LANL PVC bag-out-bag replacement [Slides]
The US material at 8 months aging, at room temperature and exposed to gamma at 80 degrees C has been completed. The FTIR data does not show any discernible difference between the US APU-ether material and the British material. There are some differences and the curves of the FTIR, but the behavior shows that the US material is behaving comparable to the British material. The British Blue sample exposed to gamma at 70 degrees C did have an observable change in the contact angle. This was the only notable change between the two different types of polymer the TGA on both the US and the British had no observable difference. Mechanical testing samples (dog-bones) are being prepared for tensile, shear, and puncture testing. This data will be provided in later meetings. Mass spec testing is needed to measure the headspace gases that are being seen during the aging study to better health characterize the radiolytic degradation of the APU ether samples, this is also ongoing.
The development of PVC extrusions for a 14,000 ton self-supporting structure for the detection of neutrinos.
Abstract Not Provided
DRAFT: Evaluation of Mechanical Properties at the Knit Line Interface in a Complex Multi-Cell PVC Extrusion
Abstract not provided
Noise suppressed partial volume correction for cardiac SPECT/CT
Purpose: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging. Methods: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher’s prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang’s method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a {sup 99m}Tc-tetrofosmin myocardial perfusion scan and a {sup 99m}Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with {sup 99m}Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang’s method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC. Results: The results showed that the Yang’s method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility. Conclusions: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.
Pelletization of Immobilized Amine Carbon Dioxide Sorbents with Fly Ash and Poly(vinyl chloride)
Abstract A combination of coal fly ash (FA) and a polymer binder, namely, poly(vinyl chloride) (PVC), was used to pelletize immobilized amine CO 2 sorbents. The pelletization of mixtures of FA and 50 wt % tetraethylenepentamine (TEPA) or ethylenimine oligomer mixture ( M w =423)/silica (EI 423 ‐S) with PVC created a rigid PVC/FA/sorbent network. The strength of the network was attributed, in part, to the hydrogen bonding of PVC with the hydroxy and amine groups of the FA and sorbent (infrared spectroscopy). Increasing the PVC molecular weight or FA content enhanced the pellet strength and reduced CO 2 capture. The optimum pellet, FA/EI 423 ‐S (20/80)_PVC 62 [10 wt % PVC 62 ( M w =62 000), 17 wt % FA], captured 1.33 mmol g −1 and exhibited a crush strength of 1.42 MPa. The reaction between PVC and amines produced ammonium ions (−NH 3 + /−NH 2 + ), which reduced the CO 2 captured by the pellet during stability testing. This issue was partially resolved by replacing PVC 62 with p ‐phenylenediamine‐modified PVC 62 , which also enhanced the pellet CO 2 capture to 1.5 mmol g −1 .
High-performance polyvinyl chloride gel artificial muscle actuator with graphene oxide and plasticizer
A transparent and electroactive plasticized polyvinyl chloride (PVC) gel was investigated to use as a soft actuator for artificial muscle applications. PVC gels were prepared with varying plasticizer (dibutyl adipate, DBA) content. The prepared PVC gels were characterized using Fourier-transform infrared spectroscopy, thermogravimetric analysis, and dynamic mechanical analysis. The DBA content in the PVC gel was shown to have an inverse relationship with both the storage and loss modulus. The electromechanical performance of PVC gels was demonstrated for both single-layer and stacked multi-layer actuators. When voltage was applied to a single-layer actuator and then increased, the maximum displacement of PVC gels (for PVC/DBA ratios of 1:4, 1:6, and 1:8) was increased from 105.19, 123.67, and 135.55µm (at 0.5kV) to 140.93, 157.13, and 172.94µm (at 1.0kV) to 145.03, 191.34, and 212.84µm (at 1.5kV), respectively. The effects of graphene oxide (GO) addition in the PVC gel were also investigated. The inclusion of GO (0.1 wt.%) provided an approximate 20% enhancement of displacement and 41% increase in force production, and a 36% increase in power output for the PVC/ GO gel over traditional plasticizer only PVC gel. The proposed PVC/GO gel actuator may have promising applications in artificial muscle, small mechanical devices, optics, and various opto-electro-mechanical devices due to its low-profile, transparency, and electrical response characteristics.
A novel process for separation of hazardous poly(vinyl chloride) from mixed plastic wastes by froth flotation
Highlights: • A novel method was proposed for separation of PVC by froth flotation. • Calcium hypochlorite treatment improves selectively surface wettablity. • Mechanism of surface treatment was examined by SEM, FTIR and XPS. •Binary plastics with different particle sizes were separated effectively. • Separation of PVC from mixed plastic wastes was obtained. - Abstract: A novel method, calcium hypochlorite (CHC) treatment, was proposed for separation of hazardous poly(vinyl chloride) (PVC) plastic from mixed plastic wastes (MPWs) by froth flotation. Flotation behavior of single plastic indicates that PVC can be separated from poly(ethylene terephthalate) (PET), poly(acrylonitrile-co-butadiene-co-styrene) (ABS), polystyrene (PS), polycarbonate (PC) and poly(methyl methacrylate) (PMMA) by froth flotation combined with CHC treatment. Mechanism of CHC treatment was examined by contact angle measurement, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Under the optimum conditions, separation of PVC from binary plastics with different particle sizes is achieved efficiently. The purity of PC, ABS, PMMA, PS and PET is greater than 96.8%, 98.5%, 98.8%, 97.4% and 96.3%, respectively. Separation of PVC from multi-plastics was further conducted by two-stage flotation. PVC can be separated efficiently from MPWs with residue content of 0.37%. Additionally, reusing CHC solution is practical. This work indicates that separation of hazardous PVC from MPWs is effective by froth flotation.
Electrocatalytic grafting of polyvinyl chloride plastics
Polyvinyl chloride (PVC) plastics require high loadings of plasticizers and stabilizers to achieve commercially useful bulk properties. However, these non-covalent additives leach from PVC over time, resulting in the loss of their tailored functionality. This work details the electrocatalytic functionalization of PVC to covalently graft plasticizing additives directly onto the polymer backbone. Here, mechanistic insights guided the design of electrocatalysts capable of modifying C–Cl bonds of PVC under mild conditions with high selectivity while suppressing side reactions such as elimination and chain scission. Functional groups that mimic PVC plasticizers are covalently installed into the backbone of PVC to create new materials with distinct bulk properties from the original polymer. The degree of polymer grafting is easily controlled by simply changing the redox capacity that is passed during electrolysis. This strategy is employed to create chemically- and leach-resistant PVC materials by directly electrolyzing mixtures of consumer PVC products
Flow-flame interactions causing acoustically coupled heat release fluctuations in a thermo-acoustically unstable gas turbine model combustor
A detailed analysis of the flow-flame interactions associated with acoustically coupled heat-release rate fluctuations was performed for a 10 kW, CH{sub 4}/air, swirl stabilized flame in a gas turbine model combustor exhibiting self-excited thermo-acoustic oscillations at 308 Hz. High-speed stereoscopic particle image velocimetry, OH planar laser induced fluorescence, and OH* chemiluminescence measurements were performed at a sustained repetition rate of 5 kHz, which was sufficient to resolve the relevant combustor dynamics. Using spatio-temporal proper orthogonal decomposition, it was found that the flow-field contained several simultaneous periodic motions: the reactant flux into the combustion chamber periodically oscillated at the thermo-acoustic frequency (308 Hz), a helical precessing vortex core (PVC) circumscribed the burner nozzle at 515 Hz, and the PVC underwent axial contraction and extension at the thermo-acoustic frequency. The global heat release rate fluctuated at the thermo-acoustic frequency, while the heat release centroid circumscribed the combustor at the difference between the thermo-acoustic and PVC frequencies. Hence, the three-dimensional location of the heat release fluctuations depended on the interaction of the PVC with the flame surface. This motivated the compilation of doubly phase resolved statistics based on the phase of both the acoustic and PVC cycles, which showed highly repeatable periodic flow-flame configurations. These include flames stabilized between the inflow and inner recirculation zone, large-scale flame wrap-up by the PVC, radial deflection of the inflow by the PVC, and combustion in the outer recirculation zones. Large oscillations in the flame surface area were observed at the thermo-accoustic frequency that significantly affected the total heat-release oscillations. By filtering the instantaneous reaction layers at different scales, the importance of the various flow-flame interactions affecting the flame area was determined. The greatest contributor was large-scale elongation of the reaction layers associated with the fluctuating reactant flow rate, which accounted for approximately 50% of the fluctuations. The remaining 50% was distributed between fine scale stochastic corrugation and large-scale corrugation due to the PVC. (author)
Characteristics and radiolysis behavior of polyvinylchloride under accelerated proton and γ-irradiation
Here the effect of high energy protons and γ-irradiation on the structural properties, surface-energies, and toxicological properties of polyvinyl chloride (PVC) were studied due to the role PVC products play in many technologies including the nuclear industry. Accelerated 1–4 MeV protons impacting on PVC in vacuum lead to the formation of polyenyl radicals as shown by EPR and to an increase in free surface energy due to functionalization of the surface of the irradiated polymer. γ-irradiation leads to the formation of unsaturated bonds, carbonyl and hydroxyl groups as shown by IR and to the release of HCl. Correlated molecular orbital theory calculations of reaction thermodynamics were used to aid in the development of a mechanism in the absence of oxygen. The formation and accumulation of chromophores and auxochromic groups during γ-radiolysis of PVC leads to a gradual change of the initial white color of the polymer to yellow and then to brown and black with high sensitivity. A mixture of powdered PVC and silicate glue was used to determine the profile of a 60 Co γ-radiation beam on targets with a complex relief. γ-irradiated polymer does not have a local irritating effect due to a single application to the skin of mice in an adhesive mixture at a concentration of up to 5000 mg/kg. γ-radiolysis of PVC powder in air with a dose of up to 1400 kGy does not affect its acute toxicity when administered intragastrically to BDF1 mice. PVC and its γ-irradiated analogs are non-toxic at doses ≤5000 mg/kg.
Highly Stretchable, Ultratough, and Multifunctional Poly(vinyl chloride)-Based Plastics via a Green, Star-Shaped Macromolecular Additive
As one of the most prolifically produced plastics in the world, poly(vinyl chloride) (PVC) suffers from mechanical brittleness and low toughness. Compared with traditional phthalate-type plasticizers, poly(ε-caprolactone) (PCL)-based plasticizers are especially attractive due to their “green” nature and capabilities to achieve improved physical properties. Herein, a stretchable and ultratough PVC-based plastic was achieved by a star-shaped PCL copolymer with a rigid, amino-containing, branched polylactide (N-BPLA) core and a soft PCL shell, that is, RN-SPCLs. With an optimal feed ratio of the CL monomer and N-BPLA core, the RN-SPCL2 can efficiently lower the glass transition temperature (T g ) of PVC plastics, achieving the transition from the “glassy” to “rubbery” state at ambient temperature. The obtained RN-SPCL2/PVC not only shows high extensibility, that is, 453%, but also maintains close to 80% of tensile strength of neat PVC, that is, 30.1 MPa, which is much higher than the previously reported plasticized PVCs. Its overall toughness reaches 92.7 MJ/m 3 , being more than 50-fold higher than neat PVC and 2 to 3 times higher than linear PCL or dibutyl phthalate plasticized PVCs. The important role of star-shaped architecture with a rigid core and flexible PCL shell for RN-SPCL2 in achieving highly stretchable and ultratough PVC plastics is systematically investigated. More interestingly, the as-prepared RN-SPCLs also endow PVC plastics with photoluminescence property and allow homogeneous dispersion of nanosized TiO 2 for significantly enhancing the anti-UV capability.
Controlling selectivity for dechlorination of poly(vinyl chloride) with (xantphos)RhCl
Reaction of poly(vinyl chloride) (PVC) with 5 equiv. of triethyl silane in THF, in the presence of in situ generated (xantphos)RhCl catalyst, results in partial reduction of PVC via hydrodechlorination to yield poly(vinyl chloride-co-ethylene). Increasing catalyst loading or using N,N-dimethylacetamide (DMA) as a solvent both diminished selectivity for hydrodechlorination, promoting competitive dehydrochlorination reactions. Reaction of PVC with 2 equiv. of sodium formate in THF in the presence of (xantphos)RhCl affords excellent selectivity for hydrodechlorination along with complete PVC dechlorination, yielding polyethylene-like polymers. Higher catalyst loadings were necessary to activate PVC towards reduction in this case. In contrast, reaction of PVC with 1 equiv. of NaH in DMA, in the presence of (xantphos)RhCl, exhibited good selectivity for dehydrochlorination, as well as much higher reaction rates. These results combined shed light on the interplay between critical reaction parameters that control PVC's mode of reactivity.
Characterization and flux assessment of airborne phthalates released from polyvinyl chloride consumer goods
Highlights: • Enhanced levels of semi-volatile organic compounds (SVOCs) can affect human health. • The major SVOCs like phthalates are released into indoor by many sources like plasticizers. • This study investigated the emission characteristics of diverse phthalates from plastic/rubber products. • Emission behavior of phthalates is described in relation to several key variables, e.g., types of PVC. The concentrations and fluxes of airborne phthalates were measured from five types of polyvinyl chloride (PVC) consumer products (vinyl flooring, wallcovering, child's toy, yoga mat, and edge protector) using a small chamber (impinger) system. Airborne phthalates released from each of those PVC samples were collected using sorbent (Tenax TA) tubes at three temperature control intervals (0, 3, and 6 h) under varying temperature conditions (25, 40, and 90 °C). A total of 11 phthalate compounds were quantified in the five PVC products examined in this study. To facilitate the comparison of phthalate emissions among PVC samples, their flux values were defined for total phthalates by summing the average fluxes of all 11 phthalates generated during the control period of 6 h. The highest flux values were seen in the edge protector sample at all temperatures (0.40 (25 °C), 9.65 (40 °C), and 75.7 μg m{sup −2} h{sup −1} (90 °C)) of which emission was dominated by dibutyl isophthalate. In contrast, the lowest fluxes were found in wallcovering (0.01 (25 °C) and 0.05 μg m{sup −2} h{sup −1} (40 °C)) and child's toy (0.23 μg m{sup −2} h{sup −1} (90 °C)) at each temperature level. The information regarding phthalate composition and emission patterns varied dynamically with type of PVC sample, controlled temperature, and duration of control.
Thermodynamic analysis on heavy metals partitioning impacted by moisture during the MSW incineration
Highlights: Black-Right-Pointing-Pointer Partitioning of HMs affected by moisture was investigated by thermodynamic analysis. Black-Right-Pointing-Pointer Increase in moisture and in temperature was opposite impact on HMs contribution. Black-Right-Pointing-Pointer The extent of temperature decreased by increase in moisture determines the impact. - Abstract: A thermodynamic calculation was carried out to predict the behavior and speciation of heavy metals (HMs), Pb, Zn, Cu, and Cd, during municipal solid waste (MSW) incineration with the different moisture levels. The calculation was based on the minimization of the total Gibbs free energy of the multi-components and multi-phases closed system reaching chemical equilibrium. The calculation also indicated the reaction directions and tendencies of HMs components. The impacts of chlorine additives (No PVC, 1%PVC, and 5%PVC) and moisture on the behavior of HMs were investigated at different temperature levels in the system (750 Degree-Sign C, 950 Degree-Sign C, and 1150 Degree-Sign C). Furthermore, because the incineration temperature falls down with the increase in moisture in waste, the co-influence of moisture and temperature in combusting MSW on the HMs was also studied with the given chlorine (as 1%PVC + 0.5%NaCl). The results showed that in the non-chlorine system, the impact of the moisture on Pb, Zn, and Cu was not significant, and the ratio of compound transformation was less than 10%, except the Cd compounds at 950 Degree-Sign C and 1150 Degree-Sign C. In the system with low chlorine (as 1%PVC) at constant temperature, the chlorides of HMs (Cd, Pb, Zn, and Cu) transferred to oxides, and when the content of chlorine rose up (as 5%PVC), the ratio of the chlorides of HMs (Cd, Pb, Zn, and Cu) transferring to oxides fell down noticeably. When the moisture varied together with the temperature, the Zn and Cu compounds transferred from chlorides to oxides with increase in moisture as well as decrease in temperature. At the temperature of 700-1000 Degree-Sign C, the impact of temperature on Pb and Cd was little and the moisture was the main factor; while at the temperature of 1000-1200 Degree-Sign C, the impact of increase in moisture and decrease in temperature on Pb and Cd was almost equal and reversed.
Mechanical and morphological characterization of novel vinyl plastisols with epoxidized linseed oil as natural-based plasticizer
Poly(vinyl chloride)(PVC) is one of the most commonly used plastics in the current market due to its low cost and versatility in processing, combined with its satisfactory physical and chemical properties. However, there is an important problem associated to the use of plasticized PVC. This problem is regarding to the toxicity of the most common plasticized used like DOP, DEHP, DINP, due to its possible migration. This problem limits the use of the plasticized PVC in the industry. In this work we have used epoxidized linseed oil (ELO) as a non toxic plasticizer for PVC. This type of natural oil is characterized by acting as both plasticizer and stabilizer of PVC. With this purpose, ELO have been added to PVC. The processing conditions (temperature and time of curing) are vital to determine the final properties of the material. A study of the processing conditions shows the adequate temperature and time to achieve the optimum properties.
Formation and fluidity measurement of supported lipid bilayer on polyvinyl chloride membrane
We prepared an artificial lipid bilayer on a plasticized poly(vinyl chloride) (PVC) membrane on a Si3N4 layer deposited on a Si wafer. We optimized the experimental condition for the fabrication of the PVC membrane, and obtained a PVC membrane with a flat and uniform surface on the scale of several hundreds of micrometer suitable for a substrate for supported lipid bilayers (SLBs). The SLB of 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) was formed on the PVC membrane by the vesicle fusion method. The observation with a conventional epi-fluorescence microscope and a confocal laser scanning microscope gave geometrically uniform images of the SLB on the PVC membrane. The fluidity and the mobile fraction of the SLB was evaluated by the fluorescence recovery after photobleaching method, and compared with that on a thermally oxidized SiO{sub 2}/Si substrate. The SLB on the PVC membrane contained immobile fraction ∼30%, but the diffusion in the mobile fraction was two times faster than that in the SLB on SiO{sub 2}/Si, which had little immobile fraction.
Probiotics for Rectal Volume Variation During Radiation Therapy for Prostate Cancer
Purpose: To investigate the effect of the probiotic Lactobacillus acidophilus on the percentage volume change of the rectum (PVC{sub R}), a crucial factor of prostate movement. Methods and Materials: Prostate cancer patients managed with tomotherapy as a radical treatment were enrolled in the study to take a probiotic capsule containing 1.0 × 10{sup 8} colony-forming units of L acidophilus or a placebo capsule twice daily. Radiation therapy was performed at a dose of 78 Gy in 39 fractions. The PVC{sub R}, defined as the difference in rectal volume between the planning computed tomographic (CT) and daily megavoltage CT images, was analyzed. Results: Forty patients were randomized into 2 groups. The L acidophilus group showed significantly lower median rectal volume and median PVC{sub R} values than the placebo group. L acidophilus showed a significant reduction effect on the PVC{sub R} (P<.001). However, the radiation therapy fraction number did not significantly influence the PVC{sub R}. Conclusions: L acidophilus was useful in reducing the PVC{sub R}, which is the most important determining factor of prostate position, during radiation therapy for prostate cancer.