Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

To Produce Nutrients for Plant Growth

On July 1, 1979 a new research program entitled "Development of a Prototype Experiment for Treating CELSS and PCELSS Wastes to Produce Nutrients for Plant Growth" was undertaken by the Massachusetts Institute of Technology and the Georgia Institute of Technology under grant from the National Aeronautics and Space Administration's Ames Research Center. The program was designed to be completed over a five-year period, with the work divided into two phases. Phase I covers approximately two years and involves the development of necessary facilities, chemical methodologies and models to allow meaningful experiments during Phase II, which will involve interfacing waste oxidation with plant growth. Homogeneous samples of freeze-dried human feces and urine have been prepared to assure comparability of results among various CELSS waste treatment research groups. A model of food processing wastes within a PCELSS was developed, and an initial batch of waste was prepared. An automated gas chromatographic system to analyze oxidizer effluents was designed and is operational. A state-of-the-art quantitative elemental analysis capability, built around inductively coupled plasma emission spectroscopy and atomic absorption spectroscopy using electrothermal atomization, has been demonstrated. A continuous flow wet oxidation system was constructed and is now operational.

Michael Modell↗

Tunable Quantum-Well Submillimeter-Wave Oscillators

Tunable submillimeter-wave generator is layered (AI/Ga)As device. Frequencies adjusted via applied voltages. New device concept offers potential to make relatively compact, efficient local oscillators for heterodyne mixers in submillimeter radar and imaging systems, nondestructive testing, diagnosis of plasmas, airborne spectroscopy of atmosphere, detection of weapons and other contraband, and communications.

Maserjian, Joseph↗

Preparation And Analysis Of Specimens Of Ablative Materials

Procedure for chemical analysis of specimens of silicone-based ablative thermal-insulation materials SLA-561 and MA25 involves acid digestion of specimens to prepare them for analysis by inductively-coupled-plasma/atomic-emission spectroscopy (ICP/AES). In comparison with atomic-absorption spectroscopy (AAS), ICP/AES is faster and more accurate than AAS. Results of analyses stored in data base, used to trace variations in concentrations of chemical elements in materials during long-term storage, and used in timely manner in investigations of failures. Acid-digestion portion of procedure applied to other thermal-insulation materials containing room-temperature-vulcanizing silicones and enables instrumental analysis of these materials.

Solomon, William C.↗

Microcalorimeters for High Resolution X-Ray Spectroscopy of Laboratory and Astrophysical Plasmas

The proposal has three major objectives. The first focuses on advanced neutron-transmutation-doped (NTD)-based microcalorimeter development. Our goal is to develop an array of microcalorimeters with sub- 5 eV energy resolution that can operate with pile-up-free throughput of at least 100 Hz per pixel. The second objective is to establish our microcalorimeter as an essential x-ray diagnostic for laboratory astrophysics studies. We propose to develop a dedicated microcalorimeter spectrometer for the EBIT (electron beam ion trap). This instrument will incorporate the latest detector and cryogenic technology that we have available. The third objective is to investigate innovative ideas related to possible flight opportunities. These include compact, long lived cryo-systems, ultra-low temperature cold stages, low mass and low power electronics, and novel assemblies of thin windows with high x-ray transmission.

Silver, E.↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.

plasma↗

Spectroscopy and atomic physics of highly ionized Cr, Fe, and Ni for tokamak plasmas

The paper considers the spectroscopy and atomic physics for some highly ionized Cr, Fe, and Ni ions produced in tokamak plasmas. Forbidden and intersystem wavelengths for Cr and Ni ions are extrapolated and interpolated using the known wavelengths for Fe lines identified in solar-flare plasmas. Tables of transition probabilities for the B I, C I, N I, O I, and F I isoelectronic sequences are presented, and collision strengths and transition probabilities for Cr, Fe, and Ni ions of the Be I sequence are given. Similarities of tokamak and solar spectra are discussed, and it is shown how the atomic data presented may be used to determine ion abundances and electron densities in low-density plasmas.

Feldman, U.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

Martin, Marcel Nations↗

ESCA study of several fluorocarbon polymers exposed to atomic oxygen in low earth orbit or within or downstream from a radio-frequency oxygen plasma

The ESCA (electron spectroscopy for chemical analysis) spectra of films of Tedlar, tetrafluoroethylene-hexafluoropropylene copolymer (in the form of a Teflon FEP coating on Kapton H, i.e., Kapton F), and polytetrafluoroethylene (Teflon or Teflon TFE), exposed to atomic oxygen O(3P) either in LEO on the STS-8 Space Shuttle or within or downstream from a radio-frequency oxygen plasma, were compared. The major difference in surface chemistry of Tedlar induced by the various exposures to O(3P) was a much larger uptake of oxygen when etched either in or out of the glow of an O2 plasma than when etched in LEO. In contrast, Kapton F exhibited very little surface oxidation during any of the three different exposures to O(3P), while Teflon was scarcely oxidized.

Golub, Morton A.↗

Contamination, Transportation or Transmutation in LENR Material Analyses

LENR experiments using various loading and triggering mechanisms rely on a variety of elemental and isotopic assays to determine LENR effects. These assays include optical microscopy, Scanning Electron Microscopy with Energy Dispersive X-Ray Analysis (SEM/EDX), X-Ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). All of these methods observe the surface of a material. By dissolving or vaporizing the sample, Inductively Coupled Plasma Optical Element Spectroscopy (ICP-OES) can determine elemental composition (ppb) or with mass spectroscopy, isotopes (ICP/MS). One can use a focused ion beam (FIB) to cut open a sample and observe the “cut” with either SEM/EDX, or Time-of-Flight Secondary Ion Mass Spectroscopy (TOF-SIMS). High Purity Gamma Ray Spectroscopy (HPGe) and alpha/ beta Liquid Scintillator spectroscopy can be used. We’ve employed these assay methods in our NASA GRC research under both the Advanced Energy Conversion and Lattice Confinement Fusion Projects. However, there are limitations associated with each of these methods ranging from handling contamination, instrumental limitations including sensitivity and field of view, and sample preparation.

Low Energy Nuclear Reactions↗

Goals for the application of high-resolution X-ray spectroscopy to the diagnosis of stellar coronal plasmas

Examples are provided of how high-resolution X-ray spectra may be used to determine the temperature and emission measure distributions, electron densities, steady and transient flow velocities, and location of active regions in stellar coronas. For each type of measurement, the minimum spectral resolution required to resolve the most useful spectral features is estimated. In general, high sensitivity is required to obtain sufficient signal-to-noise to exploit the high spectral resolution. Although difficult, each measurement should be achievable with the instrumentation proposed for AXAF.

Linsky, Jeffrey L.↗

Pulse Detonation Rocket MHD Power Experiment

A pulse detonation research engine (MSFC (Marshall Space Flight Center) Model PDRE (Pulse Detonation Rocket Engine) G-2) has been developed for the purpose of examining integrated propulsion and magnetohydrodynamic power generation applications. The engine is based on a rectangular cross-section tube coupled to a converging-diverging nozzle, which is in turn attached to a segmented Faraday channel. As part of the shakedown testing activity, the pressure wave was interrogated along the length of the engine while running on hydrogen/oxygen propellants. Rapid transition to detonation wave propagation was insured through the use of a short Schelkin spiral near the head of the engine. The measured detonation wave velocities were in excess of 2500 m/s in agreement with the theoretical C-J velocity. The engine was first tested in a straight tube configuration without a nozzle, and the time resolved thrust was measured simultaneously with the head-end pressure. Similar measurements were made with the converging-diverging nozzle attached. The time correlation of the thrust and head-end pressure data was found to be excellent. The major purpose of the converging-diverging nozzle was to configure the engine for driving an MHD generator for the direct production of electrical power. Additional tests were therefore necessary in which seed (cesium-hydroxide dissolved in methanol) was directly injected into the engine as a spray. The exhaust plume was then interrogated with a microwave interferometer in an attempt to characterize the plasma conditions, and emission spectroscopy measurements were also acquired. Data reduction efforts indicate that the plasma exhaust is very highly ionized, although there is some uncertainty at this time as to the relative abundance of negative OH ions. The emission spectroscopy data provided some indication of the species in the exhaust as well as a measurement of temperature. A 24-electrode-pair segmented Faraday channel and 0.6 Tesla permanent magnet assembly were then installed on Marshall Space Flight Center's (MSFC's) rectangular channel pulse detonation research engine. Magnetohydrodynamic (MHD) electrical power extraction experiments were carried out for a range of load impedances in which cesium hydroxide seed (dissolved in methanol) was sprayed into the gaseous oxygen/hydrogen propellants. Positive power extraction was obtained, but preliminary analysis of the data indicated that the plasma electrical conductivity is lower than anticipated and the near-electrode voltage drop is not negligible. It is believed that the electrical conductivity is reduced due to a large population of negative OH ions. This occurs because OH has a strong affinity for capturing free electrons. The effect of near-electrode voltage drop is associated with the high surface-to-volume ratio of the channel (1-inch by 1-inch cross-section) where surface effects play a dominant role. As usual for MHD devices, higher performance will require larger scale devices. Overall, the gathered data is extremely valuable from the standpoint of understanding plasma behavior and for developing empirical scaling laws.

Litchford, Ron J.↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

High Resolution Soft X-Ray Spectroscopy and the Quest for the Hot (5-10 MK) Plasma in Solar Active Regions

We discuss the diagnostics available to study the 5–10 MK plasma in the solar corona, which is key to understanding the heating in the cores of solar active regions. We present several simulated spectra, and show that excellent diagnostics are available in the soft X-rays, around 100 A, as six ionisation stages of Fe can simultaneously be observed, and electron densities derived, within a narrow spectral region. As this spectral range is almost unexplored, we present an analysis of available and simulated spectra, to compare the hot emission with the cooler component. We adopt recently designed multilayers to present estimates of count rates in the hot lines, with a baseline spectrometer design. Excellent count rates are found, opening up the exciting opportunity to obtain high-resolution spectroscopy of hot plasma.

Giulio Del Zanna↗

The solar X-ray spectrum

The characteristics of X-ray emission from the normal corona are considered, giving attention to questions of spatial and spectral distribution. Aspects of X-ray emission from solar flares are also investigated. Details of X-ray spectroscopy for coronal plasma diagnosis are discussed, taking into account techniques, the diagnosis of equilibrium plasmas, and the diagnosis of nonthermal events. The study of continuum emission and line emission is reported along with investigations of departures from equilibrium.

Culhane, J. L.↗

Mars Surveyor Program '01 Mars Environmental Compatibility Assessment wet chemistry lab: a sensor array for chemical analysis of the Martian soil

The Mars Environmental Compatibility Assessment (MECA) instrument was designed, built, and flight qualified for the now canceled MSP (Mars Surveyor Program) '01 Lander. The MECA package consisted of a microscope, electrometer, material patch plates, and a wet chemistry laboratory (WCL). The primary goal of MECA was to analyze the Martian soil (regolith) for possible hazards to future astronauts and to provide a better understanding of Martian regolith geochemistry. The purpose of the WCL was to analyze for a range of soluble ionic chemical species and electrochemical parameters. The heart of the WCL was a sensor array of electrochemically based ion-selective electrodes (ISE). After 20 months storage at -23 degrees C and subsequent extended freeze/thawing cycles, WCL sensors were evaluated to determine both their physical durability and analytical responses. A fractional factorial calibration of the sensors was used to obtain slope, intercept, and all necessary selectivity coefficients simultaneously for selected ISEs. This calibration was used to model five cation and three anion sensors. These data were subsequently used to determine concentrations of several ions in two soil leachate simulants (based on terrestrial seawater and hypothesized Mars brine) and four actual soil samples. The WCL results were compared to simulant and soil samples using ion chromatography and inductively coupled plasma optical emission spectroscopy. The results showed that flight qualification and prolonged low-temperature storage conditions had minimal effects on the sensors. In addition, the analytical optimization method provided quantitative and qualitative data that could be used to accurately identify the chemical composition of the simulants and soils. The WCL has the ability to provide data that can be used to "read" the chemical, geological, and climatic history of Mars, as well as the potential habitability of its regolith.

Non-NASA Center↗

Deducing Electron Properties from Hard X-Ray Observations

X-radiation from energetic electrons is the prime diagnostic of flare-accelerated electrons. The observed X-ray flux (and polarization state) is fundamentally a convolution of the cross-section for the hard X-ray emission process(es) in question with the electron distribution function, which is in turn a function of energy, direction, spatial location and time. To address the problems of particle propagation and acceleration one needs to infer as much information as possible on this electron distribution function, through a deconvolution of this fundamental relationship. This review presents recent progress toward this goal using spectroscopic, imaging and polarization measurements, primarily from the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI). Previous conclusions regarding the energy, angular (pitch angle) and spatial distributions of energetic electrons in solar flares are critically reviewed. We discuss the role and the observational evidence of several radiation processes: free-free electron-ion, free-free electron-electron, free-bound electron-ion, photoelectric absorption and Compton backscatter (albedo), using both spectroscopic and imaging techniques. This unprecedented quality of data allows for the first time inference of the angular distributions of the X-ray-emitting electrons and improved model-independent inference of electron energy spectra and emission measures of thermal plasma. Moreover, imaging spectroscopy has revealed hitherto unknown details of solar flare morphology and detailed spectroscopy of coronal, footpoint and extended sources in flaring regions. Additional attempts to measure hard X-ray polarization were not sufficient to put constraints on the degree of anisotropy of electrons, but point to the importance of obtaining good quality polarization data in the future.

Kontar, E. P.↗