Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Phase space distribution of halo particles and detection of WIMPS

We calculate the velocity distribution of halo particles using realistic models for the density profiles of the Galactic disk, spheroid, and halo components. We get the resulting velocity distribution, which is different from the Maxwellian distribution of isothermal halo. We investigate the consequences concerning the time averaged count rate and the amplitude of the annual modulation in WIMPS detection experiments. Compared to the previous estimate based on the Maxwellian distribution, the time averaged count rate is up to 40 percent larger. On the other hand, the amplitude of the annual modulation is up to a factor of two larger.

Ryu, Dongsu↗

Exploring results of the possibility on detecting cosmic ray particles by acoustic way

It has been demonstrated experimentally and theoretically that high energy particles produce detectable sounds in water. However, no one has been able to detect an acoustic signal generated by a high energy cosmic ray particle in water. Results show that transient ultrasonic signals in a large lake or reservoir are fairly complex and that the transient signals under water may arise mainly from sound radiation from microbubbles. This field is not explored in detail. Perhaps, the sounds created by cosmic ray particles hide in these ultrasonic signals. In order to develop the technique of acoustic detection, it is most important to make a thorough investigation of these ultrasonic signals in water.

Jiang, Y.↗

Performance Test of Laser Velocimeter System for the Langley 16-foot Transonic Tunnel

An investigation in the Langley 16-Foot Transonic Tunnel has been conducted in which a laser velocimeter was used to measure free-stream velocities from Mach 0.1 to 1.0 and the flow velocities along the stagnating streamline of a hemisphere-cylinder model at Mach 0.8 and 1.0. The flow velocity was also measured at Mach 1.0 along the line 0.533 model diameters below the model. These tests determined the performance characteristics of the dedicated two-component laser velocimeter at flow velocities up to Mach 1.0 and the effects of the wind tunnel environment on the particle-generating system and on the resulting size of the generated particles. To determine these characteristics, the measured particle velocities along the stagnating streamline at the two Mach numbers were compared with the theoretically predicted gas and particle velocities calculated using a transonic potential flow method. Through this comparison the mean detectable particle size (2.1 micron) along with the standard deviation of the detectable particles (0.76 micron) was determined; thus the performance characteristics of the laser velocimeter were established.

Meyers, J. F.↗

Detecting Contaminant Particles Acoustically

Apparatus "listens" for particles in interior of complex turbomachinery. Contact microphones are attached at several points on pump housing. Acoustic transducer also attached to housing to excite entire pump with sound. Frequency of sound is slowly raised until pump resonates. Microphones detect noise of loose particles scraping against pump parts. Such as machining chips in turbopumps or other machinery without disassembly.

Wyett, L. M.↗

Definition of a near real-time microbiological monitor for application in space vehicles

The concepts and methodologies for microbiological monitoring in space are examined, focusing on the determination of the requirements of a near real-time microbiological monitor. Results are presented from the technical evaluation of five microbiological monitor concepts, including cultural methods, single cell detection, biomolecular detection, specific product detection, and general molecular composition. Within these concepts, twenty-eight specific methodolgies were assessed and the five candidate methodologies with the highest engineering and feasibility scores were selected for further evaluations. The candidate methodologies are laser light scattering, primary fluorescence, secondary fluorescence, volatile product detection, and electronic particle detection. The advantages and disadvantages of these five candidate methodologies are discussed.

Kilgore, Melvin V., Jr.↗

Detecting Foreign Particles in Wind Tunnels

Simple scratch test tells whether particles, which distort results, present in test. Detector developed for tests of abrasion resistance of flexible insulation blankets. Now, when detector indicates particles present in test, results interpreted accordingly. Small pits and scratches on metal foil indicate particles struck surface during wind-tunnel test. Detector used in tests of paints and coatings to determine whether abrasive particles present.

Sharp, H. L.↗

Test results of a prototype dielectric microcalorimeter

The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

Pfafman, T. E.↗

Dosimetry of heavy ions by use of CCD detectors

The design and the atomic composition of Charge Coupled Devices (CCD's) make them unique for investigations of single energetic particle events. As detector system for ionizing particles they detect single particles with local resolution and near real time particle tracking. In combination with its properties as optical sensor, particle transversals of single particles are to be correlated to any objects attached to the light sensitive surface of the sensor by simple imaging of their shadow and subsequent image analysis of both, optical image and particle effects, observed in affected pixels. With biological objects it is possible for the first time to investigate effects of single heavy ions in tissue or extinguished organs of metabolizing (i.e. moving) systems with a local resolution better than 15 microns. Calibration data for particle detection in CCD's are presented for low energetic protons and heavy ions.

Schott, J. U.↗

Preparation of calibrated test packages for particle impact noise detection

A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.

Source record↗

SERENA: Particle Instrument Suite for Determining the Sun-Mercury Interaction from BepiColombo

The ESA-JAXA BepiColombo mission to Mercury will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric particle dynamics at Mercury as well as their interactions with solar wind, solar radiation, and interplanetary dust. The particle instrument suite SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) is flying in space on-board the BepiColombo Mercury Planetary Orbiter (MPO) and is the only instrument for ion and neutral particle detection aboard the MPO. It comprises four independent sensors: ELENA for neutral particle flow detection, Strofio for neutral gas detection, PICAM for planetary ions observations, and MIPA, mostly for solar wind ion measurements. SERENA is managed by a System Control Unit located inside the ELENA box. In the present paper the scientific goals of this suite are described, and then the four units are detailed, as well as their major features and calibration results. Finally, the SERENA operational activities are shown during the orbital path around Mercury, with also some reference to the activities planned during the long cruise phase.

Mercury’s environment↗

SERENA: Particle Instrument Suite for Determining the Sun-Mercury Interaction from BepiColombo

The ESA-JAXA BepiColombo mission to Mercury will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric particle dynamics at Mercury as well as their interactions with solar wind, solar radiation, and interplanetary dust. The particle instrument suite SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) is flying in space on-board the BepiColombo Mercury Planetary Orbiter (MPO) and is the only instrument for ion and neutral particle detection aboard the MPO. It comprises four independent sensors: ELENA for neutral particle flow detection, Strofio for neutral gas detection, PICAM for planetary ions observations, and MIPA, mostly for solar wind ion measurements. SERENA is managed by a System Control Unit located inside the ELENA box. In the present paper the scientific goals of this suite are described, and then the four units are detailed, as well as their major features and calibration results. Finally, the SERENA operational activities are shown during the orbital path around Mercury, with also some reference to the activities planned during the long cruise phase.

S. Orsini↗

Can we detect antimatter from other galaxies

A novel particle detection technique employing well established principles of high order quantum electrodynamics for searching for antimatter in cosmic rays is described, and shown to have both collecting power and resolution superior to conventional alternatives. By taking into account various estimates of the metagalactic cosmic-ray energy density, and the possible modulation of metagalactic cosmic rays by a galactic wind within the framework of the dynamical halo model, it is shown that the experiment proposed would be the first to be sensitive to the presence of extragalactic antimatter.

Ahlen, S. P.↗

Results to be expected from light scattering dust analyzer during a rendezvous mission

The light scattering principle for particle detection is customary for the measurement of aerosols. Light scattering techniques can be applied to mixtures of particles (nephelometers) and to single particles as well. Measuring particle mixtures simplify detection because of the higher intensity level, however, information concerning the individual particle is lost. To provide well defined conditions over the whole rendezvous period, i.e., constant illumination beam and unchangeable scattering angle, the use of an artificial light source (instead of the sun) and a scattering volume located within the S/C is desirable. Considering this and the relatively low particle densities to be expected, the measurement of particle mixtures must be excluded.

Zerull, R. H.↗

Charged-particle lunar environment experiment

Charged particle lunar environment experiment of Apollo 14 detecting particle fluxes at lunar surface resulting from wide range of lunar surface, magnetospheric, and interplanetary data

Obrien, B. J.↗

Particle data reduction in Japan

The characterization of atomized particles generated by various atomizer and the mechanics of their evaporation and combustion processes were studied. The need existed for visualizing the internal structure of flames including evaporation and combustion processes as well as for a better way of understanding spray particle generation mechanisms and internal structures. A particle sizer based on Fraunhofer diffraction for detecting particle size and in-line Fraunhofer holograms for observation of local spray particles were used. A novel visualizing technique based on Computer Technology was developed and is discussed.

Nakayama, Mitsushige↗