Search NASA⌕ Search

SEARCH · Search NASA

Results for “PPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Real-Time Ammonia and Humidity Monitoring with Ultra-Fast Conductometric Sensors Based on Porphyrin and Phthalocyanine Complexes

Organic semiconductors like porphyrins and phthalocyanines are attracting a wide range of researchers due to their versatile electrical properties and sensing performances in conductometric sensors. In this study, we investigate two types of π-extended porphyrins, which share the same macrocyclic structure but differ in their central metal. These porphyrins are employed as sublayers in bilayer heterojunction devices, with the lutetium bisphthalocyanine complex, LuPc 2 , serving as the common top layer. Remarkably, the central metal in the porphyrin macrocycle significantly influences the solubility of the materials and, consequently, the surface topography of the resulting bilayer heterojunction devices. This structural variation translates into distinct electrical and sensing performances. The device incorporating nickel as metal centre (AM2) demonstrates superior sensitivity towards NH3, with a relative response (RR) of ca. -7% at 90 ppm, an ultra-fast response time of about 9 s, and an impressive limit of detection (LOD) of 250 ppb, whereas, the device that has zinc as metal centre in sublayer (AM3) exhibits RR value of ca. -0.9% at 90 ppm with t 90 of ca. 120 s and LOD of 2 ppm. Both devices are evaluated under randomly varying NH 3 concentration and RH value. The results shows that the AM2-based sensor allows following NH 3 in real-time, while the AM3-based sensor delivers an average concentration over time. On the other hand, the AM2-based sensor exhibits slow kinetics under RH exposure, while the AM3-based sensor precisely mirrors the pattern of random RH changes generated by the software, demonstrating its exceptional responsiveness and accuracy in tracking humidity fluctuations. In conclusion, these findings underscore the critical role of the metal centre in tuning the electrical and sensing properties of the heterojunction devices.

99 GENERAL AND MISCELLANEOUS↗

Development of an Energy-Efficient and High-Productivity Ammonia Recovery and Removal Process Using Resin-Wafer Electrodeionization

As efforts to develop various energy resources, ammonia energy is emerging as a promising carbon-free fuel alternative. Recovering high-concentration ammonia and ammonium from wastewater potentially offers significant environmental and economic benefits. However, research on recovery technologies for industries such as semiconductors remains limited. This study develops an efficient, energy-saving ammonia recovery technology using Resin Wafer Electrodeionization (RW-EDI), specifically for the semiconductor industry. RW-EDI shows promise for recovering ammonia from high-concentration wastewater. By optimizing parameters, such as voltage and initial concentration, a balance between productivity and energy consumption is achieved. Results indicate that ammonium and fluoride ion transport kinetics are similar, with minimal competition and selectivity values between 0.95 and 1.08. As the initial ammonia/ammonium concentration increases from 500 to 8000 ppm, reaction rate constants and the overall mass transfer coefficient decrease. Increasing the voltage can enhance mass transfer and eliminate barriers. Ion transport primarily occurs in the RW solid phase, accounting for 93.89% of the total current. Additionally, RW-EDI shows superior specific energy consumption within a concentration range of 500 ppm to 8000 ppm, outperforming technologies like electrodialysis by reducing specific energy consumption from 8−15 kWh/kg-NH 4 + to 1.2−2.5 kWh/kg-NH 4 + . This study highlights RW-EDI’s potential for ammonia recovery, providing valuable insights for future applications in wastewater treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BTRIC Technical Support for Appalachia: FY 2024 Summary Report on Net Negative Carbon Building Demonstration with AgPod

This report investigates the effects of various concentrations of CO 2 on the photosynthesis and biomass accumulation of crops growing in an AgPod, using kale as the test crop. In the first year of the study, increasing the CO 2 concentration in the AgPod was found to promote higher photosynthetic rates in kale plants up to 1,300 ppm (the highest CO 2 concentration measured). An interesting finding was that net photosynthetic rates of kale leaves remain unsaturated until reaching unusually high levels of photosynthetically active radiation (PAR, > 1,200 µmol m -1 s -1 ) and CO 2 concentration (> 1,100 ppm). Such high levels of saturating PAR and CO 2 concentration values rarely occur under natural conditions, suggesting a promising potential for carbon capture via enriched controlled environment agriculture (ECEA). During the second year of the study, a second crop was planted to confirm the actual effects on growth with increased CO 2 concentrations. Our results suggest that growing kale plants in the AgPod system at higher CO 2 levels resulted in a successful and highly productive crop, up to three times the amount grown at 415 CO 2 . Further, the kale plants grown under higher CO 2 conditions (1000 ppm) are not CO 2 saturated and can potentially further improve yield at even higher CO 2 environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Versatile & Intelligent Biodetection via Environmental Sensing (VIBES)

Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.

47 OTHER INSTRUMENTATION↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

National Park Air Quality Index Dataset

The National Park Air Quality Index dataset (NPS-AQI) consists of webcam images taken from the National Park Service's publicly available air quality web cameras and associated measurements for air pollutants, AQI, and meteorological data obtained via the publicly available NPS Gaseous Pollutant Monitoring Program. The full dataset is a collection of 146,822 images paired with air quality measurements. The specific measurements reported are: ozone ppm, 8-hour running average ozone ppm, so2 ppm, AQI (derived from ozone), temperature, and humidity. The images are 1500X1000 pixel PNG files arranged into folders by NPS site and named according to the time and date the image was taken. There are three CSV files (representing "training", "validation", and "testing" images splits) containing image names and associated NPS site names, air pollutant measurements, and meteorlogical data.

Svinth, Christian N↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Run 2/3 measurement of the muon anomalous magnetic moment by the Muon g-2 experiment at Fermilab

The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_μ=(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from 2018, confirmed the previous measurement at Brookhaven National Laboratory with a comparable sensitivity of 0.46 ppm. In 2023, a new result based on Run 2 and Run 3 data, collected in 2019 and 2020, was released. These datasets contain four times the data from Run 1, significantly enhancing sensitivity and achieving an unprecedented uncertainty of 0.20 ppm. This advancement resulted in a two-fold improvement in both statistical and systematic uncertainties. Here, we will discuss the muon $g-2$ measurement, the increased precision relative to the Run 1 result, and provide an outlook on future measurements which will incorporate datasets from 2021 to 2023. Additionally, we will explore the implications of comparing the new measurements with the latest Standard Model predictions for muon g-2.

Zaid, Estifa'a [Liverpool U.]↗

Mid-Atlantic US observations of radiocarbon in CO 2 : fossil and biogenic source partitioning and model evaluation

Accurately quantifying regional anthropogenic CO 2 fluxes is fundamental to improving our understanding of the carbon cycle and for creating effective carbon mitigation policies, and the radiocarbon to total carbon ratio in atmospheric CO 2 (Δ 14 CO 2 ) is a robust tracer of fossil fuel CO 2 that can discriminate between biogenic and fossil fuel CO 2 sources. NASA's Atmospheric Carbon and Transport-America (ACT-America) airborne mission between 2016 and 2019 aimed to improve the accuracy of regional greenhouse gas flux estimates, through refining our understanding and characterization of fluxes and flux uncertainties in models. Δ 14 CO 2 observations from 26 flights are presented for examining seasonal CO 2 source partitioning in the Mid-Atlantic USA. Observed variability in boundary layer CO 2 at timescales ranging from intra-day to seasonal was largely driven by biogenic CO 2 (CO 2bio ) variability that ranged from −19.7 ppm in summer to 16.2 ppm in fall, while fossil fuel CO 2 (CO 2ff ) variability remained at 3.3±2.0 ppm. Carbonyl sulfide uptake was well-correlated with CO 2bio uptake, and examining this relationship, as well as that between CO 2 and CO 2bio variability reinforces the seasonal extent of gross primary productivity response throughout ACT-America. We use airborne Δ 14 CO 2 flask sampling alongside in situ carbon monoxide measurements to calculate high-frequency CO 2ff and evaluate the magnitude and diurnal variability of modeled CO 2ff , deducing likely transport errors in an example flight. Although ACT-America CO 2ff signals were attenuated due to the broad source regions sampled, results illustrate the value of Δ 14 CO 2 sampling and observation-based methodologies for regional CO 2 flux attribution, evaluation and improvement of modeled CO 2 .

Baier, Bianca C. [National Oceanic and Atmospheric↗

CMI Winter Meeting 2025 Presentation

Lanthanides are important to many technologies including magnets used in high efficiency traction motors. While common in the environment and industrial waste streams, lanthanides are often present at very low concentrations. This work demonstrates synergistic lanthanide recovery from an aqueous magnet leachate to single ppm concentrations using Na2SO4 addition and subsequent DME-FC treatment. It was found that combining DME-FC with low concentrations of Na2SO4 (~0.1 M) results in synergistic isolation of lanthanides while making use of Na2SO4, an excessive byproduct of hydrometallurgical metal production. Combined Na2SO4 + DME reduced lanthanide metal ion's (Pr, Nd, Sm, Gd, Dy, and Ho) solubilities by 1,000 - 25,000x with final concentrations ranging from 2 ppm to 200 ppm. This can be compared to 0.1 M Na2SO4 alone providing a 10 - 200x reduction and DME providing a 100 - 1,500x reduction in lanthanide solubilities. Final solution concentrations of lanthanides were 99.8% lower than what could not be achieved with either individual process. The results also reveal different periodic trends in the solubility reduction for DME and Na2SO4.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

4.6 V Moisture‐Tolerant Electrolytes for Lithium‐Ion Batteries

Abstract Commercial LiPF 6 ‐based electrolytes face limitations in oxidation stability (4.2 V) and water tolerance (10 ppm). While replacing LiPF 6 with lithium bis(trifluoromethane)sulfonimide (LiTFSI) improves water tolerance, it induces Al current collector corrosion above 3.7 V vs. Li/Li + . To address this, lithium cyano(trifluoromethanesulfonyl)imide (LiCTFSI) is proposed here as a non‐corrosive, moisture‐tolerant alternative. The 2.0 M LiCTFSI/propylene carbonate (PC)‐fluoroethylene carbonate (FEC) (7:3 by volume) electrolyte enables LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NCM811) cathodes to reach 210 mAh g −1 (2.8‐4.6 V) with a cycle life of 500. Full cells with NCM811||graphite (2.0 mAh cm −2 ) show 77.8% capacity retention after 500 cycles. Even with 2000 ppm moisture in the electrolyte, full cells maintain high cycling stability, reducing the need for costly dry rooms. The electrolyte’s low freezing point and high thermal stability enable the operation from ‐20 °C to 60 °C, delivering 168 mAh g −1 at ‐20 °C and retaining 94% capacity after 100 cycles at 60 °C. In contrast, cells with commercial LiPF 6 electrolyte deliver 71 mAh g −1 at ‐20°C and retain 52.7% after 100 cycles at 60 °C. This novel salt offers a cost‐effective solution for developing robust, high‐performance batteries suitable for extreme conditions.

Zhang, Nan↗

Initiator‐Driven Tailoring of Reactivity and Inhibition in Frontally Polymerized Dicyclopentadiene‐Co‐Dihydrofuran Thermosets

Incorporating 2,3‐dihydrofuran (DHF) into dicyclopentadiene (DCPD) enables frontally polymerizable, deconstructible thermosets via acid hydrolysis. At 5–20 mol% DHF and low initiator concentration (~100 ppm), DHF inhibits front propagation, lowers the glass transition temperature ( T g ) by up to 20°C, and quenches the front, especially at 20% DHF. This paper demonstrates that increasing the initiator concentration to 250–1000 ppm overcomes inhibition, enhances front speeds by ~50%, and suppresses quenching at the expense of pot‐life. Above 5 mol% DHF, an emergence of a second exotherm is observed, attributed to increased rate dependence on the inhibition of the initiator by DHF. Void formation from volatile DHF is suppressed by applying 110 kPa nitrogen, though at the cost of reduced front speed. Dynamic mechanical analysis shows that higher initiator concentration produced more highly cross‐linked polymers, with a ~20% increase in storage modulus at 25°C and a 20°C increase in T g .

deconstructible thermosets↗

Ionic Pairs-Engineered Fluorinated Covalent Organic Frameworks Toward Direct Air Capture of CO 2

The covalent organic frameworks (COFs) possessing high crystallinity and capability to capture low-concentration CO 2 (400 ppm) from air are still underdeveloped. The challenge lies in simultaneously incorporating high-density active sites for CO 2 insertion and maintaining the ordered structure. Herein, a structure engineering approach is developed to afford an ionic pair-functionalized crystalline and stable fluorinated COF (F-COF) skeleton. The ordered structure of the F-COF is well maintained after the integration of abundant basic fluorinated alcoholate anions, as revealed by synchrotron X-ray scattering experiments. The breakthrough test demonstrates its attractive performance in capturing (400 ppm) CO 2 from gas mixtures via O$-$C bond formation, as indicated by the in situ spectroscopy and operando nuclear magnetic resonance spectroscopy using 13 C-labeled CO 2 sources. Both theoretical and experimental thermodynamic studies reveal the reaction enthalpy of ≈-40 kJ mol -1 between CO 2 and the COF scaffolds. This implies weaker interaction strength compared with state-of-the-art amine-derived sorbents, thus allowing complete CO 2 release with less energy input. The structure evolution study from synchrotron X-ray scattering and small-angle neutron scattering confirms the well-maintained crystalline patterns after CO 2 insertion. In conclusion, the as-developed proof-of-concept approach provides guidance on anchoring binding sites for direct air capture (DAC) of CO 2 in crystalline scaffolds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dilute Regeneration-Driven Membrane Capacitive Deionization of Synthetic Seawater Using Nanopatterned Membranes and Prussian Blue Analog Electrodes

Membrane capacitive deionization (MCDI) offers energy-efficient seawater desalination but is limited at high salinity by membrane resistance and incomplete electrode regeneration. Nanopatterned ion-exchange membranes, dilute regeneration protocols, and Prussian blue analog (PBA)-functionalized electrodes are combined in a flow-by-MCDI cell. Nanopatterned ion-exchange membranes (hexagonal, octagonal, double-ring, rectangular) enhance interfacial ion transport, with hexagonal geometry delivering ≈12.5% greater surface area and the best performance. PBA-functionalized electrodes increase salt adsorption and charge-transfer kinetic rates. The integrated system lowers the area-specific resistance by 45 Ω cm2, resulting in a 500 mV reduction in the cell voltage for a current density of 2 mA cm−2 for a 35 000 ppm NaCl feed. This improves the energy-normalized salt adsorption six fold (64–382 mmol J−1). Low salinity (2000 ppm) and mixed-salt regeneration sustains a ≈39% water recovery and stable performance for at least seven cycles. Overall, combining nanopatterned membranes, which promote confinement-enhanced ion mobility, and PBA electrodes, which enhance salt adsorption, improved the energy efficiency of MCDI.

Hasan, Mahmudul↗

Pressure-induced cation and vacancy disorder-order transition and near-zero τ f in deficient hexagonal perovskite Ba 8 ZnTa 6 O 24 dielectrics

Pressure applications can enable the tuning of atomic/defect ordering and provide access to new functional materials. Here, in this study, we report that pressure-induced structural transformation featuring disorder-order transition of both cations and vacancies in the 8-layer deficient hexagonal perovskite tantalate dielectrics Ba 8 ZnTa 6 O 24 , which transformed the structure from twin to shift and remarkably lowered the temperature coefficient of resonant frequency τ f down to near zero (∼0.56 ppm/°C) from 38 ppm/°C for the twinned precursor. The atomic scale STEM-HAADF and EDS results confirm the ordering of Zn in the Ta host at the nanometer scale in the shifted material featuring well-ordered Ba 8 ZnTa 6 O 24 slabs intergrown with Ba 3 ZnTa 2 O 9 and Ba 5 Ta 4 O 15 monolayers and anti-phase grain boundaries as planar defects. The pressure-induced twin-shift structural transformation of Ba 8 ZnTa 6 O 24 features the rare constant concentration of the hexagonal stacked layers, which is allowed by the vacancy ordering at the central layers of face-shared octahedral (FSO) trimers avoiding the FSO B-B repulsion, and remarkably the faster cationic ordering kinetics compared with the 2:1 ordered complex perovskites. Although the inclusion of numerous planar defects and the oxidizable atomic defects led to significant p-type conduction and inhomogeneous electrical microstructures, resulting in an extraordinarily high extrinsic dielectric loss for the high-pressure shifted Ba 8 ZnTa 6 O 24 pellet, the intrinsically near-zero τ f could make the shifted Ba 8 ZnTa 6 O 24 perovskite an ideal microwave dielectric resonator candidate if the defects could be eliminated.

high pressure↗

Rare earth element potential in coal and coal ash in the U.S. Gulf Coast

United States heavy reliance on imports of critical minerals (CMs), including rare earth elements (REEs), underscores the importance of development of domestic sources. The study objective was to quantify CM and REE concentrations in coal and coal ash in the US Gulf Coast region. CM and REE concentrations were measured for 118 samples from outcrops and 14 mines in the Gulf Coast. Results show that total REE + Yttrium (REY) concentrations (dry coal basis) are comparable to those of the upper continental crust (UCC) with localized hot spots, such as the Texas Gibbons Creek mine (REY ≤ ~ 2860 ppm). When normalized to UCC REY concentration (169 ppm, dry coal basis), REY to UCC ratios for Gulf Coast coal samples range from 0.1 to 17 (median ratio 0.6). REE extractability from lignites is high (median: 63%–93%) using environmentally benign weak acid. In addition to raw coal, coal ash from power plants could also serve as an REE source with a median ratio of REY in ash relative to coal of 4; however, extractability from coal ash is generally much lower (≤ 5% using the same weak acid as in coal). The median basket price for extracted REY as oxides from coal, assuming 70% extractability, is $\$3.2$ per tonne of coal and $\$186$ billion based on 58 billion metric tonnes of dry coal in the Gulf Coast. REEs important for magnets (Pr + Nd + Tb + Dy) account for ~ 80% of the total value. The corresponding median basket price for extracted REY as oxides from coal ash, assuming ~ 30% extractability, is ~$\$4.4$ per tonne of ash and $\$1.2$ billion based on 258 million tonnes of ash. REE production from coal would likely require co-products, such as activated carbon or humic acids, to attain economic viability. Production of REEs from coal ash could offset remediation costs related to potential water contamination. This reconnaissance study shows the potential for REE production from coal and coal ash in the Gulf Coast; however, carbon coproducts and/or societal benefits would likely be required for socioeconomic viability.

01 COAL, LIGNITE, AND PEAT↗

The effect of copper additives on hybrid Zr-based chemical conversion coating morphology and chemical compositions

In the realm of corrosion protection, Zr-based conversion coatings offer an environmentally friendly, chromate-free alternative to conventional coating. This study uses advanced X-ray, electron microscopy and electrochemical testing techniques to better understand the impact of varying Cu²⁺ ion concentrations on the characteristics of Zr-based coatings on Fe substrates. Our findings demonstrate that within the tested conditions, higher Cu²⁺ additive concentrations at 40 ppm enhance surface characteristics, increasing stability towards anti-corrosion capability, particularly under NaCl treatment. Conversely, at a lower Cu²⁺ concentration of 20 ppm, coatings exhibited more significant dissolution of Cu clusters and increased vulnerability to chloride-induced degradation. X-ray photoelectron spectroscopy and synchrotron X-ray fluorescence (XRF) and X-ray absorption near edge structure (XANES) spectroscopy analyses revealed Cu²⁺ formation in Cu20, while Cu40 retained its metallic state (Cu⁰) with a slower reaction rate. Cu20 offers some protection but lacks durability, whereas in Cu40, lower I corr , and enhance corrosion resistance, making it ideal for protective coatings in salt-water environments. This study underscores the importance of balancing Cu²⁺ ions concentration in the coating solution to optimize performance, highlighting the role of Cu in enhancing both surface properties and long-term stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗