Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUTONIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.3.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclide inventory validation: radiochemical assay data quality and modeling challenges in benchmark models development

Oak Ridge National Laboratory is conducting radiochemical assay experiments, using high-precision analytical protocols validated with a comprehensive quality assurance plan, to expand the nuclide inventory validation basis for high burnup spent nuclear fuel. Preliminary measurement data for key actinides and fission products in two pressurized water reactor spent fuel samples are being used to investigate the impact of measurement data uncertainty on the sample burnup estimation. These measurement data are also being used to examine the impact of assumptions applied when developing best-estimate computational models to simulate fuel irradiation history. The simulations are being performed using depletion capabilities in the SCALE code system. Comparison of calculated and measured nuclide concentrations shows good agreement for the considered nuclides. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear data uncertainty quantification for the nuclide inventory of a Calvert Cliffs spent fuel sample

The impact of nuclear data cross section uncertainties and covariance matrices on the nuclide vector of spent nuclear fuel was investigated; This exercise was carried out for the Calvert Cliffs fuel assembly D047 benchmark available in the SFCOMPO database. Sample P irradiated in rod MKP109 for 4 cycles up to a burnup of approximately 44 GWd/MTU was selected for the analysis. Nuclear data uncertainties were taken from the most recent libraries released by evaluation projects JEFF, ENDF/B and JENDL, and were propagated using the SANDY code via a stochastic sampling approach. This paper provides a quantification of the uncertainty on the concentration of several actinides and fission products relevant for spent fuel management. Uncertainties generally below 5 % were predicted for the concentrations of most of the uranium, neptunium and plutonium isotopes relevant for SNF applications. Curium isotopes carry larger uncertainties that might exceed 10 %. The contribution of cross section uncertainties on the concentrations of fission products was found to be marginal with the exception of a few nuclides. These results can be significantly affected by the lack of evaluated covariance matrices for the capture cross section of several fission products. Burnup tracers such as {sup 148}Nd and {sup 137}Cs have negligible uncertainties because of the power normalisation imposed in every stochastic calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRAM v.7.1

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr3) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

07 ISOTOPE AND RADIATION SOURCES↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Recommended Updates to Solubility Controls for Modeling Leaching of Technetium, Uranium, Neptunium, Plutonium, and Iodine from the Residual Waste Layer of Closed Savannah River Site High Level Waste Tanks

The objective of this report is to relate waste leaching experiments by the Savannah River National Laboratory (SRNL) to performance assessment modeling of release of several radionuclides from residual waste in closed high-level waste tanks. SRNL leached residual waste from Tanks 18F and 12H with solutions simulating the modeled evolution of pore fluids in residual waste layers of closed tanks through various stages of grout degradation. Tc-99, uranium isotopes, Np-237, plutonium isotopes, and I-129 were analyzed in the leachate multiple times over 90 days.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Elucidating the Radiation-Induced Redox Chemistry of Plutonium Under Used Nuclear Fuel Reprocessing Conditions

Plutonium plays a critical role in the development of sustainable nuclear fuel cycles, and yet, our fundamental understanding of this element’s inherent radiation-induced redox chemistry and associated impacts on nuclear fuel cycle technologies is limited. Unanticipated changes in oxidation state distribution can influence the speciation and transport of plutonium in a given process. Control of these parameters is especially important for used nuclear fuel reprocessing technologies, wherein the separation and recovery of plutonium is typically achieved by the selective formation, maintenance, and complexation of specific oxidation states. Furthermore, plutonium’s inherent radiation-induced redox chemistry has the capacity to influence the radiolytic behavior of its complexes, the longevity of which are critical in the design of efficient and cost-effective advanced reprocessing technologies. These radiation-induced processes are unavoidable under fuel cycle conditions owing to the inherency of ionizing radiation fields to the decay of plutonium’s isotopes and to the various other radioisotopes generated by nuclear fission and neutron-capture process and the subsequent radioactive decay of their products. As such, mechanistically understanding the response of plutonium’s multiple oxidation states to multi-component ionizing radiation fields is essential for predicting the behavior of this critical element under used nuclear fuel reprocessing conditions. Here, through a combination of time-resolved (electron pulse) and steady-state (alpha and gamma) irradiation experiments complemented by quantitative, multiscale modeling calculations, we present advances in our understanding of radiation-induced plutonium redox chemistry!

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Station 11: An Overview of Plutonium

Sitting between neptunium (atomic number 93) and americium (atomic number 95) is the element plutonium (atomic number 94). Of all the elements on the periodic table, plutonium exhibits some of the strangest characteristics, some of which continue to baffle scientists to this day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recommended Representative Isotopic Compositions for Potential VTR Pu Supplies

This document recommends isotopic compositions to represent selected Pu supplies that might be made available for use in VTR driver fuel. These compositions are intended to be conservative representations suitable for determination of environmental impacts associated with use of the selected Pu supplies, but not upper bounds of all possible compositions. The selected Pu supplies under consideration are themselves representations of a more complicated set of possibilities, defined in a manner to allow efficient but conservative analysis of impacts. The source definitions to be considered are as follows: 1) Foreign sources of reactor-grade plutonium. This material would be provided as polished material in an oxide form and is assumed to be transported from Europe (France or England); 2) Domestic, non-weapon sources of plutonium such as unused FFTF fuel, Hanford metal (stored at SRS), and various oxides; 3) Domestic sources of weapons-grade plutonium, including metal from dismantled pits and otherwise excess to stockpile needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma and Decay Energy Spectroscopy Measurements of Trinitite

We report gamma-ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics techniques. Our gamma spectroscopy and DES measurements are compared to other published results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

IDB Loader

SAND2024-08428O The IDB Loader is a database designed to hold gamma spectra. IDB is a web-accessible database of reference gamma spectra for measuring uranium (U) and plutonium (Pu) isotopic composition. The database, developed by the International Atomic Energy Agency (IAEA), provides access to well-characterized groups of gamma spectra curated by international experts in gamma spectroscopy. It was created to promote sustainability and maintenance of software used to determine the isotopic abundances of U and Pu. The IDB Loader works by uploading one set of spectral data into an existing IDB. The Data Loader package includes documentation describing the IDB's table, the format of the spectral data, and a description of the loader program. The IDB is currently hosted by the IAEA at: https://nds.iaea.org/idb Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Schwartz, Steven↗

Summary of Analytical Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3 and Modeling Results for Cs Loading on CST

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. Some results from analysis of those samples have been previously reported. This report documents the remaining analyses of the in-tank batch contact samples as well as the results of ZAM (Zheng, Anthony, Miller) isotherm modeling performed for comparison to the measured results. Results of the additional analyses include analysis of the loading of other radionuclides besides 137 Cs on the crystalline silicotitanate (CST) contained within the in-tank batch contact test samples. Results from those analyses revealed the next highest contributor to the activity on the CST was 90 Sr with an average loading of 2.76E+08 dpm/g CST compared to 3.56E+10 dpm/g CST for the 137Cs. Isotopes of plutonium were also detected on the samples. ZAM modeling was performed using the measured composition of the Tank 10H Batch 3 qualification samples. The modeling predicted a maximum Cs loading approximately 2.2x higher than the measured result. This is a slightly lower ratio (expected/measured) compared to what was observed for the prior TCCR in-tank batch contact testing performed for Batches 1A and 2 where the ZAM results were 2.7-2.8x higher than the measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗