Search NASA⌕ Search

SEARCH · Search NASA

Results for “Passive instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Charge collection in h -BN neutron detectors at elevated temperatures

Many of the neutron detector applications are in the environments with harsh conditions such as high temperatures. We report here the measurements of charge collection parameters of hexagonal boron nitride (h-BN) detectors at elevated temperatures, including the electron mobility-lifetime product (μτ) and surface recombination field (s/μ). It was found that μτ is increased, while s/μ is decreased as temperature increases. The temperature dependence of the surface recombination field (s/μ) revealed that electrons trapped in the surface states tend to thermally activate to the bulk region at higher temperatures with an activation energy of about 0.22 eV, leading to a reduction in the density of the charged surface states at elevated temperatures. Consequently, the charge collection efficiency is enhanced at elevated temperatures due to a reduced surface recombination field and increased electron mobility-lifetime product. The results suggested that h-BN neutron detectors are favorable for high temperature operation.

47 OTHER INSTRUMENTATION↗

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chapter 10 Supplement. Environmental Monitoring Technologies and Techniques for Detecting Interactions of Marine Animals with Marine Renewable Energy Devices

The Chapter 10 Supplementary Material provides information on instrument classes used for monitoring marine renewable energy devices such as passive acoustics, active acoustics, and video cameras. It also describes the applications and challenges of video cameras, and provides a technical glossary related to monitoring terminologies.

47 OTHER INSTRUMENTATION↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clearing a Path to Commercialization of Marine Renewable Energy Technologies Through Public–Private Collaboration

Governments are increasingly turning toward public–private partnerships to bring industry support to improving public assets or services. Here, we describe a unique public–private collaboration where a government entity has developed mechanisms to support public and private sector advancement and commercialization of monitoring technologies for marine renewable energy. These support mechanisms include access to a range of skilled personnel and test facilities that promote rapid innovation, prove reliability, and inspire creativity in technology development as innovations move from concept to practice. The ability to iteratively test hardware and software components, sensors, and systems can accelerate adoption of new methods and instrumentation designs. As a case study, we present the development of passive acoustic monitoring technologies customized for operation in energetic waves and currents. We discuss the value of testing different systems together, under the same conditions, as well as the progression through different test locations. The outcome is multiple, complementary monitoring technologies that are well suited to addressing an area of high environmental uncertainty and reducing barriers to responsible deployment of low-carbon energy conversion systems, creating solutions for the future.

16 TIDAL AND WAVE POWER↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

National Spherical Torus eXperiment - Upgrade NSTX-U: Structural Analysis of Passive Plates Support Brackets

The objective of this analysis is to estimate and assess the stresses in the passive plates caused by a limiting plasma disruption. The objective of this calculation is also to address observed damage to mounting hardware after completion of NSTX operation. These observations initiated diagnostic efforts during the Upgrade project to monitor the severity of the disruptions that were causing the damage, and planned instrumentation to trend the behavior of the mounting hardware. The Recovery Project mission for the passive plate hardware is to appropriately reinforce the passive plates with stainless steel ribs mounted on the back of the plate to reduce their flexure and stress and reinforcements of the “biscuit” components of the bracketry to transfer loads without damage to bolts, biscuits, and bracket plates and welds. Mid-plane disruptions and quenches were manageable with NSTX vintage hardware. The Vertical Displacement Event (VDE) disruptions position the plasma closer to the passive plates and are more severe than the centered plasma. Earlier work pointed to the P1-P5 VDE as limiting. This has been confirmed by A. Brooks work in support of the load generation effort in reference. During vertical displacement large counter currents are generated in the plate as the plasma approaches it. - as would be expected from passive plates. When the plasma disrupts the currents in the plates are reversed, which also reverses the loading on the plates. This report documents the methodology and results of transient structural analysis on the plasma, passive plates support brackets. The loads induced by eddy and halo currents have been considered, and were generated using a separate electromagnetic analysis (NSTXU_1_11_2_1_CALC_051). The structural model also incorporates the effects from preload. Calculation was performed with the assumption that existing biscuits are not participating in the load bearing except the biscuits connected to jumper bolts, which are fully engaged. Results show that with the planned reinforcements, Passive plates and mounting structures satisfy static and fatigue criteria in all areas except welds, where separate analysis was performed. Both symmetric and asymmetric (with locating block) designs were analyzed, and although stresses were higher without locating block they still satisfy NSTX design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Intrinsic Fiber Optic Temperature Sensors by In-core and Furnace Testing

Increased research and development in nuclear technology has raised the demand for novel sensors and instrumentation to meet data objectives, and survive in different conditions and environments, beyond conventional light water reactor (LWR) environments. Expediting the deployment of advanced nuclear technologies by developing, demonstrating, and qualifying advanced reactor fuel forms necessitates a deeper understanding of how irradiation affects fuels and materials' performance. To achieve a more comprehensive understanding of fuels and materials performance, researchers require more specialized experiments and measurements. The demand for innovative sensors to support nuclear fuel development arises from the complexity of materials' behavior under irradiation and the challenges of deploying instrumentation in Material Test Reactors (MTRs) for irradiation tests. Additionally, measurements of material properties require integrated measurement systems to characterize thermal properties, mechanical properties, chemistry, and microstructure [1]. Among the potential measurement techniques, optical fiber-based sensors have been identified as potential sensors to measure different physical phenomena such as temperature, strain, pressure, and fluid level. Optical fiber sensors have the capability to provide multi-sensing and multiplexing instrumentation, allowing the measurement of different physical parameters within a single sensor configuration, and transmitting data collected at multiple locations through a single fiber. They offer immunity to electromagnetic interference, electrical passivity, compatibility with various sensing methodologies, and cost-effectiveness. Beyond their widespread use in telecommunications, silica fiber-based instruments are utilized in industrial applications, even at temperatures reaching 300?400°C, such as distributed temperature sensing in oil and gas recovery. The Department of Energy (DOE) is interested in using fiber optics to support fuel cycle development [2]. Fiber optics are an excellent candidate for harsh environment sensing, including sensing at very high temperatures (1900oC for sapphire optical fibers). Distributed fiber optic sensing has been deployed in other harsh environments like coal gasification plants [3]. Distributed strain sensing, which operates similarly to distributed temperature sensing, has been deployed to monitor underground mines and fibers have been imbedded in soil to monitor sink-hole development [4][5]. The application of fiber optic sensors to advanced reactor development is a promising area of research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRACER-Coastal Urban Boundary-Layer Interactions with Convection (TRACER-CUBIC) Field Campaign Report

To better understand the complicated web of processes governing convective cloud life cycle and aerosol-convection interactions, the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility supported deployment of a variety of advanced atmospheric measurement systems to the greater Houston, Texas, area from 1 October 2021 to 30 September 2022 as part of the Tracking Aerosol Convection Interactions Experiment (TRACER). Houston was selected as a study area because isolated convection and a variety of aerosol conditions are common in this region. This one-year ARM Mobile Facility (AMF) deployment featured a four-month intensive operational period (IOP) during summer 2022 (1 June–30 September). The ARM instrumentation was deployed at three sites along an east-west transect from La Porte, Texas to an ancillary site in a less-polluted rural region southwest of downtown Houston (Figure 1). At the La Porte Site, which is located near the Houston ship channel in an area that experiences significant pollution, the first ARM Mobile Facility (AMF1) was deployed. During the IOP, the ARM tethered balloon system (TBS) operated at the ancillary site. The second-generation C-Band Scanning ARM Precipitation Radar (CSAPR) operated near Pearland, Texas, roughly halfway between the Laporte and ancillary sites. As part of the TRACER- Coastal Urban Boundary-Layer Interactions with Convection (CUBIC) project, three boundary-layer profiling systems) were deployed along a north-south transect spanning from the University of Houston Coastal Center to the Aldine site north of downtown Houston (also blue dot in Figure 1) during the TRACER IOP. These systems included the National Oceanic and Atmospheric Administration (NOAA) National Severe Storms Laboratory CLAMPS2 (C2), which was deployed at the UHCC, the University of Wisconsin SPARC, which was deployed at the ARM CSAPR site near Pearland (orange diamond in middle of map in Figure 1), and the University of Oklahoma CLAMPS1 (C1), which was deployed at Aldine. These three systems have been successfully operated in various field campaigns, providing data sets that collectively offer new insights into atmospheric-boundary-layer (ABL) processes, sea-breeze (SB) circulations, and convection initiation (CI). For the TRACER IOP window, these systems ran continuously between 1 June and 26 September, 2022. Due to commitments to NOAA projects, the Doppler lidar at the UHCC site was not available until 24 June 2022. The CLAMPS and SPARC profiling systems are self-contained platforms that have benefited from several years of development and deployment. Instruments and data processing were maintained remotely, which made the 4-month deployment for the TRACER-CUBIC IOP period possible. The same basic instrument configuration comprises each system: a scanning Doppler wind lidar for flow characterization and passive profiler(s) for characterizing planetary-boundary-layer (PBL) thermodynamic properties. Each platform includes a Halo Streamline Doppler wind lidar, an Atmospheric Emitted Radiance Interferometer (AERI), and a surface meteorology station. CLAMPS1 and CLAMPS2 each also include a microwave radiometer (MWR, Figure 1d). The TRACER-CUBIC hypotheses included (i) Interactions of SB and urban circulations and how they affect the PBL structure in the Houston environment, causing spatially (horizontally and vertically) and temporally highly variable flow patterns, (ii) heat, moisture, and aerosol transport and mixing depend on these flow dynamics, and (iii) an improved understanding of the flow patterns and PBL structure are critical for investigating the processes leading to CI. To test these hypotheses, the project aimed at (i) characterizing SB circulations and their impacts on the diurnal evolution of the structure of the ABL, (ii) studying the evolution of Houston’s complex urban boundary layer, and (iii) identifying effects of urban-induced circulations on pre-convective environments. TRACER-CUBIC observations generally provide good coverage during the summer IOP. Initial screening of the data indicates a good number of cases with bay-breeze (BB) and/or SB signatures, local CI, and interesting boundary-layer features such as strong nocturnal low-level jets (LLJs, Table 1). The numbers listed in rows 3-5 in this table will be further updated as part of ongoing in-depth analyses and systematic identification of local circulations and CI events. More detailed information about the data availability and quality for each instrument is provided in the “readme” files that were submitted to the ARM Data Center along with each archived data sets. These “readme” files also provide instrument descriptions, information about the data collection and processing procedures, data formats, and any additional information relevant for further data analysis.

54 ENVIRONMENTAL SCIENCES↗

Evaluations of Silicon Carbide Temperature Monitors

The effect of irradiation on materials properties is an important field of study for materials usage in both fission and fusion systems for energy production. Neutron flux and energy spectrums are well understood; however, the irradiation temperature can be more difficult to determine. Since the early 1960s, Silicon Carbide (SiC) has been used as a passive post-irradiation temperature monitor because the irradiation defects anneal out above the irradiation temperature. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process. There are many properties that may be measured including electrical resistivity, bulk density, dimensions, thermal diffusivity, or lattice spacing. Electrical resistivity is accepted as a robust measurement technique; however, such method is time-consuming since the steps involved must be performed in a serial manner. The use of thermal expansion from continuous dilatometry is an automated process requiring minimal setup time. As part of a Nuclear Science User Facilities (NSUF) project, low dose silicon carbide monitors were irradiated in the BR2 material test reactor at SCK, Belgium, and were then evaluated at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation processes available at HTTL and the performance of the low dose silicon carbide temperature monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of Wireless Sensor Networks and Battery-free RFID for Advanced Reactors

To address an important need for Nuclear Power Plants (NPPs) to significantly reduce the amount of the required cables for sensor data communications, this Phase I SBIR effort successfully developed and demonstrated a novel low-cost proof-of-concept prototype of a secure wireless sensor network backbone communications system. This system combines commercially available low power, low cost XBEE wireless communications network and passive (battery-free) Radio Frequency Identification (RFID) systems to report individual sensor data and their location through the containment wall for rapid response to anomalies in nuclear facilities. This WIreless Sensing and Locating (WISLO) system network architecture allows non-intrusive wireless collection of sensor data with the sensor’s accurate location information from inside of the instrumentation or containment area with minimal need for power sources. The multi-node sensor data in the containment area is wirelessly transmitted to outside through the metal reinforced concrete walls without the need for any batteries. The WISLO system could be readily used in current reactor fleet and future advanced reactors, as well as in small modular reactors (SMR). The WISLO system is the first dual frequency battery-free trough the wall communications backbone system developed specifically for use in nuclear power plants. It not only can modernize the sensor monitoring practices in the existing reactor fleet, but also offers a secure, low-cost solution to advanced reactors and SMRs by removing cables and issues related to them such as cable integrity, reporting delays, and installation and maintenance costs. The intent is to improve process safety, reliability, efficiency, and cost effectiveness to the monitoring and maintenance process in current and future plants. As we address the next productization and manufacturing capabilities in the next phase, this system will serve the needs of many commercial and government applications in remote monitoring of sensor data that demand battery-free transmission of sensor data such as Internet-of-Things (IOT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗