Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators

A tunable line filter polychromator for gas temperature measurements using laser Raman scattering

A proprietary laser line filter spectrograph (LLFS) was modified to test for improved remote measurement of atmospheric temperature by Raman spectroscopy of the rotational bands of N2 and O2. Both grating scan measurements with fixed PMT and polychromator image plane PMT scans with fixed grating setting were made using HeNe and Ar(+) lasers. The LLFS was found to have a laser line rejection ratio at 6A from the laser line and provides resolved rotational Raman spectral display at the polychromator exit plane. Spectral resolution is adequate to measure and correct for background in the Stokes spectrum. It is anticipated that this system should allow measurement of gas or atmospheric temperature to + or - 1 C.

Grossman, J. J.

Performance of photomultiplier tubes and sodium iodide scintillation detector systems

The performance of photomultiplier tubes (PMT's) and scintillation detector systems incorporating 50.8 by 1.27 cm NaI (T l) crystals was investigated to determine the characteristics of the photomultiplier tubes and optimize the detector geometry for the Burst and Transient Source Experiment on the Gamma Ray Observatory. Background information on performance characteristics of PMT's and NaI (T l) detectors is provided, procedures for measurement of relevant parameters are specified, and results of these measurements are presented.

Meegan, C. A.

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.

Lidar receivers for picosecond remote sensing

The lidars of picosecond resolution are an attractive tool for remote probing of some highly dynamic objects like sea subsurface waters, small-scale turbulences in the atmosphere, etc. The picosecond lasers are suitable illuminating sources, but the main restrictions are due to the lack of proper receiving methods, combining the both high temporal and amplitude resolution, good sensitivity, short integration time, and wide dynamic range. The methods for short pulse measurements are not suitable for picosecond lidars, operating at low level, with highly dynamic signals. The streak-cameras are of high cost, lower sensitivity, and lower dynamic range (approximately 10(exp 3)). Because of the background, the single quantum regime in photomultipliers (PMT) is ineffective. The sampling of highly dynamic optical signals with resolution less than or equal to 1ns is a serious problem, limiting the application of the high speed PMT-MCP (microchannel plate) in the picosecond lidar systems. The goal of this work is to describe the use of a new photodetection technique which combines the picosecond resolution with the high amplitude resolution, dynamic range, and sensitivity.

Stoyanov, D. V.

Partial Spreading of a Laser Beam into a Light Sheet by Shock Waves and Its Use as a Shock Detection Technique

It is observed that when a laser beam is allowed to fall on a shock surface at a grazing incidence, a small part of the beam spreads out in a thin, diverging sheet of light normal to the surface, and both upstream and downstream of the shock. The phenomenon is visualized by observing a cross section of the light sheet on a screen placed normal to the laser path after it touches a shock. The light sheet disappears when the beam is moved to any other locations where there is no shock or the beam pierces the shock surface, i.e., at a non-grazing incidence. The spread angle of the light sheet is considerably higher than the angle by which the beam may bend as it passes through the shock, which produces a small difference of refractive index. Various details indicate that the spread light is a result of diffraction of a small part of the laser beam by the shock whose thickness is nearly the same as that of the laser wavelength. Shocks formed in underexpanded free jets of fully expanded Mach numbers 1.4 to 1.8 are used for this experiment. The above optical phenomenon is used as the basis of a novel shock detection technique which depends on sensing the spread light using a photomultiplier tube (PMT). The locations of the shock surfaces in the underexpanded supersonic jet, obtained using this technique, match with those inferred from the Schlieren photographs and velocity measurements. Moreover, if the shock oscillates, a periodic PMT signal is obtained which provides information about the frequency and amplitude of shock motion.

Panda, J.

Linear operating region in the ozone dial photon counting system

Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

Andrawis, Madeleine

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani

Ground-Based Fabry-Perot Interferometry of the Terrestrial Nightglow with a Bare Charge-Coupled Device: Remote Field Site Deployment

The application of Fabry-Perot interferometers (FPIs) to the study of upper atmosphere thermodynamics has largely been restricted by the very low light levels in the terrestrial airglow as well as the limited range in wavelength of photomultiplier tube (PMT) technology. During the past decade, the development of the scientific grade charge-coupled device (CCD) has progressed to the stage in which this detector has become the logical replacement for the PMT. Small fast microcomputers have made it possible to "upgrade" our remote field sites with bare CCDs and not only retain the previous capabilities of the existing FPls but expand the data coverage in both temporal and wavelength domains. The problems encountered and the solutions applied to the deployment of a bare CCD, with data acquisition and image reduction techniques, are discussed. Sample geophysical data determined from the FPI fringe profiles are shown for our stations at Peach Mountain, Michigan, and Watson Lake, Yukon Territory.

Niciejewski, Rick

Rayleigh Scattering Diagnostic for Simultaneous Measurements of Dynamic Density and Velocity

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in turbulent flows. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer and recording information about the interference pattern with a multiple anode photomultiplier tube (PMT). An artificial neural network is used to process the signals from the PMT to recover the velocity time history, which is then used to calculate the velocity power spectrum. The technique is illustrated using simulated data. The results of an experiment to measure the velocity power spectrum in a low speed (100 rn/sec) flow are also presented.

Seasholtz, Richard G.

Laboratory Characterization and Modeling of a Near-Infrared Enhanced Photomultiplier Tube

The photon-starved channel for optical communications from deep space requires the development of detector technology that can achieve photon-counting sensitivities with high bandwidth. In this article, a near-infrared enhanced photomultiplier tube (PMT) with a quantum e.ciency of 0.08 at a 1.06- m wavelength is characterized in the laboratory. A Polya distribution model is used to compute the probability distribution function of the emitted secondary photoelectrons from the PMT. The model is compared with measured pulse-height distributions with reasonable agreement. The model accounts for realistic device parameters, such as the individual dynode stage gains and a shape parameter that is representative of the spatial uniformity of response across the photocathode and dynodes. Bit-error rate (BER) measurements also are presented for 4- and 8-pulse-position modulation (PPM) modulation schemes with data rates of 20 to 30 Mb/s. A BER of 10-2 is obtained for a mean of 8 detected photons.

Biswas, A.

The NASA Program Management Tool: A New Vision in Business Intelligence

This paper describes a novel approach to business intelligence and program management for large technology enterprises like the U.S. National Aeronautics and Space Administration (NASA). Two key distinctions of the approach are that 1) standard business documents are the user interface, and 2) a "schema-less" XML database enables flexible integration of technology information for use by both humans and machines in a highly dynamic environment. The implementation utilizes patent-pending NASA software called the NASA Program Management Tool (PMT) and its underlying "schema-less" XML database called Netmark. Initial benefits of PMT include elimination of discrepancies between business documents that use the same information and "paperwork reduction" for program and project management in the form of reducing the effort required to understand standard reporting requirements and to comply with those reporting requirements. We project that the underlying approach to business intelligence will enable significant benefits in the timeliness, integrity and depth of business information available to decision makers on all organizational levels.

Maluf, David A.

Estimating Random Errors Due to Shot Noise in Backscatter Lidar Observations

In this paper, we discuss the estimation of random errors due to shot noise in backscatter lidar observations that use either photomultiplier tube (PMT) or avalanche photodiode (APD) detectors. The statistical characteristics of photodetection are reviewed, and photon count distributions of solar background signals and laser backscatter signals are examined using airborne lidar observations at 532 nm using a photon-counting mode APD. Both distributions appear to be Poisson, indicating that the arrival at the photodetector of photons for these signals is a Poisson stochastic process. For Poisson-distributed signals, a proportional, one-to-one relationship is known to exist between the mean of a distribution and its variance. Although the multiplied photocurrent no longer follows a strict Poisson distribution in analog-mode APD and PMT detectors, the proportionality still exists between the mean and the variance of the multiplied photocurrent. We make use of this relationship by introducing the noise scale factor (NSF), which quantifies the constant of proportionality that exists between the root-mean-square of the random noise in a measurement and the square root of the mean signal. Using the NSF to estimate random errors in lidar measurements due to shot noise provides a significant advantage over the conventional error estimation techniques, in that with the NSF uncertainties can be reliably calculated from/for a single data sample. Methods for evaluating the NSF are presented. Algorithms to compute the NSF are developed for the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) lidar and tested using data from the Lidar In-space Technology Experiment (LITE). OCIS Codes:

Liu, Zhaoyan

High Efficiency Plastic Scintillator Detector with Wave-Length Shifting Fiber Readout for the GLAST Large Area Telescope

This paper describes the design and performance studies of the scintillator tile detectors for the Anti-Coincidence Detector (ACD) of the Large Area Telescope (LAT) on the Gamma ray Large Area Space Telescope (GLAST), scheduled for launch in early 2008. The scintillator tile detectors utilize wavelength shifting fibers and have dual photomultiplier tube (PMT) readout. The design requires highly efficient and uniform detection of singly charged relativistic particles over the tile area and must meet all requirements for a launch, as well as operation in a space environment. We present here the design of three basic types of tiles used in the ACD, ranging in size from approx.450 sq cm to approx.2500 sq cm, all 1 cm thick, with different shapes, and with photoelectron yield of approx. 20 photoelectrons per minimum ionizing particle (mip) at normal tile incidence, uniform over the tile area. Some tiles require flexible clear fiber cables up to 1.5 m long to deliver scintillator light to remotely located PMT.

Moiseev, A. A.

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.

Gated-Dynode Photomultiplier Tube Assembly for the Boronated Scintillator Detector of the ISS-CREAM Experiment

We present the design of a four-photomultiplier tube (PMT) assembly for measuring light generation in theBoronated Scintillator Detector (BSD) of the Cosmic Ray Energetics And Mass experiment for the InternationalSpace Station (ISS-CREAM). The light produced in the scintillator includes a contribution from the captureof thermalized neutrons produced in cosmic ray interactions, as well as delayed fluorescence, in the range ofseveral microseconds following the incident cosmic ray impact. The BSD is held in an insensitive state until acosmic-ray trigger causes a rapid turn on of the PMTs to detect late light signals, several microseconds afterthe trigger. The design includes two pulsed high-voltage supplies, which serve to gate the first two dynodesof the Hamamatsu R1924A PMTs used in the assembly. When the dynode gates are held in the "off" state,this scheme is shown to suppress >105 photons from injection into the tube's multiplier stage, while beingcapable of rapid switching into a stable operating mode in less than 1 s. This mitigates any backgroundsfrom afterpulsing that might otherwise be present in the PMT response following the cosmic ray incidence.

Anderson, T.

Organic Matter in Itokawa Particles

The first Hayabusa mission returned samples from the near-Earth S-type asteroid 25143 Itokawa to Earth in 2010[1]. Although Itokawa has a lithology related to ordinary chondrites(OCs) that typically have low organic contents, several Itokawa particles were found to contain organic matter (OM)[2-5]. However, there was not an explicit conclusion to the origin of the observed OMin these early studies. We have extended our search for OM into other Itokawa grains. Here, we report extraterrestrial OM (macromolecular carbon and amino acids) observed in six Itokawa particles(including a category1 particle: RA-QD02-0162[#62; also nicknamed “Amazon”],and five category3 carbon-rich particles:RA-QD02-0012[#12], RA-QD02-0078[#78], RB-CV-0029[#29], RB-CV-0080 [#80] and RB-QD04-0052[#52]).All allocated Itokawa samples were initially analysed by spot and point-by-point mapping Raman spectroscopic analysis at the Open University, UK. Amazon was then transferred and mounted into indium on an aluminium stub, which was studied with a NanoSIMS 50L ion microprobe for its H,C,N isotopic compositions. The rest of the samples were mounted in sterile gold foils, and the amino acid contents of their acid hydrolysed hot water extracts were obtained with a liquid chromatography with tandem fluorescence and accurate mass detection at NASA Goddard Space Flight Center, USA. Based on the observation of the Raman parameters(e.g. the peak locations and widths of the defect (D) and graphite (G) bands)[6], a significant variety of carbonaceous materials has been observed in Amazon. The carbonaceous materials include primitive and unaltered OM that shares similarity with the IOM in primitive (CI,CM,CR) carbonaceous chondrites, as well as OM that has been heavily graphitised. The organic structure of the heated material is best represented by nanocrystalline graphite, comparable to that observed for metamorphosed meteorites (e.g., L3–6 Inman, Tieschitz and New Concord,CV3 Allende, and EH4 Indarch),suggesting peak metamorphic temperatures (PMT) of >~600°C. The thermal history recorded in the graphitic OM agrees with PMT estimates for returned Itokawa regolith grains (600–800°C)[7].We have obtained the H,C,N isotopic compositions for the primitive OM in Amazon, which exhibits unambiguously extraterrestrial isotopic signatures (δD = +4868±2288‰; δ13C = −24±5‰; δ15N = +344±20‰), contrasting to the typically negative isotopic values obtained for terrestrial organic matter[8]. The δD and δ13C values of the organic material in Amazon are comparable to OCs, however, the δ15N value is higher than that typically observed for OCs (δ15N = −47 to +36‰), and is similar to that of CRs (δ15N = +153 to +309‰)[9].Our data suggest a genetic link between the primitive organic material observed in Itokawa to CRs and IDPs for they share similar D, 13C and 15N enrichments[10].The high carbon contents of the five category 3 Itokawa particles suggest potentially higher OM abundances, hence we extracted and analysed amino acids in these samples. Although terrestrial contamination was observed primarily as L-protein amino acids, several terrestrially uncommon non-protein amino acids were also observed at low abundances, such as β-aminoisobutyric acid (β-AIB),β-amino-n-butyric acid (β-ABA), and β-alanine. Itokawa amino acid content observed here was dissimilar to thermally altered OCs, but preliminarily analogous to more aqueously altered CR2s.Continued evolution of Itokawa is evident by the in fall of primitive organic material derived from CRs/IDPs, accounting for a complex interplay between the remnant Itokawa silicates with exogenous organics. The results reported here are the first evidence of extraterrestrial OM in asteroid material from a sample-return mission, showcasing a working protocol for analysing samples returned by the Hayabusa2 and OSIRIS-REx missions

Q. H. S. Chan