Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multifunctional polymer dispersions for biomedical assays obtained by heterophase radical polymerization

Methods for the preparation of multifunctional dispersions of polymer particles (DPP) in the course of free radical heterophase polymerization, which provides careful control of both macromolecular and colloidal properties, are considered. Approaches that, according to the polymerization technique, make it possible to control the particle diameter and shape, particle size distribution, colloidal stability, morphology, surface chemistry and functionality, as well as the formation of organo-inorganic hybrid particles, are demonstrated. The possibilities of DPP application in homogeneous and heterogeneous assays and cell labelling are reviewed. The use of DPP leads to decrease the reaction scales and costs and to increase the speed, sensitivity, selectivity, and reproducibility of assays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nozzle clogging factors during fused filament fabrication of spherical particle filled polymers

Fused filament fabrication with reinforced or filled polymers provides improved material properties compared to ordinary feedstock. A current limitation of these materials is the occurrence of nozzle clogging at higher filler contents. In this paper, an experiment is designed to identify the factors causing nozzle clogging. Glass sphere-filled polycarbonate is investigated by varying nozzle and filler diameters, the resin viscosity, the filler content, and the extrusion pressure. Equations identifying nozzle clogging and intermittent clogging conditions are provided. Based on these results, a model for the clogging of sphere-filled polymers is proposed. Last, a mathematical model is derived, which approximates the printability of filled polymers without the preparation of composites. Finally, this model is based on the nozzle geometry, the filler type and content, the resin viscosity, and the printer’s maximum extrusion force.

36 MATERIALS SCIENCE↗

Nano-Particle Enhanced Polymer Materials for Space Flight Applications

Recent advances in materials technology both in polymer chemistry and nano-materials warrant development of enhanced structures for space flight applications. This work aims to develop spacecraft structures based on polymer matrix composites (PMCs) that utilize these advancements.. Multi-wall carbon nano-tubes (MWCNTs) are expected ·to increase mechanical performance, lower coefficient of thermal expansion (CTE), increase electrical conductivity (mitigate electrostatic charge), increase thermal conductivity, and reduce moisture absorption of the resultant space structures. In this work, blends of MWCNTs with PETI-330 were prepared and characterized. The nano-reinforced resins were then resin transfer molded (RTM) into composite panels using M55J carbon fabric and compared to baseline panels fabricated from a cyanate ester (RS-3) or a polyimide (PETI-330) resin containing no MWCNTs. In addition, methods of pre-loading the fabric with the MWCNTs were also investigated. The effects of the MWCNTs on the resin processing properties and on the composite end-use properties were also determined.

Criss, Jim M., Jr.↗

Role of Particle Size and Polymer Length in Rheology of Colloid–Polymer Composites

The effect of particle size on the flow properties of composite melts is explored. In this study we investigate a system composed of silica particles with diameter D c = 127–730 nm in unentangled poly(ethylene glycol) of two molecular weights (400 with degree of polymerization ~9 and 2000 with degree of polymerization of 45). At low concentration, silica particles are stabilized by the adsorbed polymer layer as indicated by intrinsic viscosities slightly larger than the Einstein value of 2.5. Huggins coefficients indicate that at low concentration in PEG400 the particles behave very much like hard spheres, while in PEG2000 the particles experience very weak attractions. At high volume fraction, the absorbed polymer layers begin to interact such that hard-sphere scaling no longer applies to linear and nonlinear rheological responses. In PEG2000, at elevated volume fractions, the particles with stronger attractions experience kinetic arrest with average particle surface separations much larger than the polymer radius of gyration, R g . We show that the linear rheology, yielding behavior, and shear thickening response of dense composites are varied with R g / D c , with volume exclusion glass formation observed at low R g / D c and gelation at high R g /D c , and with yielding and shear thickening properties changed by R g and D c independently. The polymer layers are found to alter the approach to the jamming transition even for R g / D c as small as 6 × 10 –3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic conductivity optimization of composite polymer electrolytes through filler particle chemical modification

The addition of filler particles to polymer electrolytes is known to increment their ionic conductivity (IC). A detailed understanding of how the interactions between the constituent materials are responsible for the enhancement remains to be developed. A significant contribution is ascribed to an increment of the polymer amorphous fraction, induced by the fillers, resulting in the formation of higher ionic conductivity channels in the polymer matrix. However, the dependence of IC on the particle weight load and its composition on the polymer morphology is not fully understood. This work investigates Li-ion transport in composite polymer electrolytes (CPE) comprising Bi-doped LLZO particles embedded in PEO:LiTFSI matrixes. We find that the IC optimizes for very low particle weight loads (5-10%) and that both its magnitude and the load are required, strongly dependent on the garnet particle composition. Based on structural characterization results and electrochemical impedance spectroscopy, a mechanism is proposed to explain these findings. It is suggested that the Li-molar content in the garnet particle controls its interactions with the polymer matrix, resulting at the optimum loads reported, in the formation of high ionic conductivity channels. We propose that filler particle chemical manipulation of the polymer morphology is a promising avenue for the further development of composite polymer electrolytes.

bismuth↗

Fine-tuning of process conditions to improve product uniformity of polystyrene particles used for wind tunnel velocimetry

Monodisperse polymer particles (having uniform diameter) were used for the last two decades in physical, biological, and chemical sciences. In NASA Langley Research Center monodisperse polystyrene particles are used in wind tunnel laser velocimeters. These polystyrene (PS) particles in latex form were formulated at the Engineering Laboratory of FENGD using emulsion-free emulsion polymerization. Monodisperse PS latices particles having different particle diameters were formulated and useful experimental data involving effects of process conditions on particle size were accumulated. However, similar process conditions and chemical recipes for polymerization of styrene monomer have often yielded monodisperse particles having varying diameters. The purpose was to improve the PS latex product uniformity by fine-tuning the process parameters based on the knowledge of suspension and emulsion polymerization.

Ray, Asit K.↗

Perspectives on Polyolefin Catalysis in Microfluidics for High-Throughput Screening: A Minireview

Polyolefins are the largest produced plastics in the world which traditionally employ continuous stirred tank reactors and fluidized bed reactors for commercial production. The operating condition, reaction kinetics, and molecular interactions inside the reactor strongly affect the polyolefin properties, which require stringent process control in conventional procedures. Understanding the catalytic pathway, behavior of polymer particles and effect of reactor conditions are essential for designing specific polymer properties, namely the molecular weight, chain length, polydispersity, etc. Microfluidics can play a significant role in designing polymers tailored to the user needs. Smaller channel dimensions help obtain uniform reaction conditions over the length of the microfluidic reactor in a controlled environment. With real-time monitoring techniques in microfluidics, even single particle growth of polymer can be studied to understand the parameters affecting the polymer properties. High throughput microfluidics can help catalyst screening in a short duration with less consumption of reagents generating less waste. When supplemented with efficient machine learning algorithms, automated high throughput microfluidics has the potential to rapidly optimize the process and develop new knowledge even with a limited data set. When trained on data sets generated using microfluidic experiments that are designed efficiently with working knowledge of the process, machine learning algorithms can provide the relationship between the multivariable parameters space and polymer properties, which is not possible with the traditional statistical methods and interpolation techniques. Here, the rise in the utilization of microfluidics, with the advancement of machine learning algorithms, for polyolefin catalysis, highlights the importance of microfluidics for catalyst discovery, parameter optimization, and understanding reaction pathway for producing polymers with specific properties for specialized applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electroacoustics of Particles Dispersed in Polymer Gel

This study examines the acoustic electrophoresis of particles dispersed in polymer hydrogels, with the particle size either less than or greater than the gel mesh size. When the particles are smaller than the gel mesh size, their acoustic vibration is resisted by only the background water medium, and the measured dynamic electrophoretic mobility, μd (obtained in terms of colloid vibration current, CVI), is the same as in water. For the case of particles larger than the gel mesh size, μd is decreased due to trapping, and the net decrease depends on the viscoelastic properties of the gel. The gel mesh size was varied by varying its crosslink density, the latter being characterized as the storage modulus, G’. The dependence of mobility on G’, for systems of a given particle size, and on particle size, for gels of a given G’, are investigated. The measured mobility remains constant as G’ is increased (i.e., mesh size is decreased) up to a value of approximately 300 Pa, beyond which it decreases. In the second set of measurements, the trapped particle size was increased in a gel medium of constant mesh size, with G’ approximately 100 Pa. In this case, the measured μd is found to be effectively constant over the particle size range studied (14-120 nm), i.e., it is independent of the degree of trapping as expressed by the ratio of the particle size to the mesh size.

36 MATERIALS SCIENCE↗

Effect of highly carboxylated colloidal polymers on cement hydration and interactions with calcium ions

Polymer latexes are often found to retard cement hydration. Interaction of polymer particles with Ca{sup 2+} in pore solution and adsorption of polymer on cement were proposed as possible mechanisms for the retardation effect. This paper aims at disclosing the retardation mechanism of colloidal polymers using a highly carboxylated polystyrene latex. Interaction between colloidal particles and Ca{sup 2+} was studied by post-treatment of the latex with Ca(NO{sub 3}){sub 2}. Techniques including calorimetry, adsorption test, ICP-OES, SEM, are involved to investigate effects of the post-treated latexes on hydrations of cement and C{sub 3}S. It is found that enrichment of Ca{sup 2+} on surface of colloidal particles doesn't contribute to the retardation effect of polymer on cement hydration. Furthermore, the acceleration effect of the two-step treated latex using Ca(NO{sub 3}){sub 2} and Na{sub 2}SiO{sub 3} suggests that nucleation inhibition of the adsorbed polymer layer on cement surface is the more conceivable mechanism responsible for the retardation effect of the highly carboxylated latex.

36 MATERIALS SCIENCE↗

Transparent Conductive Adhesives for Tandem Solar Cells

Methods of making silicon based tandem cells include wafer bonding, depositing absorber layers on the surface, and mechanical stacking. Of these, mechanically stacking after growth retains the individual cell quality during production, but typically requires a four-terminal device. We present a transparent conductive adhesive (TCA) interlayer, designed for transparency in wavelengths that Si absorbs, conductivity for out-of-plane conductivity between cells, and adhesive strength, enabling two-terminal stacked tandems. The developed TCA material is a polymer-particle blend of common transparent adhesives and metal-coated flexible microspheres, capable of bridging micro-scale gaps between uneven/textured surfaces. At 10% microsphere coverage, experimental and theoretical series resistance is compatible with high-efficiency tandem cells on silicon.

14 SOLAR ENERGY↗

Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.

36 MATERIALS SCIENCE↗