Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Semiconductor nanocrystal probes for biological applications and process for making and using such probes

A semiconductor nanocrystal compound and probe are described. The compound is capable of linking to one or more affinity molecules. The compound comprises (1) one or more semiconductor nanocrystals capable of, in response to exposure to a first energy, providing a second energy, and (2) one or more linking agents, having a first portion linked to the one or more semiconductor nanocrystals and a second portion capable of linking to one or more affinity molecules. One or more semiconductor nanocrystal compounds are linked to one or more affinity molecules to form a semiconductor nanocrystal probe capable of bonding with one or more detectable substances in a material being analyzed, and capable of, in response to exposure to a first energy, providing a second energy. Also described are processes for respectively: making the semiconductor nanocrystal compound; making the semiconductor nanocrystal probe; and treating materials with the probe.

36 MATERIALS SCIENCE↗

Multiple Deep Jovian Atmospheric Entry Probes: Building on the Galileo Probe

Following on the very successful Galileo Entry Probe mission, studies underway at the Jet Propulsion Laboratory (JPL) address the feasibility and cost of the Jupiter Deep Multi-probes (JDMP) mission to deliver and support multiple deep (100 bar level or deeper) atmospheric entry probes to Jupiter.

JPL Galileo Entry Probe Mission Jupiter Deep Multi↗

A method for site-specific and cryogenic specimen fabrication of liquid/solid interfaces for atom probe tomography

A site-specific, cryogenic, focused ion beam (FIB) method is presented for the preparation of atom probe tomography (APT) specimens from a frozen liquid/solid interface. As a practical example, the interface between water and a corroded boroaluminosilicate glass has been characterized by APT for the first time. The water/glass interface is preserved throughout specimen preparation by plunge freezing the corroding glass particles with the corrosion solution into slush nitrogen. Site-specific specimen preparation is enabled through a new approach to extract and mount a small volume of material using a cryogenically cooled FIB stage and micromanipulator. The prepared APT specimens are subsequently transferred from the FIB to APT under cryogenic and high-vacuum conditions using a novel FIB/APT transfer shuttle and home-built environmental transfer hub attached to the APT system. Particular focus is given to the technical methods for specimen fabrication under cryogenic conditions. Persistent challenges are discussed in addition to future opportunities for this new specimen preparation method.

cryogenic FIB, atom probe tomography (APT), corros↗

Quaternary Ammonium Salt Based NIR‐II Probes for In Vivo Imaging

Abstract Traditional luminescent materials including fluorescent probes suffer from notorious aggregation‐caused quenching in aqueous solutions. Although several approaches such as the aggregation‐induced emission effect have been developed, it remains a significant challenge to identify an effective and efficient strategy to resolve this issue. Herein, quaternary ammonium salts Q8PBn and Q8PNap as a novel class of bright near infrared window II (NIR‐II, 1000–1700 nm) probes are designed and synthesized, and the twisted intramolecular charge transfer formation at the excited state can be effectively suppressed for the newly designed probes. Furthermore, Q8PNap complexation with fetal bovine serum ( Q8PNap /FBS) significantly increases the quantum yield by ≈32‐fold compared with PEGylated tertiary amine Q8P , and Q8PNap /FBS is successfully used to achieve high spatial and temporal resolution imaging of hind limb vasculature, lymphatic system, and small tumor metastasis, as well as precise NIR‐II imaging‐guided tumor and lymph node surgery in small animal models for the first time.

Qu, Chunrong↗

Germanium Sulfide Nano-Optics Probed by STEM-Cathodoluminescence Spectroscopy

Nano-optical studies of confined modes in planar waveguides have attracted significant interest as a means to probe exciton-polaritons and other hybrid light-matter quasiparticles in layered semiconductors, such as transition metal dichalcogenides or boron nitride. There is a need to broaden such studies to other materials and to identify alternatives to scanning near-field optical microscopy for exciting and measuring confined waveguide modes. Here, we establish an approach for probing the dispersion of traveling waveguide modes by cathodoluminescence spectroscopy excited by the focused electron beam in scanning transmission electron microscopy (STEM-CL) and apply it to solid-state resonators consisting of mesoscale monocrystalline prisms and plates composed of GeS, an anisotropic layered semiconductor with direct bandgap in the near-infrared spectral range. Structure, crystallography, and chemical composition of the mesostructures are analyzed by analytical electron microscopy. STEM-CL maps and spectra show pronounced interference effects and sharp emission peaks at photon energies below the fundamental bandgap of GeS. Our analysis demonstrates that locally excited light emission in STEM-CL launches in-plane waveguide modes in the mesoscale GeS structures, which are internally reflected by highly specular GeS edges to cause interference of the waveguide modes. Reabsorption and secondary luminescence give rise to the intensity modulations detected in the far field. In conclusion, our results highlight avenues for probing light-matter interactions below the diffraction limit in a wide range of quantum materials and open up the possibility of tuning light emission geometrically using interference rather than by the conventional bandgap engineering.

36 MATERIALS SCIENCE↗

Pioneer Jupiter orbiter probe mission 1980, probe description

The adaptation of the Saturn-Uranus Atmospheric Entry Probe (SUAEP) to a Jupiter entry probe is summarized. This report is extracted from a comprehensive study of Jovian missions, atmospheric model definitions and probe subsystem alternatives.

Defrees, R. E.↗

The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits

The distinctive layering visible in images from Mars Global Surveyor of the Martian polar caps, and particularly in the north polar cap, indicates that the stratigraphy of these polar layered deposits may hold a record of Martian climate history covering millions of years. On Earth, ice sheets are cored to retrieve a pristine record of the physical and chemical properties of the ice at depth, and then studied in exacting detail in the laboratory. On the Martian north polar cap, coring is probably not a practical method for implementation in an autonomous lander. As an alternative, thermal probes that drill by melting into the ice are feasible for autonomous operation, and are capable of reasonable approximations to the scientific investigations performed on terrestrial cores, while removing meltwater to the surface for analysis. The Subsurface Ice Probe (SIPR) is such a probe under development at JPL. To explore the dominant climate cycles, it is postulated that tens of meters of depth should be profiled, as this corresponds to the vertical separation of the major layers visible in the MOC images [1]. Optical and spectroscopic analysis of the layers, presumably demarcated by embedded dust and possibly by changes in the ice properties, would contribute to the construction of a chronology. Meltwater analysis may be used to determine the soluble chemistry of the embedded dust, and to monitor gradients of atmospheric gases, particularly hydrogen and oxygen, and isotopic variations that reflect atmospheric conditions at the time the layer was deposited. Thermal measurements can be used to determine the geothermal gradient and the bulk mechanical properties of the ice.

Cardell, G.↗

Combined Impedance Probe and Langmuir Probe Studies of the Low-Latitude E Region

The EQUIS-2 sounding rocket and radar campaign, launched from Kwajalein Atoll in 2004, included a mission to study low-latitude irregularities and electrodynamics, led by NASA GSFC. This mission included two instrumented rockets launched into the nighttime E region (apogee near 120 km), which included comprehensive electrodynamics and neutral density instrumentation. These rockets carried the first of a new generation of impedance probes, that utilize a wide-band drive signal to simultaneously measure the impedance of an antenna in a plasma as a function of frequency from 7 kEIz to 4 MHz. at a rapid cadence. This technique promises to permit true plasma spectroscopy, and resulted in the identification of multiple plasma resonances and accurate measurements of the plasma density, even in the low density nighttime E region. We present analyses of the technique and resulting spectra, and show how these data may be combined with fixed-bias Langmuir Probe data to infer the temperature structure of the E region as well as providing accurate absolute calibrations for the very high time resolution fixed-bias probe data. The data is shown to agree well with data from ionosonde, the ALTAIR radar, and the Peruvian beacon experiment.

Rowland, D. E.↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional nanoscale characterisation of materials by atom probe tomography

The development of three-dimensional (3D), characterization techniques with high spatial and mass resolution is crucial for understanding and developing advanced materials for many engineering applications as well as for understanding natural materials. In recent decades, atom probe tomography (APT) which combines a point projection microscope and time-of-flight mass spectrometer has evolved to be an excellent characterization technique capable of providing 3D nanoscale characterization of materials with sub-nanometer scale spatial resolution, with equal sensitivity for all elements. This review discusses the current state as of beginning of the year 2016 of APT instrumentation, new developments in sample preparation methods, experimental procedures for different material classes, reconstruction of APT results, the current status of correlative microscopy, and application of APT for microstructural characterization in established scientific areas like structural materials as well as new applications in semiconducting nanowires, semiconductor devices, battery materials, catalyst materials, geological materials and biological materials. Finally, a brief perspective is given regarding the future of APT.

Atom Probe Tomography, characterization, microstru↗

Correlating Nanoscale Secondary Ion Mass Spectrometry and Atom Probe Tomography Analysis of Uranium Enrichment in Metallic Nuclear Fuel

Distribution and enrichment of 235U within nuclear fuels are essential to material performance and reactor safety. With the development of metallic U fuels, understanding 235U homogeneity has become increasingly important, however, it is difficult to map with high spatial, and mass resolution to analyze both matrix and secondary phase precipitates. Here, we analyze 235U enrichment in matrix and carbide phases in LEU-Mo via two chemical imaging modalities: nanoscale secondary ion mass spectrometry (nanoSIMS) and atom probe tomography (APT). NanoSIMS and APT provided consistent results, with no statistically significant difference between measured and nominal enrichment (19.75 % 235U).

U-10Mo, atom probe tomography, nanoscale secondary↗

Measurements of the work function of single-walled carbon nanotubes encapsulated by AgI, AgCl, and CuBr using Kelvin probe technique with different kinds of probes

We report the results on the measurements of the work function of single-walled carbon nanotubes encapsulated by Agl (AgI@SWCNT), AgCl (AgCl@SWCNT), and CuBr (CuBr@SWCNT) by the local Kelvin probe technique. We found the values of the work function of tubes encapsulated with AgI and AgCl (Φ(AgI@SWCNT) = 5.08 ± 0.02, Φ(AgCl@SWCNT) = 5.10 ± 0.02 eV) to exceed substantially that of pristine carbon nanotubes, and the value of the work function of carbon nanotubes encapsulated with CuBr is Φ(CuBr@SWCNT) = 4.89 ± 0.03 (eV). The measurements are carried out using different kinds of microscope probes including multi-walled carbon nanotube tips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing dynamics in colloidal crystals with pump-probe experiments at LCLS: Methodology and analysis

We present results of the studies of dynamics in colloidal crystals performed by pump-probe experiments using an X-ray free-electron laser (XFEL). Colloidal crystals were pumped with an infrared laser at a wavelength of 800 nm with varying power and probed by XFEL pulses at an energy of 8 keV with a time delay up to 1000 ps. The positions of the Bragg peaks, and their radial and azimuthal widths were analyzed as a function of the time delay. The spectral analysis of the data did not reveal significant enhancement of frequencies expected in this experiment. As a result, this allowed us to conclude that the amplitude of vibrational modes excited in colloidal crystals was less than the systematic error caused by the noise level.

36 MATERIALS SCIENCE↗

Revealing the Atomic Origin of Heterogeneous Li-Ion Diffusion by Probing Na

Tracing the dynamic process of Li-ion transport at the atomic scale is a long-cherished wish in solid state ionics and essential for battery material engineering. Approaches via phase change, strain, and valence states of redox species are developed to circumvent the technical challenge of direct imaging Li, however, all are limited by poor spatial resolution and weak correlation with state-of-charge (SOC). Here, we adopt an ion-exchange approach by sodiating the de-lithiated cathode and probing Na distribution to trace the Li de-intercalation, which enables us to visualize the heterogeneous Li-ion diffusion down to atomic level. In the model LiNi1/3Mn1/3Co1/3O2 cathode, dislocation-mediated ion diffusion is kinetically favorable at low SOC and planar diffusion along (003) layers dominates at high SOC, which work synergistically to determine the ion diffusion dynamics. Our work unveils the heterogeneous nature of ion diffusion in battery material and stresses the role of defect engineering in tailoring ion transport kinetics.

Xiao, Biwei↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗