Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive Containment Cooling System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

R&D Roadmap for Enhanced Resilient Plant Systems, Metrics, Scenarios, Risk Analysis, and Modeling and Simulation

The nuclear industry and the U.S. Department of Energy are jointly developing accident tolerant fuel (ATF) which has the potential to greatly improve the safety and economic performance of the current fleet of NPPs. The combination of ATF with the optimal use of FLEX equipment (deployed as an industry response to the Fukushima Daiichi Nuclear Power Plant (NPP) accident in 2012), enhancements on plant components and systems, incorporation of augmented cooling systems or new passive cooling systems, and improvements in fuel cycle efficiency, have the potential to render the NPPs more efficient and resilient to events (both internally and externally initiated) that have the potential to challenge the integrity of the fuel or plant containment. In this report, combinations of these plant improvements are called Enhanced Resilient Plant Systems. In order to accelerate the development and deployment of the components that comprise Enhanced Resilient Plant Systems, a well-integrated toolkit that is fuel/clad-, fuel cycle-, systems-, and scenario-centric is required to provide a ready platform for the analysis of the advanced ATF fuel and cladding materials that are being developed, as well as plant systems modifications to achieve enhanced resiliency. Since the deployment of these enhancements will comprise a risk/benefit tradeoff of their impacts on plant safety and economics, the envisioned toolkit will need to be capable to characterizing the multidimensional aspects associated with these evaluations and provide decision-makers with information that can optimize the technological, economic, and safety benefits that are to be obtained. The Risk-Informed Systems Analysis (RISA) Pathway of the DOE Light Water Reactor Sustainability (LWRS) Program initiated several research tasks to develop analytical capabilities to support the industry in the transition to the ATF and Enhanced Resilient Plant Systems. The general idea behind the initiative is the development of an integrated evaluation approach which combines the plant probabilistic risk assessment (PRA) models with Multi-Physics Best Estimate Plus Uncertainty (MP-BEPU) analyses in a seamless fashion. The integrated evaluation framework aims at enabling plant system configuration variations to be studied with speed and precision, including detailed risk and benefit assessments of introducing ATF and Enhanced Resilient Plant Systems into current LWR plants to achieve both safety and operational performance enhancements. The focus of this report is to present an integrated research and development (R&D) roadmap to identify and perform high value evaluations of proposed ATF and Enhanced Resilient Plant Systems concepts to identify both the technical (e.g. benefits to risk, safety, and operational margins) and the economic (i.e. business and cost) elements associated with industry adoption of the technology. The integrated evaluation approach will be developed to support the development, testing, qualification, licensing, and deployment of ATF and Enhanced Resilient Plant Systems technology that is capable of achieving substantial safety and economic improvements as well as timely widespread adoption by the US nuclear industry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Solid Chlorate Backup Oxygen Delivery System for the International Space Station

The International Space Station (ISS) Program requires that there always be a 45 calendar day contingency supply of breathing oxygen. In the early assembly stages, there is only one flight system, the Russian Solid Fuel Oxygen Generator (SFOG), that can meet that requirement. To better ensure the contingency oxygen supply, the Crew and Thermal Systems Division was directed to develop a flight hardware system that can meet all contingency oxygen requirements for ISS. Such a system, called the Backup Oxygen Candle System (BOCS), has been built and tested. The BOCS consists of 33 chlorate candles, a thermal containment apparatus, support equipment and packaging. The thermal containment apparatus utilizes the O2 produced by the candle as the motive stream in an ejector to passively cool the candle during operation.

Graf, John↗

Comparison of Alternatives to the 2004 Vacuum Vessel Heat Transfer System

A study comparing different alternatives for the Vacuum Vessel Primary Heat Transfer System has been completed. Three alternatives were proposed in a Project Change Request (PCR-190) by relocating the heat exchangers (HXs) from the roof of the Tokamak building to inside the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The study evaluated the three alternatives and recommended modifications to one of them to arrive at a preferred configuration that included relocating the HXs inside the Tokamak building but outside the VVPSS tank as well as including a small safety-rated pump and HX in parallel to the main circulation pump and HX. The Vacuum Vessel (VV) Primary Heat Transfer System (PHTS) removes heat generated in the VV during normal operation (10 MW, pulsed power) as well as the decay heat from the VV itself and from the structures/components attached to the VV (first wall, blanket, and divertor {approx}0.48 MW peak). Therefore, the VV PHTS has two safety functions: (1) contain contaminated cooling water (similar to the other PHTSs) and (2) provide passive cooling during an accident event. The 2004 design of the VV PHTS consists of two independent loops, each loop cooling half of the 18 VV segments with a nominal flow of 475 kg/s of water at about 1.1 MPa and 100 C. The total flow for both loops is 950 kg/s. Both loops are required to remove the heat load during normal plasma operation. During accident conditions, only one loop is needed to remove by natural convection (no pump needed) the decay heat of the complete VV and attached components. The heat is transferred to heat exchanger (HXs) located on top of the roof, outside the Tokamak building. These HXs are air-to-water (A/W) HXs. Three alternatives have been proposed for this cooling system. For a detailed discussion of these alternatives, please refer to Project Change Request, PCR-190 (Ref. 1). A brief introduction is given here. Alternative 1 includes only one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump. In addition, this alternative has two natural circulation safety loops. Both the safety and main loops supply water to the bottom of the VV with six branch lines and collect the heated water at the top of the vessel through six branches. The distribution headers are located in the lower pipe chase and the collection headers in the upper pipe chase. Each of these loops (one main and two emergency) has a HX mounted in the Vacuum Vessel Pressure Suppression System (VVPSS) tank. The main HX is cooled using either Component Cooling Water System (CCWS) or Chilled Water System (CHWS) water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 1 taken from PCR-190. Alternative 2 is exactly the same as Alternative 1 except that there is only one emergency loop and one emergency HX. See Fig. 2 taken from PCR-190. Alternative 3 also has one main forced circulation loop with a small safety-rated pump in parallel with the main circulation pump and one natural circulation safety loop. In this case, both the safety and main loops supply water to the top of the VV with three branch lines and collect the heated water at the top of the vessel through three branches. Here, the distribution header is located in the upper pipe chase as is the collection header. As before, each of these loops has a HX mounted in the VVPSS tank. The main HX is cooled using either CCWS or CHWS water, and the emergency HXs are cooled by natural circulation of the VVPSS water. See Fig. 3 taken from PCR-190. The preferred configuration is developed by selecting specific attributes of the other configurations analyzed and the logic for selecting this configuration is discussed at the end of the document. It is a modification of Alternative 2 that eliminates the separate safety loop, but incorporates a small safety rated HX and pump in parallel with the main HX and pump. It uses 18 inlet and 18 outlet branches (as did the 2004 design) and locates the HXs outside of the VVPSS tank. Tables 1 and 2 examine alternatives to the 2004 VV heat transfer system design that were proposed in PCR-190, as well as the preferred option.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AMS-02 Cryocooler Baseline Configuration and Engineering Model Qualification Test Results

Four Sunpower M87N Stirling-cycle cryocoolers will be used to extend the lifetime of the Alpha Magnetic Spectrometer-02 (AMS-02) experiment. The cryocoolers will be mounted to the AMS-02 vacuum case using a structure that will thermally and mechanically decouple the cryocooler from the vacuum case while providing compliance to allow force attenuation using a passive balancer system. The cryocooler drive is implemented using a 60Hz pulse duration modulated square wave. Details of the testing program, mounting assembly and drive scheme will be presented. AMS-02 is a state-of-the-art particle physics detector containing a large superfluid helium-cooled superconducting magnet. Highly sensitive detector plates inside the magnet measure a particle s speed, momentum, charge, and path. The AMS-02 experiment, which will be flown as an attached payload on the International Space Station, will study the properties and origin of cosmic particles and nuclei including antimatter and dark matter. Two engineering model cryocoolers have been under test at NASA Goddard since November 2001. Qualification testing of the engineering model cryocooler bracket assembly is near completion. Delivery of the flight cryocoolers to Goddard is scheduled for September 2003.

Banks, Stuart↗

Passive cooling to cold shutdown

A cooling system for a reactor module includes a reactor pressure vessel that houses primary coolant and a steam generator that lowers a temperature of the reactor pressure vessel by transferring heat from the primary coolant to a secondary coolant. The steam generator releases at least a portion of the secondary coolant as steam. Additionally, the cooling system includes a containment vessel that at least partially surrounds the reactor vessel in a containment region. The containment region is dry during normal operation of the reactor module. A controller introduces a source of water into the containment region in response to a non-emergency shut down of the reactor module. The source of water is located external to the containment vessel, and the water is introduced into the containment region after the steam generator has initially lowered the temperature of the reactor pressure vessel in response to releasing the steam.

Keller, Michael↗

ESBWR response to an extended station blackout/loss of all AC power

U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackouts for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event. Beyond 7 days, only a few simple actions are needed to cope with the SBO for an indefinite amount of time. The operation of the ICS as the primary success path for mitigation of an SBO, allows for near immediate plant restart once power is restored. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flux pinning concepts for on-orbit capture and orientation of an MSR orbiting sample container

Concepts for on-orbit capture and orientation of a Mars orbiting sample container (OS) using flux pinning were developed as candidate technologies for potential Mars Sample Return (MSR). The systems consist of a set of type-II superconductors field cooled below their critical temperature using a cryocooler, and operate on an orbiting sample container with a series of permanent magnets spaced around the exterior, along with an integrated layer of shielding to preserve the magnetic properties of the returned samples. Benefits of the approaches include passive, non-contact capture and orientation, as well as a reduction in the number of actuators relative to various mechanical methods.

Chiu, Chi Yeung↗

Integrated FHR technology development: Tritium management, materials testing, salt chemistry control, thermal hydraulics and neutronics, associated benchmarking and commercial basis

This report summarizes the results of a 3-year Integrated Research Project (IRP) sponsored by the U.S. Department of Energy to address major technical challenges in the development of the Fluoride-salt-cooled High-temperature Reactor (FHR). The IRP universities included the Massachusetts Institute of Technology (MIT), the University of California at Berkeley (UCB), the University of Wisconsin (UW), and the University of New Mexico (UNM). The FHR is a new reactor concept less than 20 years old that combines (1) a clean fluoride salt coolant, (2) the graphite-matrix coated-particle fuel originally developed for High- Temperature Gas-Cooled Reactors and (3) passive decay heat removal systems from sodium fast reactors. The base-line design is a pebble-bed FHR that delivers heat between 600 to 700°C with a 7 Li 2 BeF 4 (flibe) salt coolant to the power cycle or industrial users. The Executive Summary describes what was accomplished and summarizes major conclusions. The main report contains stand-alone sections in each major area of work. Highlights are summarized below. Tritium. The coolant salt produces tritium necessitating understanding and control of tritium. Experimental work included measuring hydrogen uptake on carbon, tritium uptake during irradiation of graphite in 700°C salt and the permeability of tritium through metals with and without coatings. An FHR systems model was developed to predict tritium behavior and enable design of tritium control systems. The leading candidate for tritium removal from the flibe salt is carbon bed outside the reactor core. Thermal hydraulics and Neutronics. A 10-meter high FHR integral effects test facility, using Dowtherm A®, has been built and used to simulate the integral response of a representative FHR to improve understanding of FHR thermal hydraulics and validate thermal hydraulics codes used for the FHR. Neutronic analysis included code-to-code benchmarking, multiphysics modeling, uncertainty analysis for nuclear data uncertainties and shielding analysis. Twisted-tube heat exchangers were examined that may provide significant cost reductions because of their improved heat-transfer performance with liquid salts. The impacts on safety and design caused by uncertainties in physical properties of the salt were assessed with recommendations on where added physical property measurements are needed. Work began on understanding radiative heat transfer that becomes important in salt systems at higher temperatures. Materials. Static corrosion tests were conducted on graphite and materials in 700°C salt -- both in the UW laboratory and in the MIT reactor. In addition to static corrosion testing, a circulating salt corrosion loop was built and is operating. Methods to measure salt properties including redox were developed. The presence of carbon increases corrosion. With good redox control, the evidence indicates stainless steel can be used as a material of construction. Benchmarking. An additional series of workshops where held to enable benchmarking and comparison of results between different investigators. Commercialization. The FHR delivers higher average-temperature (~650°C) heat to the power cycle or industry than other reactors. This enables power cycles with lower-cost heat storage for variable electricity to the grid while the reactor operates at base-load -- providing a major competitive advantage by maximizing revenue from electricity sales. In October, 2016, a new startup company named Kairos Power was formed, and opened its first office in Jack London Square, Oakland, California, in January 2017. Kairos Power exists largely due to the work that was accomplished by this IRP and the previous DOE-funded FHR IRP that performed research on FHR technology from 2012 to 2015. In September, 2018, as this IRP is concluding, Kairos Power was staffed at 60 full time employees, working to develop technology derived from this IRP. Many of these employees worked with the IRP before joining Kairos Power 1 (https://kairospower.com). Other students and researchers from this IRP have joined other startup companies, including the Terrapower Molten Chloride Fast Reactor and the Terrestrial Energy development efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Design of Critical Function Monitoring System of PGSFR

A PGSFR (Prototype Gen-IV Sodium-cooled Fast Reactor) is under development at Korea Atomic Energy Research Institute. A critical function monitoring system of the PGSFR is preliminarily studied. The functions of CFMS are to display critical plant variables related to the safety of the plant during normal and accident conditions and guide the operators corrective actions to keep the plant in a safe condition and mitigate the consequences of accidents. The minimal critical functions of the PGSFR are composed of reactivity control, reactor core cooling, reactor coolant system integrity, primary heat transfer system(PHTS) heat removal, sodium water reaction mitigation, radiation control and containment conditions. The variables and alarm legs of each critical function of the PGSFR are as follows; - Reactivity control: The variables of reactivity control function are power range neutron flux instrumentation, intermediate range neutron flux instrumentation, source range neutron flux instrumentation, and control rod bottom contacts. The alarm leg to display the reactivity controls consists of status of control drop malfunction, high post trip power and thermal reactivity addition. - Reactor core cooling: The variables are PHTS sodium level, hot pool temperature of PHTS, subassembly exit temperature, cold pool temperature of the PHTS, PHTS pump current, and PHTS pump breaker status. The alarm leg consists of high core delta temperature, low sodium level of the PHTS, high subassembly exit temperature, and low PHTS pump load. - Reactor coolant system integrity: The variables are PHTS sodium level, cover gas pressure, and safeguard vessel sodium level. The alarm leg is composed of low sodium level of PHTS, high cover gas pressure and high sodium level of the safety guard vessel. - PHTS heat removal: The variables are PHTS sodium level, hot pool temperature of PHTS, core exit temperature, cold pool temperature of the PHTS, flow rate of passive residual heat removal system, flow rate of active residual heat removal system, and temperatures of air heat exchanger temperature of residual heat removal systems. The alarm legs are composed of two legs of a 'passive residual heat removal system not cooling' and 'active residual heat removal system not cooling'. - Sodium water reaction mitigation: The variables are intermediate heat transfer system(IHTS) pressure, pressure and temperature and level of sodium dump tank, the status of rupture disk, hydrogen concentration in IHTS and direct variable of sodium-water-reaction measure. The alarm leg consists of high IHTS pressure, the status of sodium water reaction mitigation system and the indication of direct measure. - Radiation control: The variables are radiation of PHTS, radiation of IHTS, and radiation of containment purge. The alarm leg is composed of high radiation of PHTS and IHTS, and containment purge system. - Containment condition: The variables are containment pressure, containment isolation status, and sodium fire. The alarm leg consists of high containment pressure, status of containment isolation and status of sodium fire. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reuse of Treated Internal or External Wastewaters in the Cooling Systems of Coal-Based Thermoelectric Power Plants

This study evaluated the feasibility of using three impaired waters - secondary treated municipal wastewater, passively treated abandoned mine drainage (AMD), and effluent from ash sedimentation ponds at power plants - for use as makeup water in recirculating cooling water systems at thermoelectric power plants. The evaluation included assessment of water availability based on proximity and relevant regulations as well as feasibility of managing cooling water quality with traditional chemical management schemes. Options for chemical treatment to prevent corrosion, scaling, and biofouling were identified through review of current practices, and were tested at bench and pilot-scale. Secondary treated wastewater is the most widely available impaired water that can serve as a reliable source of cooling water makeup. There are no federal regulations specifically related to impaired water reuse but a number of states have introduced regulations with primary focus on water aerosol 'drift' emitted from cooling towers, which has the potential to contain elevated concentrations of chemicals and microorganisms and may pose health risk to the public. It was determined that corrosion, scaling, and biofouling can be controlled adequately in cooling systems using secondary treated municipal wastewater at 4-6 cycles of concentration. The high concentration of dissolved solids in treated AMD rendered difficulties in scaling inhibition and requires more comprehensive pretreatment and scaling controls. Addition of appropriate chemicals can adequately control corrosion, scaling and biological growth in ash transport water, which typically has the best water quality among the three waters evaluated in this study. The high TDS in the blowdown from pilot-scale testing units with both passively treated mine drainage and secondary treated municipal wastewater and the high sulfate concentration in the mine drainage blowdown water were identified as the main challenges for blowdown disposal. Membrane treatment (nanofiltration or reverse osmosis) can be employed to reduce TDS and sulfate concentrations to acceptable levels for reuse of the blowdown in the cooling systems as makeup water.

01 COAL, LIGNITE, AND PEAT↗

Real-time gas cooling of flowing liquid lithium limiter for the EAST

A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Thermal analysis for fuel handling system for sodium cooled reactor considering minor actinide-bearing metal fuel.

The Advanced Burner Reactor (ABR) is one of the components of the Global Nuclear Energy Partnership (GNEP) used to close the fuel cycle. ABR is a sodium-cooled fast reactor that is used to consume transuranic elements resulting from the reprocessing of light water reactor spent nuclear fuel. ABR-1000 [1000 MW(thermal)] is a fast reactor concept created at Argonne National Laboratory to be used as a reference concept for various future trade-offs. ABR-1000 meets the GNEP goals although it uses what is considered base sodium fast reactor technology for its systems and components. One of the considerations of any fast reactor plant concept is the ability to perform fuel-handling operations with new and spent fast reactor fuel. The transmutation fuel proposed as the ABR fuel has a very little experience base, and thus, this paper investigates a fuel-handling concept and potential issues of handling fast reactor fuel containing minor actinides. In this study, two thermal analyses supporting a conceptual design study on the ABR-1000 fuel-handling system were carried out. One analysis investigated passive dry spent fuel storage, and the other analysis investigated a fresh fuel shipping cask. Passive dry storage can be made suitable for the ABR-1000 spent fuel storage with sodium-bonded metal fuel. The thermal analysis shows that spent fast reactor fuel with a decay heat of 2 kW or less can be stored passively in a helium atmosphere. The 2-kW value seems to be a reasonable and practical level, and a combination of reasonably-sized in-sodium storage followed by passive dry storage could be a candidate for spent fuel storage for the next-generation sodium-cooled reactor with sodium-bonded metal fuel. Requirements for the shipping casks for minor actinide-bearing fuel with a high decay heat level are also discussed in this paper. The shipping cask for fresh sodium-cooled-reactor fuel should be a dry type to reduce the reaction between residual moisture on fresh fuel and the sodium coolant. The cladding temperature requirement is maintained below the creep temperature limit to avoid any damage before core installation. The thermal analysis shows that a helium gas-filled cask can accommodate ABR-1000 fresh minor actinide-bearing fuel with 700-W decay heat. The above analysis results revealed the overall requirement for minor actinide-bearing metal fuel handling. The information is thought to be helpful in the design of the ABR-1000 and future sodium-cooled-reactor fuel-handling system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of available data for estimating chloride-induced SCC crack growth rates for 304/316 stainless steel.

The majority of existing dry storage systems used for spent nuclear fuel (SNF) consist of a welded 304 stainless steel container placed within a passively-ventilated concrete or steel overpack. More recently fielded systems are constructed with dual certified 304/304L and in some cases, 316 or 316L. In service, atmospheric salts, a portion of which will be chloride bearing, will be deposited on the surface of these containers. Initially, the stainless steel canister surface temperatures will be high (exceeding the boiling point of water in many cases) due to decay heat from the SNF. As the SNF cools over time, the container surface will also cool, and deposited salts will deliquesce to form potentially corrosive chloride-rich brines. Because austenitic stainless steels are prone to chloride-induced stress corrosion cracking (CISCC), the concern has been raised that SCC may significantly impact long-term canister performance. While the susceptibility of austenitic stainless steels to CISCC in the general sense is well known, the behavior of SCC cracks (i.e., initiation and propagation behavior) under the aforementioned atmospheric conditions is poorly understood.

36 MATERIALS SCIENCE↗

Summary of available data for estimating chloride-induced SCC crack growth rates for 304/316 stainless steel

The majority of existing dry storage systems used for spent nuclear fuel (SNF) consist of a welded 304 stainless steel container placed within a passively-ventilated concrete or steel overpack. More recently fielded systems are constructed with dual certified 304/304L and in some cases, 316 or 316L. In service, atmospheric salts, a portion of which will be chloride bearing, will be deposited on the surface of these containers. Initially, the stainless steel canister surface temperatures will be high (exceeding the boiling point of water in many cases) due to decay heat from the SNF. As the SNF cools over time, the container surface will also cool, and deposited salts will deliquesce to form potentially corrosive chloride-rich brines. Because austenitic stainless steels are prone to chloride-induced stress corrosion cracking (CISCC), the concern has been raised that SCC may significantly impact long-term canister performance. While the susceptibility of austenitic stainless steels to CISCC in the general sense is well known, the behavior of SCC cracks (i.e., initiation and propagation behavior) under the aforementioned atmospheric conditions is poorly understood. A literature survey has been performed to identify SCC crack growth rate (CGR) studies conducted utilizing conditions that may be relevant to existing SNF interim storage canisters, the results of which are presented in this document. The data presented here have been restricted to those representing atmospheric corrosion of stainless steels due to deliquescence of marine salts, or marine salt components, on the metal surface. A suite of experimental studies representing both long-term field tests and accelerated laboratory tests has been identified. Potentially relevant data are summarized in Figures 1-1 (304 SS) and Figure 1-2 (316 SS). In the Figures, when a particular reference utilized a series of samples, the range is shown as a bar, and the average value shown with a symbol. A summary of the test methods, sample geometry, and environmental conditions for each study is given in Table 1-1. While the surveyed studies all explore SCC of austenitic stainless steels under atmospheric conditions, the methods through which each researcher approached the problem do differ, as illustrated in Table 1-1. The surveyed studies utilized a variety of metal treatments including as-fabricated, solution annealed, welded, and sensitized material. Furthermore, different surface treatments (polished vs ground) were also used. In addition, most of these studies were accomplished using techniques that are not generally accepted for high-fidelity crack growth rate measurements, and in cases where more traditional approaches were taken, these methodologies may not be applicable to the atmospheric conditions of interest here. The wide variety of methods and materials results in the observed large scatter in measured CGRs. Each of the data sets in Figures 1-1 and 1-2 is described in more detail in the following sections. A short summary of crack growth rates based on operational experience is also presented.

36 MATERIALS SCIENCE↗

The power of simplification: Operator interface with the AP1000{sup R} during design-basis and beyond design-basis events

The AP1000{sup R} plant is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and cost. The passive safety features are designed to function without safety-grade support systems such as component cooling water, service water, compressed air or HVAC. The AP1000 passive safety features achieve and maintain safe shutdown in case of a design-basis accident for 72 hours without need for operator action, meeting the expectations provided in the European Utility Requirements and the Utility Requirement Document for passive plants. Limited operator actions may be required to maintain safe conditions in the spent fuel pool (SFP) via passive means. This safety approach therefore minimizes the reliance on operator action for accident mitigation, and this paper examines the operator interaction with the Human-System Interface (HSI) as the severity of an accident increases from an anticipated transient to a design basis accident and finally, to a beyond-design-basis event. The AP1000 Control Room design provides an extremely effective environment for addressing the first 72 hours of design-basis events and transients, providing ease of information dissemination and minimal reliance upon operator actions. Symptom-based procedures including Emergency Operating Procedures (EOPs), Abnormal Operating Procedures (AOPs) and Alarm Response Procedures (ARPs) are used to mitigate design basis transients and accidents. Use of the Computerized Procedure System (CPS) aids the operators during mitigation of the event. The CPS provides cues and direction to the operators as the event progresses. If the event becomes progressively worse or lasts longer than 72 hours, and depending upon the nature of failures that may have occurred, minimal operator actions may be required outside of the control room in areas that have been designed to be accessible using components that have been designed to be reliable in these conditions. The primary goal of any such actions is to maintain or refill the passive inventory available to cool the core, containment and spent fuel pool in the safety-related and seismically qualified Passive Containment Cooling Water Storage Tank (PCCWST). The seismically-qualified, ground-mounted Passive Containment Cooling Ancillary Water Storage Tank (PCCAWST) is also available for this function as appropriate. The primary effect of these actions would be to increase the coping time for the AP1000 during design basis events, as well as events such as those described above, from 72 hours without operator intervention to 7 days with minimal operator actions. These Operator actions necessary to protect the health and safety of the public are addressed in the Post-72 Hour procedures, as well as some EOPs, AOPs, ARPs and the Severe Accident Management Guidelines (SAMGs). Should the event continue to become more severe and plant conditions degrade further with indications of inadequate core cooling, the SAMGs provide guidance for strategies to address these hypothetical severe accident conditions. The AP1000 SAMG diagnoses and actions are prioritized to first utilize the AP1000 features that are expected to retain a damaged core inside the reactor vessel. Only one strategy is undertaken at any time. This strategy will be followed and its effectiveness evaluated before other strategies are undertaken. This is a key feature of both the symptom-oriented AP1000 EOPs and the AP1000 SAMGs which maximizes the probability of retaining a damaged core inside the reactor vessel and containment while minimizing the chances for confusion and human errors during implementation. The AP1000 SAMGs are simple and straight-forward and have been developed with considerable input from human factors and plant operations experts. Most importantly, and different from severe accident management strategies for other plants, the AP1000 SAMGs do not require diagnosis of the location of the core (i.e., whether reactor vessel failure has occurred). This is a fundamental consequence of the AP1000 In-Vessel Retention approach, which allows severe accident management to be based on fundamental principles (e.g. provide coolant as close as possible to the core) that do not change during a specific event. This eliminates the need for one of the more difficult diagnostic requirements, since reactor vessel failure does not directly relate to any measurable plant parameter, and differs from other designs in that an engineered failure of the pressure vessel' (e.g. core catcher) is never required. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of the GHG Abatement Potentials in the U.S. Building Sector by 2050

Given the substantial contribution of the U.S. building sector to national carbon emissions, it is clear that to address properly the issue of climate change, one must first consider innovative approaches to understanding and encouraging the introduction of new, low-carbon technologies to both the commercial and residential building markets. This is the motivation behind the development of the Stochastic Lite Building Module (SLBM), a long range, open source model to forecast the impact of policy decisions and consumer behavior on the market penetration of both existing and emerging building technologies and the resulting carbon savings. The SLBM, developed at Lawrence Berkeley National Laboratory (LBNL), is part of the Stochastic Energy Deployment System (SEDS) project, a multi-laboratory effort undertaken in conjunction with the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), Argonne National Laboratory (ANL) and private companies. The primary purpose of SEDS is to track the performance of different U.S. Department of Energy (USDOE) Research and Development (R&D) activities on technology adoption, overall energy efficiency, and CO{sub 2} reductions throughout the whole of the U.S. economy. The tool is fundamentally an engineering-economic model with a number of characteristics to distinguish it from existing energy forecasting models. SEDS has been written explicitly to incorporate uncertainty in its inputs leading to uncertainty bounds on the subsequent forecasts. It considers also passive building systems and their interactions with other building service enduses, including the cost savings for heating, cooling, and lighting due to different building shell/window options. Such savings can be compared with investments costs in order to model real-world consumer behavior and forecast adoption rates. The core objective of this paper is to report on the new window and shell features of SLBM and to show the implications of various USDOE research funding scenarios on the adoption of these and other building energy technologies. The results demonstrate that passive technologies contain significant potential for carbon reductions - exceeding 1165 Mt cumulative savings between 2005 and 2050 (with 50% likelihood) and outperforming similar R&D funding programs for distributed photovoltaics and high efficiency solid-state lighting.

25 ENERGY STORAGE↗