Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase 1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

PSTN-053: Survey Cadence Optimization Committee's Phase 1 Recommendations

This document is authored by the Survey Cadence Optimization Committee (SCOC), guided by the community input, and it will serve as a roadmap for the concluding round of survey cadence simulations. These simulations, to be delivered during early calendar year 2022, will inform the phase 2 survey strategy recommendation which will define the baseline strategy for starting the Rubin Observatory's Legacy Survey of Space and Time (LSST). The phase 2 SCOC recommendation will be delivered to the Rubin Observatory Operations Director before the end of calendar year 2022.

79 ASTRONOMY AND ASTROPHYSICS↗

A Phase 1 Dose-Escalation Trial of Radiation Therapy and Concurrent Cisplatin for Stage II and III Triple-Negative Breast Cancer

Patients with triple-negative breast cancer (TNBC) experience higher local-regional recurrence rates than those with luminal or HER2-positive tumors. This prospective, phase 1B trial was designed to assess the safety and to establish the maximum tolerated dose (MTD) of cisplatin with radiation therapy for women with early-stage TNBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Williston Basin Core-CM Initiative (Phase 1 Interim Report)

The Energy & Environmental Research Center (EERC) is leading the Williston Basin Coal Ore, Rare Earth Elements, and Critical Minerals (CORE-CM) Initiative, an initiative to drive the expansion and transformation of coal and coal-based resource usage within the Williston Basin to produce rare-earth elements (REEs), critical minerals (CMs), and nonfuel carbon-based products (NFCBPs). This project is the first phase in a long-term program and will set the stage for future work by assessing resource, market, technology, and infrastructure knowledge; identifying knowledge gaps; developing a series of plans to be carried out in future work; and initiating stakeholder engagement. Composed of several tasks, the project seeks to identify, characterize, and assess several necessary aspects vital to make this future work a reality.

01 COAL, LIGNITE, AND PEAT↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

Glovebox Fires Phase 1: Simulations of Open Burner Experiments

Understanding the duration of a fire required to breach a glovebox via glove ports and/or windows within a facility is important in developing mitigation strategies for safety. To facilitate this understanding, both simulation and experiments are utilized. The approach is to first validate the Computation Fluid Dynamics (CFD) code, Fire Dynamics Simulator (FDS), with experimental data collected by New Mexico Tech (NMT) and then perform simulations of full-scale rooms containing gloveboxes to assess numerous scenarios which would otherwise be cost-prohibitive experimentally. This report provides comparison to first-phase experiments involving a fire without a glovebox. A subsequent report will provide comparison to experiments involving a glovebox. The results indicate good agreement with FDS tending to over predict the pre-mixed and diffusion-mode tests by 6% and 10%, respectively.

42 ENGINEERING↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Macro-micro multiscale modeling to assist the design of HPDC Al castings microstructure and alloys for EV super-large body structures (Phase 1)

Implementation of High Pressure Die Casting (HPDC) Aluminum (Al) body structures for high volume electrified vehicles (EV) to improve electric efficiency remains a key strategy within many original equipment manufacturer (OEM)s. In addition to high strength for safety requirements, superior Self-Piercing Riveting (SPR) performance is demanded for HPDC Al alloys to be compatible with high volume SPR joining. In this work, it is proposed to extend and validate an existing Contractor finite element multiscale macro-micro modeling approach to quantify the influence of the microstructure of HPDC alloys on the fracture strain/displacement under 3-point bend and clinch testing. The success of this work will allow to replace solution treatment stage with low energy consumption heat treatment (HT) processes, or to design new non heat treatable (NHT) HPDC Al alloys to eliminate HT requirements. Ultimately, this project will facilitate the application of HPDC Al alloys for super-large vehicle structures to significantly reduce vehicle weight, and thus improving energy efficiency. The purpose of this project is to extend and validate an existing finite element code, which is based on the Contractor developed macro-micro multi-scale modeling approach, to numerically simulate the three-point bending and clinch test and study the influences of material microstructural characteristics and phase properties on the rivetability. The macro-micro modeling approach begins with a sample scale model and identify the location, which is mostly prone to failure, the deformation history of the boundaries of that location calculated will be used to drive a microstructure-based sub-models where the material microstructure and microscale properties are considered. Using this approach, the wrap-bending failure for two Al alloys are correctly predicted for the first time. This will start with phase I effort of building a framework of macro-micro three point bending test and clinch test of Al10SiMgMn HPDC alloy in the as-cast and T7 heat treated conditions. Those results will then be validated with experimental test results. The phase II effort will involve the utilization of the knowledge learned in phase I to establish the quantitative correlation between the microstructure characteristics and the riveting performance, which will be further used to guide the optimization of HPDC Al alloy microstructure using heat treatment process to achieve sufficient rivetability to join large thin-wall HPDC alloys.

36 MATERIALS SCIENCE↗

A Phase 1 Dose Escalation Study of Neoadjuvant SBRT Plus Elective Nodal Radiation with Concurrent Capecitabine for Resectable Pancreatic Cancer

The role of neoadjuvant radiation for resectable pancreatic adenocarcinoma is controversial. We performed a prospective dose-escalation study of neoadjuvant stereotactic body radiation therapy (SBRT) with concurrent capecitabine and elective nodal irradiation (ENI) followed by surgical resection to explore the toxicity and feasibility of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Single-Arm Phase 1 and 2 Study: Ipilimumab and Nivolumab With Thoracic Radiation Therapy After Platinum Chemotherapy in Extensive-Stage Small Cell Lung Cancer

Consolidative thoracic radiation therapy (TRT) has been shown to improve outcomes for patients with extensive stage small cell lung cancer. We hypothesized that the addition of ipilimumab (IPI) and nivolumab (NIVO) after TRT would improve outcomes for patients with extensive stage small cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity of L19-Interleukin 2 Combined with Stereotactic Body Radiation Therapy: A Phase 1 Study

The immunocytokine L19-IL2 delivers interleukin-2 to the tumor by exploiting the selective L19-dependent binding of extradomain B of fibronectin on tumor blood vessels. In preclinical models, L19-IL2 has been shown to enhance the local and abscopal effects of radiation therapy. The clinical safety of L19-IL2 monotherapy has been established previously. In this study, the safety and tolerability of L19-IL2 after stereotactic body radiation therapy (SBRT) was assessed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and antiviral activity of triple combination broadly neutralizing monoclonal antibody therapy against HIV-1: a phase 1 clinical trial

HIV-1 therapy with single or dual broadly neutralizing antibodies (bNAbs) has shown viral escape, indicating that at least a triple bNAb therapy may be needed for robust suppression of viremia. We performed a two-part study consisting of a single-center, randomized, double-blind, dose-escalation, placebo-controlled first-in-human trial of the HIV-1 V2-glycan-specific antibody PGDM1400 alone or in combination with the V3-glycan-specific antibody PGT121 in 24 adults without HIV in part 1, as well as a multi-center, open-label trial of the combination of PGDM1400, PGT121 and the CD4-binding-site antibody VRC07-523LS in five viremic adults living with HIV not on antiretroviral therapy (ART) in part 2. The primary endpoints were safety, tolerability and pharmacokinetics for both parts and antiviral activity among viremic adults living with HIV and not on ART for part 2 of the study. The secondary endpoints were changes in CD4 + T cell counts and development of HIV-1 sequence variations associated with PGDM1400, PGT121 and VRC07-523LS resistance in part 2. Intravenously administered PGDM1400 was safe and well-tolerated at doses up to 30 mg kg -1 and when given in combination with PGT121 and VRC07-523LS. A single intravenous infusion of 20 mg kg -1 of each of the three antibodies reduced plasma HIV RNA levels in viremic individuals by a maximum mean of 2.04 log10 copies per ml; however, viral rebound occurred in all participants within a median of 20 days after nadir. Rebound viruses demonstrated partial to complete resistance to PGDM1400 and PGT121 in vitro, whereas susceptibility to VRC07-523LS was preserved. Viral rebound occurred despite mean VRC07-523LS serum concentrations of 93 µg ml -1 . The trial met the pre-specified endpoints. Our data suggest that future bNAb combinations likely need to achieve broad antiviral activity, while also maintaining high serum concentrations, to mediate viral control.

60 APPLIED LIFE SCIENCES↗