At least 55 records · Page 3

Technology Solutions Case Study: Sealed Air-Return Plenum Retrofit

In this project, Pacific Northwest National Laboratory researchers greatly improved indoor air quality and HVAC performance by replacing an old, leaky air handler with a new air handler with an air-sealed return plenum with filter; they also sealed the ducts, and added a fresh air intake.

air handler↗

CFD Analysis of RLUOB Zone 1 HEPA Filter Plenum and Testing Manifolds

The purpose of this computational fluid dynamics (CFD) analysis is to ensure that Camfil Farr’s upstream and downstream injection and sampling manifolds can meet or exceed the requirements outlined in the ASME AG-1 1997 a(2000) Code on Nuclear Air and Gas Treatment for the testing of HEPA and adsorbent filters. This paper will present a numerical simulation of airflow in the Radiological Laboratory Utility Office Building (RLUOB) zone 1 HEPA filter plenum and testing manifolds using the commercial CFD software ANSYS FLUENT 2020R1. The CFD analysis focuses on the investigation of the air flow distribution and air-aerosol mixing uniformity. The evaluation was done for all steps of the modeling process: grid generation, physics setup, simulation, and post-processing. The mass flow rate in each section of the zone 1 injection and sampling manifolds is also reported.

42 ENGINEERING↗

Rain-Blowing Plenum For Antenna Feed Horn

Double-diaphragm radome drives raindrops away from antenna feed horn. Includes solid diaphragm at mouth of feed horn surmounted by perforated diaphragm. Pressurized air in plenum between diaphragms flows out through perforations. Eliminates increase in noise temperature occuring when water covers radome. Useful for X-band and higher frequencies, susceptible to effects of water.

Hames, Peter S.↗

Effects of bleed-hole geometry and plenum pressure on three-dimensional shock-wave/boundary-layer/bleed interactions

A numerical study was performed to investigate 3D shock-wave/boundary-layer interactions on a flat plate with bleed through one or more circular holes that vent into a plenum. This study was focused on how bleed-hole geometry and pressure ratio across bleed holes affect the bleed rate and the physics of the flow in the vicinity of the holes. The aspects of the bleed-hole geometry investigated include angle of bleed hole and the number of bleed holes. The plenum/freestream pressure ratios investigated range from 0.3 to 1.7. This study is based on the ensemble-averaged, 'full compressible' Navier-Stokes (N-S) equations closed by the Baldwin-Lomax algebraic turbulence model. Solutions to the ensemble-averaged N-S equations were obtained by an implicit finite-volume method using the partially-split, two-factored algorithm of Steger on an overlapping Chimera grid.

Chyu, Wei J.↗

Emission Spectral Measurements in the Plenum of an Arc Jet Wind Tunnel

Arc jet wind tunnel facilities are used to evaluate thermal protection system materials for re-entry vehicles. The high speed, high temperature flowfield generated by the arc jet can simulate the extreme aerodynamic heating environment experienced during re-entry so that the survivability of heat shield materials and performance of various designs options can be tested. Although the re-entry heating environment can be approximated in the arc jet facility, the flowfield only partially simulates the actual re-entry flight conditions. Reynolds numbers are not matched so that surface shear stress distributions and mass transfer rates due to ablation or other mechanisms are not modeled correctly. Unlike flight conditions the arc freestream air is in non-equilibrium because of the rapid expansion that occurs in the supersonic nozzle. To properly study the actual re-entry flow environment, computational fluid dynamics, computational chemistry and radiation models must be used. Arc jet tunnel tests serve to validate these models. To perform accurate simulations inlet and boundary-conditions are needed, which come from measurements of the flowfield. The present study is concerned with measurements in the plenum region of an arc heater. In the past, conditions in the arc heater flowfield have been predicted using simulations since conventional measurement techniques could not be used in the harsh extremely high temperature environment. The present study is part of a recent push to utilize optical techniques to help better characterize the arc jet flowfields. Emission measurements have been made in the shock layer and the constrictor section of the arc heater to determine temperatures and species number densities. LIF measurements have been made in the free stream to determine temperature and velocity.

Donohue, Jim↗

It’s Hip To Be Square - Refurbishment of the NASA Langley National Transonic Facility Test Section Plenum Door

The “nearside” plenum door (NPD) at the 39-year-old NASA Langley Research Center (LARC) National Transonic Facility (NTF) has become increasingly recalcitrant during the opening /closing sequence. The NPD is the primary means of entry into the test section for personnel and for model installation. The sliding NPD hardware guide bearings have failed three (3) times within a one-year period and “quick fixes” were able to be made to guide rails, wheels and bearings to put the NPD back into operation. The NPD no longer can utilize a “quick fix” as the rolling hardware is at its limit for further modifications. This presentation will describe the NPD situation, the findings as to the cause of the periodic NPD failures, and the solution to remove, refurbish, and reinstall the NPD.

Test Facilities↗

Coupled computational fluid dynamics and heat transfer analysis of the VHTR lower plenum.

The very high temperature reactor (VHTR) concept is being developed by the US Department of Energy (DOE) and other groups around the world for the future generation of electricity at high thermal efficiency (> 48%) and co-generation of hydrogen and process heat. This Generation-IV reactor would operate at elevated exit temperatures of 1,000-1,273 K, and the fueled core would be cooled by forced convection helium gas. For the prismatic-core VHTR, which is the focus of this analysis, the velocity of the hot helium flow exiting the core into the lower plenum (LP) could be 35-70 m/s. The impingement of the resulting gas jets onto the adiabatic plate at the bottom of the LP could develop hot spots and thermal stratification and inadequate mixing of the gas exiting the vessel to the turbo-machinery for energy conversion. The complex flow field in the LP is further complicated by the presence of large cylindrical graphite posts that support the massive core and inner and outer graphite reflectors. Because there are approximately 276 channels in the VHTR core from which helium exits into the LP and a total of 155 support posts, the flow field in the LP includes cross flow, multiple jet flow interaction, flow stagnation zones, vortex interaction, vortex shedding, entrainment, large variation in Reynolds number (Re), recirculation, and mixing enhancement and suppression regions. For such a complex flow field, experimental results at operating conditions are not currently available. Instead, the objective of this paper is to numerically simulate the flow field in the LP of a prismatic core VHTR using the Sandia National Laboratories Fuego, which is a 3D, massively parallel generalized computational fluid dynamics (CFD) code with numerous turbulence and buoyancy models and simulation capabilities for complex gas flow fields, with and without thermal effects. The code predictions for simpler flow fields of single and swirling gas jets, with and without a cross flow, are validated using reported experimental data and theory. The key processes in the LP are identified using phenomena identification and ranking table (PIRT). It may be argued that a CFD code that accurately simulates simplified, single-effect flow fields with increasing complexity is likely to adequately model the complex flow field in the VHTR LP, subject to a future experimental validation. The PIRT process and spatial and temporal discretizations implemented in the present analysis using Fuego established confidence in the validation and verification (V and V) calculations and in the conclusions reached based on the simulation results. The performed calculations included the helicoid vortex swirl model, the dynamic Smagorinsky large eddy simulation (LES) turbulence model, participating media radiation (PMR), and 1D conjugate heat transfer (CHT). The full-scale, half-symmetry LP mesh used in the LP simulation included unstructured hexahedral elements and accounted for the graphite posts, the helium jets, the exterior walls, and the bottom plate with an adiabatic outer surface. Results indicated significant enhancements in heat transfer, flow mixing, and entrainment in the VHTR LP when using swirling inserts at the exit of the helium flow channels into the LP. The impact of using various swirl angles on the flow mixing and heat transfer in the LP is qualified, including the formation of the central recirculation zone (CRZ), and the effect of LP height. Results also showed that in addition to the enhanced mixing, the swirling inserts result in negligible additional pressure losses and are likely to eliminate the formation of hot spots.

08 HYDROGEN↗

OSU High Temperature Test Facility Test Acceptance Report, PG-28 Low Power (<350kW) Lower Plenum Mixing Test

Test Acceptance Report for Test PG-28 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OSU High Temperature Test Facility Test Acceptance Report, PG-30 Low Power (<350kW) Lower Plenum Mixing, Constant Temperature Test

Test Acceptance Report for Test PG-30 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An intelligent scanning algorithm for lost fuel rod recovery in the MYRRHA lower plenum

This paper presents a system for visualizing the interior structure of a vessel filled with a liquid metal. Due to the opaque and conductive nature of the medium, regular visualization systems based on cameras, electromagnetic or laser based techniques can't be used. The operation, strengths and weaknesses of an existing set-up are investigated by creating a scenario to find and extract a rectangular object inside the vessel in the shortest possible time. The main focus of this paper is not on designing a new system but to investigate the bottlenecks that are faced and need to be kept in mind in future designs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Swirling jets for the mitigation of hot spots and thermal stratification in the VHTR lower plenum

The Department of Energy (DOE) has a special interest in the development of Generation IV next generation nuclear plants (NGNPs) in the form of very high (gas cooled) temperature reactors (VHTRs) for the production of electricity, hydrogen, and process heat. As of 2010, the prismatic and pebble bed reactors are the top VHTR candidates [ORNL, 2010; Wikipedia, 2010a; World Nuclear News, 2010; Kinsey, 2010]. However, for reasons elucidated in Section 2, this research will concentrate on the prismatic core VHTR.

Rodriguez, Salvador B.↗