Search NASA⌕ Search

SEARCH · Search NASA

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Nonlinear, Human-Centered Approach to Motion Cueing with a Neurocomputing Solver

This paper discusses the continuation of research into the development of new motion cueing algorithms first reported in 1999. In this earlier work, two viable approaches to motion cueing were identified: the coordinated adaptive washout algorithm or 'adaptive algorithm', and the 'optimal algorithm'. In this study, a novel approach to motion cueing is discussed that would combine features of both algorithms. The new algorithm is formulated as a linear optimal control problem, incorporating improved vestibular models and an integrated visual-vestibular motion perception model previously reported. A control law is generated from the motion platform states, resulting in a set of nonlinear cueing filters. The time-varying control law requires the matrix Riccati equation to be solved in real time. Therefore, in order to meet the real time requirement, a neurocomputing approach is used to solve this computationally challenging problem. Single degree-of-freedom responses for the nonlinear algorithm were generated and compared to the adaptive and optimal algorithms. Results for the heave mode show the nonlinear algorithm producing a motion cue with a time-varying washout, sustaining small cues for a longer duration and washing out larger cues more quickly. The addition of the optokinetic influence from the integrated perception model was shown to improve the response to a surge input, producing a specific force response with no steady-state washout. Improved cues are also observed for responses to a sway input. Yaw mode responses reveal that the nonlinear algorithm improves the motion cues by reducing the magnitude of negative cues. The effectiveness of the nonlinear algorithm as compared to the adaptive and linear optimal algorithms will be evaluated on a motion platform, the NASA Langley Research Center Visual Motion Simulator (VMS), and ultimately the Cockpit Motion Facility (CMF) with a series of pilot controlled maneuvers. A proposed experimental procedure is discussed. The results of this evaluation will be used to assess motion cueing performance.

Telban, Robert J.↗

Adaptive filtering of biodynamic stick feedthrough in manipulation tasks on board moving platforms

A novel approach to suppress the effects of biodynamic interference is presented. An adaptive noise canceling technique is employed for substracting the platform motion correlated components from the control stick output. The effects of biodynamic interference and its suppression by adaptive noise cancellation has been evaluated in a series of tracking tasks performed in a moving base simulator. Simulator motions were in pitch, roll and combined pitch and roll. Human operator performance was assessed from the mean square values of the tracking error and the control activity. The tracking error and the total stick output signal were found to increase significantly with motion and to diminish substantially with adaptive noise cancellation, thus providing a considerable improvement in tracking performance under conditions in which platform motion were present. The adaptive filter was found to cause a significant increase in the cross-over frequency and decrease in the phase margin. Moreover, the adaptive filter was found to significantly improve the human operator visual motor response. This improvement is manifested as an increased human operator gain, a smaller time delay and lower pilot workload.

Velger, M.↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms

In this study, we demonstrate the ability of adjustable tuned mass dampers (TMDs) to reduce the platform motion of floating offshore wind turbines (FOWTs). The TMDs are located in the hull and provide control authority by varying the amount of water ballast and compressed air in a reservoir over time. The optimal TMD settings depend on the wind and wave conditions of the FOWT. We present an open-loop control scheme that changes the TMD natural frequency based on sea state and a simple method for estimating the peak wave period and significant wave height. The performance of this open-loop control is compared to ideal control of the TMDs (set knowing the exact sea state), a TMD with a constant natural frequency targeting the design load case with the greatest platform motion, and a baseline set of simulations of the platform without TMDs. The constant natural frequency case performs nearly as effectively as the actively controlled case, suggesting that the TMDs can be simply designed for extreme load conditions and provide consistent control over a range of environments; however, the methods used to find the optimal TMD parameters and estimate sea state statistics could be used in other aspects of FOWT control and design.

artificial intelligence↗

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Command profile for Galileo scan platform control

A recursive command profile is developed for the control of a two-degree-of-freedom scan platform mounted on a flexible structure. Perfect sensors and actuators are assumed for development and testing, and structural vibrations are minimized by actuator torque commands following a smooth torque-time profile. The integral of the smooth torque profile, the rate profile, is recursively generated by a piecewise constant second derivation, and the torque applied by the closk actuator is divided into three components. Results show that the smooth platform motion in response to the command profiles is what the Galileo control systems needs to avoid stator structural vibrations. Position, rate and acceleration profiles are also presented, and the resulting motion of the scan platform in response to command profiles is illustrated.

Man, G. K.↗

Visually guided control of movement in the context of multimodal stimulation

Flight simulation has been almost exclusively concerned with simulating the motions of the aircraft. Physically distinct subsystems are often combined to simulate the varieties of aircraft motion. Visual display systems simulate the motion of the aircraft relative to remote objects and surfaces (e.g., other aircraft and the terrain). 'Motion platform' simulators recreate aircraft motion relative to the gravitoinertial vector (i.e., correlated rotation and tilt as opposed to the 'coordinated turn' in flight). 'Control loaders' attempt to simulate the resistance of the aerodynamic medium to aircraft motion. However, there are few operational systems that attempt to simulate the motion of the pilot relative to the aircraft and the gravitoinertial vector. The design and use of all simulators is limited by poor understanding of postural control in the aircraft and its effect on the perception and control of flight. Analysis of the perception and control of flight (real or simulated) must consider that: (1) the pilot is not rigidly attached to the aircraft; and (2) the pilot actively monitors and adjusts body orientation and configuration in the aircraft. It is argued that this more complete approach to flight simulation requires that multimodal perception be considered as the rule rather than the exception. Moreover, the necessity of multimodal perception is revealed by emphasizing the complementarity rather than the redundancy among perceptual systems. Finally, an outline is presented for an experiment to be conducted at NASA ARC. The experiment explicitly considers possible consequences of coordination between postural and vehicular control.

Riccio, Gary E.↗

Electromagnetic-Guided Dynamic Multileaf Collimator Tracking Enables Motion Management for Intensity-Modulated Arc Therapy

Purpose: Intensity-modulated arc therapy (IMAT) is attractive because of high-dose conformality and efficient delivery. However, managing intrafraction motion is challenging for IMAT. The purpose of this research was to develop and investigate electromagnetically guided dynamic multileaf collimator (DMLC) tracking as an enabling technology to treat moving targets during IMAT. Methods and Materials: A real-time three-dimensional DMLC-based target tracking system was developed and integrated with a linear accelerator. The DMLC tracking software inputs a real-time electromagnetically measured target position and the IMAT plan, and dynamically creates new leaf positions directed at the moving target. Low- and high-modulation IMAT plans were created for lung and prostate cancer cases. The IMAT plans were delivered to a three-axis motion platform programmed with measured patient motion. Dosimetric measurements were acquired by placing an ion chamber array on the moving platform. Measurements were acquired with tracking, without tracking (current clinical practice), and with the phantom in a static position (reference). Analysis of dose distribution differences from the static reference used a {gamma}-test. Results: On average, 1.6% of dose points for the lung plans and 1.2% of points for the prostate plans failed the 3-mm/3% {gamma}-test with tracking; without tracking, 34% and 14% (respectively) of points failed the {gamma}-test. The delivery time was the same with and without tracking. Conclusions: Electromagnetic-guided DMLC target tracking with IMAT has been investigated for the first time. Dose distributions to moving targets with DMLC tracking were significantly superior to those without tracking. There was no loss of treatment efficiency with DMLC tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strain System for the Motion Base Shuttle Mission Simulator

The Motion Base Shuttle Mission Simulator (MBSMS) Strain System is an innovative engineering tool used to monitor the stresses applied to the MBSMS motion platform tilt pivot frames during motion simulations in real time. The Strain System comprises hardware and software produced by several different companies. The system utilizes a series of strain gages, accelerometers, orientation sensor, rotational meter, scanners, computer, and software packages working in unison. By monitoring and recording the inputs applied to the simulator, data can be analyzed if weld cracks or other problems are found during routine simulator inspections. This will help engineers diagnose problems as well as aid in repair solutions for both current as well as potential problems.

Huber, David C.↗

An Initial Examination of Roll-Lateral Coordination Motion Requirements in Flight Simulation

A piloted simulation that examined the effects of uncoordinated roll-lateral motion cues from a coordinated math model was conducted. The vehicle model represented a typical helicopter with satisfactory handling qualities in the roll-lateral axes. The task was a two-degree-of-freedom horizontal sidestep, where the pilot controlled lateral position through roll angle. The motion platform commands were varied via two motion control system gains. One gain reduced the ratio between platform roll angle to math model (and thus visual) roll angle. The other gain was placed on how much lateral platform movement would result from platform roll attitude in an attempt to align the apparent gravity vector vertically relative to the pilot. Gains from one to zero were examined in both axes. Thus, the true 1:1 motion case, where the motion cues matched the visual cues was evaluated. Pilots subjective ratings of motion fidelity matched well against an earlier developed motion fidelity criteria. Significant differences were noted in the fixed-base versus motion base configurations.

Schroeder, Jeffery A.↗

SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

HERO WEC Belt Test Data

The following submission includes raw and processed data from the 2024 Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) belt tests conducted using NREL's Large Amplitude Motion Platform (LAMP). A description of the motion profiles run during testing can be found in the run log document. Data was collected using NREL's Modular Ocean Data AcQuisition (MODAQ) system in the form of TDMS files. Data was then processed using Python and MATLAB and converted to MATLAB workspace, parquet, and csv file formats. During Data processing, a low pass filter was applied to each array and the arrays were then resampled to common 10Hz timestamps. A MATLAB data viewer script is provided to quickly visualize these data sets. The following arrays are contained in each test data file: - Time: Unix seconds timestamp - Test_Time: Time in seconds since beginning of test - POS_OS_1001: Encoder position in degrees (the encoder is located on the secondary shaft of the spring return and is driven by the winch after a 4.5:1 gear reduction) - LC_ST_1001: Anchor load cell data in lbf - PRESS_OS_2002: Air spring pressure in psi This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

1:50 Scale Testing of Three Floating Wind Turbines at MARIN and Numerical Model Validation Against Test Data

The primary goal of the basin model test program discussed herein is to properly scale and accurately capture physical data of the rigid body motions, accelerations and loads for different floating wind turbine platform technologies. The intended use for this data is for performing comparisons with predictions from various aero-hydro-servo-elastic floating wind turbine simulators for calibration and validation. Of particular interest is validating the floating offshore wind turbine simulation capabilities of NREL’s FAST open-source simulation tool. Once the validation process is complete, coupled simulators such as FAST can be used with a much greater degree of confidence in design processes for commercial development of floating offshore wind turbines. The test program subsequently described in this report was performed at MARIN (Maritime Research Institute Netherlands) in Wageningen, the Netherlands. The models considered consisted of the horizontal axis, NREL 5 MW Reference Wind Turbine (Jonkman et al., 2009) with a flexible tower affixed atop three distinct platforms: a tension leg platform (TLP), a spar-buoy modeled after the OC3 Hywind (Jonkman, 2010) and a semi-submersible. The three generic platform designs were intended to cover the spectrum of currently investigated concepts, each based on proven floating offshore structure technology. The models were tested under Froude scale wind and wave loads. The high-quality wind environments, unique to these tests, were realized in the offshore basin via a novel wind machine which exhibits negligible swirl and low turbulence intensity in the flow field. Recorded data from the floating wind turbine models included rotor torque and position, tower top and base forces and moments, mooring line tensions, six-axis platform motions and accelerations at key locations on the nacelle, tower, and platform. A large number of tests were performed ranging from simple free-decay tests to complex operating conditions with irregular sea states and dynamic winds.

17 WIND ENERGY↗

Yaw Motion Cues in Helicopter Simulation

A piloted simulation that examined the effects of yaw motion cues on pilot-vehicle performance, pilot workload, and pilot motion perception was conducted on the NASA Ames Vertical Motion Simulator. The vehicle model that was used represented an AH-64 helicopter. Three tasks were performed in which only combinations of vehicle yaw and vertical displacement were allowed. The commands issued to the motion platform were modified to present the following four motion configurations for a pilot located forward of the center of rotation: (1) only the linear translations, (2) only the angular rotation, (3) both the linear translations and the angular rotation, and (4) no motion. The objective data indicated that pilot-vehicle performance was reduced and the necessary control activity increased when linear motion was removed; however, the lack of angular rotation did not result in a measured degradation for almost all cases. Also, pilots provided subjective assessments of their compensation required, the motion fidelity, and their judgment of whether or not linear or rotational cockpit motion was present. Ratings of compensation and fidelity were affected only by linear acceleration, and the rotational motion had no significant impact. Also, when only linear motion was present, pilots typically reported the presence of rotation. Thus, linear acceleration cues, not yaw rotational cues, appear necessary to simulate hovering flight.

Schroeder, Jeffrey A.↗

Offshore Code Comparison Collaboration, Continuation: Phase II Results of a Floating Semisubmersible Wind System: Preprint

Offshore wind turbines are designed and analyzed using comprehensive simulation tools that account for the coupled dynamics of the wind inflow, aerodynamics, elasticity, and controls of the turbine, along with the incident waves, sea current, hydrodynamics, and foundation dynamics of the support structure. The Offshore Code Comparison Collaboration (OC3), which operated under the International Energy Agency (IEA) Wind Task 23, was established to verify the accuracy of these simulation tools [1]. This work was then extended under the Offshore Code Comparison Collaboration, Continuation (OC4) project under IEA Wind Task 30 [2]. Both of these projects sought to verify the accuracy of offshore wind turbine dynamics simulation tools (or codes) through code-to-code comparison of simulated responses of various offshore structures. This paper describes the latest findings from Phase II of the OC4 project, which involved the analysis of a 5-MW turbine supported by a floating semisubmersible. Twenty-two different organizations from 11 different countries submitted results using 24 different simulation tools. The variety of organizations contributing to the project brought together expertise from both the offshore structure and wind energy communities. Twenty-one different load cases were examined, encompassing varying levels of model complexity and a variety of metocean conditions. Differences in the results demonstrate the importance and accuracy of the various modeling approaches used. Significant findings include the importance of mooring dynamics to the mooring loads, the role nonlinear hydrodynamic terms play in calculating drift forces for the platform motions, and the difference between global (at the platform level) and local (at the member level) modeling of viscous drag. The results from this project will help guide development and improvement efforts for these tools to ensure that they are providing the accurate information needed to support the design and analysis needs of the offshore wind community.

17 WIND ENERGY↗