experiments complemented by quantitative, multiscale modeling calculations, we present advances in our understanding of radiation-induced plutonium redox chemistry!

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Station 11: An Overview of Plutonium

Sitting between neptunium (atomic number 93) and americium (atomic number 95) is the element plutonium (atomic number 94). Of all the elements on the periodic table, plutonium exhibits some of the strangest characteristics, some of which continue to baffle scientists to this day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗