Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Estimating Large Global Significances with a New Monte Carlo Extrapolation Method

In particle physics, it is needed to evaluate the possibility that excesses of events in mass spectra are due to statistical fluctuations as quantified by the standards of local and global significances. Without prior knowledge of a particle’s mass, it is especially critical to estimate its global significance. The usual approach is to count the number of times a significance limit is exceeded in a collection of simulated Monte Carlo (MC) “toy experiments”. To demonstrate this conventional method for global significance, we performed simulation studies according to a recent Compact Muon Solenoid (CMS) result to show its effectiveness. However, this counting method is not practical for computing large global significances. To address this problem, we developed a new “extrapolation” method to evaluate the global significance. We compared the global significance estimated by our new method with that of the conventional approach, and verified its feasibility and effectiveness. This method is also applicable for cases where only small toy MC samples are available. In this approach, the significance is calculated based on p-values, assuming symmetrical Gaussian distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Revisiting the influence of Ni particle size on the hydrogenation of CO 2 to CH 4 over Ni/CeO 2

Nickel nanoparticles were supported on CeO 2 and evaluated in the hydrogenation of CO 2 to CH 4 at 538 K and 1 atm. Chemisorption of H 2 was used to estimate the average Ni particle size, which ranged from 1.3 to 17 nm. The apparent activation energy for CH 4 formation and turnover frequency for CO 2 conversion was independent of Ni particle size. The smallest Ni particles (1.3 nm) were less selective to CH 4 . Comparisons to alumina-supported Ni reveal the same performance as Ni/CeO 2 when normalized to active Ni atoms counted by H 2 chemisorption. A beneficial effect of ceria relative to alumina is the enhanced reducibility of Ni as evaluated by H 2 temperature-programmed reduction. The constancy of the turnover frequency on Ni particles suggests the acid-base and/or redox properties of the support do not play a significant role in the CO 2 methanation reaction under the conditions of study, which contrasts many earlier works.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All loop scattering as a counting problem

Abstract This is the first in a series of papers presenting a new understanding of scattering amplitudes based on fundamentally combinatorial ideas in the kinematic space of the scattering data. We study the simplest theory of colored scalar particles with cubic interactions, at all loop orders and to all orders in the topological ’t Hooft expansion. We find novel integral formulas for the amplitudes of this theory, with no trace of the conventional sum over Feynman diagrams, but instead determined by a beautifully simple counting problem attached to any order of the topological expansion. These results represent a significant step forward in the decade-long quest to formulate the fundamental physics of the real world in a radically new language, where the rules of spacetime and quantum mechanics, as reflected in the principles of locality and unitarity, are seen to emerge from deeper mathematical structures.

1/N Expansion↗

Energy-enhanced expansion of the standard model effective field theory

We formalize energy-scaling arguments in the standard model effective field theory (SMEFT) to estimate the effects of operators up to dimension ten. Our approach relies on weakly coupled UV completions with no presumed large hierarchies between the Wilson coefficients. We introduce a classification based on the number of external legs and an energy-counting parameter. We establish a dual expansion in 𝑣/Λ and 𝐸/Λ. Extending to four-, five-, and six-particle vertices, our framework highlights energy-enhanced operators that dominate high-energy processes at the High Luminosity-Large Hadron Collider. This organization streamlines experimental analyses to only include operators with energetic impact in their analyses and enhances the discoverability of new physics within the SMEFT framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark counts in optical superconducting transition-edge sensors for rare-event searches

Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for their high single-photon detection efficiency and low background. This makes TESs ideal for particle-physics experiments searching for rare events. In this work, we present a comprehensive characterization of the background in optical TESs, distinguishing three types of events: electrical-noise, high-energy, and photonlike events. We introduce computational methods to automate the classification of events. We experimentally verify and simulate the source of the high-energy events. We also isolate the photonlike events, the expected signal in dielectric haloscopes searching for dark-matter dark photons, and achieve a photonlike dark-count rate of 3.6× 10 − 4 in the 0.8–3.2 eV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Electrochemical Stability Window of an All-Solid-State Composite Cathode via a Novel Operando Tender XPS Setup

All-solid-state batteries (ASSBs) have the potential to provide greater energy density than conventional batteries based on liquid electrolytes. Here, an operando ASSB cell setup for tender X-ray photoelectron spectroscopy (XPS) was developed, and the interface of a Ni-rich layered transition metal oxide cathode active material (CAM) and an Li 6 PS 5 Cl (LPSCl) solid electrolyte (SE) was evaluated during initial charge/discharge cycles. After validating the cell performance against a conventional pouch cell operated at high compression, intermittent galvanostatic cycling was performed, and XPS data were recorded as a function of state of charge (SOC). Upon the initial charge of the cell to ≈3.3 V Li , the LPSCl appears to decompose into LiCl, Li 3 PS 4 , and polysulfides, whose amount gradually increases with potential. Upon further charge, at a potential higher than ≈3.8 V Li , initially, present sulfate and sulfite impurities decompose, and at ≈74% SOC (corresponding to a cathode potential of ≈4.10 V Li ), surface reconstruction of the CAM particles due to lattice oxygen release is detected. In addition, at potentials beyond ≈4.6 V Li , a decrease of the S 1s counts of the sum of the LPSCl, the thiophosphate, and polysulfide species suggests the formation of elemental sulfur that is lost via sublimation into the vacuum chamber.

25 ENERGY STORAGE↗

Generalized eikonal identities for charged currents

Abstract We discuss QED radiative corrections to contact operators coupling two heavy fields and one light field. These operators appear ubiquitously in weak interactions with nuclei such as beta decay and neutrino nucleus scattering. New eikonal identities are derived in the static limit (i.e., neglecting nuclear recoil) that allow for manifest power counting of enhancements proportional to the charge of the nucleus. We apply these new identities to nuclear beta decays and find that the “independent particle model” used by Jaus, Rasche, Sirlin & Zucchini is closely related, though not identical, to a model independent effective field theorcalculation.

Physics↗

Discriminator Threshold Study for Scint 1

During electronics testing at NSRL, the fluence/spill is recorded from the QC1 chamber. This chamber, which is a permanent fixture on the NSRL beamline, requires calibration from an external radiation detector that can measure ion flux directly. A 1.0 × 1.0 × 0.5 cm 3 scintillator is used at the testing location to calibrate all NSRL beams for electronic experiments. A calibration factor is derived by comparing the ions observed by the scintillator and QC1 during an exposure of at least 10 5 scintillator counts or total ions.

43 PARTICLE ACCELERATORS↗

ASCR Workshop Position Paper: Challenges and Opportunities in High Energy Physics

High energy particle physics and cosmology concern themselves with estimating fundamental parameters of nature, such as the masses and interactions of fundamental particles like the Higgs boson and the rate of expansion of the universe. In doing so, they analyze exabyte-scale datasets, some of the largest in all of science, and face many challenges in subsequent data analysis. These challenges are shared between the two disciplines, but we focus on particle physics to highlight one specific domain. In particle physics, the standard method for estimating parameters involves performing Monte Carlo (MC) integration as a function of both parameters of interest and nuisance parameters using an expensive simulator, counting the number of observed collision events (i.i.d. samples) from an experiment in the corresponding integration domains, and forming a Poisson likelihood function. This likelihood function is then used in a Frequentist manner to construct a maximum likelihood point estimate (MLE) and confidence set for the parameters. To sufficiently populate the high-dimensional integration domains, simulators consume billions of CPU-hours annually and produce hundreds of petabytes of intermediate output data. Several techniques have been developed to: optimize definitions of the integration domains so as to be maximally sensitive to a particular subset of parameters, efficiently estimate the integrals, and build robust surrogate models by interpolating between integral evaluations at different parameter points. One can view this whole endeavor as classical Simulation-Based Inference (SBI).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

A single-photon lidar observes atmospheric clouds at decimeter scales: resolving droplet activation within cloud base

Abstract Clouds, crucial for understanding climate, begin with droplet formation from aerosols, but observations of this fleeting activation step are lacking in the atmosphere. Here we use a time-gated time-correlated single-photon counting lidar to observe cloud base structures at decimeter scales. Results show that the air–cloud interface is not a perfect boundary but rather a transition zone where the transformation of aerosol particles into cloud droplets occurs. The observed distributions of first-arriving photons within the transition zone reflect vertical development of a cloud, including droplet activation and condensational growth. Further, the highly resolved vertical profile of backscattered photons above the cloud base enables remote estimation of droplet concentration, an elusive but critical property to understanding aerosol–cloud interactions. Our results show the feasibility of remotely monitoring cloud properties at submeter scales, thus providing much-needed insights into the impacts of atmospheric pollution on clouds and aerosol-cloud interactions that influence climate.

54 ENVIRONMENTAL SCIENCES↗

ORNLERASE - EPA COUNTS PER MINUTE CALCULATOR CONVERSION FACTORS

This database is used in the EPA's Superfund Counts Per Minute (CPM) Calculator (https://epa-cpm.ornl.gov/index.html). This database contains conversion factors used in the calculator that help users estimate the expected radiation detector reading, in counts per minute (CPM), corresponding to a measured radioactivity level reported in either pCi/cm² or pCi/g. Because surface contamination and volumetric contamination behave differently, the tool uses separate conversion processes, each based on Monte Carlo N-Particle (MCNP)–derived conversion factors. The CPM Calculator supports conversions for a range of common environmental media—including soil, steel, glass, drywall, concrete, and wood—to generate detector-ready CPM values. The primary goal of this tool is to enable more efficient, real-time field measurements, reducing reliance on laboratory analyses and ultimately saving both time and money during Superfund assessments.

Dolislager, Fred [ORNL] (ORCID:0009000325477921)↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of a Novel Radiochemical Mix Diagnostic for Fusion Implosions at the National Ignition Facility

Mixing of the ablator material into the fuel of an inertial confinement fusion implosion reduces compression and enhances radiative losses, preventing ignition. Here, we describe a novel use of charged-particle radiochemistry to measure the ablator mix in contact with the fusion hot spot. The capsule uses a graded Be-Cr layer to increase the confinement of the hot spot. 52 Mn and 51 Cr isotopes are collected from the implosion and counted, and the ratio is related to the amount of Cr mixed into the hot spot. Thus, a new diagnostic to determine the degradation due to mix on fusion implosions has been developed.

MacLaren, S. A. [Lawrence Livermore National Labor↗

Ratio of 1,275 and 186 keV Gamma Ray Count Rates for Age Determination of Material in UF 6 Cylinders

In this work, a method for using ratios of passive gamma ray measurements to determine the time since the filling of UF 6 cylinders was explored. This method uses the 186 keV gamma ray emitted by 235 U and the 1,275 keV gamma ray that results from interactions of alpha particles in fluorine. Studies were made using MCNP models of both 30B cylinders and smaller 5A cylinders. Results indicate that for enrichments at or above that of natural uranium, this approach may provide a method for determining age up to 10 years or identifying whether the age is greater than 10 years, even if the uranium enrichment is unknown. The calculated results show the same behavior as the results of a recent measurement campaign, indicating the possibility of using this method for real-world cylinders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗