Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parameter extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Analysis Method for Superconducting Resonator Parameter Extraction with Complex Baseline Removal

A new semi-empirical model is proposed for extracting the quality (Q) factors of arrays of superconducting microwave kinetic inductance detectors (MKIDs). The determination of the total internal and coupling Q factors enables the computation of the loss in the superconducting transmission lines. The method used allows the simultaneous analysis of multiple interacting discrete resonators with the presence of a complex spectral baseline arising from reflections in the system. The baseline removal allows an unbiased estimate of the device response as measured in a cryogenic instrumentation setting.

semi-empirical model↗

Analysis of semivolatile organics in liquid radioactive residue using sorptive stir bar and solvent back-extraction

Current methods for semivolatiles analysis in radioactive samples can produce large volumes of radioactive solvent residue. A method utilizing stir-bar sorptive extraction has been explored in this work for its applicability to radioactive waste samples. This low solvent analytical method may accelerate remediation, minimize hazardous solvent waste, and reduce exposure risk to workers. Organic compounds (polyaromatic hydrocarbons, chlorinated aromatics, and phenolic compounds) were chosen as surrogates for common Liquid Waste System (LWS) contaminants at Savannah River Site (Aiken, SC). Stir-bar extraction parameters (extraction time, matrix modification, and effective pH range) and solvent back extraction parameters (solvent type, volume, and extraction time) were optimized experimentally for the chosen compounds. Affinity of the stir-bar extraction polymer to radionuclides Cs-137 and Am-241 was observed to determine radionuclide concentration effects. The stir-bar method achieved mean recovery of 100 ± 0.7% (1σ), relative to 114 ± 7% using solvent extraction, while reducing weekly method hands-on time by 93.4% and solvent volume consumption by 99.3%. Sensitivity was improved by 378% in simulated tank waste and 278% in real-world LWS matrix, relative to solvent extraction. This work has produced a safe and optimized method for the low solvent analysis of organics in legacy radioactive tank waste by stir-bar sorptive extraction.

GC-MS↗

A Datasheet Driven Unified Si/SiC Compact IGBT Model for N-Channel and P-Channel Devices

This paper presents a unified physics-based insulated-gate bipolar transistor (IGBT) compact model for circuit simulation that predicts the performance of both Si and SiC, n- and p-channel devices. The model can predict the detailed switching waveforms of these technologies based on its charge-based formulation. Further, this compact IGBT model is presented alongside a unique datasheet-driven parameter extraction process. The parameter extraction process enables users to quickly extract model parameters from data typically published without the need of taking physical measurements. The model has been validated with both Si and SiC devices for static and dynamic characteristics. The SiC IGBTs used for validation are a 12.5-kV n-channel device and a 13-kV p-channel device, while the Si IGBT chosen was IXDH30N120 from IXYS Corp. (Milpitas, CA, USA). This is the only IGBT model that predicts the performance of both n- and p-channel, Si and SiC devices, providing more freedom for the development of complex power electronics circuit designs. The convergence of the model has been verified by implementing a complex circuit consisting of both a dc-dc converter and a dc-ac inverter. The results presented here show that the unified model can be used to describe the behavior of a wide range of Si and SiC IGBT circuits. This paper is accompanied by a Verilog-A source code and a power point file demonstrating the model parameter extraction sequence.

42 ENGINEERING↗

Test chips for custom ICs - Six kinds of test structures

Microelectronic test chips contain a number of test structures that are used for a variety of purposes in fabricating integrated circuits. For convenience, their use is divided into six groups: layout-rule evaluating, process-parameter extraction, device-parameter extraction, circuit-parameter extraction, initial-fabrication failure analysis, and reliability failure analysis. A given test structure can be used to gather information in a number of these groups. Examples are given here of the kinds of parameters that can be obtained in each of these groups. A table is included summarizing various device failures common to bulk CMOS and indicating failure mechanisms appearing after wafer fabrication and after stress.

Buehler, M. G.↗

Optimization of Polycyclic Aromatic Hydrocarbon (PAH) Extraction Efficiency Parameters for Sub- and Supercritical Water Extraction (SCWE) Instrument

Polycyclic aromatic hydrocarbons are a class of molecules composed of multiple, bonded benzene rings. As PAHS are believed to be present on Mars, positive confirmation of their presence on Mars is highly desirable. To extract PAHS, which have low volatility, a fluid extraction method is ideal, and one that does not utilize organic solvents is especially ideal for in situ instrumental analysis. The use of water as a solvent, which at subcritical pressures and temperatures is relatively non-Polar, has significant potential. As SCWE instruments have not yet been commercialized, all instruments are individually-built research prototypes: thus, initial efforts were intended to determine if extraction efficiencies on the JPL-built laboratory-scale SCWE instrument are comparable to differing designs built elsewhere. Samples of soil with certified reference concentrations of PAHs were extracted using SCWE as well as conventional Soxhlet extraction. Continuation of the work would involve extractions on JPL'S newer, portable SCWE instrument prototype to determine its efficiency in extracting PAHs.

Okada, Asahi A.↗

Characterization of Electrochemical Behavior for Aqueous Organic Redox Flow Batteries

Use of aqueous redox flow batteries with organic redox-active materials holds great promise for large-scale and sustainable energy storage. The development of low-cost, highly efficient aqueous redox flow batteries lies in a comprehensive understanding of the electrochemical behaviors of redox-active compounds. In this work, an alkaline redox battery with organic dihydroxyphenazine sulfonate (DHPS) anolyte and ferro-/ferricyanide (Fe(CN) 6 ) catholyte is investigated as a typical example of aqueous redox flow batteries using organic redox-active materials. The electrochemical kinetics of DHPS and Fe(CN) 6 are separately characterized using the symmetrical cell design. The resistance components are calculated directly from the experimental measurement. The key kinetic parameters are extracted and compared for DHPS and Fe(CN) 6 electrolytes. The extracted parameters are validated with symmetrical and full flow cell simulations at different operating conditions. Key parameters and internal loss are also compared with all-vanadium redox flow batteries, representing current state of the art. In addition, our extracted key parameters from a symmetrical flow cell are compared with the measured key parameters by cyclic voltammetry, a widely deployed electroanalytical technique. The cell performance prediction of DHPS anolyte on a 780 cm 2 interdigitated cell is made and found the power density is peaked at 475 mW cm -2 at our measurement condition.

25 ENERGY STORAGE↗

Analysis of gas storage and transport in Eagle Ford shale using pressure pulse decay measurements with He, Kr and CO 2

Detailed characterization of gas transport and storage in low-permeability and organic-rich shales is associated with an array of challenges due to the complex morphology of the pore space, representing a broad range of pore sizes, combined with the heterogeneous fabric of the shale matrix. These factors, and their interplay during gas transport and sorption, complicate a) the analysis of shale samples at the laboratory scale (~ up to a ft. In length), and b) the prediction of natural gas production and carbon sequestration potential at larger scales. Here, in this work, tandem experiments with inert (helium – He) and adsorbing (krypton - Kr and carbon dioxide - CO 2 ) gases were performed and analyzed to develop an efficient workflow for characterizing and modeling transport and sorption at the laboratory scale. In particular, pressure pulse-decay (PPD) measurements were conducted on an Eagle Ford shale core sample at room temperature using He, Kr, and CO 2 . PPD measurements with He (a non-sorbing gas) were employed to probe the overall porosity, including natural fractures, microcracks, mesopores, and micropores. A triple-porosity model (TPM) was adopted to interpret the gas transport in the shale sample: The pore space is represented by three interacting continua, including macropores (larger fractures), mesopores (including microcracks), and micropores. To facilitate the application of the TPM, a modified analytical approach is introduced to extract effective transport parameters (in terms of the characteristic time for transport at relevant porosity levels) directly from the PPD measurements with He. To validate the modeling approach, model parameters extracted from two He PPD measurements are demonstrated to provide excellent agreement with a 3rd He PPD measurement performed at a higher pressure. The effective transport parameters, extracted from the He experiments, were subsequently converted for application to the Kr and CO 2 PPD experiments, by accounting for relevant transport modes and differences in fluid properties. Excess adsorption isotherms were extracted from the equilibrium pressures of the Kr and CO 2 PPD experiments using the He pore volume as a baseline. These adsorption isotherms were then integrated into the TPM to predict combined gas transport and sorption for Kr and CO 2 , with transport coefficients translated from the He measurements. The predictions for Kr and CO 2 are demonstrated to be in excellent agreement with the experimental observations. This, in turn, demonstrates that the proposed analytical approach provides for an effective characterization of mass transfer rates in shales, that can be applied directly in a TPM representation of mass transfer and sorption.

58 GEOSCIENCES↗

Datasheet Driven Silicon Carbide Power MOSFET Model

A compact model for SiC Power MOSFETs is presented. The model features a physical description of the channel current and internal capacitances and has been validated for dc, CV, and switching characteristics with measured data from a 1200-V, 20-A SiC power MOSFET in a temperature range of 25 degrees C to 225 degrees C. The peculiar variation of on-state resistance with temperature for SiC power MOSFETs has also been demonstrated through measurements and accounted for in the developed model. In order to improve the user experience with the model, a new datasheet driven parameter extraction strategy has been presented which requires only data available in device datasheets, to enable quick parameter extraction for off-the-shelf devices. Excellent agreement is shown between measurement and simulation using the presented model over the entire temperature range.

Mudholkar, M↗

Constitutive parameter de-embedding using inhomogeneously-filled rectangular waveguides with longitudinal section modes

Constitutive parameter extraction from S parameter data using a rectangular waveguide whose cross section is partially filled with a material sample as opposed to being completely filled was examined. One reason for studying a partially filled geometry is to analyze the effect of air gaps between the sample and fixture for the extraction of constitutive parameters. Air gaps can occur in high temperature parameter measurements when the sample was prepared at room temperature. Single port and two port measurement approaches to parameter extraction are also discussed.

Park, A.↗

Water dynamics in C–S–H and M-S-H cement pastes: A revised jump-diffusion and rotation-diffusion model

The Quasi-Elastic Neutron Scattering (QENS) spectra from four cement pastes are re-analyzed by a new revised jump-diffusion and rotation-diffusion model (rJRM). From the QENS fit, it can be seen that the rJRM is an improved model to fit QENS spectra within the whole detected neutron energy transfer and scattering vector. By the rJRM fitting, the structure parameters extracted from QENS spectra show that both the additives aluminum-silicate nanotubes (ASN) and carboxyl group functionalized ASN (ASN-COOH) can improve magnesium-silicate-hydrate (M-S-H) toward calcium-silicate-hydrate (C–S–H) direction in mechanical properties, but the improvement is weakened with decreasing temperatures. The extracted dynamical parameters show that there is a dynamic anomaly near 230 K in not only translational but also rotational diffusion of water confined in all the investigated samples. In conclusion, the anomaly in rotational diffusion is new compared with those results obtained by the QENS fit using other models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft sample deformation, damage and induced electromechanical property changes in contact- and tapping-mode atomic force microscopy

Probe-induced soft sample damage in atomic force microscopy (AFM), as well as the resulting alteration of local mechanical and electrical properties of the material are explored, specifically comparing contact-mode and intermittent-contact-mode imaging methods. In our experiments, performed on conductive polymer films, induced changes are present in contact-mode imaging while they are negligible or absent in tapping-mode imaging. Here, to understand this result, a viscoelastic parameter extraction is performed, which suggests that permanent sample deformation can readily occur for tip-sample interactions with a duration on the timescale of contact-mode interactions. Using the extracted viscoelastic parameters, a dynamic AFM simulation is conducted, which suggests that the material responds more elastically with reduced or absent sample damage in tapping-mode AFM, due to the higher rate of mechanical deformation and shorter timescales.

42 ENGINEERING↗

Extraction from flight data of longitudinal aerodynamic coefficients in maneuvering flight for F-8C aircraft

Flight-test data were used to extract the longitudinal aerodynamic parameters of the F-8C aircraft. The aircraft was trimmed in a steady turn at angles of attack of approximately 9 deg and 13 deg at Mach numbers of 0.7 and 0.8. The parameters extracted resulted in a good match to the flight data and the values obtained were reasonable. The values were further verified by comparing the period and time to damp to half-amplitude, as calculated by using the extracted parameter values, with the period and time to damp to half-amplitude actually measured from the flight data traces. These results show that for the set of data examined, a mathematical model using linear aerodynamics was adequate to describe the response motions at the test angles of attack.

Suit, W. T.↗

Extraction of Modal Parameters from Spacecraft Flight Data

The modeled response of spacecraft systems must be validated using flight data as ground tests cannot adequately represent the flight. Tools from the field of operational modal analysis would typically be brought to bear on such structures. However, spacecraft systems have several complicated issues: 1. High amplitudes of loads; 2. Compressive loads on the vehicle in flight; 3. Lack of generous time-synchronized flight data; 4. Changing properties during the flight; and 5. Major vehicle changes due to staging. A particularly vexing parameter to extract is modal damping. Damping estimation has become a more critical issue as new mass-driven vehicle designs seek to use the highest damping value possible. The paper will focus on recent efforts to utilize spacecraft flight data to extract system parameters, with a special interest on modal damping. This work utilizes the analysis of correlation functions derived from a sliding window technique applied to the time record. Four different case studies are reported in the sequence that drove the authors understanding. The insights derived from these four exercises are preliminary conclusions for the general state-of-the-art, but may be of specific utility to similar problems approached with similar tools.

James, George H.↗

Rate-equation modelling and ensemble approach to extraction of parameters for viral infection-induced cell apoptosis and necrosis

We develop a theoretical approach that uses physiochemical kinetics modelling to describe cell population dynamics upon progression of viral infection in cell culture, which results in cell apoptosis (programmed cell death) and necrosis (direct cell death). Several model parameters necessary for computer simulation were determined by reviewing and analyzing available published experimental data. By comparing experimental data to computer modelling results, we identify the parameters that are the most sensitive to the measured system properties and allow for the best data fitting. Our model allows extraction of parameters from experimental data and also has predictive power. Using the model we describe interesting time-dependent quantities that were not directly measured in the experiment and identify correlations among the fitted parameter values. Numerical simulation of viral infection progression is done by a rate-equation approach resulting in a system of “stiff” equations, which are solved by using a novel variant of the stochastic ensemble modelling approach. The latter was originally developed for coupled chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗