Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plume monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The feasibility of MT tipper data to monitor CO2 storage sites

Monitoring carbon storage sites using geophysical techniques is a critical component to the success and safety of storage programs. Currently, the primary methods of monitoring such sites are seismic and, to a much lesser extent, electromagnetics using active sources. The cost of such methods, especially seismic, can be prohibitively expensive. Natural source lectromagnetics, or magnetotellurics (MT), represents a low-cost, and underutilized method with the potential to aid CO2 monitoring efforts. Specifically, the tipper of MT data gives insight to the dimensionality of the subsurface and is able to detect the expansion front of a CO2 plume in a saline reservoir. We analyze the feasibility of using the tipper to monitor two shallow CO2 plumes and conclude that the tipper may be a suitable method for long-term monitoring.<br>

Kohnke, Colton↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Quantitative Approach for Demonstrating Plume Stabilization Under CCS Policy Frameworks

Conference presentation at Carbon Capture, Utilization, and Storage (CCUS) Conference 2024, Houston, Texas, March 11–13, 2024. The study highlighted the operator’s responsibilities for demonstrating plume stabilization in partial fulfillment of postinjection monitoring and site closure requirements. The metric dA/dt was chosen because of rules and regulations that call out the need to measure the change in area of the plume and plume extents over time. As dA/dt approached dA/dtcritical, the CO 2 plume’s growth was both minimal and predictable. Providing operators with a quantitative approach to determining plume stabilization is important for moving carbon capture and storage (CCS) projects beyond feasibility phases of development.

01 COAL, LIGNITE, AND PEAT↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

Raman Spectroscopy to Detect and Measure NOW Pheromones ("Orchard in a box")

Insect sex pheromones are chemical compounds that insects release to attract mates over distances of hundreds of meters or even kilometers, in complete darkness and without any audible signals. Use of synthetic forms of key compounds have in some cases become an essential component of monitoring and/or managing key pests of agricultural crops, including navel orangeworm (Amyelois transitella) (NOW) in California tree nuts. There are currently multiple commercially available mating disruption products available for NOW and recent studies have demonstrated that they can be effectively used to reduce crop damage. How mating disruption works is not fully established and likely varies across products and target species. For instance, it is not well understood how synthetic pheromones compete with natural pheromones and, in the case of monitoring, how efficaciously the insect follows the diffusing plumes, especially across large blocks and at plot borders. Whether an aerosol puffer is used for mating disruption or lure for monitoring population development, we currently lack the ability to fully understand how these synthetic pheromone compounds diffuse away from their point-source of emission – and subsequently how this might affect the efficacy of mating disruption and/or the accuracy of monitoring efforts. In response to these unknowns, Raman spectroscopy may offer a way to detect synthetic pheromone because of its analytical properties and recent technological advancements. In combination with nanostructured probes, RS has demonstrated the capability to detect volatiles at extremely low concentrations. We proposed to evaluate the use of Raman for the detection of synthetic and natural NOW pheromones and, were that to be successful, use this tool in subsequent years to measure pheromone diffusion in orchards.

47 OTHER INSTRUMENTATION↗

Cross-Well Seismic Monitoring of CO 2 Injected Into the A-1 Carbonate and Brown Niagaran Formations at the Chester 16 Reef

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. A cross-well seismic survey was acquired in the Chester 16 reef to attempt to locate 85,000 tonnes of carbon dioxide (CO 2 ) that were injected into the A-1 Carbonate and Brown Niagaran Formations earlier. The technique of conducting multiple cross-well seismic surveys over time, including a pre-CO 2 injection (baseline) survey, has been used elsewhere to monitor CO 2 injected into the subsurface. In this study, a baseline cross-well survey was not obtained; nevertheless, it was possible to generate an image that is a plausible representation of the CO 2 plume. This conclusion is supported by other monitoring and modeling results from the Chester 16 reef that provide an independent indication about the likely position of the injected CO 2 .

01 COAL, LIGNITE, AND PEAT↗

Integrated hydrogeophysical modelling and data assimilation for geoelectrical leak detection

Time-lapse electrical resistivity tomography (ERT) measurements provide indirect observations of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolution. ERT has been used in the past decades to detect leaks and monitor the evolution of associated contaminant plumes. Specifically, inverted resistivity images allow visualization of the dynamic changes in the structure of the plume. However, existing methods do not allow the direct estimation of leak parameters (e.g. leak rate, location, etc.) and their uncertainties. We propose an ensemble-based data assimilation framework that evaluates proposed hydrological models against observed time-lapse ERT measurements without directly inverting for the resistivities. Each proposed hydrological model is run through the parallel coupled hydro-geophysical simulation code PFLOTRAN-E4D to obtain simulated ERT measurements. The ensemble of model proposals is then updated using an iterative ensemble smoother. In this paper, we demonstrate the proposed framework on synthetic and field ERT data from controlled tracer injection experiments. Our results show that the approach allows joint identification of contaminant source location, initial release time, and solute loading from the cross-borehole time-lapse ERT data, alongside with an assessment of uncertainties in these estimates. We demonstrate a reduction in site-wide uncertainty by comparing the prior and posterior plume mass discharges at a selected image plane. This framework is particularly attractive to sites that have previously undergone extensive geological investigation (e.g., nuclear sites). It is well suited to complement ERT imaging and we discuss practical issues in its application to field problems.

58 GEOSCIENCES↗

Electrical monitoring of saline tracers to reveal subsurface flow pathways in a flat ditch-drained field

Time-lapse electrical resistivity imaging (ERI) combined with salt tracers can enhance our understanding of subsurface flow and transport in ditch-drained agroecosystems. In a nearly level field adjacent to a drainage ditch, we installed 192 electrodes in a 72-m2 plot along with five hydrometric stations to enable time-lapse ERI monitoring during storms. Immediately prior to a wintertime rainstorm, we applied 5 kg of KBr to a shallow trench located roughly 11 m upgradient from the ditch. Antecedent conditions prior to the storm were wet, assuring a hydrologically connected state that favored tracer dissolution and movement in the subsurface. We monitored the evolution of the tracer plume with ERI over a seven-day period. Four-dimensional (4D) delineation of precipitation and tracer transport using time-lapse ERI showed that the tracer plume moved preferentially downward through a discontinuity in the argillic horizon within the first 57 hrs. Over the following 79 hrs, the tracer plume exhibited steady, lateral movement towards the drainage ditch within a more permeable sandy horizon situated just below the argillic. A spatial moment analysis of logarithmic changes in conductivity in the sand layer revealed seepage velocities ranging from 0.0027 to 0.0482 m d-1; these values were positively correlated with hydraulic gradients, suggesting laminar flow processes typical of sandy aquifers. Increasing groundwater velocities with hydraulic gradients suggest that solute transfers from groundwater to ditch are likely to be faster in storms, especially during wet periods. Even so, predominantly slow lateral transport within the sandy horizon, even during storms, indicates that critical source areas of pollutant loss are likely within a few meters of the ditch.

Robinson, Judith L.↗

Evaluation of Improvements in Storage Efficiencies, Containment, Assurance, CO 2 Plume Movement, and Verification of Storage Technologies

This report summarizes some of the evolving improvements in key technical skills that are developing to support a large-scale commercial application of CCS as well as support rapidly increasing interest in carbon negative technologies. It does not attempt to review relatively well-known processes and procedures that are familiar to many CCS experts; rather focuses on novel concepts that have the potential to provide breakthroughs and add high benefit as projects evolve. Some elements described are in development or not yet proven ideas for which we provide an expression of status of confidence at the time of writing. Topics covered are evaluation of improvements in storage efficiency estimation, containment assurance methods, CO 2 plume movement and pressure prediction, and monitoring and verification of storage methods.

54 ENVIRONMENTAL SCIENCES↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

System and method thermopile energy harvesting for subsurface well bore sensors

A system and method for powering a borehole sensor with thermal energy is disclosed. The system includes a tubular pipe inserted into a subsurface borehole. A borehole casing is coaxially disposed with the tubular pipe. An annular space between the casing and the tubular pipe has a power source placed in the borehole to power a sensor in response to a temperature gradient between a surface of the casing and a surface of the tubular pipe. The method includes attaching thermopiles on the borehole casing or tubing; placing the thermopile in the annulus between the casing and the tubing; inducing a thermal gradient across the thermopile; generating an electrical energy in response to the temperature gradient; powering the sensor from the generated energy; and monitoring vertical expansion of a CO2 plume.

Bryan, Charles R.↗

Kilometer-Scale Hydrologic Exchange Flows in a Gravel Bed River Corridor and Their Implications to Solute Migration

In this work, a well-characterized field site along a major river corridor was used to investigate the dynamic pathways and impacts of subsurface hydrogeologic structures on kilometer-scale hydrologic exchange flows between river water and groundwater. A aqueous uranium (U aq ) plume exists at the site that discharges to the Columbia River. We performed temporally intensive monitoring of specific conductance (SpC) and U aq concentrations within the plume at increasing distances from the river shoreline and at locations both within and outside a presumed subsurface pathway of lateral hydrologic exchange. Specific conductance and U aq were utilized as in-situ tracers of hydrologic exchange and associated groundwater-surface water mixing. Monitoring data was collected for an approximate two year period during which seasonal river elevations varied by more than 2 m causing distinct events of river water intrusion and retreat from the near-shore aquifer, and large temporal variations in well-water analyte concentrations. Statistical clustering analysis was applied to identify well groupings exhibiting common time series behaviors. PFLOTRAN was implemented within a modeling domain of 3.3 x 1.9 km with dynamic flow boundary conditions and accurate subsurface topography for the basal aquitard underlying the aquifer. In-silico calculations of river water tracer behavior were performed to assess predominant flow directions and velocities influenced by river stage variations and variable aquitard topography, and their collective influences on SpC and U aq concentrations. We demonstrate complicated multidirectional flow behaviors at the kilometer scale resulting from hydrologic exchange and subsurface structure that influence plume dynamics and determine the overall system behavior.

54 ENVIRONMENTAL SCIENCES↗

Geospace Plume and Its Impact on Dayside Magnetopause Reconnection Rate

The role a geospace plume in influencing the efficiency of magnetopause reconnection is an open question with two contrasting theories being debated. A local-control theory suggests that a plume decreases both local and global reconnection rates, whereas a global-control theory argues that the global reconnection rate is controlled by the solar wind rather than local physics. Observationally, limited numbers of point measurements from spacecraft cannot reveal whether a local change affects the global reconnection. A distributed observatory is hence needed to assess the validity of the two theories. We use THEMIS and Los Alamos National Laboratory spacecraft to identify the occurrence of a geospace plume and its contact with the magnetopause. Global evolution and morphology of the plume is traced using GPS measurements. SuperDARN is then used to monitor the distribution and the strength of dayside reconnection. Two storm-time geospace plume events are examined and show that as the plume contacts the magnetopause, the efficiency of reconnection decreases at the contact longitude. The amount of local decrease is 81% and 68% for the two events, and both values are consistent with the mass loading effect of the plume if the plume's atomic mass is ~4 amu. Reconnection in the surrounding is enhanced, and when the solar wind driving is stable, little variation is seen in the cross polar cap potential. This study illuminates a pathway to resolve the role of cold dense plasma on solar wind-magnetosphere coupling, and the observations suggest that plumes redistribute magnetopause reconnection activity without changing the global strength substantially.

79 ASTRONOMY AND ASTROPHYSICS↗

Commercialization of the NLR Hydrogen Wide Area Monitor (HyWAM): Cooperative Research and Development (Final Report)

Hydrogen wide area monitoring refers to the temporal and quantitative 3-dimenasional spatial profiling of hydrogen plumes following either intentional or unintentional hydrogen releases. A hydrogen wide area monitor (HyWAM) would have applications as a research tool, for example to provide empirical data on the behavior of hydrogen dispersions following a release, which in turn can be used to validate modelling studies. Support of modeling studies and commercial applications are interrelated, since modeling can serve to guide HyWAM deployment for enhanced safety within medium to large scale hydrogen operations, such as those envisioned by H2@Scale.

08 HYDROGEN↗

Development and testing of a continuous maritime monitor for radionuclide aerosols

Monitoring airborne concentrations of radionuclide activity may provide a timely warning to sea-based assets to avoid contamination from a radioactive plume. The development and testing of an automated aerosol monitoring system that can capture and detect radioactive particulate from marine air is presented. A custom electrostatic precipitator (ESP) was designed to capture particulate onto a reusable collection media. The collection efficiency of the ESP system for radon progeny was determined to be ~23%. A conservative calculation of the minimum detectable concentration of 214 Bi was estimated as 0.3-8 Bq/m 3 . The system was demonstrated in continuous operation, without consumables and limited maintenance, in a marine environment at the PNNL campus in Sequim, Washington. In conclusion, a successful 2-month deployment indicates the feasibility of the approach for continuous maritime monitoring for radionuclide aerosols.

Moore, Michael E. [Pacific Northwest National Labo↗

Time-Lapse Vertical Seismic Profiling (VSP) for CO 2 Storage in a Depleted Oil Field in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report describes the Dover 33 VSP study to test the effectiveness of time-lapse Vertical Seismic Profile (VSP) for detecting and delineating a plume of more than 271,000 tonnes of CO2 injected into the Brown Niagaran and A-1 Carbonate formations within the Dover 33 reef between March 2013 and September 2016. Five 2D walkaway VSP (WVSP) source lines were acquired by SIGMA3 in September 2016 to investigate the possible time-lapse response in both P-wave and PS-wave seismic data. The data was compared to the same survey geometry acquired in March 2013 by SR2020. The seismic energy was recorded into an 80-level, three-component geophone array deployed into the Dover 1-33 well and placed just above the reef. P-wave and PS-wave reflection images were produced for each of the three source lines from both the 2013 baseline and 2016 monitor surveys. The images were then compared to look for changes in the reflectivity at and around the injection location that might indicate how the CO 2 has moved over this time period. This technique revealed several localized areas with sizable impedance differences inside the reef where CO 2 would be expected; however, a large number of similar impedance “hotspots” were also detected outside the reef in areas where injected CO 2 would not be expected. Therefore, a second analysis that involved calculating P-wave and S-wave travel time differences between the 2013 and 2016 VSPs was conducted to look for a change that could be caused by the CO 2 plume.

01 COAL, LIGNITE, AND PEAT↗

Quantifying CO 2 Plume Stabilization at Carbon Storage Projects, North Dakota, USA

This study presents an approach for quantifying when injected carbon dioxide (CO 2 ) stabilizes pursuant to carbon capture and storage (CCS) project permitting and site closure requirements. The distribution of mobile-phase CO 2 (CO 2 plume) will evolve within the storage reservoir during and after injection through both physical and chemical trapping mechanisms. CCS policies generally agree that the CO 2 plume’s migratory behavior in post-injection should demonstrate nonendangerment to the environment but do not provide specific guidance on how to meet the definition of plume stabilization, generating some uncertainty for operators. Plume stability herein means the CO 2 plume 1) changes size minimally and predictably in the storage reservoir such that it will not cross key boundaries identified in the permit and 2) does not pose a threat to human health, underground sources of drinking water (USDWs), and the environment because of lateral migration to areas where leakage pathways may exist. Published literature on plume metrics was reviewed to determine which metric(s) may be most appropriate for determining CO 2 plume stability. A technical approach that defines plume stabilization by estimating the rate of change in the geographic footprint of the CO 2 plume with respect to time was developed and illustrated using a case study from North Dakota, USA, as a proposed solution for CCS operators to apply at the project permitting stage. Any prospective CCS operator may benefit from using the same approach to inform the selection of pore space lease and monitoring areas and develop post-injection site care plans.

03 NATURAL GAS↗

Spatiotemporal Analyses of Groundwater and Shoreline Cr(VI) Concentrations in the 100 Areas at Hanford

Cleanup efforts have been ongoing since the late 1990s to remediate contaminated waste sites and groundwater in the 100 Areas at the U.S. Department of Energy (DOE) Hanford Site. One of the primary contaminants of concern is hexavalent chromium (Cr(VI)), which was used as a corrosion inhibitor in cooling water for nuclear reactors that formerly operated along the shoreline of the Columbia River. Cleanup efforts have included 1) removal, treatment (as needed), and disposal of contaminated sediments; 2) in situ redox manipulation as a permeable reactive barrier; 3) pump-and-treat; 4) soil flushing; and 5) monitored natural attenuation. DOE’s annual groundwater monitoring reports document the significant reductions in Cr(VI) plume areas that have occurred over the past 10 years or more as a result of these cleanup efforts. The Record of Decision for the 100-HR-3 operable unit specified a cleanup level (CUL) for Cr(VI) in groundwater of 48 µg/L to protect human receptors, and a surface water CUL of 10 µg/L to protect aquatic organisms in the Columbia River. The Record of Decision did not specify point-of-compliance locations for the surface water CUL. Data for 2019 from the six groundwater operable units (OUs) in the 100 Areas indicate that the 48 μg/L groundwater CUL has been achieved in 100% of the wells in the 100-BC and 100-NR OUs, and in 89- 97% of the wells in the other OUs (100-KR, 100-HR-D, 100-HR-H, 100-FR). Data for 2019 indicate that 100% of the aquifer tubes monitored for Cr(VI) in the 100 Areas have concentrations below the 48 μg/L groundwater CUL. However, the 10 μg/L standard has not yet been consistently achieved for both inland groundwater monitoring wells and shoreline aquifer tubes. This report describes a series of data analyses performed to identify consistent relationships, if any, between inland well and shoreline Cr(VI) concentrations within the 100 Areas. To this end, select monitoring data for Cr(VI) measured in groundwater and aquifer tubes at the 100 Areas were analyzed for a 10-year period—2010 to 2019. Relationships between inland groundwater plumes and surface-water points of discharge in and along the Columbia River were examined through several analyses that included inland well and aquifer tube concentrations as a function of distance from the shoreline, evaluation of cumulative probability plots, trend analysis, correlation analysis, cluster analysis, and identification of plume trajectories for each of the 100 Areas. The analyses did not identify consistent relationships between inland groundwater Cr(VI) concentrations and shoreline concentrations within the 100 Areas due to several confounding factors influencing groundwater flow directions and Cr(VI) concentrations. The proximity of groundwater Cr(VI) plumes to the river, and the highly dynamic nature of the river, influence the transport behavior of the plumes and create challenges for quantifying attenuation of Cr(VI) between the inland monitoring wells and shoreline concentrations. Other factors contributing to temporal and spatial Cr(VI) concentrations, as supported by some of the data analyses, include the presence of vadose zone sources, variable sorption behavior, and complexities associated with Cr(VI) mass transfer between the upper and lower aquifers and their interactions with the river. Hence, monitoring to assess compliance with target CULs will need to be determined for each area individually since several factors influence Cr(VI) concentrations in the 100 Areas.

54 ENVIRONMENTAL SCIENCES↗