Search NASASearch

SEARCH · Search NASA

Results for “PRESSURE VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

318 records · Page 3

Construction of an Exact Pressure-Equilibrium Scheme for the Five-Equation Two-Phase Flow Model With Thermal Relaxation

Numerical simulation of compressible multiphase flows based on the four-equation (homogeneous relaxation) model is known to suffer from two fundamental difficulties with (a) wave propagation and (b) pressure equilibrium preservation. First, the mixture sound speed exhibits non-monotonic dependency with respect to the volume fraction, which leads to robustness issues in the resolution of shocks and acoustic wave propagation across two-phase regions. This difficulty can be mitigated by solving Allaire’s five-equation model augmented with infinitely fast phasic temperature equilibrium, from which solutions of the four-equation model can be recovered. However, when temperature is non-uniform, this augmented five-equation formulation still fails to preserve pressure equilibrium across material interfaces. In this work, we propose a fully conservative numerical scheme that exactly preserves pressure equilibrium at the discrete level for the augmented five-equation model, for arbitrary initial distributions of temperature and volume fraction. Combined with the monotonic sound speed property of the five-equation formulation, the proposed pressure-equilibrium preserving scheme significantly improves robustness in the presence of strong multiphase interactions, including shock–interface interactions and advection of material interfaces.

ESG

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs

Spin-strain interactions under hydrostatic pressure in α-RuCl 3

We investigate the effects of hydrostatic pressure on 𝛼−RuCl 3 , a prototypical material for the Kitaev spin model on a honeycomb lattice with a possible spin-liquid ground state. Using ultrasound measurements at pressures up to 1.16 GPa, we reveal significant modifications of the acoustic properties and the 𝐻−𝑇 phase diagram of this material. Hydrostatic pressure suppresses the three-dimensional magnetic order and induces a dimerization transition at higher pressures. At low pressures, the sound attenuation exhibits a linear temperature dependence, while above 0.28 GPa, it becomes nearly temperature independent, suggesting a shift in the phonon scattering regime dominated by Majorana fermions. These findings provide new insights into spin-strain interactions in Kitaev magnets and deliver a detailed characterization of the 𝐻−𝑇 phase diagram of 𝛼−RuCl 3 under hydrostatic pressure.

Focused ion beam

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno

Impacts of Reduced Pressure Atmospheres on Environmental Control and Life Support Systems (ECLSS) Architectures

The study found that while nine subsystems are viable without modification at 10.2 psia, only three remain acceptable at 8.2 psia. Material flammability presents the most critical hurdle in the 8.2 psia/34-40% O 2 environment, where 70% of the assessed subsystems will require material replacements, many of which have yet to be developed. Ultimately, adapting ISS heritage hardware to these exploration conditions will introduce varied mass, power (e.g., increased fan speeds), and significant schedule impacts driven by the need for extensive testing, redesign, and recertification. The report concludes with specific recommendations for targeted analysis and testing to quantify these impacts and guide necessary design modifications.

Environmental Control and Life Support Systems

Pressurized-Cell Experiment

Pressurized-cell detectors were developed and constructed at the Langley Research Center to obtain a direct measurement of the micrometeoroid puncture hazard to thin structural material. A total of 160 detectors were mounted around the periphery of the rocket motor used on the Explorer XIII satellite. (See fig. IX-1.) Material thicknesses of 0.001, 0.0015, 0.002, 0.0025, and 0.005 inch were used on the detectors. The exposed surface of the test material of each detector was 21.8 square inches and the total exposed surface of the 160 detectors was 24.2 square feet. The average weight of the detectors was 68 grams.

Micrometeoroid

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device

Equation of state for Hf, Ta, W, Re, Os, Ir, Pt, and Au to multi-terapascal pressures from density-functional theory

We present the zero-temperature equation of state (pressure dependence of compression) and phase stability predictions for the 5d-transition metals obtained from all-electron density-functional theory (DFT) calculations. The results compare favorably with experiments but extend beyond current experimental capabilities to 10 TPa. Our study reveals phase changes that are explained from the calculated electronic structure. The cubic face-centered and body-centered structures (fcc and bcc), together with two-, three-, and four-layered hexagonal structures, play major roles under compression. The results’ dependence on the electron exchange and correlation in the DFT approach is investigated, and it is shown that the impact of the choice, while significant at lower pressures, diminishes in the terapascal regime. We further illustrate that the normal parabolic trends in atomic volume and bulk modulus with atomic number, due to the occupation of bonding and anti-bonding 5d states, break down at TPa pressures, suggesting drastically different chemical bonding at these extreme conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Measure sea level air pressure from space to improve knowledge and forecasting of the atmospheric state

Modern numerical weather prediction (NWP) and analysis models require globally-observed meteorological data including sea-level pressure (SLP) for accurate operations. Up until now, SLP has only been measured by in situ instruments from ships, buoys, and ocean platforms. These measurements are sparse with large gaps, leaving models starved of this critical information to constrain the atmospheric state. Recent advancements in differential absorption radar (DAR) provide a path to close this critical observation gap through spaceborne observations in the coming decade, improving the analysis models relied upon for atmospheric research and the weather forecasts depended upon daily for public safety and commerce.

Matthew L Walker McLinden