Search NASA⌕ Search

SEARCH · Search NASA

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mult-Pollutant Control Through Novel Approaches to Oxygen Enhanced Combustion

Growing concerns about global climate change have focused effortss on identifying approaches to stabilizing carbon dioxide levels in the atmosphere. One approach utilizes oxy-fuel combustion to produce a concentrated flue gas that will enable economical CO{sub 2} capture by direct methods. Oxy-fuel combustion rewuires an Air Separation Unit (ASU) to provide a high-purity stream of oxygen as well as a Compression and Purification Unit (CPU) to clean and compress the CO{sub 2} for long term storage. Overall plant efficiency will suffer from the parasitic load of both the ASU and CPU and researchers are investigating techniques to enhance other aspects of the combustion and gas cleanup proceses to improve the benefit-to-cost ratio. This work examines the influence of oxy-fuel combustion and non-carbon based sorbents on the formation and fate of multiple combustion pollutants both numerically and experimentally.

54 ENVIRONMENTAL SCIENCES↗

Co-Firing Oil Shale with Coal and Other Fuels for Improved Efficiency and Multi-Pollutant Control

Oil shale is an abundant, undeveloped natural resource which has natural sorbent properties, and its ash has natural cementitious properties. Oil shale may be blended with coal, biomass, municipal wastes, waste tires, or other waste feedstock materials to provide the joint benefit of adding energy content while adsorbing and removing sulfur, halides, and volatile metal pollutants, and while also reducing nitrogen oxide pollutants. Oil shale depolymerization-pyrolysis-devolatilization and sorption scoping studies indicate oil shale particle sorption rates and sorption capacity can be comparable to limestone sorbents for capture of SO2 and SO3. Additionally, kerogen released from the shale was shown to have the potential to reduce NOx emissions through the well established “reburning” chemistry similar to natural gas, fuel oil, and micronized coal. Productive mercury adsorption is also possible by the oil shale particles as a result of residual fixed-carbon and other observed mercury capture sorbent properties. Sorption properties were found to be a function particle heating rate, peak particle temperature, residence time, and gas-phase stoichmetry. High surface area sorbents with high calcium reactivity and with some adsorbent fixed/activated carbon can be produced in the corresponding reaction zones that exist in a standard pulverized-coal or in a fluidized-bed combustor.

01 COAL, LIGNITE, AND PEAT↗

Controlling pollutant emissions in a high-pressure combustor with fuel-diluent blending

This paper investigates the formation of nitric oxide (NO) and carbon monoxide (CO) emissions as a function of nitrogen (N 2 ) or carbon dioxide (CO 2 ) diluent content, added to a premixed reacting jet in crossflow. Here, reaction characteristics of a rich methane-air jet injected into a lean vitiated crossflow were analyzed at an elevated pressure of 5 atm. The jet was pre-heated and enriched with 0%, 15%, 30%, and 50% mass fraction to quantify the effect on pollutant emissions. Simulated results of the full chemistry Star-CCM+CFD model were verified with data taken in the experimental high-pressure combustion facility, which provides pressure, temperature and velocity profiles, as well as line-of-sight chemiluminescence and exit emission measurements. The analysis revealed the significant influence of the diluent to delay axial combustion; this mixing delay increased the axial flame lift-off and controlled any thermal ignition limitations. Increasing the diluent content increased the timescale for the flame to stabilize, which allowed for greater entrainment of crossflow oxidizer into the axial jet stream, and led to decreased pollutant emissions. Hence, crossflow entrainment is a critical driving force at high diluent content. Local nitric oxide (NO) emission formation in the axial stage was predicted numerically, showing the correlation between diluent addition, axial heat release, and the formation of nitric oxide pollution. The high diluent levels leaned out the jet mixture and delayed axial combustion, while reducing prompt and thermal NOx by mitigating flame hotspots and minimizing the timescale that the products remain at high temperatures.

03 NATURAL GAS↗

Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study

This report details a study into the demand response potential of a large wastewater treatment facility in San Francisco. Previous research had identified wastewater treatment facilities as good candidates for demand response and automated demand response, and this study was conducted to investigate facility attributes that are conducive to demand response or which hinder its implementation. One years' worth of operational data were collected from the facility's control system, submetered process equipment, utility electricity demand records, and governmental weather stations. These data were analyzed to determine factors which affected facility power demand and demand response capabilities The average baseline demand at the Southeast facility was approximately 4 MW. During the rainy season (October-March) the facility treated 40% more wastewater than the dry season, but demand only increased by 4%. Submetering of the facility's lift pumps and centrifuges predicted load shifts capabilities of 154 kW and 86 kW, respectively, with large lift pump shifts in the rainy season. Analysis of demand data during maintenance events confirmed the magnitude of these possible load shifts, and indicated other areas of the facility with demand response potential. Load sheds were seen to be possible by shutting down a portion of the facility's aeration trains (average shed of 132 kW). Load shifts were seen to be possible by shifting operation of centrifuges, the gravity belt thickener, lift pumps, and external pump stations These load shifts were made possible by the storage capabilities of the facility and of the city's sewer system. Large load reductions (an average of 2,065 kW) were seen from operating the cogeneration unit, but normal practice is continuous operation, precluding its use for demand response. The study also identified potential demand response opportunities that warrant further study: modulating variable-demand aeration loads, shifting operation of sludge-processing equipment besides centrifuges, and utilizing schedulable self-generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nevada National Security Site E-Tunnel Wastewater Disposal System Quarterly Monitoring Report, Water Pollution Control Permit NEV 96021 (First Quarter Calendar Year 2020)

This report includes the results of monthly inspections and monitoring for January, February, and March 2020. Monthly inspections and monitoring were conducted on January 15, February 12, and March 17, 2020. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, soil conditions on and around the berms, erosion or sloughing of the slopes of the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurements of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the E-Tunnel Wastewater Disposal System discharge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of the Effect of Air Pollution Controls on Trends in Shortwave Radiation over the United States from 1995 through 2010 from Multiple Observation Networks

Long term datasets of total (all-sky) and clear-sky downwelling shortwave (SW) radiation, cloud cover fraction (cloudiness) and aerosol optical depth (AOD) are analyzed together with aerosol concentration from several networks (e.g. SURFRAD, CASTNET, IMPROVE and ARM) in the United States (US). Seven states with varying climatology are selected to better understand the effect of aerosols and clouds on SW radiation. This analysis aims to test the hypothesis that the reductions in anthropogenic aerosol burden resulting from substantial reductions in emissions of sulfur dioxide and nitrogen oxides over the past 15 years across the US has caused an increase in surface SW radiation. We show that the total and clear-sky downwelling SW radiation from seven sites have increasing trends except Penn State which shows no tendency in clear-sky SW radiation. After investigating several confounding factors, the causes can be due to the geography of the site, aerosol distribution, heavy air traffic and increasing cloudiness. Moreover, we assess the relationship between total column AOD with surface aerosol concentration to test our hypothesis. In our findings, the trends of clear-sky SW radiation, AOD, and aerosol concentration from the sites in eastern US agree well with our hypothesis. However, the sites in western US demonstrate increasing AOD associated with mostly increasing trends in surface aerosol concentration. At these sites, the changes in aerosol burden and/or direct aerosol effects alone cannot explain the observed changes in SW radiation, but other factors need to be considered such as cloudiness, aerosol vertical profiles and elevated plumes.

1995-2010↗

Advanced technology for controlling pollutant emissions from supersonic cruise aircraft

Gas turbine engine combustor technology for the reduction of pollutant emissions is summarized. Variations of conventional combustion systems and advanced combustor concepts are discussed. Projected results from far term technology efforts aimed at applying the premixed prevaporized and catalytic combustion techniques to aircraft combustion systems indicate a potential for significant reductions in pollutant emission levels.

Duerr, R. A.↗

Pollution Control Device

BHA Group Inc.'s PrecipTech Power Guard SQ-200 automatic voltage controller, combined with a remote computer, is an automatic management system for smoke-cleaning precipitators. It is the second generation of the SQ 100 developed at Langley Research Center, and was commercialized by two NASA employees. An electrostatic precipitator cleans the smoke by removing particulate matter from smokestack gases before gases are expelled into the atmosphere. Smokestack gas is passed through a precipitator chamber and exposed to an electrostatic field; dust particles in the gas become electrically charged, migrate to collection surfaces and are "captured." Developed under a NASA program seeking a way to dispose refuse, the system monitors sparking, automatically adjusts to changes in operating conditions and does not require a skilled operator.

Source record↗