Plasma electron acceleration driven by a long-wave-infrared laser

Laser-driven plasma accelerators provide tabletop sources of relativistic electron bunches and femtosecond x-ray pulses, but usually require petawatt-class solid-state-laser pulses of wavelength λ L ~ 1 μm. Longer-λ L lasers can potentially accelerate higher-quality bunches, since they require less power to drive larger wakes in less dense plasma. Here, we report on a self-injecting plasma accelerator driven by a long-wave-infrared laser: a chirped-pulse-amplified CO 2 laser (λ L ≈ 10 μm). Through optical scattering experiments, we observed wakes that 4-ps CO 2 pulses with < 1/2 terawatt (TW) peak power drove in hydrogen plasma of electron density down to 4 × 10 17 cm –3 (1/100 atmospheric density) via a self-modulation (SM) instability. Shorter, more powerful CO 2 pulses drove wakes in plasma down to 3 × 10 16 cm –3 that captured and accelerated plasma electrons to relativistic energy. Collimated quasi-monoenergetic features in the electron output marked the onset of a transition from SM to bubble-regime acceleration, portending future higher-quality accelerators driven by yet shorter, more powerful pulses.

43 PARTICLE ACCELERATORS↗

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States↗

Design of inertial fusion implosions reaching the burning plasma regime

Abstract In a burning plasma state 1–7 , alpha particles from deuterium–tritium fusion reactions redeposit their energy and are the dominant source of heating. This state has recently been achieved at the US National Ignition Facility 8 using indirect-drive inertial-confinement fusion. Our experiments use a laser-generated radiation-filled cavity (a hohlraum) to spherically implode capsules containing deuterium and tritium fuel in a central hot spot where the fusion reactions occur. We have developed more efficient hohlraums to implode larger fusion targets compared with previous experiments 9,10 . This delivered more energy to the hot spot, whereas other parameters were optimized to maintain the high pressures required for inertial-confinement fusion. We also report improvements in implosion symmetry control by moving energy between the laser beams 11–16 and designing advanced hohlraum geometry 17 that allows for these larger implosions to be driven at the present laser energy and power capability of the National Ignition Facility. These design changes resulted in fusion powers of 1.5 petawatts, greater than the input power of the laser, and 170 kJ of fusion energy 18,19 . Radiation hydrodynamics simulations 20,21 show energy deposition by alpha particles as the dominant term in the hot-spot energy balance, indicative of a burning plasma state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The X-Ray Emission Effectiveness of Plasma Mirrors: Reexamining Power-Law Scaling for Relativistic High-Order Harmonic Generation

Ultrashort pulsed lasers provide uniquely detailed access to the ultrafast dynamics of physical, chemical, and biological systems, but only a handful of wavelengths are directly produced by solid-state lasers, necessitating efficient high-power frequency conversion. Relativistic plasma mirrors generate broadband power-law spectra, that may span the gap between petawatt-class infrared laser facilities and x-ray free-electron lasers; despite substantial theoretical work the ultimate efficiency of this relativistic high-order-harmonic generation remains unclear. We show that the coherent radiation emitted by plasma mirrors follows a power-law distribution of energy over frequency with an exponent that, even in the ultrarelativistic limit, strongly depends on the ratio of laser intensity to plasma density and exceeds the frequently quoted value of -8/3 over a wide range of parameters. The coherent synchrotron emission model, when adequately corrected for the finite width of emitting electron bunches, is not just valid for p-polarized light and thin foil targets, but generally describes relativistic harmonic generation, including at normal incidence and with finite-gradient plasmas. Our numerical results support the ω-4/3 scaling of the synchrotron emission model as a limiting efficiency of the process under most conditions. The highest frequencies that can be generated with this scaling are usually restricted by the width of the emitting electron bunch rather than the Lorentz factor of the fastest electrons. The theoretical scaling relations developed here suggest, for example, that with a 20-PW 800-nm driving laser, 1 TW/harmonic can be produced for 1-keV photons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New criteria for efficient Raman and Brillouin amplification of laser beams in plasma

Raman or Brillouin amplification of a laser beam in plasma has long been seen as a way to reach multi-PW powers in compact laser systems. However, no significant plasma-based Raman amplification of a laser pulse beyond 0.1 TW has been achieved in nearly 20 years, and only one report of Brillouin amplification beyond 1 TW. In this paper, we reveal novel non-linear criteria for the initial seed pulse that will finally open the door to efficient Raman and Brillouin amplification to petawatt powers and Joule-level energies. We show that the triple product of the coupling constant \(\Gamma \) , seed pulse duration \(\tau \) and seed pulse amplitude a for the Raman seed pulse (or \(a^{2/3}\) for Brillouin) must exceed a specific minimum threshold for efficient amplification. We also analyze the plasma-based Raman and Brillouin amplification experiments to date, and show that the seed pulses used in nearly all experiments are well below our new threshold, which explains the poor efficiency obtained in them. Finally, we analyze a recent Brillouin amplification experiment that used increased seed pulse power to obtain Joule-level amplification, and find excellent agreement with our theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new platform for ultra-high dose rate radiobiological research using the BELLA PW laser proton beamline

Abstract Radiotherapy is the current standard of care for more than 50% of all cancer patients. Improvements in radiotherapy (RT) technology have increased tumor targeting and normal tissue sparing. Radiations at ultra-high dose rates required for FLASH-RT effects have sparked interest in potentially providing additional differential therapeutic benefits. We present a new experimental platform that is the first one to deliver petawatt laser-driven proton pulses of 2 MeV energy at 0.2 Hz repetition rate by means of a compact, tunable active plasma lens beamline to biological samples. Cell monolayers grown over a 10 mm diameter field were exposed to clinically relevant proton doses ranging from 7 to 35 Gy at ultra-high instantaneous dose rates of 10 7 Gy/s. Dose-dependent cell survival measurements of human normal and tumor cells exposed to LD protons showed significantly higher cell survival of normal-cells compared to tumor-cells for total doses of 7 Gy and higher, which was not observed to the same extent for X-ray reference irradiations at clinical dose rates. These findings provide preliminary evidence that compact LD proton sources enable a new and promising platform for investigating the physical, chemical and biological mechanisms underlying the FLASH effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A laser parameter study on enhancing proton generation from microtube foil targets

Abstract The interaction of an intense laser with a solid foil target can drive $$\sim$$ ∼ TV/m electric fields, accelerating ions to MeV energies. In this study, we experimentally observe that structured targets can dramatically enhance proton acceleration in the target normal sheath acceleration regime. At the Texas Petawatt Laser facility, we compared proton acceleration from a $$1\, {\upmu }\hbox {m}$$ 1 μ m flat Ag foil, to a fixed microtube structure 3D printed on the front side of the same foil type. A pulse length (140–450 fs) and intensity ((4–10) $$\times 10^{20}$$ × 10 20 W/cm $$^2$$ 2 ) study found an optimum laser configuration (140 fs, 4 $$\times 10^{20}$$ × 10 20 W/cm $$^2$$ 2 ), in which microtube targets increase the proton cutoff energy by 50% and the yield of highly energetic protons ( $$>10$$ > 10 MeV) by a factor of 8 $$\times$$ × . When the laser intensity reaches $$10^{21}$$ 10 21 W/cm $$^2$$ 2 , the prepulse shutters the microtubes with an overcritical plasma, damping their performance. 2D particle-in-cell simulations are performed, with and without the preplasma profile imported, to better understand the coupling of laser energy to the microtube targets. The simulations are in qualitative agreement with the experimental results, and show that the prepulse is necessary to account for when the laser intensity is sufficiently high.

43 PARTICLE ACCELERATORS↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy ion beams generated with high efficiency using laser-driven 3D microstructures

Laser-driven ion acceleration in plasma is being proposed as a source of ion beams with a high peak current that can be useful in many fields of science and medicine. Using this method, high proton energies have been achieved by increasing the laser power and by using ultrathin (≤ 200 nm) foils. However, this approach is limited by survivability of the nanotargets to laser prepulses and by difficulty in controlling the plasma acceleration properties. Here, we introduce a new target platform using two-photon polymerization, 3D laser-printed “clone” microstructures with average densities lower than solid that are relatively insensitive to the laser prepulse. Two types of microstructured targets consisting of either a multilayered log-pile or a stochastic arrangement of one micron diameter wires are used. Both demonstrate a higher energy and higher yield proton acceleration compared to thin solid-density foil targets by the robust target normal sheath acceleration (TNSA) mechanism. We find that when such 10–20 μm thick structures are irradiated with a petawatt laser, protons with energies up to 110 MeV and a laser-to-proton conversion efficiency of ~ 10% are obtained. Our work suggests that such microstructures optimized for 60–200 MeV compact proton accelerators are promising for future radiotherapy and other applications.

Physics - Plasma physics↗

Heavy ion induced e + e − pair production: Theoretical and preliminary experimental efforts

The production of real e + e − pairs is an important quantum electrodynamics phenomenon, that could have significant implications on low energy heavy ion dynamics. Here, we employ an established Schwingerinspired theory to study this effect in nuclear disintegrations. We extend the current framework with a Monte Carlo approach to include non-perturbative contributions. Simultaneously, we supplement our study with a preliminary experimental procedure, via the use of the Global Spectrometer for Positron and Electron Characterization developed at the Texas Petawatt Laser facility of the University of Texas at Austin. Theory and experiment agree within one order of magnitude, which signals promise for further investigations.

Depastas, T.↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

Laser-heated capillary discharge waveguides as tunable structures for laser-plasma acceleration

Laser-heated capillary discharge waveguides are novel, low plasma density guiding structures able to guide intense laser pulses over many diffraction lengths and have recently enabled the acceleration of electrons to 7.8 GeV by using a laser-plasma accelerator (LPA). These devices represent an improvement over conventional capillary discharge waveguides, as the channel matched spot size and plasma density can be tuned independently of the capillary radius. This has allowed the guiding of petawatt-scale pulses focused to small spot sizes within large diameter capillaries, preventing laser damage of the capillary structure. High performance channel-guided LPAs require control of matched spot size and density, which experiments and simulations reported here show can be tuned over a wide range via initial discharge and laser parameters. In this paper, measurements of the matched spot size and plasma density in laser-heated capillary discharges are presented, which are found to be in excellent agreement with simulations performed using the MHD code MARPLE. Strategies for optimizing accelerator performance are identified based on these results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of radiochromic film stacks to diagnose high-flux laser-accelerated proton beams

Here, we extend flatbed scanner calibrations of GafChromic EBT3, MD-V3, and HD-V2 radiochromic films using high-precision x-ray irradiation and monoenergetic proton bombardment. By computing a visibility parameter based on fractional errors, optimal dose ranges and transitions between film types are identified. The visibility analysis is used to design an ideal radiochromic film stack for the proton energy spectrum expected from the interaction of a petawatt laser with a cryogenic hydrogen jet target.

Curry, C. B. (ORCID:000000018756181X)↗

A scintillator attenuation spectrometer for intense gamma-rays

A new type of compact high-resolution high-sensitivity gamma-ray spectrometer for short-pulse intense gamma-rays (250 keV to 50 MeV) has been developed by combining the principles of scintillators and attenuation spectrometers. The first prototype of this scintillator attenuation spectrometer (SAS) was tested successfully in Trident laser experiments at LANL. Later versions have been used extensively in the Texas Petawatt laser experiments in Austin, TX, and more recently in OMEGA-EP laser experiments at LLE, Rochester, NY. The SAS is particularly useful for high-repetition-rate laser applications. Furthermore, we give a concise description of the design principles, capabilities, and sample preliminary results of the SAS.

47 OTHER INSTRUMENTATION↗

Generation of collimated vortex gamma-rays from intense Poincaré beam–plasma interaction

We report on numerical calculations in which a multi-petawatt γ-ray beam is generated using a novel configuration based on fully structured light irradiating an overdense plasma waveguide. We analyze how the relativistic laser pulse efficiently confines and accelerates plasma electrons to GeV-scale energies and drives a quasi-static field that induces magneto-bremsstrahlung radiation. Multiphoton Compton scattering of electrons in the intense part of the laser also occurs although the radiated energy-density is comparatively lower. The emitted γ-rays carry orbital angular momentum, are highly collimated, and account for upwards of 15% of the incident field energy in one particular case. A comparison of the laser-to-particle angular momentum and energy transfer efficiencies is made between the cases of irradiation by a circularly polarized Laguerre–Gauss mode and one type of full Poincaré beam, and it is found that the latter yields an order-of-magnitude enhancement. In conclusion, the essential characteristics of the interaction are validated with three-dimensional particle-in-cell simulations that include quantum electrodynamical effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The acceleration of a high-charge electron bunch to 10 GeV in a 10-cm nanoparticle-assisted wakefield accelerator

An intense laser pulse focused onto a plasma can excite nonlinear plasma waves. Under appropriate conditions, electrons from the background plasma are trapped in the plasma wave and accelerated to ultra-relativistic velocities. This scheme is called a laser wakefield accelerator. In this work, we present results from a laser wakefield acceleration experiment using a petawatt-class laser to excite the wakefields as well as nanoparticles to assist the injection of electrons into the accelerating phase of the wakefields. We find that a 10-cm-long, nanoparticle-assisted laser wakefield accelerator can generate 340 pC, 10 ± 1.86 GeV electron bunches with a 3.4 GeV rms convolved energy spread and a 0.9 mrad rms divergence. It can also produce bunches with lower energies in the 4–6 GeV range.

36 MATERIALS SCIENCE↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.