Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Burst Chasing X-ray Polarimeter

Tihs is a viewgraph presentation of a discussion of the X-ray Polarimeter. Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect is the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

Hill, Joanne↗

Performance of the PRAXyS X-Ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

PRAXyS↗

Investigation of the Potential for Lidar & Polarimeter Combined Aerosol Retrievals Using Various Instrument Combinations

As a scientific community, we are motivated to achieve better observational capabilities for aerosols, to reduce uncertainties about aerosol’s role in climate. Encouraged by the National Academies Decadal Survey, many are looking to the synergy of lidar and polarimeter as a means of achieving improved measurements. Polarimetric observations of total-column radiances have excellent sensitivity to aerosol size distribution and absorption properties. Active lidar measurements have fewer wavelengths and view angles and therefore more limited sensitivity to aerosol microphysical properties such as complex refractive index. Yet the advantage of vertically resolved profiles is game-changing, especially given that models contain significant uncertainty about the vertical distribution of aerosol and that polarimeter and other passive retrievals must make assumptions about vertical distribution which can impact performance. To optimize the synergy, a joint polarimeter + lidar mission requires a joint retrieval. However, the exact instruments that will be launched on a future satellite are unknown, and the capabilities of polarimeters and lidars cover a large range. In this study, we perform information content analysis for a range of nominal instrument combinations. The methodology is ideal for assessing the impact of measurements and a priori information (assumptions and constraints) with respect to the desired retrieval products, and for comparing measurement systems. It has advantages that make it useful in advance of or in parallel with retrieval development, such as producing quantitatively useful comparisons even for retrieval scenarios that are significantly underdetermined and therefore impossible to retrieve without significant assumptions, and it is not impacted by retrieval-specific sources of error such as incomplete or incorrect convergence which can complicate the interpretation of a retrieval performance analysis. Here, we will derive the expected uncertainty in retrieved aerosol concentration, effective radius, fine mode fraction and single scattering albedo, for a combination of a polarimeter with various grades of lidar, from an elastic backscatter lidar, similar to the pathfinder CALIOP on the CALIPSO satellite, to a multi-wavelength high spectral resolution lidar.

Sharon P Burton↗

Models comparison for JET polarimeter data

A complete comparison between the theory and the measurements in polarimetry was done by using the Far Infrared Polarimeter at JET. More than 300 shots were analyzed, including a wide spectrum of JET scenarios in all critical conditions for polarimetry: high density, high and very low fields, high temperatures.This work is aimed at the demonstration of the robustness of the theoretical models for the JET polarimeter measurements in the perspective of using these models for ITER like plasma scenarios . In this context, an assessment was performed on how the line-integrated plasma density along the central vertical chord of FIR polarimeter could be evaluated using the Cotton-Mouton effect and its possible concrete use to correct fringe jumps of the interferometer.The models considered are: i) the rigorous numerical solution of the Stokes propagation equations, using dielectric tensor evaluated from JET equilibrium and Thomson scattering [1,2]; ii) two types of approximated solutions [2,3] and iii) the Guenther empirical model [4] that considers the mutual effect between Cotton-Mouton and Faraday rotation angle. The model calculations have been compared with polarimeter measurements for the Cotton-Mouton phase shift.The agreement with theory is satisfactory within the limits of experimental errors [3].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Soft X-ray Polarimeter and Applications at BSRF

A novel compact polarimeter for the use in soft x-ray region having high-precision eight-axis automatically driven and two-axis manually driven equipped with multilayer polarizers was developed at the Beijing Synchrotron Radiation Facility (BSRF). The polarimeter was designed to utilize reflection and transmission geometry. Four operational modes have been designed and carried out with the polarimeter. Some experiments have been performed by using this polarimeter with various modes.

43 PARTICLE ACCELERATORS↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n{sub e}, electron temperature, T{sub e}, and total plasma current, I{sub p}) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explained. The measurement method that the authors have proposed is suitable for the reactor for the following reasons; multiparameters can be obtained from a small number of diagnostics, the proposed method does not depend on time-history, and far-infrared light utilized by the polarimeter is less sensitive to degradation of of optical components. Taking into account the measuring error, performance assessment of the proposed method was carried. Assuming that the error of Δθ and Δε were 0.1° and 0.6°, respectively, the error of reconstructed j{sub φ}, n{sub e} and T{sub e} were 12 %, 8.4 % and 31 %, respectively. This study has shown that the reconstruction error can be decreased by increasing the number of the wavelength of the probing laser and by increasing the number of the viewing chords. For example, By increasing the number of viewing chords to forty-five, the error of j{sub φ}, n{sub e} and T{sub e} were reduced to 4.4 %, 4.4 %, and 17 %, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarimeters and Energy Spectrometers for the ILC Beam Delivery System

This article gives an overview of current plans and issues for polarimeters and energy spectrometers in the Beam Delivery System of the ILC. It is meant to serve as a useful reference for the Detector Letter of Intent documents currently being prepared. Concepts for high precision polarization and energy measurements exist. These concepts have resulted in detailed system layouts that are included in the RDR description for the Beam Delivery System. The RDR includes both upstream and downstream polarimeters and energy spectrometers for both beams. This provides needed complementarity and redundancy for achieving the precision required, with adequate control and demonstration of systematic errors. The BDS polarimeters and energy spectrometers need to be a joint effort of the ILC BDS team and the Detector collaborations, with collaboration members responsible for the performance and accuracy of the measurements. Details for this collaboration and assigning of responsibilities remain to be worked out. There is also a demonstrated need for Detector physicists to play an active role in the design and evaluation of accelerator components that impact beam polarization and beam energy capabilities, including the polarized source and spin rotator systems. A workshop was held in 2008 on ILC Polarization and Energy measurements, which resulted in a set of recommendations for the ILC design and operation. Additional input and action is needed on these from the Detector collaborations, the Research Director and the GDE. Work is continuing during the ILC engineering design phase to further optimize the polarimeter and energy spectrometer concepts and fully implement them in the ILC. This includes consideration for alternative methods, detailed design and cost estimates, and prototype and test beam activities.

43 PARTICLE ACCELERATORS↗

Airborne Polarimeter Intercomparison for the NASA Aerosols-Clouds-Ecosystems (ACE) Mission

The Aerosols-Clouds-Ecosystems (ACE) mission, recommended by the National Research Council's Decadal Survey, calls for a multi-angle, multi-spectral polarimeter devoted to observations of atmospheric aerosols and clouds. In preparation for ACE, NASA funds the deployment of airborne polarimeters, including the Airborne Multi-angle SpectroPolarimeter Imager (AirMSPI), the Passive Aerosol and Cloud Suite (PACS) and the Research Scanning Polarimeter (RSP). These instruments have been operated together on NASA's ER-2 high altitude aircraft as part of field campaigns such as the POlarimeter DEfinition EXperiment (PODEX) (California, early 2013) and Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS, California and Texas, summer 2013). Our role in these efforts has been to serve as an assessment team performing level 1 (calibrated radiance, polarization) and level 2 (retrieved geophysical parameter) instrument intercomparisons, and to promote unified and generalized calibration, uncertainty assessment and retrieval techniques. We will present our progress in this endeavor thus far and describe upcoming research in 2015.

ACE↗

Progress in Airborne Polarimeter Inter Comparison for the NASA Aerosols-Clouds-Ecosystems (ACE) Mission

The Aerosols-Clouds-Ecosystems (ACE) mission, recommended by the National Research Council's Decadal Survey, calls for a multi-angle, multi-spectral polarimeter devoted to observations of atmospheric aerosols and clouds. In preparation for ACE, NASA funds the deployment of airborne polarimeters, including the Airborne Multiangle SpectroPolarimeter Imager (AirMSPI), the Passive Aerosol and Cloud Suite (PACS) and the Research Scanning Polarimeter (RSP). These instruments have been operated together on NASA's ER-2 high altitude aircraft as part of field campaigns such as the POlarimeter DEfinition EXperiment (PODEX) (California, early 2013) and Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS, California and Texas, summer 2013). Our role in these efforts has been to serve as an assessment team performing level 1 (calibrated radiance, polarization) and level 2 (retrieved geophysical parameter) instrument intercomparisons, and to promote unified and generalized calibration, uncertainty assessment and retrieval techniques. We will present our progress in this endeavor thus far and describe upcoming research in 2015.

Airborne↗

Direct Comparison of M\o ller and Compton Polarimeters in Hall C at Jefferson Lab

Knowledge of the electron beam polarization is one of the most important systematic uncertainties in precision, parity-violating electron scattering experiments with next generation experiments aiming to measure the electron beam polarization to better than 0.5\%. At high energies, the most typical polarimetry techniques are M\o ller (polarized electron-electron) and Compton (polarized electron-photon) scattering. The use of two techniques with different systematic uncertainties provides confidence in the extracted beam polarization. Direct comparisons of the two polarimetry techniques are challenging in that Compton polarimeters typically desire maximum beam flux (high beam currents) while M\o ller polarimeters need to limit the beam current to avoid depolarization effects in the target. We have performed a direct comparison of the M\o ller and Compton polarimeters in experimental Hall C at Jefferson Lab. This test is unique in that the data were taken sequentially under identical beam conditions at ?4.5~?A. We found excellent agreement between the Hall C M\o ller and Compton polarimeters. Combined with high-current Compton data, we were also able to limit the beam current dependence of the beam polarization to 1\% or less up to a beam current of 180~?A.

Gaskell, David↗

Optical polarimeters in space

A review is presented of the instrumentation used for the measurement of optical polarization from aircraft, balloon, rocket, satellite, and spacecraft platforms. The four parameters which can be measured at a given wavelength, time, and direction in an incoherent beam of radiation include intensity, linear polarization, its position angle, and circular polarization. An instrument that by design is made sensitive to any of the three polarization parameters is considered a polarimeter. Attention is given to passive polarimeters operating in the range from 0.1 to 1000 micrometers. All known optical space polarimeters are listed in a table. Questions of instrument operation in space are discussed along with details of polarization analysis, aspects of accuracy and calibration, and the scientific studies conducted with the polarimeters.

Coffeen, D. L.↗

X-ray polarimeters

The paper presents the theory, design, performance parameters, and statistical limitations of dispersive-crystal and Thomson-scattering devices as X-ray polarimeters for solar and extrasolar observations. With reference to the Bragg crystal polarimeter, the instrument parameters of the OSO-8 polarimeter are reported along with estimates of the minimum detectable polarization for several sources as derived from measured values for the integral reflectivities, the known spectra for a number of X-ray sources, and crystal panel geometry. For the Thomson-scattering polarimeter, values are given for the scattering efficiency for hydrogen and lithium as a function of photon energy and for the spectra of the two brightest X-ray sources: Sco X-1 and the Crab Nebula.

Silver, E. H.↗

Analysis of the new polarimeter for the Marshall Space Flight Center vector magnetograph

The magnetograph was upgraded in both electronic control of the magnetograph hardware and in the polarization optics. The problems associated with the orignal polarimeter were: (1) field of view errors associated with the natural birefringence of the KD*P crystals; (2.) KD*P electrode failure due to the halfwave dc voltage required in one of the operational sequences; and (3) breakdown of the retardation properties of some KD*Ps when exposed to a zero to halfwave modulation (DC) scheme. The new polarimeter gives up the flexibility provided by two variable waveplates to adjust the retardances of the optics for a particular polarization measurement, but solves the problems associated with the original polarimeter. With the addition of the quartz quarterwave plates, a new optical alignment was developed to allow the remaining KD*P to correct for errors in the waveplates. The new optical alignment of the polarimeter is prescribed. The various sources of error, and how those errors are minimized so that the magnetograph can look at the transverse field in real time are discussed.

West, E. A.↗

A 100-micron polarimeter for the Kuiper Airborne Observatory

Consideration is given to the design and performance of the 100-micron polarimeter proposed for use on the NASA Kuiper Airborne Observatory. The polarimeter specifications are listed. The polarimeter design and data reduction techniques are based on the work of Hildebrand et al. (1984) and Dragovan (1986). The polarimeter has an improved signal-to-noise ratio and systematic measurement errors below 0.2 percent.

Novak, G.↗

SOLPOL: A Solar Polarimeter for Hard X-Rays and Gamma-Rays

Th goal of this project was to continue the development of a hard X-ray polarimeter for studying solar flares. In earlier work (funded by a previous SR&T grant), we had already achieved several goals, including the following: 1) development of a means of producing a polarized radiation source in the lab that could be used for prototype development; 2) demonstrated the basic Compton scatter polarimeter concept using a simple laboratory setup; 3) used the laboratory results to verify our Monte Carlo simulations; and 4) investigated various detector technologies that could be incorporated into the polarimeter design. For the current one-year program, we wanted to fabricate and test a laboratory science model based on our SOLPOL (Solar Polarimeter) design. The long-term goal of this effort is to develop and test a prototype design that could be used to study flare emissions from either a balloon- or space-borne platform. The current program has achieved its goal of fabricating and testing a science model of the SOLPOL design, although additional testing of the design (and detailed comparison with Monte Carlo simulations) is still desired. This one-year program was extended by six months (no-cost extension) to cover the summer of 1999, when undergraduate student support was available to complete some of the laboratory testing.

McConnell, Michael L.↗

Calibration of Passive Microwave Hybrid Coupler-based Polarimeters

Passive microwave polarimeters, or polarimetric radiometers, are important tools for Earth remote sensing. They have found utility in ocean surface wind-vector remote sensing and polarization basis rotation systems for compensating instrument or ionospheric induced rotation. The hybrid coupler-based polarimeter is a specific class of polarimeter that utilizes a 180-degree hybrid coupler to affect a correlation between the received vertical and horizontal polarization signals. This type of polarimeter requires at least four calibration states for complete calibration. One state must be a polarized signal, such as the application of a correlated noise source. The phase balance of the noise source directly determines the quality of the calibration.

Piepmeier, J. R.↗